• Title/Summary/Keyword: $C^0$ element

Search Result 836, Processing Time 0.028 seconds

Finite Element Analysis of Combustion Reaction on Iron and Metal Oxides Interface (Fe-금속 산화물 계면에서 연소반응의 유한 요소해석)

  • Gu, Mun-Seon;Choe, Yong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.118.2-118.2
    • /
    • 2017
  • Combustion behavior of Fe, CuO, NiO, ZnO and $Fe_2O_3$ powder mixture was carried out by finite element method (FEM) to understand a reaction at iron and metal oxide interface. The FEM was done by using ANSYS Fluent 17.0. Initial and boundary conditions are 1 atmosphere, room temperature, 0.1MPa of oxygen partial pressure, $T_{S1}=1127^{\circ}C$, $T_{S2}=327^{\circ}C$ for a cylindrical shape specimen with dia. $35{\times}80$ [mm]. The maximum combustion temperature is $1537^{\circ}C$ for the condition of conduction, convection and radiation. The combustion temperature and rate are about $847^{\circ}C$ and 3.9mm/sec, respectively. The combustion wave is enough to make ternary ferrite phase like $CuNiZnFe_2O_3$.

  • PDF

Notched Strength Analysis of CRALL Materials by FEM (I) (FEM에 의한 CRALL재의 노치강도 해석(I))

  • Yoon, Han-Ki
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.2 s.32
    • /
    • pp.41-50
    • /
    • 1999
  • As for the properties on both the aluminum and the CFRP which are used to make A17075/CFRP multi-layered hybrid composites, CRALL(carbon reinforced aluminum laminate). In the CRALL specimen for rule of mixture, we were analyzed notched strength by finite element method. The results obtained from FEM analysis are as follows; In the unnotch CRALL specimen, the stresses CFRP, epoxy, Al 7075 obtained by finite element method strength solution for A/C0001, when strain is 0.28%, are 1400MPa, 38MPa, 411MPa. respectively and for A/C9991, when strain 0.48%, are 392MPa, 26MPa and 321Mpa, respectively. the solpe of the stress-strain curve by FEM increases in keeping with the hole size and the yield strain decrease to 36% and 55% for A/C9993 and A/C9991 respectively.

  • PDF

Effects of Carbides on Hydrogen-induced Delayed Fracture for the Energy Saving Wire (ESW) (선조철강의 탄화물에 따른 수소지연파괴 거동 분석)

  • Lee, J.B.;Kang, N.H.;Park, J.T.;Ahn, S.T.;Park, Y.D.;Cho, K.M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.139-141
    • /
    • 2009
  • This study analyzed the effect of the microstructure and alloying element on hydrogen-induced delayed fracture properties for the Energy Saving Wire (ESW) developed recently. Specimens were produced with a diameter 6.5mm post to the deformation (0, 10, 20 and 30%), followed by injecting the hydrogen. The experimental results by using GAS chromatography showed that the more hydrogen was emitted for high-carbon steel (0.45%C steel and 0.35%C steel) than low-carbon steel(0.2%C-Cr steel and 0.2%C-Cr-Mo steel). And, 0.45%C steel, 0.35%C steel and 0.2%C-Cr-Mo steel exhibited the crack for 30% deformed specimen. The hydrogen emitted was analyzed with the amount, the spheroidization, and the size of the carbides.

  • PDF

Study on Characteristics of Sn-0.7wt%Cu-Xwt%Re Solder (Sn-0.7wt%Cu-Xwt%Re 솔더의 특성에 관한 연구)

  • Noh, Bo-In;Won, Sung-Ho;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.4
    • /
    • pp.21-25
    • /
    • 2007
  • In this study, the properties of Sn-0.7wt%Cu-Xwt%Re(X=$0.01{\sim}1.0$) older were investigated by using DSC(differential scanning calorimetry), wetting balance, victors hardness and tensile testers. The melting temperature of solder was increased with increasing the contents of rare earth element, and the melting temperature range of Sn-0.7Cu-($0.01{\sim}1.0$)Re solder was $233.9{\sim}234.7^{\circ}C$. The wettability with Sn-0.7Cu-0.1Re solder was higher than that of Sn-0.7Cu-0.01Re and Sn-0.7Cu-1.0Re solders, and the wettability of Sn-0.7Cu-0.1Re solder was higher than that of Sn-0.7wt%Cu-0.01w%P solder. Also, the hardness and tensile strength of solder were increased with increasing the contents of rare earth element.

