• Title/Summary/Keyword: $CO_2$ monitoring

Search Result 920, Processing Time 0.028 seconds

Investigation on the Validation for Designating Air Quality Control Region among Provincial Cities by the Data Measured with Air Quality Monitoring Network (대기오염 측정 자료에 의한 지방도시의 대기환경규제지역 설정에 관한 타당성 검토)

  • Yu, Mee-Seon;Yang, Sung-Bong;Woo, Kyung-Bin
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.181-190
    • /
    • 2016
  • Regional air quality regulation is a system that allows the Minister of Environment to designate the local area as air quality control region where the concentrations of air pollutants are exceeding the environmental standards, and the local governments that administrate the regulated area have to develop and practise a plan for reducing the air pollutants. From the data observed yearly by the monitoring stations in 8 provincial cities with more than 0.5 million people was judged the compliance with air quality standards in each municipality for the period of 2003 to 2013. As the result of investigation on air pollutants concentrations of each city, it was found that there was no station that exceeds the ambient air quality standards of CO, $SO_2$ and 24-hour $NO_2$. But all municipalities exceeded the standards of 8-hour $O_3$, annual and 24-hour $PM_{10}$, and therefore 8 municipalities can be designated to be under the local air regulation. For the annual $NO_2$ were the monitoring sites necessary requirements for designation of the air quality regulation region in Cheongju, Cheonan, Daejeon and Gwangju area. Incase of 1-hour $O_3$, some of stations in Pohang, Cheongju, Cheonan and Changwon area were over the designation standards for the air quality control region.

A Comprehensive Review of Geological CO2 Sequestration in Basalt Formations (현무암 CO2 지중저장 해외 연구 사례 조사 및 타당성 분석)

  • Hyunjeong Jeon;Hyung Chul Shin;Tae Kwon Yun;Weon Shik Han;Jaehoon Jeong;Jaehwii Gwag
    • Economic and Environmental Geology
    • /
    • v.56 no.3
    • /
    • pp.311-330
    • /
    • 2023
  • Development of Carbon Capture and Storage (CCS) technique is becoming increasingly important as a method to mitigate the strengthening effects of global warming, generated from the unprecedented increase in released anthropogenic CO2. In the recent years, the characteristics of basaltic rocks (i.e., large volume, high reactivity and surplus of cation components) have been recognized to be potentially favorable in facilitation of CCS; based on this, research on utilization of basaltic formations for underground CO2 storage is currently ongoing in various fields. This study investigated the feasibility of underground storage of CO2 in basalt, based on the examination of the CO2 storage mechanisms in subsurface, assessment of basalt characteristics, and review of the global research on basaltic CO2 storage. The global research examined were classified into experimental/modeling/field demonstration, based on the methods utilized. Experimental conditions used in research demonstrated temperatures ranging from 20 to 250 ℃, pressure ranging from 0.1 to 30 MPa, and the rock-fluid reaction time ranging from several hours to four years. Modeling research on basalt involved construction of models similar to the potential storage sites, with examination of changes in fluid dynamics and geochemical factors before and after CO2-fluid injection. The investigation demonstrated that basalt has large potential for CO2 storage, along with capacity for rapid mineralization reactions; these factors lessens the environmental constraints (i.e., temperature, pressure, and geological structures) generally required for CO2 storage. The success of major field demonstration projects, the CarbFix project and the Wallula project, indicate that basalt is promising geological formation to facilitate CCS. However, usage of basalt as storage formation requires additional conditions which must be carefully considered - mineralization mechanism can vary significantly depending on factors such as the basalt composition and injection zone properties: for instance, precipitation of carbonate and silicate minerals can reduce the injectivity into the formation. In addition, there is a risk of polluting the subsurface environment due to the combination of pressure increase and induced rock-CO2-fluid reactions upon injection. As dissolution of CO2 into fluids is required prior to injection, monitoring techniques different from conventional methods are needed. Hence, in order to facilitate efficient and stable underground storage of CO2 in basalt, it is necessary to select a suitable storage formation, accumulate various database of the field, and conduct systematic research utilizing experiments/modeling/field studies to develop comprehensive understanding of the potential storage site.

