• 제목/요약/키워드: $CO_2$ monitoring

검색결과 916건 처리시간 0.038초

60kgf/$\textrm{mm}^2$급 자동차 범퍼빔용 레이저 용접 튜브 제조기술 및 장치연구 (Production of Laser Welded Tube for Automobile Bumper Beam from 60kgf/$\textrm{mm}^2$Grade Steel Sheet)

  • 서정;이제훈;김종수;김정오;강희신;이문용;정병훈
    • 한국정밀공학회지
    • /
    • 제21권7호
    • /
    • pp.136-144
    • /
    • 2004
  • Optimal process and system to produce the laser welded tube for one body formed bumper beam are studied. The calculated size of tube is a thickness of 1.4mm, diameter of 105.4mm and length of 2000mm. The tube is shaped from a cold rolled high strength steel sheet(tensile strength: 60kgf/$\textrm{mm}^2$ grade). Two roll bending method is the optimal tube shaping process compared to UO-bending, bending on press brake, multi-step continuous roll forming and 3 roll bending methods. Weld quality monitoring and seam tracking along the butt-joint lengthwise to the tube axis are also studied. The longitudinal butt-joint is welded by the $CO_2$ laser welding system equipped with a seam tracker and plasma sensor. The constructed $CO_2$laser tube welding system can be used for the precision seam tracking and the real-time monitoring of weld quality. Finally, the obtained laser welded tube can be used for one-body formed automobile bumper beam.

Emergency Brushless Synchronous Generator Having Rotating Exciter Status Monitoring and Protection Functions

  • Oh, Yongseung;Oh, Wonseok;Cho, Kyumin
    • 한국정보기술학회 영문논문지
    • /
    • 제10권2호
    • /
    • pp.1-13
    • /
    • 2020
  • This paper presents an emergency brushless synchronous generator having rotating exciter status monitoring and protection functions. For monitoring the rotating exciter status, a wireless rotor status detector and a digital AVR(Automatic Voltage Regulator), which has a wireless communication capability, are proposed. The proposed rotor status detector detects temperatures of exciter armature and main field windings and input voltage and current of the main field. Therefore, it is possible to protect the generator from the over-temperature of windings and detect the exciter bridge diode fault. Furthermore, the proposed digital AVR has rotor status monitoring and protection function, and remote generator tuning, wireless group parallel operation function. So the operator can efficiently operate the generator using a smartphone from a remote area.

독수리(Aegypius monachus)의 흡입마취에서 Capnography를 이용한 호기말 이산화탄소분압 모니터링 (Capnographic Monitoring of End-Tidal Partial Pressure of Carbon Dioxide in Anesthetized Cinereous vultures (Aegypius monachus))

  • 박원규;석성훈;박세진;이승용;김영기;황재민;정동혁;이희천;연성찬
    • 한국임상수의학회지
    • /
    • 제32권4호
    • /
    • pp.380-384
    • /
    • 2015
  • The relationships between end-tidal partial pressure of carbon dioxide ($P_{ET}CO_2$) and arterial partial pressure of carbon dioxide ($P_aCO_2$), and between $P_{ET}CO_2$ and blood pH in isoflurane-anesthetized cinereous vultures were evaluated. Nine cinereous vultures (weighing 7.3-9.5 kg) were anesthetized via mask with isoflurane, intubated, and connected to a mechanical ventilator. By mechanical ventilator, respiratory rate was altered to achieve a $P_{ET}CO_2$ randomly selected among 30 to 35 mmHg. $P_aCO_2$ and blood pH were determined in serial arterial samples and compared with concurrent $P_{ET}CO_2$ measured with a sidestream capnography. Thirty six samples, nine cinereous vultures were tested 4 times each, were used to determine correlations coefficients between $P_aCO_2$ and $P_{ET}CO_2$, and between $P_{ET}CO_2$ and blood pH. Strong correlations were observed between $P_aCO_2$ and $P_{ET}CO_2$ (r = 0.951, P = 0.000, y = 1.679x - 30.236, $R^2=0.905$) as well as between $P_{ET}CO_2$ and blood pH (r = -0.728, P = 0.000, y = -0.024x + 8.389, $R^2=0.530$) with Pearson's correlation coefficient and simple linear regression. These results suggest that the capnography used provided a sufficiently accurate estimation of $P_aCO_2$ and blood pH. Thus, the monitoring of $P_{ET}CO_2$ can be useful method to prevent hypoventilation for cinereous vultures receiving mechanical ventilation.

