• Title/Summary/Keyword: $30^{\circ}$ left inclination

Search Result 5, Processing Time 0.022 seconds

A COMPARATIVE STUDY ON THE RECORDINGS OF MANDIBULAR MOVEMENT (운동의 기록방법에 관한 비교 연구)

  • Shin, Sang Yong;Kim, Kwang Nam;Chang, Ik Tai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.125-146
    • /
    • 1990
  • The relationale for recording mandibular movement is to accurately adjust an articulator. Techniques to record mandibular movement include radiographic interpretation, extraoral tracing, and intraoral recording materials. This study was performed to compare the concylar guidance inclination and Bennett shift(immediate & progressive side shift)obtained by using an electronic pantograph, pantograph and wax interocclusal records in Korean. Ten adults who have normal occlusion and are free of TMJ dysfunction were selected and clutches were constructed. At first Pantronic survey was performed three times by using an kinematic hinge axis according to manufacturer's direction. Next pantographic survey was performed three times and the articulator was adjusted with each pantographic recording. And then maxillary cast was attached to the articulator with pantographic as a face-bow and the mandibular cast was mounted to the articulator with centric relation record. Three protrusive, three left lateral and three right lateral wax interocclusal records were taken on the subjects and the articulator was adjusted with each interocclusal record. Protrusive condylar inclination, lateral condylar inclination, immediate side shift and progressive side shift obtained by using electronic pantograph, pantograph and wax interocclusal record were compared and analized. The results were as follows; 1. The average left and right protrusive and orbiting condylar inclination($33.7^{\circ},\;37.1^{\circ},\;40.6^{\circ},\;43.5^{\circ}$) record with Pantronic was significantly greater than that recorded with other methods. 2. The average left and right protrusive and orbiting condylar inclination($24.8^{\circ},\;27.0^{\circ},\;31.4^{\circ},\;32.4^{\circ}$)recorded with wax interocclusal record was less than that of other methods. 3. The average left and right immediate side shift(0.57mm,0.44mm)recorded with wax interocclusal record was greater than that of other methods and the average left rigtht immmediate side shift(0.30mm,0.41mm)recorded with Pantronic was significantly greater than that recorded with pantograph(0.11mm,0.20mm). 4. The average variance of wax interocclusal was signivicantly higher than that of other methods.

  • PDF

The Physical Characteristics of 119 EMTs and a Comparison of the Quality in Chest Compressions according to Posture in Pregnant Women Cardiac Arrest -A Mannequin Model lying with a 30° Incline to the Left- (119구급대원의 신체적 특성과 심정지 임신부 자세에 따른 가슴압박 질 비교 -30° 왼쪽 기울기 자세의 마네킨 모델-)

  • Park, Dae-Sung
    • Journal of Digital Convergence
    • /
    • v.13 no.11
    • /
    • pp.197-204
    • /
    • 2015
  • This study aims to identify the effects: quality of chest compressions, height and weight of pregnant women cardiac arrest while lying $30^{\circ}$ inclined to the left has on the quality of chest compressions administered by 119 EMT. For the purpose of this study, 62 members of 119 EMTs in M, N, S, Y cities and G cities of J province agreed to join in the test and the test was conducted from June 15 to 16 in 2015. Two mannequins (Resusci Anne$^{(R)}$) were used for the study and the chest compression process was recorded with the use of the Laerdal PC Skill Reporting System$^{(R)}$. As a result, it was discovered that for patients with a $30^{\circ}$ left inclination, who were below 170 cm in height and 65 kg in weight, the proper frequency and depth of compression were unsatisfactory. With this in mind, training programs and instruments that can improve the quality of chest compressions depending on a person's (patient's) height and weight should be developed.

Fishing Mechanism of Pots and their Modification 1. Behavior of Conger Eel, Astroconger myriaster, to the Bamboo and Plastic Pots (통발어구의 어획기구 및 개량에 관한 연구 1. 대통발과 플라스틱통발에 대한 붕장어의 행동)

  • KIM Dae-An;KO Kwan-Soh
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.4
    • /
    • pp.341-347
    • /
    • 1987
  • The behavior of conger eel, Astroconger myriaster (Brevoort), to the bamboo and plastic pots with baits was investigated alternately in two experimental water tanks. One of the pots being dropped on the tank bottom, the eels touched it to obtain the bait probably by their sense of smell, and increased rapidly in the number of touch to show a maximum within 30 minutes. But the touch was made mainly to the pot wall at which the bait was located and quite accidentally to the pot mouth. The eels touched the pot mouth retreated frequently without attempting to enter the pot and their entering was very hampered by the bamboo funnel constituting the pot mouth. However, a entering, if made, encouraged other touches and the touches ascribed other enterings. But, if 30 minutes elapsed, the number of touch decreased gradually and so the enterings were little made. The ability of pots attracting the eels into them was varied with their inclination to the tank bottom and the bait position in them. That is, the pot which was laid horizontally showed high ability of attracting in case in which the bait was fixed in the vicinity of its mouth. The pot, inclined by $30^{\circ}$ by lifting its tail and had a bait left free, showed almost equal ability to the horizontal pot with a bait in the vicinity of mouth. But the pot, inclined by $30^{\circ}$ by lifting its mouth and had a bait left free, showed a very low attracting. A comparison between the bamboo and plastic pots gave only that the entering of the eels became later several minutes in the latter.

