• Title/Summary/Keyword: $CO_2$ fluxes

Search Result 163, Processing Time 0.023 seconds

Study on $CO_2$ Evaporation Heat Transfer and Pressure Drop in a Horizontal Smooth Tube (수평 평활관내 $CO_2$ 증발열전달 및 압력강하에 관한 연구)

  • Lee, Sang-Jae;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.9
    • /
    • pp.615-621
    • /
    • 2007
  • Experimental study on the heat transfer characteristics of $CO_2$ in a horizontal smooth tube was carried out to investigate the heat transfer coefficient and pressure drop during evaporation of $CO_2$. The experiment apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes ($200{\sim}1200kg/m^2s$), heat flukes ($10{\sim}100kW/m^2$) and saturation temperatures (-5, 0, $5^{\circ}C$). With increasing the heat flux, the evaporation heat transfer coefficient increased. But the variation of the heat transfer coefficient on the increase of the mass flux was not large. And the significantly drops of the heat transfer coefficient was observed at any heat flux and mass flux because of the change of the flow pattern in the tube. With increasing the saturation temperature, the heat transfer coefficient increased due to the promotion of a nucleate boiling. The measured pressure drop during evaporation increased with increasing the mass flux and decreasing the saturation temperature.

CO2 and Energy Exchange in a Rice Paddy for the Growing Season of 2002 in Hari, Korea (한국 하리 논에서의 2002년 생장기간의 CO2와 에너지의 교환)

  • Byung-Kwan Moon;Jinkyu Hong;Byoung-Ryol Lee;Jin I. Yun;Eun Woo Park;Joon Kim
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.2
    • /
    • pp.51-60
    • /
    • 2003
  • Rice, which occupies about 60% of the farmland in Korea, is a staple crop in Asia. It not only absorbs $CO_2$ from the atmosphere, but also emits carbon in a form of CH$_4$. It has a potential role in the global budget of greenhouse gases because of its relative contributions of carbon absorption and emission associated with changing hydrologic cycle. To better understand its current and future role, seasonal variations of energy and $CO_2$ exchange in this critical ecosystem need to be quantified. The purpose of this study was to measure, document and understand the exchange of energy and $CO_2$ in a typical rice paddy in Korea throughout the whole growing season. Since late April of 2002, we have conducted measurements of energy and $CO_2$ exchange in a rural rice paddy at Hari site, one of the Korea regional network of tower flux measurement (KoFlux). After the quality control and gap-filling, the observed fluxes were analyzed in the context of micrometeorology and biophysics. $CO_2$ and energy exchanges varied significantly with land cover changes (e.g., plant growth stages), in addition to changes in weather and climate conditions. This study, reporting first direct measurement of energy and $CO_2$ exchange over a rice paddy in Korea, would serve as a useful database as one of the reference sites in AsiaFlux and FLUXNET.

Heat Transfer Characteristics During Gas Cooling Process of Carbon Dioxide in a Horizontal Tube (수평관내 초임계 영역의 Co2 냉각 열전달 특성)

  • Son, Chang-Hyo;Lee, Dong-Gun;Oh, Koo-Kyu;Jeong, Si-Young;Kim, Young-Lyoul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.289-295
    • /
    • 2004
  • The heat transfer coefficient and pressure drop during gas cooling process of carbon dioxide in a horizontal tube were investigated. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flowmeter, an evaporator, and a gas cooler(test section). The main components of the water loop consist of a variable-speed pump, an isothermal tank, and a flowmeter. The gas cooler is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. The test section consists of smooth, horizontal stainless steel tube of the outer diameter of 9.53mm and of the inner diameter of 7.75mm. The length of the test section is 6m. The refrigerant mass fluxes were 200∼300kg/(m2$.$s) and the inlet pressure of the gas cooler varied from 7.5㎫ to 8.5㎫. The main results were summarized as follows : Pressure drop of CO2 increases with increasing gas cooler pressure. The friction factors of CO2 in a horizontal tube show a relatively good agreement with the correlation by Blasius. The heat transfer coefficient of CO2 in transcritical region increases with decreasing gas cooler pressure and decreasing mass flux of CO2. Most of correlations proposed in a transcritical region showed significant deviations with experimental data except for those predicted by Gnielinski.

