• Title/Summary/Keyword: $2^{nd}$ Resonance frequency

Search Result 56, Processing Time 0.029 seconds

A Study for improvement of Efficiency of Full-Bridge Converter using Non-Contact Method (무접점 풀브리지컨버터의 효율향상을 위한 연구)

  • Lim Sung-Hun;Joo Yeon-Hong;Lee Seong-Ryong;Han Byoung-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.90-93
    • /
    • 2001
  • This paper suggests the circuit topology to transfer AC power using a detachable transformer The circuit topology for AC output load through the magnetic coupling and its principle of operation are described. It can decrease the size of detachable transformer by employing the high-frequency magnetic coupling. It is shown in this paper that the efficiency of noncontact energy transfer system can be improved by applying both the full bridge converter with PFC function to the 1st side of its and the series resonance to the 2nd side to minimize the effect of the leakage inductance.

  • PDF

RF Measurements of the 2nd fabricated KAERI Dual Energy S-band Linac

  • Song, Gi-Baek;Park, Hyeong-Dal;Li, Yonggui;Cha, Seong-Su;Lee, Byeong-No;Kim, Yu-Jong;Lee, Byeong-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.111.1-111.1
    • /
    • 2013
  • 전자가속기는 대표적인 방사선 발생장치 중의 하나로서, 오랜 세월 동안 연구개발 되어왔으며 의료 및 산업현장에서 활용되어 왔고 그 이용분야도 매우 폭넓다. 전자가속기는 최근 들어 기술이 확산되고 성능이 고도화되면서 그 활용과 함께 전자가속기 개발 및 연구가 많이 진행되고 있다. 이러한 연구개발에 있어 전자가속기의 가속관 제작은 가장 기본이 되는 중요한 부분 중에 하나이다. 가속관제작에 있어서 RF parameter들인 resonance frequency, bandwidth, 10 GHz 범위의 higher order modes와 quality factor는 가속관에서 중요한 특성이다. 본 연구에서는 9, 6 MeV 에너지를 가지는 2856 MHz의 고주파 전자가속기의 가속관 설계, 제작 및 튜닝에 있어서 network analyzer를 이용하여 RF parameter를 측정하여 가속관의 특성을 분석한다.

  • PDF

Investigations on Improvement of Vehicle Design Feature on Idle Shake with Automatic Transmission (자동변속기 장착 차량의 아이들 셰이크 진동 성능 개선 대책에 대한 고찰)

  • Choi, Cheon;Suh, Myung-Won;Kim, Young-Gin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.4
    • /
    • pp.110-120
    • /
    • 2000
  • In order to improve the vibration characteristics of mid sized passenger car automatic transmission at idle experimental and theoretical studies have been carried out. Idle shake in "D" range occurs by various reasons such as characteristics of body bending resonance between subsystems and engine mounts etc. Using full vehicle finite element analyses and modal tests we introduce the way to reduce the idle shake in the early design stage. It shows that the exciting forces are the 2nd order torque and force of engine. A powertrain system modes in "D" range are entirely effected by the additional boundary conditions of drive line. As a result the frequencies of subsystems are arranged to be lined up at the idle frequency range in order to avoid the resonances with subsystems To reduce the idle shake mounts of radiator are tuned to act as a dynamic damper to 1st bending frequency of the body. In addition a hydraulic mount which is optimized by Phase Shift Method is applied to the rear engine mount.e rear engine mount.

  • PDF

Analysis of Dynamic Deformation of 4-Bar Linkage Mechanism(II) (4절 링크 기구의 동적 변형 해석 (II))

  • 조선휘;박종근;주동인
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.910-923
    • /
    • 1992
  • Experimental verification of numerical results is conducted by measuring the dynamic strains of mid-points of the coupler and the lever for the 4-bar linkage mechanism with rigid bearing and flexible bearing, respectively. For the axial strain of lever mid-point, the numerical results including geometric stiffness almost agree with the experimental ones, however, the numerical results excluding geometric stiffness almost agree with the experimental ones for the axial strain of coupler mid-point. It is supposed that these phenomena should be caused by the fact that the motion of the coupler is more complicated than of the lever. The signals of dynamic strains of coupler and lever mid-points, measured by strain gages, are transformed into frequency domain by fast fourier transformer. From this experiment, the lst resonance frequencies of the coupler and the lever are obtained. It is made clear that the former almost agrees with the fundamental and the latter the 2nd mode natural frequency of the mechanism system calculated by numerical analysis.

