• Title/Summary/Keyword: $CO_2$ emission reduction

Search Result 629, Processing Time 0.025 seconds

THE NEW DEUTZ ENGINE FAMILY 2013 FOR COMMERCIAL VEHICLES

  • Mikulic, L.;Pleimling, H.;Pfeifer, A.;Lingens, A.
    • International Journal of Automotive Technology
    • /
    • v.2 no.4
    • /
    • pp.135-145
    • /
    • 2001
  • DEUTZ AG, co-founded in 1864 by Nicolaus August Otto, the inventor of the four-stroke cycle engine, has developed the new 2013 engine for commercial vehicles on the basis of the tried and tested 1012 and 1013 series. With 4 and 6 cylinder models, the engine covers the power range between 100 and 190 kW. At the time of their introduction to the market, the engines will meet the exhaust emission legislation of EURO IV and incorporate the potential for EURO IV, Further engineering targets were. (Compactness, Favourable power/cost relation, Low weight, Low fuel consumption and Low noise level). All targets could be accomplished in a relatively short development period via the application of modem simulation tools and test methods. In this paper, the design configuration of the engines is described with particular emphasis on measures for noise emission reduction and the combustion system including injection and turbo charging. Furthermore, we demonstrate the engine's potential to fullfill the European emission legislation EU4, which comes into force in 2005.

  • PDF

Influence of Biomass Co-firing on a Domestic Pulverized Coal Power Plant In Terms of CO2 Abatement and Economical Feasibility (다양한 바이오매스 혼소시 국내 미분탄화력에 미치는 이산화탄소 감축 및 경제성 영향 분석)

  • Kim, Taehyun;Yang, Won
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.1
    • /
    • pp.14-22
    • /
    • 2017
  • Co-firing of renewable fuel in coal fired boilers is an attractive option to mitigate $CO_2$ emissions, since it is a relatively low cost option for efficiently converting renewable fuel to electricity by adding biomass as partial substitute of coal. However, it would cause reducing plant efficiency and operational flexibility, and increasing operation and capital cost associated with handling and firing equipment of renewable fuels. The aim of this study is to investigate the effects of biomass co-firing on $CO_2$ emission and capital/operating cost. Wood pellet, PKS (palm kernel shell), EFB (empty fruit bunch) and sludge are considered as renewable fuels for co-firing with coal. Several approaches by the co-firing ratio are chosen from previous plant demonstrations and commercial co-firing operation, and they are evaluated and discussed for $CO_2$ reduction and cost estimation.

이산·연속선택모형을 이용한 친환경자동차에 대한 지원정책이 에너지 소비와 CO2 배출에 미치는 영향 분석

  • Gwon, O-Sang;Kim, Yong-Geon;Jeong, Jae-Ho
    • Environmental and Resource Economics Review
    • /
    • v.21 no.2
    • /
    • pp.237-269
    • /
    • 2012
  • This study applies a discrete-continuous choice model to a national survey data set of automobile uses to investigate the potential impacts of a bonus-malus system for new cars in Korea. Not only the impacts on the discrete choice of automobile type and class but also those on the continuous decision making of car operation are analyzed. The characteristics of automobiles and individuals that determine car choice and operation are identified. The simulation based on the estimation result shows that an appropriately designed bonus-malus system can induce a reduction in energy consumption and $CO_2$ emission substantially without additional government expenditure.

  • PDF

Economic Evaluation of Alternatives for CO2 Reduction of Thermal Power Generation Companies using ROPM: Comparing CCS with RPS Implementation (실물옵션을 활용한 화력발전회사의 CO2 감축대안의 경제성 평가: CCS와 RPS 이행의 비교)

  • Lee, Dong Su;Jeong, Kiho
    • Environmental and Resource Economics Review
    • /
    • v.20 no.1
    • /
    • pp.61-98
    • /
    • 2011
  • This study conducts economic evaluation of alternatives for $CO_2$ reduction of thermal power plants. Two alternatives in reducing $CO_2$ emission are considered for the evaluation under the RPS(Renewable Portfolio Standard) system; one is to perform renewable energy quotas and another is to construct green thermal power plants using CCS(Carbon Capture and Sequestration). As evaluation methods, DCF(Discount Cash Flow) and ROPM(Real Options Pricing Method) are employed. At a discount rate of 7.5% applied to the Electricity Supply and Demand Plan, it is shown that green thermal power generation has economic dominance under both evaluation methods.

  • PDF

Analysis of Greenhouse Gas Reduction according to Different Scenarios of Zero Food Waste Residential Buildings (음식물류폐기물 제로화 주거단지 구축 시나리오별 비용 및 환경효과 분석)

  • Oh, Jeong-Ik;Yoon, Eun-Joo;Park, Ire;Kim, Yeong-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.7
    • /
    • pp.353-363
    • /
    • 2016
  • In this study, traditional treatment scenario of food wastes that collected and transported food waste is recycled in large treatment facilities and suggested treatment scenario of onsite zero discharge system that food waste is treated in housing complex were supposed. The scenarios were compared and analyzed by capital expenditure, oil consumption, $CO_2$ emission quantity, operating expenditure and management expenses. The capital expenditure, oil consumption and $CO_2$ emission quantity of small scale dispersion dealing method is the lowest compared to traditional treatment method. As a results, it is possible to obtain the effect that operating expenditure was reduced by 91% and management expenses was reduced by 40% with suggested treatment method. The treatment method that have low capital expenditure is tend to lower oil consumption and $CO_2$ emission quantity. The small scale dispersion dealing method have the lowest capital expenditure, oil consumption and $CO_2$ emission quantity and the linked method with sewage treatment have the highest expenditure and $CO_2$ emission quantity. Eventually, the optimal model of onsite zero discharge system in housing complex is small scale dispersion dealing method.

