• Title/Summary/Keyword: $CO_2$ Saturation

Search Result 355, Processing Time 0.024 seconds

Evaluation on the Aggressivity of Drinking Water for Corrosion Control in Water Distribution System (상수도관로의 부식 방지를 위한 수돗물의 침식성 평가)

  • Kwak, Phill-Jae;Lee, Hyun-Dong;Nam, Sang-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.53-63
    • /
    • 1997
  • The corrosion problems in water distribution system are reduced by decreasing the agressivity of drinking water which is evaluated by marble test and saturation indices(LSI or CCPP etc.). Marble test is a reliable method to determine the actual saturation condition of treated water. This study was done to determined the aggressivity of tap water and the effectiveness of $Ca(OH)_2$ and NaOH dosage for corrosion control. The drinking water in Seoul were evaluated by marble test and Langelier Index(LSI) and Calcium Carbonate Precipitation Potential(CCPP). The results indicated that the drinking water in Seoul were undersaturated as Calcium Carbonate($CaCO_3$). The LSI and CCPP of the water treated with $Ca(OH)_2$ were higher than that of water treated with NaOH. Therefore, to increase the Alkalinity and Calcium Hardness for corrosion control in water distribution system, $Ca(OH)_2$ is more effective than NaOH.

  • PDF

Synthesis and Magnetic Property of Nanocrystalline Fe-Ni-Co Alloys during Hydrogen Reduction of Ni0.5Co0.5Fe2O4 (Ni0.5Co0.5Fe2O4의 수소환원에 의한 나노구조 Fe-Ni-Co 합금의 제조 및 자성특성)

  • Paek, Min Kyu;Do, Kyung Hyo;Bahgat, Mohamed;Pak, Jong Jin
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.2
    • /
    • pp.167-173
    • /
    • 2011
  • Nickel cobalt ferrite($Ni_{0.5}Co_{0.5}Fe_2O_4$) powder was prepared through the ceramic route by the calcination of a stoichiometric mixture of NiO, CoO and $Fe_2O_3$ at $1100^{\circ}C$. The pressed pellets of $Ni_{0.5}Co_{0.5}Fe_2O_4$ were isothermally reduced in pure hydrogen at $800{\sim}1100^{\circ}C$. Based on the thermogravimetric analysis, the reduction behavior and the kinetic reaction mechanisms of the synthesized ferrite were studied. The initial ferrite powder and the various reduction products were characterized by X-ray diffraction, scanning electron microscopy, reflected light microscope and vibrating sample magnetometer to reveal the effect of hydrogen reduction on the composition, microstructure and magnetic properties of the produced Fe-Ni-Co alloy. The arrhenius equation with the approved mathematical formulations for the gas solid reaction was applied to calculate the activation energy($E_a$) and detect the controlling reaction mechanisms. In the initial stage of hydrogen reduction, the reduction rate was controlled by the gas diffusion and the interfacial chemical reaction. However, in later stages, the rate was controlled by the interfacial chemical reaction. The nature of the hydrogen reduction and the magnetic property changes for nickel cobalt ferrite were compared with the previous result for nickel ferrite. The microstructural development of the synthesized Fe-Ni-Co alloy with an increase in the reduction temperature improved its soft magnetic properties by increasing the saturation magnetization($M_s$) and by decreasing the coercivity($H_c$). The Fe-Ni-Co alloy showed higher saturation magnetization compared to Fe-Ni alloy.

