• 제목/요약/키워드: ${CO}_{2}$ Laser

검색결과 988건 처리시간 0.031초

$CO_2$ 레이저 원격 용접시스템을 이용한 800Mpa급 고장력강의 용입특성 (The characteristic of penetration on the 800Mpa class high-tensile steel using remote welding system by $CO_2$ laser)

  • 송문종;이영주;송영채;정성문;정병훈;이문용
    • 한국레이저가공학회:학술대회논문집
    • /
    • 한국레이저가공학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.17-20
    • /
    • 2006
  • In the remote welding system using $CO_2$ laser, laser beam is rapidly deflected by moving mirrors of scanner system and has focusable distance over 1000mm from workpiece. From such arrangement, various advantages and disadvantages arise. Remote welding is a highly efficient laser process. As the mirrors of the scanner system allow positioning speeds exceeding 700m/s, it becomes possible to reduce the welding cycle time. On the other hand, as there no the provision of shielding gas which is normally required for beam powers exceeding 3kW, may become difficult task. Therefore, In this study, the influence of the various penetration of back bead by the different laser welding speed on the weld seam formation without shielding gas was investigated.

  • PDF

Co-base 분말을 적용한 SCM440과 GC250의 레이저 클래딩 가공성 평가 (Feasibility Study of Laser Cladding for Co-based Coating on SCM440 and GC250)

  • 최병주;이문구;홍민성;안병민;정도현;이광재;이충근;전용호
    • 한국생산제조학회지
    • /
    • 제26권3호
    • /
    • pp.337-343
    • /
    • 2017
  • The laser cladding process on structural steel (SCM440) and gray cast iron (GC250) substrates with Co-based powder (Stellite 12) was studied. A diode laser (2 kW) was used as a heat source, and the powder was supplied by a disc rotary powder feeder. The relationship between the laser cladding process and the cross-sectional analysis of coating was examined based on coating shape and microstructure. Additionally, the microhardness was measured to confirm the mechanical property improvements. As a result, proper laser cladding conditions were selected through this study and verified by cross-sectional analysis. In addition, the evaluation process for laser cladding feasibility was conducted on the selected materials.

Laser Drilling of High-Density Through Glass Vias (TGVs) for 2.5D and 3D Packaging

  • Delmdahl, Ralph;Paetzel, Rainer
    • 마이크로전자및패키징학회지
    • /
    • 제21권2호
    • /
    • pp.53-57
    • /
    • 2014
  • Thin glass (< 100 microns) is a promising material from which advanced interposers for high density electrical interconnects for 2.5D chip packaging can be produced. But thin glass is extremely brittle, so mechanical micromachining to create through glass vias (TGVs) is particularly challenging. In this article we show how laser processing using deep UV excimer lasers at a wavelength of 193 nm provides a viable solution capable of drilling dense patterns of TGVs with high hole counts. Based on mask illumination, this method supports parallel drilling of up over 1,000 through vias in 30 to $100{\mu}m$ thin glass sheets. (We also briefly discuss that ultrafast lasers are an excellent alternative for laser drilling of TGVs at lower pattern densities.) We present data showing that this process can deliver the requisite hole quality and can readily achieve future-proof TGV diameters as small $10{\mu}m$ together with a corresponding reduction in pitch size.

Transoral Laser Excision of a Pyriform Sinus Cyst

  • Lee, Sang Joon;Chung, Phil-Sang;Chung, Sang Yong;Woo, Seung Hoon
    • Medical Lasers
    • /
    • 제8권2호
    • /
    • pp.84-86
    • /
    • 2019
  • Pyriform sinus cyst is a rare disease. This disease can be found by chance or appear as lymph nodes with cancer, infections, shortness of breath, or airway compromise, and can be an unusual cause of dysphonia. This paper presents a case of a pyriform sinus cyst in the pharyngeal wall of the left pyriform sinus, which presented as neck discomfort in a 63-year-old female. The plan was to remove this cyst with a transoral CO2 laser because a CO2 laser is a useful tool for removing cysts without bleeding and consuming time. The excision was performed successfully. Transoral laser pyriform sinus cyst excision is a simple, safe, and effective method for the treatment of pyriform sinus cysts. This procedure is likely to be used as a selective treatment when managing this condition.