Dynamic Motions of Model Fish Cage Systems under the Conditions of Waves and Current (파랑 및 흐름중 모형 가두리 시설의 운동 특성)

  • KIM Tae-Ho;KIM Jae-O;RYU Cheong-Ro
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.1
    • /
    • pp.43-50
    • /
    • 2001
  • In order to analyze the dynamic motions of fish cage systems made of a frame and a netting under the conditions of waves and current, the hydraulic model experiment at towing tank and the numerical computation using boundary integral element method based on linear potential theory were carried out on a square and a circular type of fish cage, The computed and measured results for the dynamic motions of model fish cage systems showed that the heave and pitch motions were almost unaffected by the inclusion of nets, while the surge motions were very reduced by drag force acting on them. In addition, irregular wave-induced motions of fish cages included non-negligible 2nd order harmonic components at high frequency nearly twice the wave frequency. The reason why these motions were considered was due to resonance or structural components of frames being overflown and out of water during a wave cycle. It was found that circular type was more desirable structure in the open sea than square one only in the respect of dynamic motions due to waves and current. Further verifications were needed considering hydrodynamic forces, fatigue life, and structure analysis based on long term stochastic waves including frequency and time domain for the purpose of analyzing and designing fish cage systems.

  • PDF

Characteristic of Vibration in Windturbine System (풍력발전시스템의 진동특성)

  • Kim, Jung-Su;Lee, Hyoung-Woo;Park, No-Gill;Kim, Young-Duk;Kim, Soo-Yum;Lee, Dong-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.786-795
    • /
    • 2011
  • This paper described the characteristic of vibration in wind turbine system including gearbox housing, gear drive, blade, generator. Especially, in planetary gear set, planet gears are supported by flexible pin. So, in planet gear, to consider not only torsional movement but also lateral movement. And include housing movement, because wind turbine system is supported by mount. To find out the characteristic of vibration, take the excitation source and study campbell diagram in operating range. Results of campbell diagram, resonances are occurred at 81.2HZ, 104.7Hz by 2nd tooth passing frequency. And resonance are also occurred at 264.5HZ, 377Hz, 424.6Hz by 3th tooth passing frequency. From the result, take vibration reduced measures.

Optical and Mechanical Characteristics of NF System and NF Gap Control (근접장 광학계의 광학적 및 기계적 특성 분석과 근접장 간격제어)

  • Oh, Hyeong-Ryeol;Lee, Jun-Hee;Gweon, Dae-Gab;Kim, Soo-Kyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1528-1532
    • /
    • 2000
  • The conventional optics and near field optics are compared numerically in the view points of the spot size and propagation characteristics. The decaying characteristics of near field light require the optics to access the object within several tens of nanometers. Therefore the gap control is one of the main issues in the near field optics area. In this paper the gap control is done by using the shear force of the NF(Near Field) probe and the characteristics are examined. The probe is modeled as a 2'nd order mass-spring-damper system driven by a harmonic force. The primary cause of the decrease in vibration amplitude is due to the damping force - shear force - between the surface and the probe. Using the model, damping constant and resonance frequency of the probe is calculated as a function of probe-sample distance. Detecting the amplitude and phase shift of the NF probe attached to the high Q-factor piezoelectric tuning fork, we can control the position of the NF probe about 0 to 50nm above the sample. The feedback signal to regulate the probe-sample distance can be used independently for surface topography imaging. 3-D view of the shear force image of a testing sample with the period of $1{\mu}m$ will be shown.

  • PDF

Design of Swing Arm Type's for Small Sized ODD (초소형 광디스크 드라이브를 위한 스윙암 타입 엑추에이터 설계)

  • Oh, Je-Seung;Park, Se-June;Lee, Dong-Ju;Jung, Ho-Seop;Park, No-Cheol;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.70-74
    • /
    • 2004
  • There are many researches being in process to develop the information storage devices applying to the portable devices recently. Based on this need, the information storage devices have to be satisfied with the fast access time, the robustness of the system, high data transfer rate and lower media price. The total size of the drive must design to adapt the portable devices such as CF II card or PC II card size. This paper proposes the swing arm type actuator to insert the designed actuator in the drive of the CF II size. Hereafter the research will be going on to be suitable to the physical standard and design the focus magnetic circuit newly. The swing arm type actuator including this circuit is designed to have the dynamic characteristic satisfying the mechanical specification as well as the BD 1x. Finally, the adaptability to the portable devices was demonstrated by the finite element analysis and optimization of structural part.