인도네시아 머루압 유전에 이산화탄소 주입 시 균열대 생성 여부 모니터링 (Monitoring of Fracture Occurrence During Carbon Dioxide Injection at the Meruap Oil Reservoir, Indonesia)

  • 김도완;변중무;김기석;안태웅
    • 지구물리와물리탐사
    • /
    • 제19권1호
    • /
    • pp.37-44
    • /
    • 2016
  • $CO_2$-EOR ($CO_2$-Enhanced Oil Recovery)은 석유회수증진법 중 하나로, 석유 생산량을 증대시키는 동시에 이산화 탄소를 지중에 격리시킬 수 있는 기술이다. 하지만 이산화탄소 주입 시, 지층 내 균열이 발생하는 경우 저류층 내에 이산화탄소의 영구저장이 어려워지고, 지하수 및 토양의 오염을 야기할 수 있다. 따라서 이 연구에서는 인도네시아 머루압 유전에 이산화탄소 주입 시, 미소진동 모니터링을 수행하여 저류층 내 균열의 발생여부를 파악하고자 하였다. 미소진동 초동 발췌에는 Improved MER (Modified Energy Ratio) 방법을 이용하였다. 초동 발췌 후에는 이벤트의 방위각을 계산하기 위하여 다성분 지오폰에서 기록된 트레이스를 이용해 호도그램 분석을 수행하였다. 최종적으로 초동 발췌 결과와 호도그램 분석 결과를 이용하여 미소진동 위치결정을 수행하였다. 미소진동 위치결정 결과를 통해 저류층 주변에 균열의 발생여부를 확인해 본 결과, 미소진동 발생 위치는 모두 지표에서 나타나고 있으며 저류층 내 균열은 확인되지 않았다. 또한 잡음의 특성을 분석하여 초동 발췌된 이벤트가 대부분 규칙적인 기계적 잡음에 의한 것임을 확인할 수 있었다.

인위적 CO2 누출에 따른 토양 CO2 플럭스와 농도의 시공간적 모니터링 (Spatio-Temporal Monitoring of Soil CO2 Fluxes and Concentrations after Artificial CO2 Release)

  • 김현준;한승현;김성준;윤현민;전성천;손요환
    • 환경영향평가
    • /
    • 제26권2호
    • /
    • pp.93-104
    • /
    • 2017
  • CCS (Carbon Capture and Storage)는 공업용 자원이나 에너지 기반의 자원으로부터 $CO_2$를 포집하여 고갈 유 가스전, 석탄층, 바다, 심부 대염수층 등에 저장하는 기술이다. 그러나 잠재적인 $CO_2$ 누출은 환경문제를 유발할 수 있기 때문에 저심도에서 $CO_2$의 누출을 검출할 수 있는 모니터링 기술이 필요하다. 따라서 본 연구는 인위적인 $CO_2$ 누출실험을 통해 지표면 부근에서 토양 $CO_2$가 확산되는 경향을 분석하고자 실시하였다. 시험대상지 "The Environmental Impact Evaluation Test Facility (EIT)"는 2015년에 충북 음성군 대소면에 설치되었다. 총 5개의 구역 중 2, 3, 4구역에서 약 34 kg $CO_2$/day/zone의 $CO_2$를 2015년 10월 26일부터 30일까지 주입하였다. $CO_2$ 플럭스는 LI-8100A를 이용하여 3구역의 누출구로부터 0m, 1.5m, 2.5m, 10m 지점의 지표면에서 11월 13일까지 매 30분마다 측정하였으며, $CO_2$ 농도는 GA5000을 이용하여 3개 구역의 누출구로부터 0m, 2.5m, 5.0m, 10m 지점의 15cm, 30cm, 60cm 깊이에서 11월 28일까지 1일 1회 측정하였다. $CO_2$ 플럭스는 누출시작 5일 후에 누출구로부터 0m 지점에서 확인되었으며 누출이 종료된 이후에도 11월 13일까지 계속 증가하였다. 2.5m, 5.0m, 10m 지점의 $CO_2$플럭스 간에는 유의한 차이를 보이지 않았다. 한편, $CO_2$ 농도는 인위적인 $CO_2$ 누출이후 둘째 날에 3구역의 누출구로부터 0m 지점의 60cm 깊이에서 38.4%로 측정되었다. $CO_2$ 농도는 시간이 지날수록 수평적으로 더 넓게 확산되었으나, $CO_2$ 누출을 종료할 때까지 모든 구역에서 누출구로부터 5m 지점까지만 검출되었다. 또한, $CO_2$ 누출 마지막 날에 30cm와 60cm 깊이에서 $CO_2$ 농도는 각각 $50.6{\pm}25.4%$$55.3{\pm}25.6%$로 유사하게 측정되었으나, 15cm 깊이에서는 $31.3{\pm}17.2%$로 다른 지점에 비해 유의하게 낮은 것으로 나타났다. $CO_2$ 누출을 종료한 후 모든 구역의 모든 깊이에서 $CO_2$ 농도는 약 1달 동안 서서히 감소하였지만 누출 직후보다는 여전히 높았다. 결론적으로 누출구로부터 가깝고 깊이가 깊을수록 $CO_2$ 플럭스와 농도는 높은 것으로 나타났으며, 누출이 된 $CO_2$ 기체는 누출이 멈추더라도 장기간 토양 내에 잔류할 수 있기 때문에 장기 모니터링이 필요할 것으로 판단된다.

