• 제목/요약/키워드: $CO_2$ evaluation system

검색결과 633건 처리시간 0.027초

The Energy Analysis and Evaluation of the NEO-Hanok

  • Han, Sang Hee;Park, So Yeon;Park, Hyo Soon
    • KIEAE Journal
    • /
    • 제14권2호
    • /
    • pp.77-86
    • /
    • 2014
  • Plenty of efforts have been made in the traditional architecture of Korea, Hanok, to develop various elements such as restoration, the introduction of new design, and energy-saving while systemic setups on standard and evaluation of eco-friendly energy design of Hanok are lacking. If we evaluate energy performance based on current standards without reflecting unique features of Hanok on the system, Hanok will be included in the very low grade among the residential buildings being included in the approval system of eco-friendly architecture or the unique features will be modified and the burden of increased construction cost. Therefore, this study is to prepare the basic reference for the introductory evaluation system by evaluating the energy performance level of NEO-Hanok based on the current building energy rating system. The result for NEO-Hanok based on the building energy rating system, we propose the rating standard with scorecard elements of NEO-Hanok by considering the necessity of identity and standard for NEO-Hanok. As a result of infiltration test to check the tightness, it was measured as 10.81 times/h (50 ACH). As we switch from the main insulation for the wall from the glass wool 64k(0.035W/mk) to rigid polyurethane foam first class first unit (0.024W/mk), the result was slightly increased from the first demand quantity rating yield $249.8kWh/m^2{\cdot}yr$ to $235.0kWh/m^2{\cdot}yr$. Current certificate system is focused more on the heating load than the cooling load, it is disadvantageous for Hanok, which has less cooling energy consumption in summer. The rating result from the target building study is level 4.

시각 - 촉각 일치된 마중형 햅틱 제시 시스템의 사용자 평가 (User Evaluation of Encountered Type Haptic System with Visual-Haptic Co-location)

  • 차백동;배유성;최원일;류제하
    • 한국HCI학회논문지
    • /
    • 제14권2호
    • /
    • pp.13-20
    • /
    • 2019
  • 산업안전을 위한 가상훈련시스템들 중 마중형 햅틱 제시 시스템에서는 가상 및 실제 물체 사이의 자연스러운 상호 작용을 위해 시각-촉각 일치가 필요하며 이를 위해 캘리브레이션이 수행된다. 본 논문에서는 어느 정도의 시각-촉각 일치를 구현한 몰입형 VR 햅틱 시스템의 사용자 평가를 수행하였다. 평가의 목표는 실제 및 가상환경에서 수행하는 일정한 과업들에 대해 두 환경에 대한 사용자 성능 (반응시간 및 거리 정확도)이 크게 다르지 않다는 것을 보이는 것이다. 사용자 평가 결과는 반응 시간에서 통계적으로 유의한 차이가 보이지만 절대 차이는 1초 미만이며 거리 정확도는 가상 환경과 실제 환경 간에 차이가 없는 것을 보여준다. 따라서 개발된 햅틱가상훈련시스템은 값비싼 실제 환경을 대신하여 저렴하게 산업안전 훈련을 할 수 있다고 사료된다.

PPG 혈당 모니터링 시스템의 분석적 평가 - 연구자 임상 (Analytical Evaluation of PPG Blood Glucose Monitoring System - researcher clinical trial)

