• Title/Summary/Keyword: $2{\times}$ magnification

Search Result 134, Processing Time 0.027 seconds

Development of the Dot Sight Device by Using the Doublet Reflector (Doublet 반사경을 이용한 도트 사이트 장치의 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.65-69
    • /
    • 2008
  • Purpose: To develop a dot sight device for a sighting shot using the doublet reflector. Methods: We designed the singlet reflector and the doublet reflector by Sigma 2000 program and compared the one to the other. Results: In analysis of finite ray aberration, we could confirm that it has the effective field of view with the free-parallax which is 3.3 times wider than the existing dot sight device using the singlet reflector. If you use the doublet reflector, the central thickness of optical system become more than two times bigger than the existing one. As a result, when the image of a target object is made on the observer's retina, if you make the first side's radius of curvature equal with the second one as the case of the singlet reflector, changes in magnification are appeared. To conquer this problem, we had to make be satisfied with the afocal condition in the case of doublet reflector. Conclusions: we could develop the dot sight device for a sighting shot using the doublet reflector which has the effective field of view with the free-parallax which is 3.3 times wider than the existing dot sight device using the singlet reflector.

  • PDF

Evaluation of Marginal and Internal Gap of Temporary Prosthesis Fabricated by 3D Printing Method According to Rinsing Method and Rinsing Time (세척 방법 및 세척 시간에 따른 3D 프린팅 방식으로 제작된 임시 보철물의 변연 및 내면 적합도 평가)

  • Ji-Hyeon Bae;Jae-Won Choi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.561-570
    • /
    • 2023
  • This study was to evaluate the effect of different rinsing times and methods on the accuracy of temporary prostheses fabricated by 3D printing method. Sixty temporary prostheses were fabricated with LCD types of 3D printer(Halot-Sky, Creality, Shenzhen, China) and divided into six groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5 and 10 min using three methods-hand washed, ultrasonic cleaning, and automated washing. All specimens were polymerized for 3 minutes under the same conditions. The marginal and internal gaps of specimens were examined using a replica technique. The light-body silicone thickness was measured at 6 reference points(Absolute marginal discrepancy, Marginal, Chamfer, Axial, Angle, and Occlusal gap). All measurements were performed by a stereomicroscope. Reference point images were taken at 100× magnification and then measured using an image analysis program. Statistical analysis was performed using Two-way ANOVA, One-way ANOVA, and the Kruskal-Wallis test (p = .05). The marginal and internal gaps were statistically different according to the rinsing methods and rinsing times(p < .001). In the rinsing time, the temporary prosthesis rinsed for 5 minutes group showed higher accuracy than 10 minutes group. In the rinsing method, the hand washing group showed higher accuracy than the automated washing group.

A Comparative Study on the Marginal Fit between Castable Ceramic(Dicor) Crowns and Metal-Ceramic Crowns (주조도재관과 도재전장주조관의 치경부 변연적합도에 관한 비교 연구)

  • Kim, Jeong-Ho;Yang, Jae-Ho;Lee, Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.26 no.1
    • /
    • pp.51-61
    • /
    • 1988
  • The recently introduced castable glass ceramics incorporate properties characteristic of natural teeth and they are regarded as an ideal material to restore lost tooth structure. The purpose of this study was to compare the marginal fit of castable ceramic crown with that of the metal-ceramic crown in the process of heat treatment. Two master dies for castable ceramic crowns and metal-ceramic crowns were fabricated from being cast with the base metal. Each master die was duplicated with addition silicone and hard stone. Ten castable ceramic crowns were made on each hard stone die and their marginal openings were measured three times first, after casting; second, after ceramming; third, after shading. The other ten metal-ceramic crowns were made on each hard stone die and their marginal openings were measured three times : first, after casting; second, after degassing; third, after porcelain veneering. Each crown was seated on its master die with the constant force delivered by loading jig. And then, marginal openings were measured on four locations by optical projector at X50 magnification. The results were as follows: 1. The mean marginal openings of castable ceramic crowns were $31.1{\pm}12.7{\mu}m$ after casting; $44.6{\pm}12.8{\mu}m$ after ceramming; $51.2{\pm}16.8{\mu}m$ after shading. 2. The mean marginal openings of the metal-ceramic crowns were $26.2{\pm}13.8{\mu}m$ after casting; $29.8{\pm}10.3{\mu}m$ after degassing; $38.0{\pm}14.5{\mu}m$ after porcelain veneering. 3. There was significant increase in the marginal opening of castable ceramic crowns after ceramming, while metal-ceramic crowns sho(wed significant increase after porcelain veneering (p<0.05). 4. Marginal fit of metal-ceramic crown was better than that of castable ceramic crown (p<0.01).