수산화바륨을 이용한 이산화탄소 확산측정법의 개발 및 평가 (Development and Evaluation of a Carbon Dioxide Diffusive Sampling Method using Barium Hydroxide)

  • 임봉빈
    • 한국대기환경학회지
    • /
    • 제29권1호
    • /
    • pp.56-63
    • /
    • 2013
  • This study was aimed at developing and evaluating a diffusive sampling method using a barium hydroxide solution as an absorbent for measuring carbon dioxide ($CO_2$) in ambient air. The collected $CO_2$ concentration was calculated by the change of conductivity resulted in the reaction of $CO_3{^{2-}}$ and $Ba^{2+}$ in aqueous solution. The sampling rate for the diffusive sampler was determined 0.218 mL/min, as obtained from the slope of the linear correlation between the $CO_2$ mass collected by the diffusive sampler and the time-weighted $CO_2$ concentration with the active sampling method. The unexposed blank sampler sealed in aluminium foil-polyethylene laminated packets has remained stable during at least one-month storage period. A good correlation was observed between the diffusive sampler and active sampler with a coefficient of determination of 0.956. This diffusive sampler would be suitable for the indoor $CO_2$ concentration monitoring.

의복착용형 무선 호흡모니터 시스템 (Wearable wireless respiratory monitoring system)

  • 이인광;김성식;장종찬;김군진;김경아;이태수;차은종
    • 센서학회지
    • /
    • 제17권2호
    • /
    • pp.133-142
    • /
    • 2008
  • Respiration is induced by muscular contraction of the chest and abdomen, resulting in the abdominal volume change. Thus, continuous measurement of the abdominal dimension enables to monitor breathing activity. Conductive rubber cord has been previously introduced and tested to develop wearable application for respiratory measurements. The present study implemented wireless wearable respiratory monitoring system with the conductive rubber cord in the patient's pants. Signal extraction circuitry was developed to obtain the abdominal circumference changes reflecting the lung volume variation caused by respiratory activity. Wireless transmission was followed based on the zigbee communication protocol in a size of 65mm${\times}$105mm easily put in pocket. Successful wireless monitoring of respiration was performed in that breathing frequency was accurately estimated as well as different breathing patterns were easily recognized from the abdominal signal. $CO_2$ inhalation experiment was additionally performed in purpose of quantitative estimation of tidal volume. Air mixed with $0{\sim}5%\;CO_2$was inhaled by 4 normal males and the respiratory air flow rate, abdominal dimension change, and end tidal $CO_2$ concentration were simultaneously measured in steady state. $CO_2$ inhalation increased the tidal volume in normal physiological state with a correlation coefficient of 0.90 between the tidal volume and the end tidal $CO_2$ concentration. The tidal volume estimated from the abdominal signal linearly correlated with the accurate tidal volume measured by pneumotachometer with a correlation coefficient of 0.88 with mean relative error of approximately 8%. Therefore, the tidal volume was accurately estimated by measuring the abdominal dimension change.

