• Title/Summary/Keyword: ${GC}^2$

Search Result 3,303, Processing Time 0.028 seconds

Gas Chromatographic Analysis of TDI, MDI and HDI Using 2-Chlorobenzyl Alcohol and 2,4-Dichlorobenzyl Alcohol Derivatives (2-클로로벤질 알코올 및 2,4-디클로로벤질 알코올 유도체를 이용한 TDI, MDI 및 HDI의 가스크로마토그래피 분석)

  • Yun, Ju-Song;Park, Jun-Ho;Lee, Kang-Myoung;Choi, Hong-Soon;Cho, Young-Bong;Koh, Sang-Baek;Cha, Bong-Suk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.3
    • /
    • pp.222-232
    • /
    • 2006
  • Objectives: The objective of this study was to propose the total isocyanate analytical method which involves derivation of 2,4-toluene diisocyanate(2,4-TDI), 2,6-toluene diisocyanate(2,6-TDI), 4,4'-methylenediphenyl diisocyanate(4,4'-MDI) and 1,6-hexamethylene diisocyanate(1,6-HDI) using 2-chlorobenzyl alcohol(2-CBA) or 2,4-dichlorobenzyl alcohol(2,4-DCBA), and analyzing of hydrolysate of the synthesized urethane with the gas chromatography(GC)/flame ionization detector(FID), GC/pulsed discharge ionization detector-electron capture detector(PD-ECD) and GC/mass selective detector(MSD). Methods: Urethanes were synthesized by reacting 2,4-TDI, 2,6-TDI, 4,4'-MDI and 1,6-HDI to 2-CBA or 2,4-DCBA. Urethanes was verified by TLC, HPLC/UVD and GC/MSD. For field application, the most suitable condition that 2-CBA coated in glass fiber filter removed completely and urethanes were not removed was searched. 2-CBA generated from hydrolysis of urethanes according to hydrolysis conditions. Diisocyanates were collected on field air and analyzed. Results: Urethanes which were white and solid phase synthesized by reacting 2,4-TDI, 2,6-TDI, 4,4'-MDI, 1,6-HDI and 2-CBA or 2,4-DCBA. And urethanes were verified by TLC, HPLC/UVD and GC/MSD. The most suitable conditions to remove 2-CBA coated in glass fiber filter were $87^{\circ}C$ and 20 mmHg and urethanes were not removed under same condition. Hydrolysis yields of urethanes were 99 % to 111 %. 2-CBA, the hydrolysate of urethanes was analyzed by GC/FID, GC/PD-ECD and GC/MSD. Conclusions: Simultaneous analysis of 2,4-TDI, 2,6-TDI, 4,4'-MDI and 1,6-HDI deriving with 2-CBA and 2,4-DCBA, along with a total isocyanate analysis, was feasible with GC/FID, GC/PD-ECD and GC/MSD. This result will be a guide of further study on total isocyanate analysis.

Multiresidual Pesticide Analysis in Crude Drug -Gas Chromatographic Analysis of 16 Controlled Pesticides- (생약 중 잔류농약의 분석(I) - GC에 의한 16종의 잔류 규제 농약의 분석 -)

  • 박만기;박정일;윤혜란;이은정;이수연;노일협
    • YAKHAK HOEJI
    • /
    • v.37 no.1
    • /
    • pp.54-65
    • /
    • 1993
  • A method for the determination of 16 residual pesticides in crude deugs was examined. Crude drug was extracted with acetonitrile/water solution and the extract was partitioned between hexane/CH$_{2}$Cl$_{2}$ and NaCl saturated water. The organic layer was passed through cleanup column and subjected to the GC/ECD or GC/NPD analysis. Essential oil components in crude drug interfere with the analysis, and sulfuric acid treatment was adapted to overcome this interference.

