• 제목/요약/키워드: $CO_2$ monitoring

검색결과 916건 처리시간 0.019초

Application of single-well push-drift-pull tests using dual tracers (SF6 and salt) for designing CO2 leakage monitoring network at the environmental impact test site in Korea

  • Kim, Hong-Hyun;Lee, Seong-Sun;Ha, Seung-Wook;Lee, Kang-Kun
    • Geosciences Journal
    • /
    • 제22권6호
    • /
    • pp.1041-1052
    • /
    • 2018
  • A single-well push-drift-pull tracer test using two different tracers ($SF_6$ and salt) was performed at the Environmental Impact Test (EIT) site to determine suitable locations for monitoring wells and arrange them prior to artificial $CO_2$ injection and leak tests. Local-scale estimates of hydraulic properties (linear groundwater velocity and effective porosity) were obtained at the study site by the tracer test with two tracers. The mass recovery percentage of the volatile tracer ($SF_6$) was lower than that of the non-volatile tracer (salt) and increased drift time may make degassing of $SF_6$ intensified. The $CO_2$ leakage monitoring results for both unsaturated and saturated zones suggest that the $CO_2$ monitoring points should be located near points at which a high concentration gradient is expected. Based on the estimated hydraulic properties and tracer mass recovery rates, an optimal $CO_2$ monitoring network including boreholes for monitoring the unsaturated zone was constructed at the study site.

다채널 지표토양 CO2 농도 모니터링(SCM) 시스템 개발 및 적용성 평가 연구 (Applicability of the Multi-Channel Surface-soil CO2-concentration Monitoring (SCM) System as a Surface Soil CO2 Monitoring Tool)

  • 성기성;유순영;최병영;박진영;한래희;김정찬;박권규;채기탁
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권1호
    • /
    • pp.41-55
    • /
    • 2015
  • Monitoring of $CO_2$ release through the ground surface is essential to confirm the safety of carbon storage projects. We conducted a feasibility study of the multi-channel surface-soil $CO_2$-concentration monitoring (SCM) system as a soil $CO_2$ monitoring tool with a small scale injection test. The background concentrations showed the distinct diurnal variation. The negative relation of $CO_2$ with temperature and the low $CO_2$ concentrations during the day imply that surface-soil $CO_2$ depends on photosynthesis and respiration. After 4.2 kg of $CO_2$ injection (1 m depth for 29 minutes), surface-soil $CO_2$ concentrations increased in the all five chambers, which were located less than 2.8 m of distance from each other. The $CO_2$ concentrations seem to be recovered to the background around 4 hours after the injection ended. To determine the leakage, the data from Chamber 2 and 5 with low increase rates were used for statistical analyses. Coefficient of variation for 30 minutes ($CV_{30min}$.) is efficient to determine a leakage signal, with reflecting the fast change in $CO_2$ concentrations. Consequently, SCM and $CV_{30min}$ could be applied for an efficient monitoring tool to detect $CO_2$ release through the ground surface. Also, this study provides ideas for establishing action steps after leakage detection.

국내 CO2 지중저장과 지구물리탐사의 역할 (Geophysics for Carbon Capture and Storage in Korea)

  • 황세호;박권규
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2009년도 학술대회 초록집
    • /
    • pp.16-19
    • /
    • 2009
  • 최근 온실가스감축의 방법으로 이산화탄소 지중저장이 많은 관심을 받고 있다 CO2 지중저장을 위한 부지 선정 및 특성화, CO2 주입에 따른 모니터링 단계 등 지중저장 전 파전에서 지구물리탐사법이 중요한 역활을 담당할 것으로 예상된다. 특히 주입된 CO2의 거동과 누출에 대한 모니터링과 검증기술은 온실가스감축의 인정과 신뢰성 향상에 많은 기여를 할 것으로 기대된다.