MAGNETIC PROPERTIES OF Co-FERRITE FILMS BY SOLID REACTION AT LOW TEMPERATURE

  • Chiba, Masafumi;Uemura, Chikao;Arima, Hiroshi;Koizumi, Yoshiharu
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.659-662
    • /
    • 1995
  • Co-ferrite ($CoO-Fe_{2}O_{3}$) thin films have been prepared by two ways of low temperature solid reaction including oxidation process, being based on $Co-layer/{\alpha}-Fe_{2}O_{3}$ films and $Co-layer/Fe_{3}O_{4}$ films. Magnetic properties of both Co-ferrite films have been measured and compared. The samples from $Co-layer/Fe_{3}O_{4}$ films have a large coercive force in the direction perpendicular and have a great poler kerr rotation angle at wavelength 700 nm than ones from $Co-layer/{\alpha}-Fe_{2}O_{3}$ films. The typical magnetic properties are as follows; saturation magnetization $4{\pi}Ms$, 2.9 kG; remnant magnetization $4{\pi}Mr$, 2.0 kG; coercive force Hc, 4.0 kOe; kerr rotation angle ${\PHI}k$, 0.39 deg($\lambda\;=\;700\;nm$); and initial magnetization energy E, $3.3\;{\times}\;10^6\;erg/\textrm{m}^3$, respectively.

  • PDF

Electrical Resistivity Monitoring of Gas Hydrate Formation (가스하이드레이트 형성 과정의 비저항 모니터링)

  • Lee, J.Y.;Lee, J.H.;Lee, D.S.;Lee, W.S.;Kim, S.J.;Huh, D.G.;Kim, H.T.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.186-187
    • /
    • 2008
  • Electrical resistivity in hydrate-bearing sediments is sensitive to porosity, gas hydrate saturation, gas content, pore fluid composition, and temperature, so electrical measurements such as well logs and electromagnetic surveys have been used to explore gas hydrate-bearing formation. The high pressure tomography cell is designed considering the effect of electrode configuration and electrical shielding on tomography measurements and the safety. The evolution of electrical conductivity during $CO_2$ hydrate formation and dissociation reflects the combined effects of concurrent changes that include ionization of dissolved $CO_2$, temperature-dependent ionic mobility, changes in the degree of saturation, ion exclusion, surface conduction, and porosity changes. Measurements during hydrate formation and dissociation require careful analysis to properly interpret signatures, in particular when out-of plane conductivity anomalies prevail.

  • PDF

The Effect of Ba and Fe Concentration on Soft Magnetic Properties of Z-Type Barium Ferrite (Z-Type 바리움 페라이트 분말의 연자성 특성에 미치는 Ba 및 Fe 농도의 영향)

  • Cho, Kwang-Muk;Nam, In-Tak
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.1
    • /
    • pp.12-16
    • /
    • 2009
  • Z-type barium ferrite [($Ba_{3}Co_{0.8}Zn_{1.2}Fe_{24}O_{41}$, $Ba_{3+{\delta}}Co_{0.8}Zn_{1.2}Fe_{24}O_{41}$ ${\delta}$ = 3, 5, 7, 13 wt%. $Ba_{3}Co_{0.8}Zn_{1.2}Fe_{24+{\delta}}O_{41}$ ${\delta}$ = 5, 7, 10 wt% )] were synthesized using co-precipitation method. The microstructure and magnetic properties of synthesized particles were investigated. In all prepared particles M-type Ba ferrite is identified with Z-type Ba ferrite together. It is found that particles having 7 wt% for Ba and 5 wt% for Fe excess addition revealed high saturation magnetization, respectively. All synthesized particles showed relatively high coercivity for device application. This result may be attributed to the contribution of M-type Ba ferrite. Ba and Fe excess addition was not affected to the structural change of CoZnZ Ba ferrite. The certain amount of excess additions of Ba and Fe and the 2 step heat-treatment may be beneficial to the improvement of soft magnetic properties of Z-type barium hexa-ferrite

Hemodynamics Effects of $CO_2$ Insufflation During Thoracoscopy (흉강경시 $CO_2$에 의한 혈역학적 영향)