  • PDF

Volatile Components in Persimmon Vinegars by Solid-Phase Microextraction (Solid-Phase Microextraction(SPME)을 이용한 감식초의 휘발성 성분 분석)

  • Seo, Ji-Hyung;Park, Nan-Young;Jeong, Yong-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.153-156
    • /
    • 2001
  • Traditional static headspace and headspace solid-phase microextraction(SPME) techniques were compared for their effectiveness in the extraction of volatile flavor compounds from the headspace of persimmon vinegar. The adsorption condition of SPME fiber for equilibrated headspace vapor was selected as $80^{\circ}C$ and 20 min. Total FID response for volatiles of persimmon vinegar was exactly higher such as total peak area $18.18{\times}10^6$ in SPMEGC technique than total peak area $1.35{\times}10^6$ in static headspace-GC. The major volatiles in persimmon vinegar were acetic acid, ethyl acetate, 3-hydroxy-2-butanone, ethanol, phenethyl alcohol. From static headspace-GC technique, 3 acids, 3 aldehydes, 5 alcohols, 9 esters and 1 ketone were identified. From SPME-GC technique, total 34 compounds including 6 acids, 7 aldehydes, 6 alcohols, 9 esters, 2 hydrocarbones, 1 ketone, 3 others were detected. Also the ratio for benzaldehyde, phenethylacetate and phenethylalcohol were higher in SPME-GC.

  • PDF

Determination of N-nitrosamines in Water by Gas Chromatography Coupled with Electron Impact Ionization Tandem Mass Spectrometry (EI-GC/MS/MS를 이용한 니트로사민류의 수질분석)

  • Lee, Ki-Chang;Park, Jae-Hyung;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.11
    • /
    • pp.764-770
    • /
    • 2014
  • This study assessed analysis of N-nitrosamines by separation, identification, and quantification using a gas chromatography (GC) mass spectrometer (MS) with electron impact (EI) mode. Samples were pretreated by a automated solid phase extraction (SPE) and a nitrogen concentration technique to detect low concentration ranges. The analysis results by EI-GC/MS (SIM) and EI-GC/MS/MS (MRM) on standard samples with no pretreatment exhibited similar results. On the other hand, the analysis of pretreated samples at low concentrations (i.e. ng/L levels) were not reliable with a EI-GC/MS due to the interferences from impurity peaks. The method detection limits of eight (8) N-nitrosamines by EI-GC/MS/MS analysis ranged from 0.76 to 2.09 ng/L, and the limits of quantification ranged from 2.41 to 6.65 ng/L. The precision and accuracy of the method were evaluated using spiked samples at concentrations of 10, 20 and 100 ng/L. The precision were 1.2~13.6%, and the accuracy were 80.4~121.8%. The $R^2$ of the calibration curves were greater than 0.999. The recovery rates for various environmental samples were evaluated with a surrogate material (NDPA-$d_{14}$) and ranged 86.2~122.3%. Thus, this method can be used to determine low (ng/L) levels of N-nitrosamines in water samples.

Flavor Components of Poncirus trifoliata (탱자(Poncirus trifoliata)의 향기성분 분석에 관한 연구)

  • Oh, Chang-Hwan;Kim, Jung-Han;Kim, Kyoung-Rae;Ahn, Hey-Joon
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.749-754
    • /
    • 1989
  • The essential oil was prepared by a gas co-distillation method from flavedo of Poncirus trifoliata and was analyzed by GC/ retention index (RI) and GC/MS. The essential oil prepared by a gas co-distillation gave a whole fragrance of Poncirus trifoliata. The identification of the flavor components was performed by multi-dimensional analysis using GC/RI and GC/MS. GC/RI and GC/MS were complementary to each other. In applying GC/RI for identification, it was more effective when two columns of different polarities were used. Thirty volatile flavor constituents were identified in Poncirus trifoliata. Limonene, myrcene, ${\beta}-caryophyllene,\;trans-{\beta}-ocimene$, ${\beta}-pinene$, 3-thujene and 7-geranyloxycoumarin were the major constituents and cis-3-hexenyl acetate, n-hexyl acetate, 2-methyl acetophenone, elixene and elemicine had not been reported earlier as citrus components.