Heat Transfer and Pressure Drop Characteristics of Supercritical $CO_2$ in a Helically Coiled Tube (초임계 $CO_2$의 헬리컬 코일관 내 열선단과 압력강하 특성)

  • Yu, Tae-Guen;Kim, Dae-Hui;Son, Chang-Hyo;Oh, Hoo-Kyu
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.353-358
    • /
    • 2005
  • The heat transfer and pressure drop of supercritical $CO_2$ cooled in a helically coiled tube was investigated experimentally. The experiments were conducted without oil in the refrigerant loop. The experimental apparatus of the refrigerant loop consist of receiver, a variable speed pump, a mass flowmeter, a pre-heater, a gas cooler(test section) and an isothermal tank. The test section is a helically coiled tube in tube counter flow heat exchanger with $CO_2$ flowed inside the inner tube and coolant( water) flowed along the outside annular passage, It was made of it copper tube with the inner diameter of 4.55[mm]. the outer diameter of 6.35 [mm] and length of 10000 [mm]. The refrigerant mass fluxes were $200^{\sim}600$ [kg/m2s] and the inlet pressure of gas cooler varied from 7.5 [MPa] to 10.0 [MPa]. The main results are summarized as follows : The heat transfer coefficient of supercritical $CO_2$ increases, as the cooling pressure of gas cooler decreases. And the heat transfer coefficient increases with the increase of the refrigerant mass flux. The pressure drop decreases in increase of the gas cooler pressure and increases with increase the refrigerant mass flux.

  • PDF

Study on effect on CO2 flux of wetland soil by feces of Korean water deer(Hydropotes inermis) (고라니(Hydropotes inermis)의 분변이 습지 토양의 CO2 flux에 미치는 영향)

  • Park, Hyomin;Chun, Seunghoon;Lee, Sangdon
    • Journal of Wetlands Research
    • /
    • v.17 no.3
    • /
    • pp.283-292
    • /
    • 2015
  • The total global emission of $CO_2$ from soils is recognized as one of the largest fluxes in the global carbon cycle. Especially it is necessary to quantify the amount of $CO_2$ emitted by the organic material decomposition processes of microorganisms in the soil, because it becomes one of a factor for determining the carbon stocks in the soil. This study was conducted to estimate the impact of the Korean water deer(Hydropotes inermis)' feces to the soil organic matter. Also, effects of Korean water deer' feces on $CO_2$ emissions of soil and land use pattern dependent $CO_2$ flux quantification are studied. The organic materials in the Korean water deer' feces significantly changed organic matter content of soil and influenced the activity of soil microorganisms, both changing of respiration of the soil and physical chemical components in soil. In particular, C/N ratio and the $CO_2$ flux of soil of four regions (Rice paddy, Fallow ground, Salix koreensis community, Phragmites australis community) showed a statistically highly significant correlation (P<0.01) with the presence or absence of feces. $CO_2$ flux of soil affected by the feces was 2-20 times higher than the soil unaffected by the feces. This study has great significance to quantify the extent of the material circulation and its impact to the terrestrial ecosystem and soil zone throughout Korean water deer' feces. Feces of wildlife can affect soil and soil material circulation.

Effects of NaF evaporation rate on the properties of $CuInSe_2$ thin-film solar cells

  • Park, Sun-Yong;Lee, Eun-U;Lee, Sang-Hwan;Park, Sang-Uk;Jeong, U-Jin;Kim, U-Nam;Jeon, Chan-Uk
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.36.2-36.2
    • /
    • 2010
  • A small amount of Na incorporated in $CuInSe_2$ (CIS) absorption layer has become widely accepted as a requirement for efficient polycrystalline CIS solar cells. However, there is ongoing argument on the role of sodium incorporated in the absorber. In this paper, CIS absorption layers have been deposited using the three-stage co-evaporation process on Mo coated non-Alkali glass substrates. The NaF was evaporated during the second-stage with various fluxes. This paper is focusing on differences of micro-structure and composition ratio of the absorber realized with different Na contents and the variation of electrical properties of the cells with the corresponding absorbers. The analytical results of x-ray diffraction (XRD) patterns, field emission scanning electron microscope (FE-SEM), energy dispersive spectroscopy (EDS) and current-voltage characteristics will be discussed to investigate the effect of NaF flux on the CIS absorber formation and its cell performance.

  • PDF

FIR Observations and Simple LVG Modeling Results of L1448-MM

  • Lee, Jin-Hee;Lee, Jeong-Eun;Lee, Seok-Ho;DIGIT Team, DIGIT Team
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.82.2-82.2
    • /
    • 2012
  • We present Herschel-PACS observations of L1448-MM, a Class 0 protostar with a prominent outflow, part of the DIGIT Key Program (PI: N. Evans). We detect numerous emission lines including CO and $H_2O$ rotational transitions, OH transitions, and [OI] forbidden transitions at wavelengths from 55 to 210 ${\mu}m$. The $H_2O$, [OI], mid-J CO (J < 23), and OH emission distributes along the outflow direction although high-J CO and other OH emission peaks at the central spatial pixel. According to our simple excitation analysis, CO seems to have two temperature components of warm and hot, which might be attributed to the PDR and shock, respectively. After exploring a wide range of physical conditions with a non-LTE LVG code, RADEX, we found that either shock alone or the combination of PDR and shock can explain the observations. The relative fraction of observed line luminosities suggest that L1448-MM is shielded from the UV radiation because $H_2O$ and CO are the dominant coolants rather than OH and [OI]. In addition, our observed fluxes match better with C-shock models rather than J-shocks. The non-LTE LVG model supports that the IR pumping process is important for OH transitions because the OH line ratios are fitted much better when the dust thermal continuum is included.