  • 손동섭;원경준
    • Journal of Chest Surgery
    • /
    • v.29 no.7
    • /
    • pp.723-727
    • /
    • 1996
  • An adequate exposure is important in thoracoscopic procedures. The insufflation of $CO_2$has been demonstrated to aid in compressing lung parenchyma, and act as a retractor when combined with changes in patient's position. However, a recent study demonstrated that $CO_2$insufflation during thoracoscopy in the pig has adverse hemodynamic consequences. We prospectively studied 12 patients undergoing thoracoscopy to evaluate the effect of $CO_2$insufflation in the clinical setting. The mean arterial pressure, heart rate, central venous pressure, arterial oxygen saturation, and end-tidal $CO_2$pressure were monitored. Measurements were determined at baseline, at the initiation of one-lung ventilation, and at intrapleural pressure of 5, 10, 15 mmHg and following results were obtained. 1) The insufflation of 5 to 15 mmHg of $CO_2$had no significant effect on the mean arterial pressure, heart rate, arterial oxygen saturation. 2) The end-tidal $CO_2$pressure rose from 31.00$\pm$1.67 mmHg to 38.49$\pm$1.82 mmHg at an intrapleural pressure of 15 mmHg(p<0.05). 3) The central venous pressure rose from 7.75$\pm$0.76 mmHg to 12.83$\pm$1.64 mmHg and 16.16$\pm$l.97mmHg at an intrapleural pressure of 10 and 15 mmHg(p<0.05). 4) The low pressure (<10 mmHg) insufflation is a safe adjunct to the conduct of thoracoscopic surgical procedures.

  • PDF

A Review on Ocean Acidification and Factors Affecting It in Korean Waters (우리나라 주변 바다의 산성화 현황과 영향 요인 분석)

  • Kim, Tae-Wook;Kim, Dongseon;Park, Geun-Ha;Ko, Young Ho;Mo, Ahra
    • Journal of the Korean earth science society
    • /
    • v.43 no.1
    • /
    • pp.91-109
    • /
    • 2022
  • The ocean is a significant sink for atmospheric anthropogenic CO2, absorbing one-third of the total CO2 emitted by human activities. In return, oceans have experienced significant declines in seawater pH and the aragonite saturation state also called ocean acidification. This study evaluates the distribution of aragonite saturation state, an indicator to assess the potential threat from ocean acidification, by combining newly obtained data from the west coast of South Korea with previous datasets covering the Yellow Sea, East Sea, northern South China Sea, and southeast coast of South Korea. In general, offshore waters absorb atmospheric CO2; however, most of the collected water samples show aragonite oversaturation. On the southeast coast, the aragonite saturation state was significantly affected by river discharge and associated variables, such as freshwater input with nutrients, seasonal stratification, biological carbon fixation, and bacterial remineralization. In summer, hypoxia and mixing with relatively acidic freshwater made the Jinhae and Gwangyang Bays undersaturated with respect to aragonite, possibly threatening marine organisms with CaCO3 shells. However, widespread aragonite undersaturation was not observed on the west coast, which receives considerable river water discharge. In addition, occasional upwelling events may have worsened the ocean acidification in the southwestern part of the East Sea. These results highlight the importance of investigating site-specific ocean acidification processes in coastal waters. Along with the above-mentioned seasonal factors, the dissolution of atmospheric CO2 and the deposition of atmospheric acidic substances will continue to reduce the aragonite saturation state in Korean waters. To protect marine ecosystems and resources, an ocean acidification monitoring program should be established for Korean waters.

Changes in Chlorophyll Contents and Photosynthetic Characteristics of Hardwood Species According to Artificial Shade Treatment