  • PDF

THE EFFECT OF SURFACE TREATMENT OF THE CERVICAL AREA OF IMPLANT ON BONE REGENERATION IN MINI-PIG (미니돼지에서 발치 후 즉시 임플란트 매식시 치경부 표면처리가 골재생에 미치는 효과)

  • Cho, Jin-Yong;Kim, Young-Jun;Yu, Min-Gi;Kook, Min-Suk;Oh, Hee-Kyun;Park, Hong-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.285-292
    • /
    • 2008
  • Purpose: The present study was performed to evaluate the effect of surface treatment of the cervical area of implant on bone regeneration in fresh extraction socket following implant installation. Materials and methods: The four minipigs, 18 months old and 30 kg weighted, were used. Four premolars of the left side of both the mandible and maxilla were extracted. ${\phi}$3.3 mm and 11.5 mm long US II plus implants (Osstem Implant co., Korea) with resorbable blasting media (RBM) treated surface and US II implants (Osstem Implant co., Korea) with machined surface at the top and RBM surface at lower portion were installed in the socket. Stability of the implant was measured with $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden). After 2 months of healing, the procedures and measurement of implant stability were repeated in the right side by same method of left side. At four months after first experiment, the animals were sacrificed after measurement of stability of all implants, and biopsies were obtained. Results: Well healed soft tissue and no mobility of the implants were observed in both groups. Histologically satisfactory osseointegration of implants was observed with RBM surface, and no foreign body reaction as well as inflammatory infiltration around implant were found. Furthermore, substantial bone formation and high degree of osseointegration were exhibited at the marginal defects around the cervical area of US II plus implants. However, healing of US II implants was characterized by the incomplete bone substitution and the presence of the connective tissue zone between the implant and newly formed bone. The distance between the implant platform (P) and the most coronal level of bone-to-implant contact (B) after 2 months of healing was $2.66{\pm}0.11$ mm at US II implants group and $1.80{\pm}0.13$mm at US II plus implant group. The P-B distance after 4 months of healing was $2.29{\pm}0.13$mm at US II implants group and $1.25{\pm}0.10$mm at US II plus implants group. The difference between both groups regarding the length of P-B distance was statistically significant(p<0.05). Concerning the resonance frequency analysis (RFA) value, the stability of US II plus implants group showed relatively higher RFA value than US II implants group. Conclusion: The current results suggest that implants with rough surface at the cervical area have an advantage in process of bone regeneration on defect around implant placed in a fresh extraction socket.

Effect of Densities on Dielectric Properties of $Ba[Mg_{1/3}(Nb_{0.2}Ta_{0.8})_{2/3}]O_3$Ceramics ($Ba[Mg_{1/3}(Nb_{0.2}Ta_{0.8})_{2/3}]O_3$ 세라믹스의 밀도가 유전특성에 미치는 영향)

  • 김재윤;김부근;김강언;정수태;조상희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.6
    • /
    • pp.485-492
    • /
    • 2000
  • The sintering characteristics and the effects of density on dielectric properties in 0.2Ba(Mg$_{1}$3(Nb$_{2}$3/)O$_3$-0.8Ba(Mg$_{1}$3//Ta$_{2}$3/)O$_3$ceramics were investigated. The samples were made by the powder mixing techniques with the two step calcining conditions. When the 1st and the 2nd calcining temperatures were 120$0^{\circ}C$ and the sintering temperature was 155$0^{\circ}C$the density of samples showed the highest value (7.45 g/cm$^3$, 98.5% of theoretical density) among them. The dielectric constant of samples was nearly independent of density but the tan $\delta$ and the temperature coefficient of dielectric constant decreased linearly with increasing of the density. The quality factor(Q$\times$f), the temperature coefficient of resonance frequency and the dielectric constant of Ba[Mg$_{1}$3(Nb$_{0.2}$/Ta$_{0.8}$)sub 2/3/]O$_3$ceramic were 79,548 GHz, +1.5 ppm/$^{\circ}C$ and 26 in the microwave range, respectively.ely.

  • PDF