  • PDF

Anthropometric Analysis of Frontal Sinus Using 3D CT in Koreans (한국인 성인 남녀에서 3차원 전산화단층촬영술을 이용한 전두동의 형태학적 연구)

  • Shim, Byung-Kwan;Kim, Jun-Hyuk;Shin, Ho-Seong;Lee, Young-Man
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.594-601
    • /
    • 2011
  • Purpose: The frontal sinuses are a pair of triangularly shaped, air-filled chambers lined by mucoperiosteum and located between the inner and outer tables of the frontal bone. Until recently, our understanding of gender variations in craniofacial anatomy has been chiefly built upon anthropometric studies, which typically employ facial surface measurements or plain film radiography. The aim of this study i to determine the sizes of the frontal sinus in both sexes in Koreans. Methods: 95 Korean subjects who underwent maxillofacial 3-Dimensional computed tomography (CT) between January 2009 and December 2009 were enrolled. Frontal sinus dimensions and forehead measurements were taken at midline and at 10, 20, and 30 mm to the left and right of midline using sagittal, coronal, and axial images. The data was analyzed for significant differences between measurements made at the selected points in the frontal sinus, for left to right variations, for gender variations, and for racial differences. Results: The mean thickness of the anterior table ranged from 2.31 to 3.23 mm. Mean anteroposterior depth of the frontal sinus ranged from 7.38 to 9.45 mm and did not vary significantly at any distance from midline. Frontal sinus height was greatest at midline (mean=29.24 mm) and progressively lessened at lateral distances. Mean total width at the level of the supraorbital ridge was 53.66 mm. For all measurements, no significant left to right variation was noted. Comparing the sexes, males were found to have greater dimensions in most frontal sinus measurements, though these differences were only found to be significant at or close to midline. The male forehead was marked by more acute nasofrontal angle ($133.3^{\circ}$ versus $141.6^{\circ}$) and a steeper posterior forehead inclination ($14.9^{\circ}$ versus $7.7^{\circ}$). Conclusion: Using CT imaging, forehead and frontal sinus dimensions have been described. Generally, males had larger overall frontal sinus dimensions. And Korean had similar sized frontal sinus to Caucasian in height and width. But in AP distance Korean had lesser measurement. The result of this study may be helpful in the comprehension of normal size of frontal sinus in Korean.

The Measurement of Normal Talus in Korean Cadaver (한국인 사체에서의 정상 거골의 실측)

  • Ha, Dong-Jun;Gwak, Heui-Chul;Kim, Jeon-Gyo;Kim, Jung-Han;Lee, Chang-Rak;Kim, Young-Jun;Lee, Jeong-Han;Ha, Byung-Ho;Kim, Ui-Cheol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.20 no.4
    • /
    • pp.163-169
    • /
    • 2016
  • Purpose: To investigate the measured values of the talus in Koreans. Materials and Methods: We measured 88 tali from 44 cadavers that have been donated between December 2012 and December 2015. Of the cadavers, 27 were male and 17 were female. Their mean age was 73 years. The length and width of the talus were measured using a digital goniometer and vernier caliper. Results: The values of cadaveric measurement, mean maximal width and length, width and length of the dome anterior, width and length of the posterior facet, height and length of the trochlear medial facet, and height and length of the trochlear lateral facet were $43.6{\pm}2.6mm$, $56.5{\pm}3.3mm$, $32.5{\pm}2.0mm$, $42.2{\pm}2.7mm$, $22.2{\pm}2.2mm$, $34.7{\pm}2.0mm$, $15.3{\pm}1.3mm$, $33.3{\pm}2.9mm$, $25.3{\pm}3.3mm$, and $30.8{\pm}2.4mm$ for men and $38.9{\pm}1.6mm$, $53.6{\pm}2.4mm$, $27.9{\pm}2.1mm$, $37.4{\pm}3.2mm$, $20.6{\pm}0.8mm$, $31.9{\pm}1.2mm$, $13.6{\pm}2.6mm$, $28.4{\pm}2.5mm$, $24.9{\pm}2.1mm$, and $28.9{\pm}1.4mm$ for women, respectively. The size of the talus showed an accuracy of 86% when anteroposterior diameter was greater than 59 mm. A difference in the size of the right and left talus was not observed. The mean inclination and declination angles were $24.4^{\circ}{\pm}4.2^{\circ}$ and $28.2^{\circ}{\pm}5.4^{\circ}$ for men, and $24.6^{\circ}{\pm}3.6^{\circ}$ and $24.7^{\circ}{\pm}6.7^{\circ}$ for women (p=0.980, p=0.018), respectively, at least $15^{\circ}$, which showed a big difference for every object up to $37^{\circ}$. Conclusion: This paper, to the best of our knowledge, is the first study to measure the talus in Koreans. There were differences by gender and ethnicity in the in measured talus values. The measurements were smaller than European-Americans and greater than Japanese.