  • 박철구;최상기;조성근;김권민
    • 디지털융복합연구
    • /
    • 제21권3호
    • /
    • pp.33-39
    • /
    • 2023
  • 본 연구는 모세관 혈당의 혈당값을 대조군으로 연구 참가자의 혈액 포도당을 모니티링할 때 PPG 센서와 DNN 예측알고리즘이 융합된 혈당모니터링 시스템(PPG-BGMS)의 성능을 평가하는 것이다. 연구는 2023년 9월부터 2023년 11월까지 참가자를 대상으로 실시된 연구자 임상시험이다. PPG-BGMS는 1분간의 심박수, 심박변이도 정보와 DNN 예측알고리즘을 활용한 예측된 혈당수치와 개인용혈당관리시스템의 혈당측정기로 측정한 모세관혈당 수치와 비교했다. 총 100명의 참가자 중 제2형 당뇨(T2DM) 유병인은 50명이며, 평균연령은 67세(28세~89세)이다. PPG-BGMS의 예측혈당의 100%가 Clarke 오류그리드 및 Parker(Consensus) 오류그리드의 A+B 영역에 분포하는 것으로 나타났다. PPG-BGMS 예측 혈당의 MARD 값은 5.3 ± 4.0 %이다. 결과에 의하면 비채혈식 PPG-BGMS는 임상표준의 채혈식 개인용 혈당측정시스템의 순간 혈당수치와 비교하여 열등하지 않는 것으로 분석되었다.

해양생물에 대한 $CO_2$의 영향을 실험하기 위한 문어의 이용 (Experimental Design of Octopus for $CO_2$ Effects on Marine Organisms)

  • 이경선
    • 해양환경안전학회지
    • /
    • 제12권3호
    • /
    • pp.179-183
    • /
    • 2006
  • $CO_2$를 해양에 격리 처리하기 위해서는 $CO_2$가 해양생태계에 어떠한 영향을 미치는가에 대한 연구가 선행되어야 한다. 이 연구에서는 $CO_2$의 해양생물영향실험에 있어 연체동물의 이용가능성을 모색하기 위한 연구로, 먼저 문어에 적합한 마취농도를 확립하고, 혈액을 채취하기 위한 케뉴레이션 방법 및 문어가 케뉴라를 탈착시키는 것을 방지하기 위한 구속 방법에 대해서 검토하였다. 그 결과 1) 문어에 적합한 마취제는 5.25% $MgCl_2\;6H_2O$인 것으로 나타났다. 2) 문어로부터 혈액채취를 위한 케뉴라 삽입 부위는 배대동맥이 적합한 것으로 나타났다. 3) 케뉴라 보호를 위하여 플라스틱 넷트로 만든 구속 쳄버를 이용하는 것이 유용한 것으로 나타났다

  • PDF

주택면적의 변화에 따른 가정용 초소형 연료전지 코제너레이션 시스템의 경제성 분석에 관한 연구 (A Study on the Economic Evaluation with Super-Micro Fuel Cell Home Cogeneration System by Varying the Floor Area of House)

  • 노철우;김민수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.25-28
    • /
    • 2008
  • The fuel cell system is environment-friendly and energy efficient system. Especially, the fuel cell cogeneration systems providing heat and electricity to buildings have been developed and applied to a lot of sites in the world to cope with the global warming and $CO_2$ emission problem. This paper presents the result of study on the economic evaluation with super-micro fuel cell (SMFC) cogeneration system by varying the floor area ($132m^2{\sim}331m^2$) of the house, whose system capacity ranges from 0.10 kWe to 0.50 kWe. The electricity demand, heat demand, saved energy cost, and the simple pay-back period have been simulated for the various capacities of fuel cell cogeneration system. As a result, this study suggests the fuel cell system's capacity decision strategy for a given house area. Contrary to conventional design assumptions, the smaller capacity fuel cell cogeneration system is appropriate for the house of large floor area to defense the progressive electricity tax, and the larger capacity fuel cell cogeneration system is appropriate for the house of small floor area to sell the electricity.

  • PDF

$CO_2$ 용접재의 용접전압과 용접전류에 따른 강도 평가 (Evaluation of Welding strength with welding voltage and current in $CO_2$ Welding Plate)

  • 송준희;문창렬;임재규
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2004년도 춘계 학술발표대회 개요집
    • /
    • pp.261-263
    • /
    • 2004
  • 상용차의 다양한 모델의 변화에 따른 여러 가지 용접부의 이음형태를 가지는 차체부품이 요구됨에 따라 생산성 향상을 위해 용접재의 두께별, 형태별 용접조건의 최적화가 시급히 요구된다$^{1.2)}$ . (중략)