  • Choi, Jeong-Ho;Kwon, Ki-Won;Chung, Jin-Chul
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.5
    • /
    • pp.614-620
    • /
    • 2006
  • To study the chlorophyll contents and photosynthetic characteristics of 4 tree species of deciduous hardwoods; Betula platyphylla var. japonica, Zelkova serrata, Acer mono and Prunus sargentii were treated in 3 stages of shading; the full sun treatment, the medium shade treatment with 30% of transmittance comparing to full sun, the intense shade treatment with 8% of transmittance and their changes in chlorophyll contents and photosynthetic characteristics were examined and analyzed. Most hardwoods showed differences in the total chlorophyll contents in the order of May < September < July, however, that in Prunus sargentii increased progressively along with the lapse of time. Concerning the degree of shading, total chlorophyll contents increased in proportion to the level of shading. Betula platyphylla var. japonica and Prunus sargentii showed more than 2-3 times difference between the full sun treatment and the intense shade treatment. The changes in photosynthetic characteristics, the range of the light saturation point of the trees was $1,000{\sim}1,100{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ in May, before the shading was applied, and the intensity was shown in the order of Betula platyphylla var. japonica > Zelkova serrata > Acer mono > Prunus sargentii. The photosynthetic rate was $6.4{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}{\sim}27.1{\mu}mol{\cdot}CO_2{\cdot}m^{-2}{\cdot}s^{-1}$ in the order of Betula platyphylla var. japonica > Prunus sargentii > Acer mono > Zelkova serrata that there were differences between species. Concerning the changes in light saturation point in each growth period after shading treatment, the light saturation point in the full sun treatment was found in the range of $560{\sim}1,100{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ and the level of intensity was shown in the order of May > July > September. The light saturation point decreased as the level of shading intensified and the level of changes in light compensation point in the full sun treatment for Betula platyphylla var. japonica and Prunus sargentii was shown in the range of $2.9{\sim}27.1{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ in the order of May > July > September, however, for Zelkova serrata and Acer mono was shown in the range of $3.9{\sim}11.7{\mu}mol{\cdot}CO_2{\cdot}m^{-2}{\cdot}s^{-1}$ in the order of July > May > September that there were differences between species.

Evaporative Heat Transfer Characteristics of Carbon Dioxide in a Horizontal Tube (수평관내 이산화탄소의 증발 열전달 특성)

  • Son Chang-Hyo;Lee Dong-Gun;Kim Young-Lyoul;Oh Hoo-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1134-1139
    • /
    • 2004
  • The evaporative heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of inner diameter of 7.75 mm. The experiments were conducted at mass flux of 200 to 500 kg/m$^2$s, saturation temperature of -5 to 5$^{\circ}C$, and heat flux of 10 to 40kW/m$^2$. The test results showed the heat transfer of $CO_2$ has a greater effect on nucleate boiling more than convective boiling. Mass flux of $CO_2$ does not affect nucleate boiling too much, and the effect of mass flux on evaporative heat transfer of $CO_2$ is much smaller than that of refrigerant R-22 and R-134a. In comparison with test results and existing correlations, correlations failed to predict the evaporative heat transfer coefficient of $CO_2$, therefore, it is necessary to develope reliable and accurate predictions determining the evaporative heat transfer coefficient of $CO_2$ in a horizontal tube.

EFFECT OF SUPPLEMENTARY INTRANASAL MIDAZOLAM ON ORAL SEDATION OF CHILDREN (미다졸람의 비강 내 추가투여가 소아의 경구 진정요법에 미치는 영향)

  • Jang, Su-Young;Kim, Ji-Yeon;Park, Ki-Tae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.1
    • /
    • pp.11-16
    • /
    • 2012
  • Effect of supplementary intranasal midazolam on oral sedation of children The purpose of this study was to compare the cardiopulmonary parameters of two sedation regimens during dental treatment: (1) Oral chloral hydrate(CH) and hydroxyzine(HZ) with nitrous oxide-oxygen($N_2O/O_2$) inhalation(CH-HZ group); (2) Oral chloral hydrate(CH) and hydroxyzine(HZ) with nitrous oxide-oxygen($N_2O/O_2$) inhalation and supplementary intranasal(IN) midazolam administration(MIDA group). Among the patients of OO hospital who received dental treatment under sedation over the past 5 years, 44 patients were selected for each group of CH-HZ and MIDA according to their age, gender and weight. Following parameters that were recorded every 5 minutes were compared: 1) Heart rate(HR) 2) $O_2$ saturation 3) End tidal carbon dioxide concentration($EtCO_2$) 4) Respiratory rate(RR) 33 patients of Group MIDA who have complete data of 15 minutes before and after supplementary IN midazolam administration were selected. And measurements 15 minutes before and after midazolam administration in same patient were evaluated. The results were as follows: 1. Heart rate was significantly higher in MIDA group than in CH-HZ group, but it was within normal range. 2. Comparing HR, $O_2$ saturation, EtCO2, RR between before and after of supplementary IN midazolam administration in the same patient, the differences were not statistically significant.