• 제목/요약/키워드: ${CO_2}^*$ background

검색결과 837건 처리시간 0.026초

고종시 감껍질의 추출조건에 따른 항산화 활성 (Changes in the Antioxidant Potential of Persimmon Peel Extracts Prepared by Different Extraction Methods)

  • 정명진;진순우;화성용;방희옥;한동문;전지영;화세경
    • 한국약용작물학회지
    • /
    • 제27권3호
    • /
    • pp.186-193
    • /
    • 2019
  • Background: Astringent persimmon (Diospyros kaki Thunb. cv. Kojongsi) peels are by-products of dried persimmons. This study aimed to evaluate the antioxidant activities of Kojongsi persimmon peel (KPP) extracts prepared by 15 different extraction methods: 5 heating durations (0.5 - 2.5 h) at 3 heating temperatures (50, 70, and $90^{\circ}C$). Methods and Results: An increase in heating temperature increased the antioxidant effect of KPP extracts. Those prepared by heating at 1 h had the highest total phenol content, regardless of the heating temperature. In addition, the 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging activity and cell-protective effects against $H_2O_2-induced$ oxidative stress were dependent on the total phenol contents of the extract. However, the KPP-induced increased in catalase expression was dependent on heating temperature and duration. Conclusions: These results suggest that extraction by heating at $90^{\circ}C$ for 1 h may enhance KPP's antioxidant effects, which mainly involve non-enzymatic antioxidant systems.

유방암 환자에서 전신 뼈 검사 후 감시림프절 위치 파악 검사의 유용성 (Usefulness of Breast Lymphoscintigraphy after Whole Body Bone Scan)

  • 장동근;반영각;정석;박훈희;강천구;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.133-137
    • /
    • 2010
  • 유방암은 다른 장기에 비하여 뼈 전이와 임파절 전이가 잘 일어나는 질환으로 알려져 있으며, 유방암 수술 전, 후로 핵의학 검사인 전신 뼈 검사와 감시림프절 검사가 많이 시행되고 있다. 감시림프절 위치 파악 검사는 감시림프절에 정확 위치를 파악을 위해 시행되며, 유방암 수술 시 감시림프절을 파악 하는데 중요한 정보를 제공해 주게 된다. 본 연구에서는 감시림프절 위치 파악 검사 시 해부학적인 위치정보를 좀 더 명확하게 하기 위해 감시림프절 위치 파악 검사 전날 전신 뼈 검사를 시행하여 기존에 Flood 선원을 이용한 방법과 비교 평가하여 영상의 유용성에대해 알아보고자 하였다. 2009년 1월부터 12월까지 본원에서 전신 뼈 검사와 감시 림프절 검사를 2일에 걸쳐 시행한 환자 22명(평균나이 $52{\pm}7.2$세)을 대상으로 하였고, 대조군으로는 $^{57}Co$ flood phantom을 이용하여 감시림프절에 위치를 파악한 환자 22명(평균나이 $57{\pm}6.5$세)을 대상으로 하였다. 정량적인 분석 방법으로 전신 뼈 검사 후에 감시림프절 검사를 시행한 영상에 감시림프절과 배후방사능에 관심영역을 그려 상대적 비율을 측정하였으며, 육안적인 분석 방법으로 전신 뼈 검사 후 감시림프절 검사를 진행한 영상과 $^{57}Co$ flood phantom을 이용한 영상을 핵의학과 전문의와 5년 이상의 실무경험을 가진 방사선사가 각각 5점 척도로 하여, Blind test하였다. 정량적인 분석 결과 감시림프절에 대해 배후방사능이 미치는 영향은 전면상에서 최대 14.2:1, 평균 8:1(SD${\pm}$3.48), 측면상에서 최대 14.7:1, 평균 8.5:1(SD${\pm}$3.42)값으로 감시림프절에 대해 배후방사능에 차이가 크게 나타났고, 전면상과 측면상에서도 큰 차이가 없었다. 육안적인 분석 결과 $^{57}Co$ flood phantom 영상과 뼈가 포함된 영상을 비교한 결과 $^{57}Co$ flood phantom 영상 $3.86{\pm}0.35$점, 뼈 영상이 $4.09{\pm}0.42$점으로 $^{57}Co$ flood phantom 영상 보다 높은 점수를 나타내었다. 감시림프절 위치 파악 검사에 경우 검사 전날 전신 뼈 검사를 진행하였을 때에 뼈의 배후방사능과 감시 림프절에 비율차이가 평균 8:1 이상으로 림프절에 위치를 파악 하는데 문제가 없었다. 또한 전신 뼈 영상을 체표윤곽도로 이용하게 되면, 다른 선원을 이용하지 않고도 감시림프절에 위치정보를 나타낼 수 있어서 술자와 환자의 불필요한 피폭을 방지하며, 영상의 질적 향상을 기대할 수 있을 것으로 사료 된다.

