• Title/Summary/Keyword: $CO_2$ Storage

Search Result 1,450, Processing Time 0.029 seconds

Implementation of a Residual Quantity Monitoring System in a Liquefied Gas Storage Tank based on Wireless Sensor Network Technology (무선센서 네트워크 기술 기반 액화가스 저장탱크 내 잔량 모니터링 시스템 구현)

  • Kim, Min-Kyu;Han, Hae-Jin;Han, Jaehwan
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.352-356
    • /
    • 2018
  • This paper relates to a technology for monitoring a liquefied gas storage tank in the special gas field where demand is increasing owing to the continuous growth of related fields such as the semiconductor, display, and ICT convergence electronics industries. We have proposed a system for real - time monitoring using wireless sensor network technology, and implemented a system consisting of a sensor unit, transmitter module, and receiver module to be attached to a liquefied gas storage tank. The system was applied to LCO2 tanks among various liquefied gas storage tanks to verify the feasibility. The storage tanks employed in the experiments has capacities of 16,179 l and was 1,920 mm in inner diameter. Furthermore, the density was 1.03 g/l. The measured data were compared with reference data on the remaining gas level versus the $CO_2$ height of the surface, expressed using a conventional water meter, provided by an existing storage tank supplier. The experimental results show that the data is similar to the standard data provided by the tank supplier, and has a high accuracy and reliability within an error range of 0.03%.

Effect of Storage Conditions of Whole Fruits on Quality of Fresh-cut 'Niitaka' Asian Pears

  • Chung, Hun-Sik;Youn, Kwang-Sup;Moon, Kwang-Deog
    • Food Science and Biotechnology
    • /
    • v.18 no.6
    • /
    • pp.1379-1385
    • /
    • 2009
  • Quality changes of the slices processed from 'Niitaka' Asian pears (Pyrus pyrifolia) stored at $0^{\circ}C$ for up to 4 months under controlled atmosphere (CA, 1% $O_2+1%\;CO_2$) and normal air have been investigated for 4 days at $10^{\circ}C$. Respiration rate of the slices was retarded by pre-slicing storage for 4 months in CA. Electrolyte leakage was lower in the slices from pears stored for short-term than long-term and under CA than air. L and a values of the slices from whole pears stored under CA were maintained higher and lower, respectively as compared to the other. Levels of acetaldehyde and ethanol in the slices were increased by CA and long-term storage of whole pears. Content of ascorbic acid and counts of total aerobic microbes in the slices were not affected by storage conditions of whole pears. These results show that storage atmospheres and durations of whole pears affected quality changes of the slices and the conditions of pre-slicing storage should be considered as an important factor for optimizing fresh-cut procedures.

Volume of Water Storage and Evapotranspiration by Inserted Materials at a Reservoir of Porous Grass Block (저수형 잔디블록 저수조 내 충진재료에 따른 저수량 및 초종별 증발산량)

  • Han, Seung-Ho;Choi, Joon-Soo;Yang, Geun-Mo;Yang, Byoung-E;Kang, Jin-Hyoung;Kim, Won-Tae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.5 s.118
    • /
    • pp.76-83
    • /
    • 2006
  • The purpose of this study was to investigate the performance of porous grass block. For the investigation, Festuca arundinacea and Zoysia japonica 'Zenith' were planted, and the volume of evapotranspiration and remains were examined based on different materials in the water tank in the experiment of Festuca arundinacea, the volume of water storage of treatment with perlite ($10.84{\iota}/m^2$) was higher than that with drainage ($7l/m^2$). The difference between the two was $3.84/m^2$. The drainage treatment without water storage capacity showed the higher degree of dryness in turf grass. The volume of evapo-transpiration of treatment with perlite was the highest (21.57mm/week). The volume of evapotranspiration of treatment with sand was 19.57mm/week, and with treatment with drainage was 18.24mm/week. Based on the measured volume of daily evapotranspiration of $2.60{\sim}3.08mm\;d^{-1}$, it was determined that the unit with water storage capacity would store water of one to two days usage compared to unite without such storage capacity. In the experiment of Zoysia japonica 'Zenith', the volume of water storage of treatment with perlite was $10.77l/m^2$ which was similar to the former experiment. The volume of evapotranspiration of treatment with perlite and sand were 21.64mm/week and 20.64mm/week, respectively. In case of airtight water tank, the volume was measured as 22.06mm/week. Each treatment has no notable difference in the volume of evapotranspiration. In conclusion, from the investigation in this study, porous grass block with water tank was found to be effective in plant growth under low irrigation. As the ecological area ratio and vegetated porous pavement have became more emphasized, additional study of rain infiltration and reservoir effect are needed in the future.