  • PDF

"Dust, Ice, and Gas In Time" (DIGIT) Herschel observations of GSS30-IRS1

  • Je, Hyerin;Lee, Jeong-Eun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.66.2-66.2
    • /
    • 2013
  • As part of the DIGIT key program, we observed GSS30-IRS1, a Class I object located in Ophiuchus (d=125 pc), with Herschel-PACS. More than 70 lines were detected in 50-200 micron band including CO, OH, H2O, and [OI]. All lines, except for [OI], were detected only at the central spaxel of $9.4^{{\prime}{\prime}}{\times}9.4^{{\prime}{\prime}}$ while the [OI] emission is extended along the NE-SW direction. One interesting feature in GSS30-IRS1 is that the continuum is extended beyond PSF, unlike line emission. It suggests that the external heating is important in GSS30-IRS1. For detail analysis of line fluxes, we apply the non-LTE LVG model, RADEX as well as simple rotational diagrams. We also use the Monte Carlo radiative transfer package, RADMC-3D to understand the heating mechanism of dust grains around GSS30-IRS1. We will discuss about heating and cooling processes associated with GSS30-IRS1.

  • PDF

Heat transfer and pressure drop characteristics during cooling process of supercritical $CO_2$ in a horizontal tube (수평관내 이산화탄소의 냉각열전달과 압력강하 특성에 관한 연구)

  • Son, C.H.;Kim, J.R.;Roh, G.S.;Ku, H.G.;Park, G.W.;Oh, H.K.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.244-245
    • /
    • 2005
  • This paper presents the heat transfer and pressure drop characteristics during cooling process of carbon dioxide in a horizontal tube. The test section is a tube in tube type heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. It was made of a stainless steel tube with the inner diameter of 7.75 [mm], the outer 2 diameter of 9.53 [mm] and length of 6000 [mm]. The refrigerant mass fluxes were $200{\sim}400$ [kg/$m^2s$] and the average pressure varied from 7.5 [MPa] to 10.0 [MPa]. The main results were summarized as follows The heat transfer coefficient of supercritical $CO_2$ increases in decrease of the gas cooler pressure. And the heat transfer coefficient increases with respect to the increase of the refrigerant mass flux. Among some correlations proposed in a transcritical region, Bringer-Smith's correlation has some analogy with experimental results. The pressure drop decreases in increase of the gas cooler pressure and increases with respect to increase the refrigerant mass flux.

  • PDF

A Comparison of the Atmospheric CO2 Concentrations Obtained by an Inverse Modeling System and Passenger Aircraft Based Measurement (인버스 모델링 방법을 통해 추정된 대기 중 이산화탄소 농도와 항공 관측 자료 비교)

  • Kim, Hyunjung;Kim, Hyun Mee;Kim, Jinwoong;Cho, Chun-Ho
    • Atmosphere
    • /
    • v.26 no.3
    • /
    • pp.387-400
    • /
    • 2016
  • In this study, the atmospheric $CO_2$ concentrations estimated by CT2013B, a recent version of CarbonTracker, are compared with $CO_2$ measurements from the Comprehensive Observation Network for Trace gases by Airliner (CONTRAIL) project during 2010-2011. CarbonTracker is an inversion system that estimates surface $CO_2$ fluxes using atmospheric $CO_2$ concentrations. Overall, the model results represented the atmospheric $CO_2$ concentrations well with a slight overestimation compared to observations. In the case of horizontal distribution, variations in the model and observation difference were large in northern Eurasia because most of the model and data mismatch were located in the stratosphere where the model could not represent $CO_2$ variations well enough due to low model resolution at high altitude and existing phase shift from the troposphere. In addition, the model and observation difference became larger in boreal summer. Despite relatively large differences at high latitudes and in boreal summer, overall, the modeled $CO_2$ concentrations fitted well to observations. Vertical profiles of modeled and observed $CO_2$ concentrations showed that the model overestimates the observations at all altitudes, showing nearly constant differences, which implies that the surface $CO_2$ concentration is transported well vertically in the transport model. At Narita, overall differences were small, although the correlation between modeled and observed $CO_2$ concentrations decreased at higher altitude, showing relatively large differences above 225 hPa. The vertical profiles at Moscow and Delhi located on land and at Hawaii on the ocean showed that the model is less accurate on land than on the ocean due to various effects (e.g., biospheric effect) on land compared to the homogeneous ocean surface.