  • PDF

무선센서 네트워크를 이용한 가축생육환경정보 실시간 모니터링 시스템 구현 (Implementation of Real-Time Monitoring System for Livestock Growth Environment Information using Wireless Sensor Network)

  • 김영웅;백승현;전용준;이대기;박홍배
    • 대한임베디드공학회논문지
    • /
    • 제7권6호
    • /
    • pp.301-309
    • /
    • 2012
  • In this paper, a real-time monitoring system based on WSN is designed and implemented to monitor livestock growth environment information which includes the temperature, humidity and harmful gases such as $CO_{2},\;CO,\;NH_{3},\;H_{2}S$ and so on. The proposed system consists of the wireless sensor nodes, the monitoring management device, the management server and the user interface program based on PC/Smart phone. To verify the performance of the implemented system, gas measurement experiments are performed in laboratory environment by using the designed wireless sensor nodes. And it is able to estimate the concentration of gases. The implemented system is able to monitor the proposed environmental element information through the developed GUI.

$CO_2$ 레이저를 이용한 용접튜브 제조공정에서의 용접선 추적 및 용접품질 모니터링 (Weld Quality Monitoring and Seam Tracking in Making of Welded Tube using $CO_2$ Laser)

  • 서정;이제훈;김정오;강희신;이문용;정병훈
    • Journal of Welding and Joining
    • /
    • 제21권7호
    • /
    • pp.34-41
    • /
    • 2003
  • Weld quality monitoring and seam tracking along the butt-joint lengthwise to the tube axis are studied. The material of tube is 60kg/$\textrm{mm}^2$ grade steel sheet, and the longitudinal butt-joint is shaped by 2 roll bending machine. The tube with a thickness of 1.5mm, diameter of 105.4mm and length of 2000mm is successfully obtained by the $CO_2$ laser welding system equipped with a seam tracker and plasma sensor. Experimental results show that the developed welding system can be used for the precision seam tracking and the real-time monitoring of weld quality, and the laser welded tube can be used for car body md component after tubular hydroforming.

Seismic wave monitoring of $CO_2$ migration in water-saturated porous sandstone

  • Xue Ziqiu;Ohsumi Takashi
    • 지구물리와물리탐사
    • /
    • 제7권1호
    • /
    • pp.25-32
    • /
    • 2004
  • We have carried out laboratory measurements of P-wave velocity and deformation strain during $CO_2$ injection into a porous sandstone sample, in dry and water-saturated conditions. The rock sample was cylindrical, with the axis normal to the bedding plane, and fluid injection was performed from one end. Using a piezoelectric transducer array system, we mapped fluid movement during injection of distilled water into dry sandstone, and of gaseous, liquid, and supercritical $CO_2$ into a water-saturated sample. The velocity changes caused by water injection ranged from $5.61\;to\;7.52\%$. The velocity changes caused by $CO_2$ injection are typically about $-6\%$, and about $-10\%$ for injection of supercritical $CO_2$, Such changes in velocity show that the seismic method may be useful in mapping $CO_2$ movement in the subsurface. Strain normal to the bedding plane was greater than strain parallel to the bedding plane during $CO_2$ injection; injection of supercritical $CO_2$ showed a particularly strong effect. Strain changes suggest the possibility of monitoring rock mass deformation by using borehole tiltmeters at geological sequestration sites. We also found differences associated with $CO_2$ phases in velocity and strain changes during injection.

지하대기중의 CO 및 $CO_2$의 일변화 특성에 관한 연구 (On the Diurnal Variations of CO and $CO_2$ in the Underground Atmospheric Environments)

  • 이동인;이지연
    • 한국환경과학회지
    • /
    • 제3권4호
    • /
    • pp.381-391
    • /
    • 1994
  • This paper presents the disributions and variations of CO, $CO_2$, number of people and temperature in underground shopping center and subway of Seomyeon and Jagalchi in Pusan, Korea for two times during October and November in 1993, respectively. NDIR analyzer is used for the analysis of CO and $CO_2$. The temperature is obtained from a mercury therometer. The results o( observation and analysis show that the variation of $CO_2$ is strongly related to number of people and temperature. The correlation coefficients between temperature, COB and Number of people are higher than 0. at both of places. The pollution of CO2 of Seomyeon is higher than that of Jagachi in underground shopping center. However, CO is not correlated with the temperature and the Number of people. From the results, we found that the indoor air quality monitoring system is needed for the prevention of the underground air Pollution.