광물찌꺼기 적치장 유지관리를 위한 모니터링 방안 연구 (Study of Monitoring Methods for Maintenance Management of Tailings Dams)

  • 오삼주;김기준;송재용;최의규
    • 지질공학
    • /
    • 제26권4호
    • /
    • pp.473-484
    • /
    • 2016
  • 본 연구는 환경유해시설인 광물찌꺼기 적치장의 효과적 유지관리를 위한 모니터링 방안을 수립하기 위해 수행하였다. 광물찌꺼기 적치장 유지관리를 위한 모니터링은 세분된 점검항목 및 평가항목의 선정을 통해 상세한 조사가 필요하며, 조사결과를 효과적으로 활용하기 위하여 불량정도 및 그 진행성 여부에 대한 평가가 필요하다. 따라서 모니터링 항목을 옹벽구조물(콘크리트 옹벽, 석축, 돌망태) 및 일반시설물(차수층, 복토층, 사면, 광물찌꺼기, 우수배제시설, 침출수, 식생)로 점검항목을 세분하고, 각 항목별 모니터링 결과에 대한 상태평가를 수행하여 등급 및 점수화를 통해 체계적인 유지관리가 될 수 있도록 모니터링 개선안을 제안하였다. 개선안에 따른 현장 적용성 평가 결과, 기존 모니터링에 비해 최대 16건(우수배제시설)의 하자 발생 건수가 추가로 확인되는 등 기존 모니터링에 비해 세부적인 평가가 가능한 것으로 확인되었으며, 등급에 따른 광물찌꺼기 적치장별 종합점수는 금장광산이 89.3점으로 가장 양호하고 거풍광산이 22.2점, 화천광산이 27.8점으로 가장 불량한 것으로 확인되었다. 이와 같이 개선안을 적용할 경우, 보다 상세한 모니터링을 수행할 수 있고 각각의 항목에 대한 정량적인 평가가 가능하다. 이러한 정량적 평가는 향후 광물찌꺼기 적치장의 보수 우선순위를 결정하고 중점관리항목 선정, 유지보수 계획수립에 활용될 수 있을 것으로 판단된다.

환기가 불량한 실내공간에서, 담배연기에 의한 CO, $CO_2$, TVOC 및 에어로졸의 변화 (Changes of CO, $CO_2$, TVOC and Aerosol of Tobacco Smoke in a Poorly-Ventilated Indoor)

  • 한돈희;박수진;류지혜
    • 한국환경보건학회지
    • /
    • 제32권2호
    • /
    • pp.132-139
    • /
    • 2006
  • Number of aerosol, CO, $CO_2$ and TVOC after one-, two-, three-cigarettes smoking were monitored with time every 10 minute for 180 minutes in the seminar room (volume $51.1m^3$) when poorly-ventilated. IAQ monitor (IAQRAE, model PGM-5210) and PortCount (TSI, model 8020) were used for monitoring. Aerosol was decreased with exponential decay equation and it was estimated that number of aerosol would be long suspended (one cigarette 75/cc. two cigarettes 66/cc, three cigarettes 141/cc by 8hrs after smoking). While CO was also decreased with exponential or linear decay equation and correlated with number of aerosol strongly, TVOC and $CO_2$ were increased with linear equation in accordance with time lag. Most of TVOC and $CO_2$ were above standard levels of Korean Indoor Air Quality (Ministry of Environment) without regarding number of cigarettes. When naturally ventilated, all of CO, $CO_2$ and TVOC concentrations were dramatically decreased below standard levels of Korean Indoor Air Quality.

써모파일 센서를 이용한 NDIR CO2 가스검출기의 개발 (Development of NDIR CO2 Gas Detector Using Thermopile Sensor)

  • 조시형;박찬원
    • 산업기술연구
    • /
    • 제32권A호
    • /
    • pp.35-38
    • /
    • 2012
  • We present a novel non-dispersive infrared (NDIR) $CO_2$ gas sensor with a light source emitting collimated light. Using this thermopile, we also have successfully developed a small, sensitive NDIR $CO_2$ detector module for accurate air quality monitoring systems in energy-saving building and automotive applications. The novel sample cavity comprising specular reflectors around the light bulb is configured to uniformly emit collimated light into the entrance aperture of the cavity in order to enhance the sensitivity of NDIR $CO_2$ detector.

  • PDF