  • PDF

In vivo assessment of accuracy of Propex II, Root ZX II, and radiographic measurements for location of the major foramen

  • Tampelini, Fernanda Garcia;Coelho, Marcelo Santos;de Azevedo Rios, Marcos;Fontana, Carlos Eduardo;Rocha, Daniel Guimaraes Pedro;Pinheiro, Sergio Luiz;da Silveira Bueno, Carlos Eduardo
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.3
    • /
    • pp.200-205
    • /
    • 2017
  • Objectives: The aim of this in vivo study was to assess the accuracy of 2 third-generation electronic apex locators (EALs), Propex II (Dentsply Maillefer) and Root ZX II (J. Morita), and radiographic technique for locating the major foramen (MF). Materials and Methods: Thirty-two premolars with single canals that required extraction were included. Following anesthesia, access, and initial canal preparation with size 10 and 15 K-flex files and SX and S1 rotary ProTaper files, the canals were irrigated with 2.5% sodium hypochlorite. The length of the root canal was verified 3 times for each tooth using the 2 apex locators and once using the radiographic technique. Teeth were extracted and the actual WL was determined using size 15 K-files under a ${\times}25$ magnification. The Biostat 4.0 program (AnalystSoft Inc.) was used for comparing the direct measurements with those obtained using radiographic technique and the apex locators. Pearson's correlation analysis and analysis of variance (ANOVA) were used for statistical analyses. Results: The measurements obtained using the visual method exhibited the strongest correlation with Root ZX II (r = 0.94), followed by Propex II (r = 0.90) and Ingle's technique (r = 0.81; p < 0.001). Descriptive statistics using ANOVA (Tukey's post hoc test) revealed significant differences between the radiographic measurements and both EALs measurements (p < 0.05). Conclusions: Both EALs presented similar accuracy that was higher than that of the radiographic measurements obtained with Ingle's technique. Our results suggest that the use of these EALs for MF location is more accurate than the use of radiographic measurements.

Evaluation of Validity Thyroid Scintigraphy Using Parallel Hole Collimator (갑상샘 신티그래피 검사 시 평행다공형 조준기 적용의 유효성 평가)

  • Su-Young Park;Ji-Youn Kim;Sung-Min Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.27-36
    • /
    • 2024
  • In this study, When acquisition thyroid scintigraphy images, a parallel hole collimator was applied, and the difference from the pinhole collimator was quantitatively analyzed under each image acquisition condition. Visual size, resolution, sensitivity, signal to noise ratio (SNR), and contrast to noise ratio (CNR) were evaluated using thyroid phantom and point source. When comparing visual size, it was confirmed that an image similar to the size of the pinhole collimator could be obtained only when a magnification ratio of about 2.00 to 2.09 times when applying a parallel hole collimator. There was no tendency in FWHM(mm) measurement using a point source, and sensitivity was high in the parallel hole collimator. SNR and CNR were high when using a low magnification ratio, matrix size of 128×128, and a parallel hole collimator. In images of similar size to the naked eye, when the matrix size was the same, both SNR and CNR were high in the pinhole collimator. Therefore, when performing a thyroid scintigraphy test, if appropriate conditions are set according to the situation of each hospital and a parallel hole collimator is applied, it can be a good option in terms of equipment utilization and work efficiency.