Prediction of Energy Saving Effects by Commissioning of High-Rise Building (초고층 건물 커미셔닝에 따른 에너지 절감 효과 예측)

  • Cho, Hyun;Kim, Hyo-Jun;Ryu, Seung-Ryong;Cho, Young-Hum
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.1
    • /
    • pp.30-35
    • /
    • 2018
  • In this study, the energy commissioning was conducted for high-rise buildings(manual control). First of all, we conducted monitoring the energy use of buildings (electricity, heating, etc.), a commissioning improvement (automatic control) was proposed for each system. In addition, energy simulation was conducted to predict the effectiveness of the reform measures. As a result, terminal units control the greatest energy saving effect, If we applied all the improvements, we could save about 20% less than traditional energy usage, and it turned out that $CO_2$ emissions were reduced by about 19% when converted to $CO_2$.

A Study on the Selectivity of Gas Sensors by Sensing Pattern Recognition (감지 패턴 인식에 의한 가스센서의 선택성 연구)

  • Lee, Sung-Pil
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.428-433
    • /
    • 2011
  • We report on the building of a micro sensor array based on typical semiconductor fabrication processes aimed at monitoring selectively a specific gas in ambient of other gases. Chemical sensors can be applied for an electronic nose and/or robots using this technique. Microsensor array was fabricated on the same chip using 0.6${\mu}m$ CMOS technology, and unique gas sensing patterns were obtained by principal component analysis from the array. $SnO_2$/Pt sensor for CO gas showed a high selectivity to buthane gas and humidity. $SnO_2$ sensor for hydrogen gas, however, showed a low selectivity to CO and buthane gas. We can obtain more distinguishable patterns that provide the small sensing deviation(the high seletivity) toward a given analyte in the response space than in the chemical space through the specific parameterization of raw data for chemical image formation.

Development and its Application for Energy Efficiency Operation Indicator and Energy Efficiency Design Index Monitoring System on the Ship (선박의 에너지효율운전지표와 에너지효율설계지수의 모니터링 시스템 개발과 그 응용)

  • Lee, Don-Chool;Kim, Eoue-Sek;Joo, Ki-Se;Nam, Jeong-Gil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.500-507
    • /
    • 2010
  • Regard to the global warming, the shipping industries are progressed the dedicated endeavor to reduce greenhouse gas. As the study results of 2009 GHG study team, the $CO_2$ emission of shipping industries exceeded slightly 1.0 billion ton during one year(2007) and it is 3.3% of total $CO_2$ amount exhausted from all industries. This paper are introduced the energy efficiency design index / operation indicator monitoring system(EDiMS) which matched with EVAMOS software released by the dynamics laboratory of Mokpo maritime university. EDiMS can continuously be monitored amounts of $CO_2$, NOx, SOx, and PM emitted from ship and it can be applied as the useful tool of the inventory work of air pollution and the ship energy management plan for the mitigation or reduction of ship emission.

Sensitive determination of paroxetine in canine plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) (LC-MS/MS를 이용한 비글견 혈장 중 파록세틴의 고감도 분석)