  • PDF

Research on sustainable development of international trade in Shandong Province under the background of the fourth industrial revolution

  • ZHANG, Fan
    • 한국인공지능학회지
    • /
    • 제8권2호
    • /
    • pp.17-22
    • /
    • 2020
  • Purpose: After entering the 21st century, a new industrial revolution, i.e. industrial revolution 4.0, which is characterized by intelligence, automation and networking, has opened the curtain of the "industry 4.0" era. In recent years, "low-carbon economy" has been a development goal that has been paid close attention to and adhered to at home and abroad. As a major economic province, Shandong Province has not only brought about rapid economic growth, but also caused rapid environmental deterioration due to its high energy consumption, high dependence and high environmental pollution. In this environment, low-carbon economy has become an inevitable trend in the development of foreign trade in Shandong Province. Based on the current situation of foreign trade in Shandong Province and various existing problems, this paper explores the relationship between low-carbon economy and foreign trade in Shandong Province under this strategic background. Research design, data and methodology: By selecting the data from 2008 to 2017, using the carbon emission coefficient method to measure the CO2 emissions in the past decade, analyzing the impact of ecological factors on trade, selecting the most representative GDP and total imports for regression analysis, it is proved that they have a real impact on CO2 emissions. The total GDP is positively correlated with carbon emissions, while the total import is negatively correlated with carbon emissions. Results:This paper discusses the impact of low-carbon economy on foreign trade of Shandong Province from the perspective of foreign trade. Especially in today's "low-carbon economy" background. Conclusions:it is helpful for relevant departments to formulate relevant policies and promote the sustainable development of foreign trade in Shandong Province.

한반도 배경대기 중 온실기체의 농도 변동 특성 분석 (Analysis of Variation Characteristics of Greenhouse Gases in the Background Atmosphere Measured at Gosan, Jeju)

  • 주옥정;차준석;이동원;김영미;이정영;박일수
    • 한국대기환경학회지
    • /
    • 제23권4호
    • /
    • pp.487-497
    • /
    • 2007
  • Increase of the greenhouse gases emissions during last century has led remarkable changes in our environment and climate system. Continuous monitoring of atmospheric constituents over the world is positively necessary to understand these changes around us. The concentrations of greenhouse gases ($CO_2,\;CH_4,\;N_2O,\;CFCs$) have been continuously measured at Global Climate Change Monitoring station in Gosan, Jeju since January, 2002. In this study, the variation characteristics of greenhouse gases as well as their annual, seasonal and diurnal trend using the data from January, 2002 to December, 2005 were analyzed. The raw data which was used in the analysis were validated with the methods recommended by WDCGG (World Data Center for Greenhouse Gases). The concentration of $CO_2$ was increasing continuously by 2.1 ppm/year, while $CH_4$ did not show any increasing or decreasing trend clearly for 4 years. The concentration of $N_2O$ was slightly increasing and CFCs were decreasing except CFC-12 which has longer lifetime compared with other CFCs. The variations of the greenhouse gases at Gosan were shown to be consistent with the global trend. But the concentration level of $CO_2$ in Korea was more or less higher than abroad.

Surgical Outcomes of Pneumatic Compression Using Carbon Dioxide Gas in Thoracoscopic Diaphragmatic Plication