  • PDF

영일만 해상 CO2 주입 실증 사이트에서의 주입 전 모니터링 탐사 예비결과 (Preliminary Results of the Pre-injection Monitoring Survey at an Offshore CO2 Injection Site in the Yeongil Bay)

  • 박명호;이창식;김병엽;김지훈;김규중;신영재
    • 지질공학
    • /
    • 제28권2호
    • /
    • pp.247-258
    • /
    • 2018
  • 포항분지 해상 중규모 실증 모니터링 연구팀은 영일만의 해상 $CO_2$ 주입 실증 사이트에서 주입되는 $CO_2$를 모니터링하기 위하여 지구물리-지화학 복합 모니터링 연구를 수행하고 있다. 이 연구에서는 주입 전 모니터링 탐사의 1차 결과로서, 지구물리 탐사에서는 한국형 Hydro-Geophone OBS (Ocean Bottom Sensor) 탐사장비 개발 현황과 3D 탄성파 탐사의 결과를, 천부 지화학 탐사에서는 주입사이트의 주입 전지화학 베이스라인 탐사(퇴적물 공극수의 음이온)에 대한 예비결과를 제시하였다.

혼소율을 고려한 화력 발전소의 CO2 대기배출량 계산 (Calculation of CO2 Emission for Fossil-Fired Thermal Power Plant considering Coal-Oil Mix Rate)

  • 이상중;김순기
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.67-72
    • /
    • 2010
  • G8 summit meeting held in July 2008 decided to set up a long-term goal, by 2050, reducing the world greenhouse emissions by half of those emitted in 1990. In November 2009, the Government announced to reduce the national $CO_2$ emission by 30[%] of BAU by 2020. Electric power industries in Korea produce most of their electricity by burning fossil fuels, and emit approximately 28[%] of national $CO_2$ emissions. Monitoring the $CO_2$ emissions. Monitoring the $CO_2$ emission of electric power plants is very important. This paper presents a method to calculate the hourly $CO_2$ emission for a thermal power plant burning mixture of coal and oil using the performance test data and coal-oil mix rate. An example of $CO_2$ emission calculation is also demonstrated.

배출량 분포에 따른 대구시 일산화탄소 측정망 위치의 적절성 평가 (Assessment of the Locations for Carbon Monoxide Monitoring Stations in Daegu according to Emission Distribution)

  • 김효정;조완근
    • Spatial Information Research
    • /
    • 제20권2호
    • /
    • pp.25-34
    • /
    • 2012
  • 대구지역은 주위가 산으로 둘러싸인 분지형 도시이기 때문에 대기 환경 쾌적성이 타 도시 보다 낮은 편이다. 따라서 본 연구에서는 대구지역 자동대기오염측정소의 위치를 일산화탄소(CO) 배출량 분포에 기초하여 CO를 체계적으로 관리하기위한 적합한 장소에 대해 조사하였다. 이를 위하여 현재 대구지역 CO 관리정책 수립에 기초자료를 제공하는 자동대기측정소의 위치 적절성에 대하여 평가하였다. 대구시 수치지도와 환경부에서 제공하는 CAPSS(대기정책지원시스템 ; Clean Air Policy Support System) 자료를 활용하여 배출량 지도를 작성하였다. 도로, 아파트, 공장, 소각장 4가지로 구분하여 배출량을 입력한 뒤 법정동별 평균 배출량을 산출하였다. CO 배출지역을 고 배출량 지역과 저 배출량 지역 10단계로 구분하고 현재 측정소가 어느 단계에 해당하는지 조사하였다. 결과적으로, 저 배출량 지역 보다는 CO 고 배출량 지역에 해당하는 측정소가 부족한 것으로 나타났다. 특히, 1999년부터 2007년까지 공통적으로 추가 설치가 필요하다고 나온 국우동 외 6곳에 CO 측정망이 설치된다면 보다 다양한 기초 자료의 제공으로 체계적인 CO 관리가 가능할 것으로 판단된다.