Performance Analysis of an Oxy-fuel Combustion Power Generation System Based on Waste Heat Recovery: Influence of CO2 Capture (배열회수형 순산소연소 발전시스템의 성능해석: CO2 포집의 영향)

  • Tak, Sang-Hyun;Park, Sung-Ku;Kim, Tong-Seop;Sohn, Jeong-Lak;Lee, Young-Duk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.12
    • /
    • pp.968-976
    • /
    • 2009
  • As the global warming becomes a serious environmental problem, studies of reducing $CO_2$ emission in power generation area are in progress all over the world. One of the carbon capture and storage(CCS) technologies is known as oxy-fuel combustion power generation system. In the oxy-fuel combustion system, the exhaust gas is mainly composed of $CO_2$ and $H_2O$. Thus, high-purity $CO_2$ can be obtained after a proper $H_2O$ removal process. In this paper, an oxy-fuel combustion cycle that recovers the waste heat of a high-temperature fuel cell is analyzed thermodynamically. Variations of characteristics of $CO_2$ and $H_2O$ mixture which is extracted from the condenser and power consumption required to obtain highly-pure $CO_2$ gas were examined according to the variation of the condensing pressure. The influence of the number of compression stages on the power consumption of the $CO_2$ capture process was analyzed, and the overall system performance was also investigated.

Effect of Polyethylene Glycol Molecular Weight and NCO Index on Properties of the Hydrophilic Reactive Hotmelt Polyurethane Adhesives (Polyethylene Glycol의 분자량 및 NCO index의 변화에 따른 Hydrophilic Reactive Hotmelt Polyurethane의 물성 변화)

  • Han, Young Chul;Kim, Dack Han;Oh, Kyung Seok;Shin, Hyeon Jeong;Yang, Jeong Han;Jeong, Han Mo
    • Textile Coloration and Finishing
    • /
    • v.30 no.2
    • /
    • pp.90-97
    • /
    • 2018
  • Hydrophilic reactive hot-melt polyurethane adhesive(HRHA) using a hydrophilic polyol having different molecular weight and NCO index was synthesized. This HRHA was synthesized using Polyethylene glycol(PEG) as a hydrophilic polyol, Polypropylene glycol(PPG) and Polycaprolactone diol(PCL) as hydrophobic polyols, and Methylene diphenyl diisocyanate(MDI) as an isocyanate. The changes in IR spectrum, viscosity and thermal properties of HRHA with different PEG molecular weights and NCO index were investigated, and the tensile strength and elongation of the HRHA casting film and the peel strength, moisture permeability and water pressure of the HRHA coated fabric were confirmed. In this experiment, as the molecular weight of PEG and NCO index increased, the adhesive strength, tensile strength, elongation and moisture permeability was increased but viscosity and Tg was decreased.

Studies on the Preparation of Digestive Enzyme Tablest (IV) (소화효소제(消化酵素劑)의 제조(製造)에 관(關)한 연구(硏究) 제4보(第4報))

  • Kim, Yong-Bae;Kim, Whan-Hoe;Yi, Pyong-Kuk;Shin, Hyun-Jong
    • Journal of Pharmaceutical Investigation
    • /
    • v.8 no.4
    • /
    • pp.23-36
    • /
    • 1978
  • Since the active center of digestive enzymetic preparations, while under storage, lose their activity and potency by the exposure to moisture, colorization, solidifying and other physical changes. It is more important than beautiful package form that protected packaging form from moisture to get a pharmaceutical safety preparations and to maintain a definite potency. Then, in order to get a desirable conditions of storage and packaging, we used shellac and $AEA^{\circledR}$ as a coating base, and blister package, foil and bottle container as a packaging material. Temperature were set on room temperature and $37^{\circ}C$, moisture was adjusted to 40% RH and 80 % RH as a accelerated conditions. Accelerated test was carried out 6 times. The results are as follows: 1) The effect of packaging conditions give great influence on the maintenace of the stable potency. 2) Best result was produced with bottle container package. 3) $AEA^{\circledR}$ is more useful than shellac as a coating base of prevention from moisture. 4) Absorption of moisture gave considerable effects on potency and it has a limited point. 5) Difference in potency between optimal and worst condition is 472 u/2T, and difference in effective period is about 44 months.