  • Ahn, Hyo Yeong;Kim, Yeong Dae;I, Hoseok;Cho, Jeong Su;Lee, Jonggeun;Son, Joohyung
    • Journal of Chest Surgery
    • /
    • 제49권6호
    • /
    • pp.456-460
    • /
    • 2016
  • Background: Surgical correction needs to be considered when diaphragm eventration leads to impaired ventilation and respiratory muscle fatigue. Plication to sufficiently tense the diaphragm by VATS is not as easy to achieve as plication by open surgery. We used pneumatic compression with carbon dioxide ($CO_2$) gas in thoracoscopic diaphragmatic plication and evaluated feasibility and efficacy. Methods: Eleven patients underwent thoracoscopic diaphragmatic plication between January 2008 and December 2013 in Pusan National University Hospital. Medical records were retrospectively reviewed, and compared between the group using $CO_2$ gas and group without using $CO_2$ gas, for operative time, plication technique, duration of hospital stay, postoperative chest tube drainage, pulmonary spirometry, dyspnea score pre- and postoperation, and postoperative recurrence. Results: The improvement of forced expiratory volume at 1 second in the group using $CO_2$ gas and the group not using $CO_2$ gas was $22.46{\pm}11.27$ and $21.08{\pm}5.39$ (p=0.84). The improvement of forced vital capacity 3 months after surgery was $16.74{\pm}10.18$ (with $CO_2$) and $15.6{\pm}0.89$ (without $CO_2$) (p=0.03). During follow-up ($17{\pm}17$ months), there was no dehiscence in plication site and relapse. No complications or hospital mortalities occurred. Conclusion: Thoracoscopic plication under single lung ventilation using $CO_2$ insufflation could be an effective, safe option to flatten the diaphragm.

Reopening of dental clinics during SARS-CoV-2 pandemic: an evidence-based review of literature for clinical interventions

  • Keyhan, Seied Omid;Fallahi, Hamid Reza;Motamedi, Amin;Khoshkam, Vahid;Mehryar, Paymon;Moghaddas, Omid;Cheshmi, Behzad;Firoozi, Parsa;Yousefi, Parisa;Houshmand, Behzad
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.25.1-25.13
    • /
    • 2020
  • Background: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) causes serious acute respiratory diseases including pneumonia and bronchitis with approximately 2.3% fatality occurrence. Main body: This study argues the main concepts that need to be considered for the gradual reopening of dental offices include treatment planning approaches, fundamental elements needed to prevent transmission of SARS-CoV-2 virus in dental healthcare settings, personal protection equipment (PPE) for dental health care providers, environmental measures, adjunctive measures, and rapid point of care tests in dental offices. Conclusion: This article seeks to provide an overview of existing scientific evidence to suggest a guideline for reopening dental offices.

광중합형 복합레진과 콤포머의 두께와 배경색에 따른 색변화 (THE COLOR CHANGE OF VISIBLE LIGHT-CURED COMPOSITE RESINS AND COMPOMERS ACCORDING TO THE THICKNESS AND BACKGROUND COLOR)

  • 임주환;한진순;이수종;임미경
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.71-77
    • /
    • 2000
  • The color of an esthetic restorative material is controlled primarily by thickness of the material and background color. Although the effects of the two factors on the color coordinates of esthetic dental materials have been reported, the mechanism has not been clarified well enough to explain the effects quantitatively. The purpose of this study was to evaluate the effect of thickness and background color on the color of tooth colored restorative materials quantitatively. One hundred sixty samples were fabricated from two commercial light-cured composite resins and two commercial compomers. The color characteristics and changes in the color coordinates were measured by a tristimulus colorimeter (Model TC-6FX, Tokyo Denshoku Co. Japan) using the CIELAB system. The results were as follows: 1. As thickness increased from 1.0 to 4.0mm, values of $L^*$ $a^*$ $b^*$ changed irregulary for white and dentin color background, but showed no obvious difference in color for black background. 2. The colors of composite resins and compomers were significantly influenced by background color. 3. The color difference was recognized even the same shade name in four representative kinds of composite resins and compomers. 4. As thickness changed, values of color difference for same products and same background color showed constancy, but showed difference for different background color.

  • PDF

6가 크롬 처리를 위한 알루미늄 산화물을 함유한 재생 분말 폐기물의 적용 (Application of Reused Powdered Waste Containing Aluminum Oxide on the Treatment of Cr(VI))