  • PDF

Effect of Additive, Storage Temperature and Time on the Texture Properties of Baikseolgi (첨가물, 저장온도 및 저장시간에 따른 백설기의 텍스쳐 특성)

  • Kim, Myung-Hwan
    • Applied Biological Chemistry
    • /
    • v.41 no.6
    • /
    • pp.437-441
    • /
    • 1998
  • The effects of sucrose fatty acid ester (SE, 1% w/w) and glycerin (GL, 1% v/w) additions, storage temperature$(0,\;20\;and\;70^{\circ}C)$, and time $(0{\sim}6\;day)$ on texture properties, hardness(H), cohesiveness(O), chewiness(C) and rheological property(R) of Baikseolgi were studied. The H of Baikseolgi increased sharply in the early stage of storage at 0 and $20^{\circ}C$, while increased gently at $70^{\circ}C$ with increasing storage time. After 6 days of storage, the H of Baikseolgi at $20^{\circ}C$ had a little lower than that at $0^{\circ}C$. However, the H of Baikseolgi at $70^{\circ}C$ was 10.7% of that at $0^{\circ}C$. The addition of GL had greater effect on the reduction of H than that of SE. The H of control, SE and GL additions were 336, 216 and $$174\;g_f, respectively, after 6 days at $70^{\circ}C$. The O of Baikseolgi at $70^{\circ}C$ were higher than those at $0^{\circ}C$. The O of GL added Baikseolgi had the highest value and the second and the third were SE added and control, respectively. The O of Baikseolgi decreased with increasing storage time. The C of Baikseolgi of increased with increasing storage time, which had similar curve patterns to the H of Baikseolgi. Instantaneous stress and equilibrium stress of Baikseolgi decreased with increasing storage temperature. The affection of viscous element increased and that of elastic element decreased with increasing storage temperature.

  • PDF

Design of drawing process of 9Ni-4Co-0.3C steel to make a large pressure vessel (대형 압력용기 제작을 위한 9Ni-4Co-0.3C 강의 드로잉공정 설계에 관한 연구)

  • Hong Jin Tae;Lee Seok-Ryul;Kim Kyung Jin;Yang Dong Yol;Lee Kyung Hun;Choi Moon Sun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.12 s.177
    • /
    • pp.93-99
    • /
    • 2005
  • In this work, computer-aided process design is carried out to develop an optimal preform of a pressure vessel. Knowledge-based rules are employed to design the preform, and they are formulated using the handbooks of plasticity theories. In the FE-analysis, a commercial finite element code, ABAQUS was employed. Axisymmetric deep drawing of a hemisphere-bottomed cup has been analyzed fur various combinations of die design parameters. The length of the land of die, the clearance between punch and die and the clearance between the blank holder and die are optimized to minimize the forming load. The results of the simulations are verified with the experiments which are scaled down to one tenth of the actual size.

AN ERDŐS-KO-RADO THEOREM FOR MINIMAL COVERS

  • Ku, Cheng Yeaw;Wong, Kok Bin
    • Bulletin of the Korean Mathematical Society
    • /
    • v.54 no.3
    • /
    • pp.875-894
    • /
    • 2017
  • Let $[n]=\{1,2,{\ldots},n\}$. A set ${\mathbf{A}}=\{A_1,A_2,{\ldots},A_l\}$ is a minimal cover of [n] if ${\cup}_{1{\leq}i{\leq}l}A_i=[n]$ and $$\bigcup_{{1{\leq}i{\leq}l,}\\{i{\neq}j_0}}A_i{\neq}[n]\text{ for all }j_0{\in}[l]$$. Let ${\mathcal{C}}(n)$ denote the collection of all minimal covers of [n], and write $C_n={\mid}{\mathcal{C}}(n){\mid}$. Let ${\mathbf{A}}{\in}{\mathcal{C}}(n)$. An element $u{\in}[n]$ is critical in ${\mathbf{A}}$ if it appears exactly once in ${\mathbf{A}}$. Two minimal covers ${\mathbf{A}},{\mathbf{B}}{\in}{\mathcal{C}}(n)$ are said to be restricted t-intersecting if they share at least t sets each containing an element which is critical in both ${\mathbf{A}}$ and ${\mathbf{B}}$. A family ${\mathcal{A}}{\subseteq}{\mathcal{C}}(n)$ is said to be restricted t-intersecting if every pair of distinct elements in ${\mathcal{A}}$ are restricted t-intersecting. In this paper, we prove that there exists a constant $n_0=n_0(t)$ depending on t, such that for all $n{\geq}n_0$, if ${\mathcal{A}}{\subseteq}{\mathcal{C}}(n)$ is restricted t-intersecting, then ${\mid}{\mathcal{A}}{\mid}{\leq}{\mathcal{C}}_{n-t}$. Moreover, the bound is attained if and only if ${\mathcal{A}}$ is isomorphic to the family ${\mathcal{D}}_0(t)$ consisting of all minimal covers which contain the singleton parts $\{1\},{\ldots},\{t\}$. A similar result also holds for restricted r-cross intersecting families of minimal covers.