  • PDF

한국형 SPAR(Soil-Plant-Atmosphere-Research) 시스템에서 대용량 관측 자료의 처리 및 품질관리 (Processing and Quality Control of Big Data from Korean SPAR (Soil-Plant-Atmosphere-Research) System)

  • 상완규;김준환;신평;백재경;서명철
    • 한국농림기상학회지
    • /
    • 제22권4호
    • /
    • pp.340-345
    • /
    • 2020
  • 본 연구에서는 첨단 옥외환경조절시설인 SPAR 시스템의 작물 및 환경 관측 자료의 품질 관리와 보증 방법을 최초로 제시하였다. 특히 실시간 군락 CO2플럭스의 경우에는 수집되는 자료의 특성을 고려하여 이상치의 제거와 보정이 병행되어야 함을 확인하였다. 본 연구를 통해 구축된 자료 처리 방법들은 향후 SPAR 자료를 통한 작물 생육 모형 개선에 매우 중요하게 활용될 수 있을 것으로 보인다. SPAR 내 작물과 환경 관련 10분 평균 자료는 국립식량과학원 내 작물 연구 통합 정보시스템(Crop Research Information System, CRIS) 웹사이트(www2.nics.go.kr/cris)에서 이용 가능하다.

평판형 수소생산시스템의 수소개질 성능평가 (The performance evaluation for H2 reforming of the plate type hydrogen generation system)

  • 허수빈;윤봉석;이도형
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권6호
    • /
    • pp.602-608
    • /
    • 2014
  • 저탄소 친환경 대체 에너지의 한 분야인 수소에너지는 화석연료의 개질 및 물의 전기분해 등 다양한 방법을 통해 얻어진다. 수소를 연료로 사용하는 연료전지인 PEMFC용 1kW급 평판형 수소생산시스템을 자체 개발하였다. FEMFC는 CO에 의한 오염에 민감하므로 공급되는 개질가스 중에 CO 농도는 10ppm 이하로 제거되어야 한다. 본 연구에서는 다양한 실험조건에서 $H_2$ 및 CO의 농도를 측정하여 최적의 운전조건을 확립하였다. 결과적으로 A/F ratio ${\alpha}=1.3$, STR temperature 1023K, S/C ratio 3, and $PrOx1{\cdot}2$ 30cc/min에서 최적임을 확인하였다. 또한 PrOx 2단이 CO 농도를 줄이는데 더욱 효과적임을 알 수 있었다.

$SF_6$가스절연 변압기 ($SF_6$ Gas Insulated Transformer)

  • 조광제;홍기돈;하영식;조규복;노철웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.304-309
    • /
    • 1991
  • We introduce the trend, of several countries, to the gas insulated transformer recently coming into the spot light by the advantages of less weight, GIS-lization, low noise level and easiness to decrease environmental pollutions, and the insulating gases. the cooling media and the insulating materials used for transformer. Hereinafter, additively the design of proto type $SF_6$ gas insulated transformer (insulation, cooling), which was developed by us(HICO) from 1987. 2 through 1990. 3, the manufacturing processes(leak protection, pressure, drying of main body), the accessories, the protective system, the cooling system, the method and the results of test and the evaluation of economics compared with conventional oil-filled transformer are represented.

  • PDF

지하주차장 내부 일산화탄소 가스 분포의 전산 해석적 평가 (Numerical Evaluation of CO Gas Distribution in Underground Parking Lot)

  • 김재원;함경아
    • 한국전산유체공학회지
    • /
    • 제7권2호
    • /
    • pp.33-42
    • /
    • 2002
  • Numerical estimation for concentration of mono-carbon oxygen (CO) gas inside an underground parking lot with auxiliary jet fans for enhancement of ventilation is carried out by using a commercial program. Main interest lies on the diagnosis of the present ventilation system including position and selection of auxiliarly fans in addition to main suppliers and exhausts. Details of both flows and concentration of CO gas that is most important component among car exhaust gases are illustrated in this investigation and those are presented for engineering construction of an underground parking pool. Prediction data of computational work is also validated by real measurements of concentration of CO gas.