Study of Factors Controlling Exposure Dose and Image Quality of C-arm in Operation Room according to Detector Size of It (Mainly L-Spine AP Study) (수술 중 C-Arm Neutral AP 검사 시 조절인자에 따른 피폭선량 및 화질비교(L-Spine AP검사를 기준으로))

  • CHOI, Sung-Hyun;JO, Hwang-Woo;Dong, Kyung-Rae;Chung, Woon-Kwan;Choi, Eun-Jin;Song, Ha-jin
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.85-90
    • /
    • 2015
  • Purpose: Time of operation has been reduced and accuracy of operation has been improved since C-arm, which offer real-time image of patient, was introduced in operation room. However, because of the contamination of patient, C-arm could not be used more appropriately. Therefore, this study is to know factors of controlling exposure dose, image quality and the exposed dose of health professional in operation room. Materials and methods: Height of Wilson frame (bed for operation) was fixed at 130 cm. Then, Model 76-2 Phantom, which was set by assembling manual of Fluke Company, was set on the bed. Head/Spine Fluoroscopy AEC mode was set for exposure condition. According to detector size of C-arm, the absorbed dose per min was measured in the 7 steps OFD (cm) from 10 cm to 40 cm (10, 15, 20, 25, 30, 35, 40 cm). In each step of OFD, the absorbed dose per min of same diameter of collimation was measured. Moreover, using Nero MAX Model 8000, exposure dose per min was measured according to 3 step of distance from detector (20 cm, 60 cm, 100 cm). Finally, resolution was measured by CDRH Disc Phantom and magnification of each OFD was measured by aluminum stick bar. Result: According to detector size of C-arm, difference of absorbed dose shows that the dose of 20 cm OFD is 1.750 times higher than the dose of 40 cm OFD. It means that the C-arm, which has smaller size of detector, shows the bigger difference of absorbed dose per min (p<0.05). In the difference of absorbed dose in the same step of OFD (from 20 cm to 40 cm), the absorbed dose of 9 inch detect or C-arm was 1.370 times higher than 12 inch' s (p<0.05). When OFD was set to 20 cm OFD, the absorbed dose of non-collimation case was approximately 0.816 times lower than the absorbed dose of collimation cases (p<0.05). When the distance was 20 cm from detector, exposed does includes first-ray and scatter-ray. When the distance was 60 cm and 100 cm from detector, exposed does includes just scatter-ray. So, there was the 2.200 times difference of absorbed does. Finally, when OFD was increased, spatial resolution was 4 to 5 step was increased. However, low contrast resolution was not relative. Moreover, there was 1.363 times difference of magnification (p<0.05). Conclusion: When C-Arm is used, avoiding contamination of patient is more important factor than reducing exposed dose of health professional in operation room. Just controlling exposure time is just way to reduce the exposed does of workers. However, in the case, non-probability influence could be occurred. Therefore, this study proved that the exposed dose will be reduced if the factors such as using small detector size of C-arm, setting OFD from 20 cm to 25 cm and non-collimating. Moreover, dose management of C-arm in the non-interesting area will be considered additionally.

Surgical Correction and Componential Analysis of Enterolith in Horse (만성적인 산통증상 발현마의 장결석 외과적 치료 및 성분 분석)

  • Yang, Young-Jin;Cho, Young-Jae;Cho, Gil-Jae
    • Journal of Veterinary Clinics
    • /
    • v.31 no.3
    • /
    • pp.250-252
    • /
    • 2014
  • After clinical and laboratory tests of a 12-year-old warmblood horse (castrated male, 540 kg) displaying symptom of pain, a diagnosis of intestinal obstruction due to foreign substances like sand was made and an abdominal section and enterotomy were conducted to confirm and extract the intestinal stone (enterolith) on the right dorsal part of the ascending colon. The extracted intestinal stone was around 2.9 kg and greenish brown rugby ball sized ($22cm{\times}10cm$) stone. Analysis of the element components (EDX) using a scanning electron microscope revealed percentages of C (30.08%), O (39.85%), Mg (3.89%), P (11.15%), and Ca (11.16%) at a magnification of 400. This was the first example of a successful extraction and treatment of intestinal stone in a horse domestically and thereby has its significance.