비글견의 피부절개를 위한 $CO_2$ 레이저의 출력 결정 (Determination of $CO_2$ Laser Output Power for the Skin Incision in Beagle Dogs)

  • 신범준;정현웅;손화영;정주영;박성준;김명철;정성목
    • 한국임상수의학회지
    • /
    • 제25권5호
    • /
    • pp.379-384
    • /
    • 2008
  • The objective of this study was to determine output power for skin incision in 0.3 mm spot diameter $CO_2$ laser by measuring (1) the wound depth, (2) initial dermal tissue damage, (3) degree of wound healing at different power (4W, 5W and 6W) in beagle dogs. Three healthy 2-year-old beagle dogs were used. Four 2 cm straight skin incisions were made with 0.3 mm spot diameter $CO_2$ laser on the each dog's both side of dorsal midline in three beagle dogs. The skin incisions were performed for $10{\sim}15$ seconds for same dosage. And then each wound was closed with surgical stapler. At 0, 3, 7 and 14 days after initial wounding, each wound was taken for histological observation. On macroscopic and microscopic observation, initial incisional wound did not show difference in three group. And also re-epithelialization, dermal tissue damage and inflammatory response did not show significant difference among groups. This study reveals that 4W, 5W and 6W may be suitable output power in 0.3 mm spot diameter $CO_2$ laser for the skin incision in beagle dogs.

AISI 316 스테인레스강의 $CO_2$ 레이저 용접 (High Power $CO_2$ Laser Beam Welding of AISI 316 Stainless Steel)

  • 김재도
    • Journal of Welding and Joining
    • /
    • 제9권2호
    • /
    • pp.29-36
    • /
    • 1991
  • 6mm 두께의 AISI 316 스테인레스강의 레이저 용접 특성에 대해서 고찰하였다. 3kW C $O_{2}$레이저를 사용하였으며, 레이저 빔은 TE $M_{00}$모우드였고 연속파이었다. 용입 깊이, 비드 폭, 고온 크랙, 가공등의 특성을 고찰하는데 있어서, 레이저 출력은 1kW에서 2.5kW까지, 용접 속도는 5.1m/min까지 적용하였다. 3차원 열전달 방정식에 의한 용입 깊이와 비드 폭에 대한 예측치와 실험 결과를 비교하였는데, 서로 잘 일치하였다.다.

  • PDF

CO2레이저 조사가 치아경조직에 미치는 영향에 관한 EPMA분석 및 주사전자현미경적 연구 (A STUDY OF CO2 LASER IRRADIATED DENTAL HARD TISSUES USING ELECTRON PROBE MICROANALYZER AND SCANNING ELECTRON MICROSCOPE)

  • 장계봉;이정석;이찬영;이승종
    • Restorative Dentistry and Endodontics
    • /
    • 제12권1호
    • /
    • pp.51-64
    • /
    • 1986
  • The purpose of this study is to obtain the data of prestep in cavity preparation by observing changed conditions of laser irradiated dental hard tissues. The forty five extracted caries free human molars were divided into three groups and each group into five subgroups. A $CO_2$ laser irradiation was performed each subgroup of group I for one second with output power of 5 W, 10 Wand 20 W. On group II, laser irradiation was done ten times for 0.1 second duration using same power ratings as group I. On group III, laser irradiation was done 0.1 second, 0.2 second and 0.4 second with output power of 50 W. We investigated mineral contents and crater wall of obtained specimens, i.e., laser irradiated teeth, using computer controlled electron probe microanalyzer and scanning electron microscope. The following results were obtained: 1. Both calcium and phosphorus contents in laser irradiated enamel crater wall were increased, and magnesium content was decreased, but these trends were not statistically significant. 2. In laser irradiated dentin, change of mineral content was more significant. 3. In laser irradiated enamel and dentin, there were no significant differences on mineral content change due to irradiation condition and energy density. 4. In scanning electron microscopic study, enamel rods of the crater wall were fused and clefts were observed in parallel with the direction of enamel rod for all groups. 5. In laser irradiated dentin, irregular fusion and clefts were observed. In irradiated teeth with high power and short duration, the locally formed narrow crater wall was observed.

  • PDF

이산화탄소 레이저를 이용한 바나듐 이산화물 박막 전자 소자에서의 전류 스위칭에 관한 연구 (Study on Current Switching in Electronic Devices Based on Vanadium Dioxide Thin Films Using CO2 Laser)

  • 김지훈;이용욱
    • 조명전기설비학회논문지
    • /
    • 제30권1호
    • /
    • pp.1-7
    • /
    • 2016
  • With a collimated $CO_2$ laser beam, the bidirectional current switching was realized in a two-terminal electronic device based on a highly resistive vanadium dioxide($VO_2$) thin film. A $VO_2$ thin film was grown on a $Al_2O_3$ substrate by a pulsed laser deposition method. For the fabrication of a two-terminal electronic device, the $VO_2$ thin film was etched by an ion beam-assisted milling method, and the $VO_2$ device, of which $VO_2$ patch width and electrode separation were 50 and $100{\mu}m$, respectively, was fabricated through a photolithographic method. A bias voltage range for stable bidirectional current switching was found by using the current-voltage property of the device measured in a current-controlled mode. The transient responses of bidirectionally switched currents were analyzed when the laser was modulated at a variety of pulse widths and repetition rates. A switching contrast was measured as ~3333, and rising and falling times were measured as ~39 and ~21ms, respectively.