  • PDF

GC/MS and its applications for the analysis of cosmetic produtcts (GC/MS와 화장품 분석의 응용)

  • 노경원
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.19 no.1
    • /
    • pp.1-19
    • /
    • 1993
  • Gas chromatography serves to separate the mixtures into its components, and mass spectrometer is used to analyzing of unknown compounds. But there are many problems the identification of horn compounds using by GC only. As this reason GC/MS a very powerful analyzing technique. Mass spectrometer consists of 1) inlet stem 2) ion source 3) Bass filter 4) detectors and 5) data system. There are two analyzing modes in the GC/MS, those are scan and SIM(selected ion mom toping) modes. Scan mode is used when analyzing unknown compounds and SIM mode al lows the mass spectrometer to detect specific compound with very high sensitivity. As GC/MS applications for the analysis of cosmetic products, volatile compounds in lotion, earn foundation and hair color, and carbon distribution of fatty acids in soap were performed. Also as a new sample pre-treatment technique, head space sampler/GC/MS introduced in order to analyze the volatile compounds in a toothpaste.

  • PDF

Quality Over Volume: Modeling Centralization of Gastric Cancer Resections in Italy

  • Lorenzon, Laura;Biondi, Alberto;Agnes, Annamaria;Scrima, Ottavio;Persiani, Roberto;D'Ugo, Domenico
    • Journal of Gastric Cancer
    • /
    • v.22 no.1
    • /
    • pp.35-46
    • /
    • 2022
  • Background: The correlation between hospital volume and postoperative outcomes has led to the centralization of complex procedures in several countries. However, the results reported in relation to gastric cancer (GC) are contradictory. This study aimed to analyze GC surgical volumes and 30-day postoperative mortality in Italy and to provide a simulation for modeling centralization of GC resections based on district case volumes. Methods: A national registry was used to identify all GC resections, record mortality rates, and track the national in-border GC resection health travel. Hospitals were grouped according to caseload. Centralization of all GC procedures performed within the same district was modeled. The outcome measures were a minimal volume of 25 GC resections/year and the 30-day postoperative mortality. Results: In 2018, 5,873 GC resections were performed in 498 Italian hospitals (mean resections per hospital per year: 11.8); the postoperative mortality rate (5.51%) was tracked from 2016-2018. GC resection health travel ranged from 2% to 50.5%, with a significant (P<0.001) difference between northern and central/southern Italy. The mean mortality rate was 7.7% in hospitals performing one to 3 GC resections per year, compared with 4.7% in those with >17 GC resections/year (P≤0.01). Most Italian districts achieved 25 procedures/year after centralization; however, 66.3% of GC cases in southern Italy vs. 42.2% in central and 52.7% in the northern regions (P<0.001) required reallocation. Conclusion: Postoperative mortality after GC resection correlated with hospital volume. Despite health travel, most Italian districts can reach a high-volume threshold, but discrepancies in mortality rates are alarming.Trial RegistrationResearch Registry Identifierresearchregistry6869

Analytical method of the polychlorinated biphenyls in soil using GC/ECD and GC/MS (GC/ECD 및 GC/MS을 이용한 토양 중 PCBs 분석방법 고찰)

  • Kim, Tae-Seung;Shin, Sun-Kyoung;Yoon, Jeong-Ki;Kim, Jong-Ha;Kim, Hyoung Seop;Lee, Jeong Ah
    • Analytical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.91-108
    • /
    • 2007
  • This study was investigated both the Korean official soil test method and the international various methods for PCBs in soil sample. The analytical guideline of PCBs in contaminated soil were proposed based on the official soil test methods by discussing the extraction, column cleanup, instrumental conditions, quantification methods of peak matching and individual isomers. The total 28 soil samples were selected by consideration of PCBs-contamination, land use etc., and then analyzed using gas chromatography/electron capture detection (GC/ECD) and gas chromatography/mass spectrometry(GC/MS). In this study, the PCBs were not detected as peak matching method using GC/ECD, but PCBs detected $0.002{\sim}0.487{\mu}g/kg$ using GC/MS in background concentrations.