  • PDF

Behavior Analysis of Discharged DIC Concentrated Seawater through Towed Pipe Injection from Ship

  • Kwon, Seong-Min;Kim, Kang-Min;Song, Hyeon-Woo;Lee, Joong-Woo
    • Journal of Navigation and Port Research
    • /
    • v.43 no.2
    • /
    • pp.79-85
    • /
    • 2019
  • Climate change is a very vital issue that can be no longer avoided. Korea has been a top-level country Iin dealing with carbon dioxide emissions since 1960. Many studies have been conducted to suppress or eliminate carbon dioxide emissions, which account for a large portion of greenhouse gases. Carbon Capture and Storage (CCS), the most practical method of them, plays a significant role. However, these methods have the disadvantage of the limits of geographical distribution and high possibility of re-emission into the atmosphere. Recently, ocean storage has been studied using Accelerated Weathering of Limestone (AWL), a technique for storing carbon dioxide in the ocean as an alternative to CCS, an underground storage. AWL is a method of converting carbon dioxide into concentrated water in the form of bicarbonate ion and discharging it to the ocean to dilute and store it. It does not cause re-emission to the atmosphere, and the discharged concentrated water increases the alkalinity of the ocean to prevent marine acidification. The objective of this study was to understand the behavior of DIC (Dissolved Inorganic Carbon) including carbon dioxide during the ocean discharge of bicarbonate ion concentrated water in AWL method. This study area was set near Ulleung-do where sufficient water depth and operational efficiency were secured. CORMIX model was used to calculate the material diffusion by submerged discharge using ship.

A Simulation Analysis on the Validity of Color Rescheduling Storage in an Automobile Painting Shop (자동차 도장공장의 Color Rescheduling Storage 설치를 위한 시뮬레이션 분석)

  • Moon, Dug-Hee;Kim, Ha-Seok;Song, Cheng;Kim, Kyung-Wan
    • IE interfaces
    • /
    • v.16 no.2
    • /
    • pp.211-221
    • /
    • 2003
  • This paper introduces a simulation study regarding the design for the installation of Color Rescheduling Storage (CRS) in an automobile factory. In the painting shop the colors of vehicles are changed frequently according to the assembly schedule. When the color of a vehicle is changed from one to another, the cleaning process of painting-gun is necessary and it generates costs. Therefore many of the automobile manufacturers equip the CRS in front of the Top Coat Booth of the painting shop. The major objective of CRS is to reduce the change over cost in the painting process by grouping vehicles having same color. In this paper the configuration of CRS and the input/output algorithms are explained. The suggested system is verified using simulation models and experiments are conducted. Finally the best alternative is suggested by sensitivity analysis and evaluation of investment feasibility.

Thermal Analysis of a Spent Fuel Storage Cask under Normal and Off-Normal Conditions (사용후핵연료 저장용기의 정상 및 비정상조건에 대한 열해석)

  • Ju-Chan Lee;Kyung-Sik Bang;Ki-Seog Seo;Ho-Dong Kim;Byung-Il Choi;Heung-Young Lee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.13-22
    • /
    • 2004
  • This study presents the thermal analyses of a spent fuel dry storage cask under normal and off-normal conditions. The environmental temperature is assumed to be 15 $^{\circ}C$ under the normal condition. The off-normal condition has an environmental temperature of 38 $^{\circ}C$. An additional off-normal condition is considered as a partial blockage of the air inlet ducts. Two of the four air inlet ducts are assumed to be completely blocked. The significant thermal design feature of the storage cask is the air flow path used to remove the decay heat from the spent fuel. Natural circulation of the air inside the cask allows the concrete and fuel cladding temperatures to be maintained below the allowable values. The finite volume computational fluid dynamics code FLUENT was used for the thermal analysis. The maximum temperatures of the fuel rod and concrete overpack were lower than the allowable values under the normal and off-normal conditions.

  • PDF

An Evaluation of Chiller Control Strategy in Ice Storage System for Cost-Saving Operation (운전비 절감을 위한 빙축열시스템 냉동기 운전기법 평가)

  • Lee, Kyoung-Ho;Choi, Byoung-Youn;Lee, Sang-Ryoul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.2
    • /
    • pp.97-105
    • /
    • 2008
  • This paper presents simulated and experimental test results of optimal control algorithm for an encapsulated ice thermal storage system with full capacity chiller operation. The algorithm finds an optimal combination of a chiller and/or a storage tank operation for the minimum total operation cost through a cycle of charging and discharging. Dynamic programming is used to find the optimal control schedule. The conventional control strategy of chiller-priority is the baseline case for comparing with the optimal control strategy through simulation and experimental test. Simulation shows that operating cost for the optimal control with chiller on-off operation is not so different from that with chiller part load capacity control. As a result from the experimental test, the optimal control operation according to the simulated operation schedule showed about 14 % of cost saving compared with the chiller-priority control.