Characteristics of Piezoelectric and Dielectric of PMWN-PZT Ceramics (PMWN-PZT계 압전세라믹의 압전 및 유전 특성)

  • 홍종국;이종섭;채홍인;윤만순;정수현;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.188-191
    • /
    • 2000
  • The properties of piezoelectric and dielectric for 0.05Pb(Mn$\_$0.4/W$\_$0.2/Nb$\_$0.4/)O$_3$ - 0.95PbZr$\_$x/Ti$\_$1-x/O$_3$ compositions have been investigated. In the composition of 0.05Pb(Mn$\_$0.4/W$\_$0.2/Nb$\_$0.4/)O$_3$ - 0.95PbZr$\_$0.51/Ti$\_$0.49/O$_3$, the values of k$\_$p/ and $\varepsilon$$\_$33/$\^$T// $\varepsilon$$\_$0/ are maximized, but Q$\_$m/ was minimized (k$\_$p/=56.5[%], Q$\_$m/=1130, d$\_$33/=258[pC/N], $\varepsilon$$\_$33/$\^$T// $\varepsilon$$\_$0/=1170). The grain size was suppressed and the uniformity of grain was improved at the 1100[˚C]. Also, we can see the dielectric constants variations between the before poling and after poling. This effect results from the effect(increase element of dielectric constants) between dipole switching and electrostriction inducing stress and dipole direction to the poling orientation(decrease element of dielectric constants). At x=0.51, we can find MPB(morphotropic phase boundary).

  • PDF

Round robin analysis to investigate sensitivity of analysis results to finite element elastic-plastic analysis variables for nuclear safety class 1 components under severe seismic load

  • Kim, Jun-Young;Lee, Jong Min;Park, Jun Geun;Kim, Jong-Sung;Cho, Min Ki;Ahn, Sang Won;Koo, Gyeong-Hoi;Lee, Bong Hee;Huh, Nam-Su;Kim, Yun-Jae;Kim, Jong-In;Nam, Il-Kwun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.343-356
    • /
    • 2022
  • As a part of round robin analysis to develop a finite element elastic-plastic seismic analysis procedure for nuclear safety class 1 components, a series of parametric analyses was carried out on the simulated pressurizer surge line system model to investigate sensitivity of the analysis results to finite element analysis variables. The analysis on the surge line system model considered dynamic effect due to the seismic load corresponding to PGA 0.6 g and elastic-plastic material behavior based on the Chaboche combined hardening model. From the parametric analysis results, it was found that strains such as accumulated equivalent plastic strain and equivalent plastic strain are more sensitive to the analysis variables than von Mises effect stress. The parametric analysis results also identified that finite element density and ovalization option in the elbow elements have more significant effect on the analysis results than the other variables.

An Experimental Study for the Effect of Operating Condition of the Air Handling Unit on the Performance of Humidifying Elements (공조기 운전 조건이 가습 소자의 성능에 미치는 영향에 대한 실험 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.326-331
    • /
    • 2018
  • Evaporative humidification using a humidifying element is used widely for the humidification of a building or a data center. The performance of a humidifying element is commonly expressed as the humidification efficiency, which is assumed to be independent of the air temperature or humidity. To verify this assumption, a series of tests were conducted under two air conditions - data center ($25^{\circ}C$ DBT, $15^{\circ}C$ WBT) and commercial building ($35^{\circ}C$ DBT, $21^{\circ}C$ WBT) - using humidifying elements made from cellulose/PET and changing the frontal air velocity from 1.0 m/s to 4.5 m/s. Three samples having a 100 mm, 200 mm, or 300 mm depth were tested. The results showed that the humidification efficiency is dependent on the air condition. Indeed, even dehumidification occurred at the inlet of the humidifying element at the air condition of commercial building. This suggests that a proper thermal model should account for the inlet area, where the amount of moisture transfer may be different from the other part of the humidification element. As the depth of the element increased from 100 mm to 200 mm, the humidification efficiency increased by 29%. With further increases to 300 mm, it increased by 42%. On the other hand, the pressure drop also increased by 47% and 86%.