AN EXPERIMENTAL STUDY ON THE PHYSICAL PROPERTIES OF THE DENTURE BASE RESINS CURED BY MICROWAVE IRRADIATION (마이크로파 중합에 의한 의치상 레진의 물리적 성질에 관한 연구)

  • Kim, Hak Sun;Kim, Kwang Nam;Chang, Ik Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.109-124
    • /
    • 1990
  • The purpose of this study was to investigate the physical propertise and determine whether three were any differences in the amount of porosity of the denture base resins cured by microwave irradiation and conventional water bath heating. The resins used in this study were K-33 resin and Acron MC resin. The properties selected were transverse strength, Knoop hardness, and density. A ten-power eyepiece and scanning electron microscope(Magnification of ${\times}$ 30and ${\times}$150)were used to examine the specimens for porosity. Through analyses of the data from this study, the following conclusions were obtained. 1. Microwave energy can be effectively use dtopolymerize poly(methylmethacrylate) denture base resins. 2. In the transverse strength, K-33 resin cured by microwave irradiation was the first highest, water bath cured K-33 resin the second, microwave cured Acron MC resin the third, water bath cured Acron MC resin the fourth. 3. In the Knoop hardness, K-33 resin cured by microwave irradiation was the first hardest, water bath cured K-33 resin the second, water bath cured Acron MC resin the third, microwave cured Acron MC resin the the fourth. 4. No significant difference was found between the density of resin denture bases polymerized by either method. 5. K-33 resin showed the most porosity for the microwave curing. But there was no significant difference in the Acron MC resin and other curing method.

  • PDF

Natural Dyeing and Dyed Fabrics Properties with Persimmon Juice (감물을 이용한 천염염색과 염직물 특성)

  • Han, Mi-Ran;Lee, Jeong-Sook
    • Fashion & Textile Research Journal
    • /
    • v.12 no.2
    • /
    • pp.224-232
    • /
    • 2010
  • The natural dyeing of fabrics with persimmon juice(astringent persimmon, sweet persimmon, astringent and sweet persimmon mix) was investigated. After dyeing of cotton and silk fabrics with persimmon juice, we evaluated the dyeability of persimmon juice, the observation of fabric surface with high magnification video microscope, physical properties and color fastness with the conditions of repeating times of dyeing and variables of mordants. The results obtained from this study were as follows: The fabrics dyed with astringent persimmon have shown the highest color difference, while the fabrics dyed with sweet persimmon and the fabrics dyed with astringent and sweet persimmon mix have shown similar color differences. With the increase of repeating times of dyeing, the brightness of fabric decreased. However, $a^*$ value increased gradually, so that it became dark brown color. The $a^*$ and $b^*$ values of dyed fabrics with Fe-mordant have dropped significantly, so that they have shown achromatic colors. But the fabrics treated with other mordants have shown yellowish brown colors. On the surface of the fabrics, threads were bonded together by the viscosity of persimmon juice. Regardless of the types of persimmon juice, stiffness was increased after dying, while crease resistance was decreased. The water repellency of silk fabrics were improved than cotton fabrics after dyeing with sweet persimmon juice, but in case of cotton, it hasn't changed. Washing fastness was improved with the EM(Effective Microorganism)-fermented liquid treatment, and rubbing fastness of two fabrics was better in dry condition than in wet condition.

A Classification of Breast Tumor Tissue Images Using SVM (SVM을 이용한 유방 종양 조직 영상의 분류)

  • Hwang, Hae-Gil;Choi, Hyun-Ju;Yoon, Hye-Kyoung;Choi, Heung-Kook
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2005.11a
    • /
    • pp.178-181
    • /
    • 2005
  • Support vector machines is a powerful learning algorithm and attempt to separate belonging to two given sets in N-dimensional real space by a nonlinear surface, often only implicitly dened by a kernel function. We described breast tissue images analyses using texture features from Haar wavelet transformed images to classify breast lesion of ductal organ Benign, DCIS and CA. The approach for creating a classifier is composed of 2 steps: feature extraction and classification. Therefore, in the feature extraction step, we extracted texture features from wavelet transformed images with $10{\times}$ magnification. In the classification step, we created four classifiers from each image of extracted features using SVM(Support Vector Machines). In this study, we conclude that the best classifier in histological sections of breast tissue in the texture features from second-level wavelet transformed images used in Polynomial function.

  • PDF