이종금속간의 결합방법에 따른 결합강도에 관한 비교 연구 (Comparative analysis on mechanical properties of gold and Co-Cr dental alloys due to joining methods)

  • 박성규;최부병;권긍록
    • 구강회복응용과학지
    • /
    • 제19권2호
    • /
    • pp.75-86
    • /
    • 2003
  • The purpose of this study was to evaluate their mechanical properties after laser-welding or soldering of precious and non-precious dental alloys. For this study, 30 Co-Cr alloy specimens, 15 gold alloy specimens, 15 palladium alloy specimens were casted and seperated on the middle area. 15 sperated Co-Cr specimens and 15 seperated gold alloy specimens were laser welded (GW Group). 15 sperated Co-Cr specimens and 15 sperated gold alloy specimens were soldered by coventional soldering method (GS Group). 15 sperated Co-Cr specimens and 15 seperated palladium alloy specimens were laser welded (PW Group). 15 sperated Co-Cr specimens and 15 sperated palladium alloy specimens were soldered by coventional soldering method (PS Group). Tensile strength, 0.2% yield strength, % elongation were recorded in nine specimens of each group. Bending strength were record in six specimens of each group. These data for four groups were subjected to a two-way analysis of variance(ANOVA). The fracture locations, fractured surfaces were examined by SEM(scanning electron microscope). The results were as following: 1) In the same alloy combination, the tensile strength and 0.2% yield strength and of the laser welded group with same metal combination were significantly less than soldered groups(p<0.05). 2) In the combination of Co-Cr/Palladium, the bending strength of laser welded group were significantly less than that of soldered groups(p<0.05). In the combination of Co-Cr/Gold, the bending strength of laser welded group were significantly higher than that of soldered groups(p<0.05). 3) In the same method of joint, the tensile strength and 0.2% yield strength and bending strength of the Co-Cr/gold were significantly higher than Co-Cr/palladium(p<0.05). 4) There was no significantly statistical difference between each group in the % elongation(p>0.05). 5) The fracture of the laser welded specimens occured in the welding area and a large void was observed at the center of the fracture surface. 6) The fracture of the soldered specimens occured also inthe soldered area and many porpsities were showed at the fracture sites.

산부인과용 펄스형 $CO_2$레이저의 펄스모듈 특성과 동작파형 변화에 따른 안정된 시스템의 설계 및 구현 (Design and embodiment of stable system by change of action waveform by pulsemodule special quality of pulse style$CO_2$ laser for obstetrics and gynecology)

  • 김휘영
    • 한국컴퓨터산업학회논문지
    • /
    • 제8권2호
    • /
    • pp.97-102
    • /
    • 2007
  • [ $CO_2$ ] 레이저는 최소한 조직손상으로 이러한 효과를 얻는데 최적이라고 보며 0.1mm의 최소한의 세포조직 깊이에서 일어나는 효과의 근본적인 장점은 생체조직이나 내장기관에 안정적이다. 열에 의한 조직손상은 조직의 종류나 에너지밀도, 증발시간의 장단에 관계될 수가 있다 증발시간을 짧게 하면 주위세포의 열적손상은 $200\sim400um$이내에 일어나므로 레이저 빔은 비초점 영역에서 주위세포조직을 손상함이 없이 증발에 의한 제거나, 아주 얇은 층의 포를 깨끗하게 증발시킬 수 가 있다. $CO_2$레이저는 산부인과 응용에 표준이 되는 레이저시스템으로 외음부 상피내종양, 자궁암, 상피 종양에도 적용이 가능하다. 슈퍼펄스 출력은 거의 동일하나 펄스지속시간이 짧으면 레이저의 열적인 효과가 감소가 되므로 무엇보다도 산부인과용 펄스형 $CO_2$ 레이저의 펄스모듈 특성은 모드안정화가 매우 중요함으로, 본 연구에서는 짧은 펄스지속시간과 고출력밀도 되도록, DC-DC Converter에서 고주파로 스위칭 할수록 출력 DC의 ripple은 고주파화 되는데, 고주파화된 전류 리플은 출력 필터용 콘덴서의 량을 크게 줄일 수 있다. 출력의 ripple을 근사적으로 Zero까지 실현이 가능한 인덕터를 적용하여 특성실험을 통하여 실현하였다.

  • PDF