Combustion Control through the DME Injection Timing in the Hydrogen-DME Partially Premixed Compression Ignition Engine (DME 분사 시기 조절을 통한 수소-DME 부분 예혼합 압축착화 연소 제어)

  • Jeon, Jeeyeon;Bae, Choongsik
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.1
    • /
    • pp.27-33
    • /
    • 2013
  • Hydrogen-dimethy ether(DME) partially premixed compression ignition(PCCI) engine combustion was investigated in a single cylinder compression ignition engine. Hydrogen and DME were used as low carbon alternative fuels to reduce green house gases and pollutant. Hydrogen was injected at the intake manifold with an injection pressure of 0.5 MPa at fixed injection timing, $-210^{\circ}CA$ aTDC. DME was injected directly into the cylinder through the common-rail injection system at injection pressure of 30 MPa. DME inejction timing was varied to find the optimum PCCI combustion to reduce CO, HC and NOx emissions. When DME was injected early, CO and HC emissions were high while NOx emission was low. As the DME injection was retarded, the CO and HC emissions were decreased due to high combustion efficiency. NOx emissions were increased due to the high in-cylinder temperature. When DME were injected at $-30^{\circ}CA$ aTDC, reduction of HC, CO and NOx emissions was possible with high value of IMEP.

Experimental Study on the Effects of Low Viscosity Engine Oils on Fuel Economy (엔진오일의 저점도화가 차량 연비에 미치는 영향에 관한 실험적 연구)

  • Kim, Han-Goo
    • Tribology and Lubricants
    • /
    • v.26 no.5
    • /
    • pp.291-296
    • /
    • 2010
  • The purpose of this paper is to study the fuel economy improvement experimentally when the viscosity of engine oil is lowered. The emissions are measured for CVS-75 mode with SAE viscosity grades. The test results indicate that a close correlation has been found between the engine oil viscosity and the fuel economy. The lowering of engine oil viscosity causes the reduction of friction loss which has a very close relation with the fuel economy. These results as the lowering of engine oil viscosity will be a important factor for improvement of the fuel economy and reduction of the $CO_2$ emission.

A study to find the operation conditions to minimize carbon footprint using a simulator(EQPS) (시뮬레이터(EQPS)를 이용한 탄소발자국 최소화 운전 방안에 대한 연구)

  • Jisoo Han;Jeseung Lee;Byonghi Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.32 no.2
    • /
    • pp.37-48
    • /
    • 2024
  • Wastewater treatment plants (WWTPs) are obligated to reduce carbon emissions as a part of public sector greenhouse gas (GHG) emission reduction targets. However, Sewage Statistics(2022) shows that CO2 emissions per wastewater treatment volumes have decreased by only 3.03 % compared to 2020, which is far from enough to meet the Nationally Determined Contribution (NDC) targets. This study aimed to find operational conditions of biological reactors that minimize total carbon footprint (CFP). Total CFP considers both direct emissions from biological processes and indirect emissions from energy consumption. A study was conducted using a computer simulation program which is called as EQPS for a 4-stage BNR WWTP. The results showed that total CFP was reduced by 10.97% compared to the design condition when the mixed liquor recirculation (MLR) was set to 100 % of the influent flow. The N2O emission factor (EF) of the target WWTP was calculated to be 0.138-0.199 %, which is significantly lower than the IPCC default value of 1.6 %. This study proposes a method to minimize total CFP in WWTPs by optimizing biological reactor operation and emphasizes the need for further research on N2O emission reduction.

A Consideration On The Surface Temperature Reducing Effect Of Green Roof System Flat Roof (옥상녹화 평지붕의 표면온도 저감효과에 대한 고찰)

  • Lee, Doo-Ho;Lee, Eung-Jik
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.83-88
    • /
    • 2012
  • This study analyzed the measured value came out by the field test to verify the surface temperature reduction of the flat roof due to green roof, and confirmed the influence of the green roof based on it, and assessed the possibility of saving structures' energy and reducing $CO_2$ emission of structures. For the actual measurement, the differences of the average atmospheric temperature of the green roof and non-green roof flat roof were $8.67^{\circ}C$ and $0.787^{\circ}C$, and the average floor temperature gaps were $11^{\circ}C$ and $2.008^{\circ}C$ in October and November respectively. It was expected that if it's measured on around summer solstice that the temperature gets higher, the deviation of the surface temperature should be bigger, and it was confirmed that the green roof eventually raises insulating effect of structures and will influence on cooling and heating effects such as energy saving and insulating.

Economic Effects Analysis for Passenger Car's Idle Stop and Go Strategy: Focusing on Seoul Metropolitan Area (승용차 공회전제한장치 장착전략의 경제효과분석: 수도권 지역을 대상으로)

  • Lee, Kyu Jin;Jang, Jeong Ah;Choi, Keechoo;Shim, Sang Woo
    • Journal of Korean Society of Transportation
    • /
    • v.32 no.5
    • /
    • pp.421-430
    • /
    • 2014
  • The greenhouse gas emission generated by idling vehicles is a critical issue in the greenhouse gas reduction from the transportation sector. Recently, the mandatory application of the Idle Stop and Go (ISG) for buses, trucks and taxis is in the process of legislation. Focusing on the regulation is about to apply to passenger cars, this study analyzed the quantitative economic effects of the ISG installation by passenger car types in Seoul metropolitan area to support proper policy making. The benefit cost ratio of ISG installation on commercial passenger car of Seoul is the most effective, calculated as 8.55. Accordingly, the amount of 660 liters (per year per vehicle) of fuel and 1,606 kg (per year per vehicle) of $CO_2$ could be reduced. The results of this study might be used as an index for judgment of policy such as determining appropriate subsidy for ISG installation on passenger cars.