Gingival crevicular fluid CSF-1 and IL-34 levels in patients with stage III grade C periodontitis and uncontrolled type 2 diabetes mellitus

  • Ahu Dikilitas;Fatih Karaaslan;Sehrazat Evirgen;Abdullah Seckin Ertugrul
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.6
    • /
    • pp.455-465
    • /
    • 2022
  • Purpose: Periodontal diseases are inflammatory conditions that alter the host's response to microbial pathogens. Type 2 diabetes mellitus (T2DM) is a complex disease that affects the incidence and severity of periodontal diseases. This study investigated the gingival crevicular fluid (GCF) levels of colony-stimulating factor-1 (CSF-1) and interleukin-34 (IL-34) in patients with stage III grade C periodontitis (SIII-GC-P) and stage III grade C periodontitis with uncontrolled type 2 diabetes (SIII-GC-PD). Methods: In total, 72 individuals, including 24 periodontally healthy (PH), 24 SIII-GC-P, and 24 SIII-GC-PD patients, were recruited for this study. Periodontitis patients (stage III) had interdental attachment loss (AL) of 5 mm or more, probing depth (PD) of 6 mm or more, radiographic bone loss advancing to the middle or apical part of the root, and tooth loss (<5) due to periodontal disease. Radiographic bone loss in the teeth was also evaluated; grade C periodontitis was defined as a ratio of the percentage of root bone loss to age greater than 1.0. The plaque index (PI), gingival index (GI), presence of bleeding on probing (BOP), PD, and clinical AL were used for clinical periodontal assessments. GCF samples were obtained and analyzed using an enzyme-linked immunosorbent assay. Results: All clinical parameters-PD, AL, GI, BOP, and PI-were significantly higher in the SIII-GC-PD group than in the PH and SIII-GC-P groups for both the full mouth and each sampling site (P<0.05). The total IL-34 and CSF-1 levels were significantly higher in the SIII-GC-PD group than in the PH and SIII-GC-P groups (P<0.05), and there were significant differences between the periodontitis groups (P<0.05). Conclusions: These findings suggest that IL-34 and CSF-1 expression increases in patients with SIII-GC-PD. CSF-1 was associated with the inflammatory status of periodontal tissues and T2DM, while IL-34 was associated only with T2DM.

Acute Cyclosporin A-Treatment Impairs the Cytosolic Guanylate Cyclase-Mediated Vasodilatation in Rat Thoracic Aorta

  • Kook, Hyun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.2 no.4
    • /
    • pp.471-477
    • /
    • 1998
  • Cyclosporin A (CsA), a widely used immunosuppressant, is well known to cause nephrotoxicity and hypertension as major side effects. The present study was aimed at investigating the effects of CsA-pretreatment on the activities of cytosolic guanylate cyclase (cGC) in relation to the alteration of relaxant responses in the rat thoracic aorta. CsA $(10\;{\mu}M)-preincubation$ for 90 min significantly attenuated the vasodilatation induced by sodium nitroprusside (SNP), a cytosolic guanylate cyclase activator, shifting the dose-response curve to the right. The increase in cGMP contents induced by SNP was markedly attenuated by CsA. SNP ($1\;{\mu}M{\sim}\;mM$) increased the cGC activity dose-dependently, and the increase was completely abolished by CsA. CsA attenuated the SNP-induced cGC activation dose-dependently. The abolishing effect of CsA-pretreatment on the SNP-induced cGC activation was not affected by washing the preparation, suggesting that the inhibition is irreversible. When CsA was added simultaneously with SNP, cGC activation was not attenuated. 1-(5-isoquinolinylsulfonyl)-2-methyl piperazine (H-7), a protein kinase C (PKC) inhibitor, decreased SNP-induced cGC activation and blocked the CsA-attenuation of cGC activation. These results suggest that CsA directly inhibits cGC participating in the CsA-induced impairment of vasodilatation, and that PKC is involved in the inhibitory action of CsA on cGC.

  • PDF