  • Chang, Kyu Young;Kang, Seung Woo;Han, Sang Beom;Youm, Jeong-Rok;Lee, Kyung Ryul;Lee, Hee Joo
    • Analytical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.138-146
    • /
    • 2007
  • A simple and sensitive method for the determination of paroxetine in canine plasma was developed and validated by liquid-liquid extraction and liquid chromatography-tandem mass spectrometry (LC-/MS/MS). Fluoxetine was used as an internal standard. Paroxetine and internal standard in plasma samples were extracted using TBME (tert-butyl methyl ether). A centrifuged upper layer was then evaporated and reconstituted with mobile phase of 50% acetonitrile adjusted to pH 3 by formic acid. The reconstituted samples were injected into a Capcell Pak UG120 ($2.0{\times}150mm$, $5{\mu}m$) column. Using MS/MS with SRM (selective reaction monitoring) mode, the transitions (precursor to product) monitored were m/z $330{\rightarrow}192$ for paroxetine, and m/z $310{\rightarrow}148$ for internal standard. Linear detection responses were obtained for paroxetine concentration range of 0.02~5 ng/mL. A correlation coefficient of linear regression ($R^2$) was 0.9993. Detection of paroxetine in canine plasma was accurate and precise, with limit of quantification at 0.02 ng/mL. The method has been successfully applied to pharmacokinetic study of paroxetine in healthy beagle dogs.

지능형 금형공장 개발

  • Choe, Byeong-Gyu;Go, Gi-Hun;Kim, Bo-Hyeon
    • CDE review
    • /
    • v.11 no.2
    • /
    • pp.15-22
    • /
    • 2005
  • Presented in the paper is an approach to developing an intelligent mold shop as a means to overcome the difficulties faced by mold-makers due to skill shortages and increased global competition. A machine shop where as much as of the human skills are replaced by a set of intelligent systems is called an intelligent machine shop, and an intelligent mold-making machine shop is called an intelligent mold shop(MS). By analyzing the contents of operator's skill. three intelligent S/W stations have been designed: Technical Data Processing(TDP) Station, Loading Schedule Station, and Real-time Monitoring Station. A detailed architecture of the TDP station is described, and measures of effectiveness of IMS are elaborated.

  • PDF

A study on the autonomous control system for an unmanned surface vessel?

  • Park, Soo-Hong;Kim, Jong-Kwon;Jang, Cheol-Soon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.417-420
    • /
    • 2004
  • Recently, the applications of unmanned system are steadily increasing. Unmanned automatic system is suitable for routine mission such as reconnaissance, environment monitoring, resource conservation and investigation. Especially, for the ocean environment monitoring mission, many ocean engineers had scoped with the routine and even risky works. The automatic system can replace the periodic and routine missions: water sampling, temperature and salinity measuring, etc. In this paper, an unmanned surface vessel was designed for routine and periodic ocean environmental missions. An autonomous control system was designed and tested for the unmanned vessel. A GPS and gyro compass was used for navigation. A linear autopilot model for course control can be derived from the maneuvering model. Nomoto's 2nd-order response equation was derived. The design methodologies and performance of the surface vessel were illustrated and verified with this linearized equation of motion. A linear controller was designed and automatic route tracking performance was verified for yaw subsystem.

  • PDF

Clinical Significance of Urinalysis with Test Strips (복합시험지법(複合試驗紙法)에 의한 이상뇨(異常尿) 검사(檢査)의 임상적(臨床的) 의의(意義))

  • Sohn, Tai-Hyu
    • The Journal of the Korean life insurance medical association
    • /
    • v.2 no.1
    • /
    • pp.75-81
    • /
    • 1985
  • Urine contains protein and nucleic acid(urea, uric acid, creatinine, ammonia, amino acids), various organic and inorganic materials, vitamin, hormone, enzyme etc. The examination of gualitative or quantitative change of the above mentioned materials and picking up the abnormal materials are useful to diagnose diseases. The test strip for examination of urine is applied to the routine test, monitoring of medical therapy and recurrence, self monitoring, and screeing in preventive medicine. We have been using multitest strip for checking the bacterial infection(nitrite), PH, protein, glucose, ketone body, urobilinogen, bilirubin and occult blood. So it is possible to diagnose three groups of diseases as follows, abnormal metabolism of the carbohydrate, diseases of kidney and other urogenital system, diseases of hepatobiliary system and hemolytic disease causing abnormal metabolism of bile juice.

  • PDF