• Title/Summary/Keyword: $CA_6$ composites

Search Result 45, Processing Time 0.023 seconds

Low temperature and dieletric properties of $Al_2O_3$/CAS glass composites by dose and particle size of $Al_2O_3$ filler and sintering time ($Al_2O_3$ 충전제의 함량, 입도 및 소결시간에 따른 $Al_2O_3$/CAS glass 복합체의 저온 소결 및 유전 특성)

  • Kim, Kwan-Soo;Kim, Myung-Soo;Yoon, Sang-Ok;Park, Jong-Guk;Kim, So-Jung;Kim, In-Tae;Kim, Shin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.176-176
    • /
    • 2009
  • Influences of dose and particle size of $Al_2O_3$ filler and sintering time on the dielectric properties of $Al_2O_3$ filler/CaO-$Al_2O_3-SiO_2$ (CAS) glass composites were investigated with a view to applying the composites to the substrate material in low temperature co-firing ceramic (LTCC) technology. The increased addition of $Al_2O_3$ filler with the particle size of 1 ${\mu}m$ monotonically decreased the density of the sintered specimen at a given temperature, while sintering of the 10 wt% $Al_2O_3$ added specimen at $925^{\circ}C$ for 2 h demonstrated 96.0 % of the relative density, dielectric constant of 6.34, and quality factor of 2,760 GHz. As for the influence of the particle size of the $Al_2O_3$ filler, there existed an optimum particle size (30 ${\mu}m$) to ensure successful densification (96.5 %) of the 10 wt% $Al_2O_3$/CAS composites at $925^{\circ}C$ for 2 h, at which condition the specimen demonstrated dielectric constant of 5.45 and quality factor of 3,740 GHz. When the influence of the sintering time of the 10 wt% $Al_2O_3$) (30 ${\mu}m$) added specimen was investigated at the sintering temperature of $925^{\circ}C$, an overly long sintering time degraded dielectric properties due to the over-sintering and the significant growth of the second phase such as anorthite, while the sintering for 4 h demonstrated 96.58 % of the relative density, dielectric constant of 5.4, and quality factor of 4,050 GHz. These results demonstrate the feasibility of the investigated material as the substrate material in LTCC technology.

  • PDF

Microstructure and Mechanical Properties of Ti-35Nb-7Zr-XCPP Biomaterials Fabricated by Rapid Sintering

  • Woo, Kee-Do;Park, Sang-Hoon;Kim, Ji-Young;Kim, Sang-Mi;Lee, Min-Ho
    • Korean Journal of Materials Research
    • /
    • v.22 no.3
    • /
    • pp.150-154
    • /
    • 2012
  • Ti-6Al-4V ELI (Extra Low Interstitial) alloy have been widely used as alternative to bone due to its excellent biocompatibility, although it still has many problems such as high elastic modulus and toxicity. Therefore, biomaterials with low elastic modulus and non toxic characteristics have to be developed. A novel ${\beta}$ Ti-35wt%Nb-7wt%Zr-Calcium pyrophosphate (CPP) composite that is a biocompatible alloy without elemental Al or V was fabricated by spark plasma sintering (SPS) at $1000^{\circ}C$ under 70 MPa using high energy mechanical milled (HEMM) powder. The microstructure and phases of the milled powders and the sintered specimens were studied using SEM, TEM, and XRD. Ti-35wt%Nb-7wt%Zr alloy was transformed from ${\alpha}$ phase to ${\beta}$ phase in the 4h-milled powder by sintering. The sintered specimen using the 4h-milled powder showed that all the elements were distributed very homogeneously and had higher density and hardness. ${\beta}$ Ti alloy-CPP composite, which has nanometer particles, was fabricated by SPS using HEMMed powder. During the sintering process, $CaTiO_3$, TixOy, and CaO were formed because of the reaction between Ti and CPP. The Vickers hardness of the composites increases with the increase of the milling time and the addition of CPP. The biocompatibility of the Ti-Nb-Zr alloys was improved by addition of CPP.

Dielectric Properties Dependent on Cross-1inking Agent in Silicone Rubber (실리콘고무의 가교제 변화에 의한 유전특성)

  • Kwon, B.H.;Lee, S.I.;Hong, J.W.;Lee, J.U.;Lee, W.J.
    • Elastomers and Composites
    • /
    • v.22 no.1
    • /
    • pp.20-28
    • /
    • 1987
  • The characteristic of the dielectric relaxation in silicone rubbers were studied in the frequency range of $1{\times}10^2{\sim}3{\times}10^6Hz$ at the temperature range of $30^{\circ}{\sim}170^{\circ}C$. As the results of the study, it has been confirmed that the silicone rubber containing the cross-linking agants of 2,5-bis(tert-butylperoxy)-2, 5-dimethyl hexane exhibit the dissipation spectra of two kind(${\alpha},\;{\beta}$ dissipation) due to the siloxane and methyl groups. Particularly, the maximum value of dielectric loss spectra of silicone rubber combinning the cross-linking agents of 0.7phr to 1.0phr are on the increasing in high frequency region, but the specimen of above 1.0phr become smaller again. The energy and the entropy of activation on the molicular motion obtained 18.32 kcal/mole and $1.48ca1/mole{\cdot}deg$ in measuring condition respectively.