  • 임재우;김태환;강형식;김도선;김한선;조석희;양재규;장윤영
    • 대한환경공학회지
    • /
    • 제31권3호
    • /
    • pp.179-185
    • /
    • 2009
  • 본 연구에서는 알루미늄 산화물을 함유한 재생 분말 폐기물에 의한 Cr(VI)의 제거특성을 조사하였다. 가공하지 않은 폐기물의 유기물을 제거하기 위해 $550^{\circ}C$에서 소성하여 재생 분말 폐기물(RPW)을 준비하였다. 수용액 상에서 Cr(VI)의 흡착 경향에 관한 연구를 위해 회분식 반응장치를 이용하여 pH 변화, 흡착 속도, 등온 흡착 실험을 4가지 다른 이온세기 화학종($NO_3\;^-,\;CO_3\;^{2-},\;SO_4\;^{2-},\;PO_4\;^{3-}$)의 존재 하에서 수행하였다. $SO_4\;^{2-}$$PO_4\;^{3-}$가 존재할 때는 전체 pH 범위에서 크롬의 흡착이 크게 감소하였다. 반면 $NO_3\;^-$$CO_3\;^{2-}$에 의한 흡착 방해의 영향은 $SO_4\;^{2-}$$PO_4\;^{3-}$에 의한 것보다 상대적으로 낮았다. $NO_3\;^-$$CO_3\;^{2-}$의 존재 하에 Cr(VI) 흡착은 pH 4.5에서 최대로 나타났다. 이온세기 화학종의 농도가 증가함에 따라 Cr(VI)의 흡착은 감소하였다. 이러한 결과를 토대로 할때 RPW와 Cr(VI) 사이의 흡착은 외부배위권 착물을 통하여 발생되는 것으로 사료된다. RPW에 의한 Cr(VI)의 흡착은 2차 반응으로 잘 표현되었다. Langmuir 등온흡착식을 이용하여 pH 3에서 RPW에 의한 Cr(VI)의 최대 흡착량을 구한결과 $NO_3\;^-,\;CO_3\;^{2-},\;SO_4\;^{2-},\;PO_4\;^{3-}$가 이온세기 화학종으로 있을 때 각각 11.1, 10, 3.33, 5 mg/g으로 얻어졌다.

한국의 태안반도에서 관측된 CO의 지역적 배경농도에 관한 연구 (On the Regional Background Level of CO Observed at Tae-ahn Peninsula in Korea During 1990-1992)

  • 정용승;이근준
    • 한국대기환경학회지
    • /
    • 제9권3호
    • /
    • pp.200-206
    • /
    • 1993
  • Since November 1990, observations of carbon monoxide(CO) levels have been carried out at Tat-ahn Peninsula(TAP) in Korea. Analysis on atmospheric data, obtained in the period from November 1990 to February 1992, is carried out and the results are included in this study. It is observed that variations of monthly average level on CO are in the range of 141.61-516.06ppb(amplitude 374.45 ppb). An average level in 1991 is 308.18 ppb. CO observed at TAP has a larger seasonal variation. One of reasons appears that CO of TAP is strongly influenced by local sources and westerly airflows. When this gas of TAP is compared with data observed at Korea National University of Education(KNU) and in Seoul, we learn that CO values of KNU are higher(in average 2.15 times) than those of TAP; CO value observed in Seoul are 7 times higher than those of TAP. We interprete that air samples taken both at KNU and in Seoul are influenced strongly by local sources than those at TAP. According to analysis of trajectories and air flows, the CO value is higher with NW airflows than the value with SW airflows.

  • PDF

The Use of Locally Applied Vibration to Minimize Pain during Fractional CO2 Laser Therapy in Living Liver-Donor Scar Management

  • Song, Sinyoung;Choi, Dong Hoon;Oh, Tae Suk
    • Archives of Plastic Surgery
    • /
    • 제43권6호
    • /
    • pp.570-574
    • /
    • 2016
  • Background Fractional $CO_2$ laser is an effective treatment for scars, but most patients complain about sharp burning pain, even after the application of lidocaine ointment. This study analyzed the impact of a vibrating device to nonpharmacologically reduce the acute pain of laser treatment, in accordance with the gate control theory of pain management. Methods This is a prospective study performed from May 2013 through March 2014. Fifty-three patients (mean age, 26.7 years; range, 16-44 years) who had donated livers for liver transplantation were treated with a fractional $CO_2$ laser (10,600 nm; model $eCO_2$, Lutronic Corp) for their abdomen scars. Laser treatment was applied 4 months after surgery. A commercially available, locally applied vibrating device (model UM-30M, Unix Electronics Co. Ltd.) was used, in an on-and-off pattern, together with the $CO_2$ laser. A visual analogue scale (VAS; 0, no pain; 10, most severe pain) of pain sensation was assessed and statistically analyzed using a paired t-test. Results The average VAS score for pain with the vibrating device was 4.60 and the average VAS score without the vibrating device was 6.11. The average difference between scores was 1.51 (P=0.001). Conclusions A locally applied vibrating device was demonstrated to be effective in reducing pain when treating with a fractional $CO_2$ laser. Vibration treatment could be helpful when treating scars with fractional $CO_2$ laser in pain-sensitive patients, particularly children.