  • PDF

Mechanical properties of sheet molding compounds (SMC) with different size and contents of ground calcium carbonate (중질 탄산칼슘의 입자크기 및 첨가량 변화에 따라 제조된 시트몰딩 컴파운드(SMC)의 기계적 특징)

  • Lee, Yoonjoo;Koh, Kwang-Woon;Kwon, Woo-Teck;Kim, Younghee;Shin, Dong-Geun
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.84-91
    • /
    • 2017
  • Fiber reinforced plastic (FRP) is a typical plastic composite which is fabricated using fiber reinforcement with resin to represent the high strength properties. The mechanical properties of FRP should be determined by a fibrous material, and the studies about the role of fiber as a reinforcement has been an interested subject, whereas a study along the effect of filler is not so big. However, the filler effect must be considered on the properties of the composite, because the filler influence on the plastic or resin compound which reacts as a matrix material of the composite. Thus, in this work, we studied the filler effect with size and content using $3-6{\mu}m$ of ground calcium carbonate. The specimen was prepared by sheet molding compound (SMC) method, and the mechanical properties were compared with bending strength and tensile strength. As a result, it was confirmed that the size and contents of calcium carbonate affected the strength of composites, and the condition of $2.8{\mu}m$ which was the smallest size condition showed the highest strength.

MICROLEAKAGE OF MICROFILL AND FLOWABLE COMPOSITE RESINS IN CLASS V CAVITY AFTER LOAD CYCLING (Flowable 및 microfill 복합레진으로 충전된 제 5급와동에서 load cycling 전,후의 미세변연누출 비교)

  • Kang, Suk-Ho;Kim, Oh-Young;Oh, Myung-Hwan;Cho, Byeong-Hoon;Um, Chung-Moon;Kwon, Hyuk-Choon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.142-149
    • /
    • 2002
  • Low-viscosity composite resins may produce better sealed margins than stiffer compositions (KempScholte and Davidson, 1988: Crim, 1989). Plowable composites have been recommended for use in Class V cavities but it is also controversial because of its high rates of shrinkage. On the other hand, in the study comparing elastic moduli and leakage, the microfill had the least leakage (Rundle et at. 1997) Furthermore, in the 1996 survey of the Reality Editorial Team, microfills were the clear choice for abfraction lesions. The purpose of this study was to evaluate the microleakage of 6 compostite resins (2 hybrids, 2 microfills, and 2 flowable composites) with and without load cycling. Notch-shaped Class V cavities were prepared on buccal surface of 180 extracted human upper premolars on cementum margin. The teeth were randomly divided into non-load cycling group (group 1) and load cycling group (group 2) of 90 teeth each. The experimental teeth of each group were randomly divided into 6 subgroups of 15 samples. All preparations were etched, and Single bond was applied. Preparations were restored with the following materials (n=15) : hybrid composite resin [Z250(3M Dental Products Inc. St. Paul, USA), Denfil(Vericom, Ahnyang, Korea)], microfill [Heliomolar RO(Vivadent, Schaan, Liechtenstein), Micronew(Bisco Inc. Schaumburg, IL, USA)], and flowable composite[AeliteFlo(Bisco Inc. Schaumburg, IL, USA), Revolution(Kerr Corp. Orange, CA, USA)]. Teeth of group 2 were subjected to occlusal load (100N for 50,000 cycles) using chewing simulator(MTS 858 Mini Bionix II system, MTS Systems Corp. Minn. USA). All samples were coated with nail polish 1mm short of the restoration, placed in 2% methylene blue for 24 hours, and sectioned with a diamond wheel. Enamel and dentin/cementum margins were analyzed for microleakage on a sclale of 0 (no leakage) to 3 (3/3 of wall). Results were statistically analyzed by Kruscal-Wallis One way analysis, Mann-Whitney U-test, and Student-Newmann-Keuls method. (p = 0.05) Results : 1. There was significantly less microleage in enamel margins than dentinal margins of all groups (p<0.05) 2. There was no significant between six composite resin in enamel margin of group 1. 3. In dentin margin of group 1, flowable composite had more microleakage than others but not of significant differences. 4. there was no significant difference between six composite resin in enamel margin of group 2. 5. In dentin margin of group 2, the microleakage were R>A =H=M>D>Z. But there was no significant differences. 6. In enamel margins, load cycling did not affect the marginal microleakage in significant degree. 7. In enamel margins, load cycling did affect the marginal microleakage only in Revolution. (p<0.05).