• Title/Summary/Keyword: ${99m}^Tc$

Search Result 1,347, Processing Time 0.036 seconds

Alterations of Regional Cerebral Blood Flow in Major Depressive Disorder (주 우울증 환자의 국소 뇌혈류 변화 연구)

  • Lee, Won-Hyoung;Chung, Yong-An;Seo, Ye-Young;Yoo, Ik-Dong;Na, Sae-Jung;Jung, Hyun-Suk;Kim, Ki-Jun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.107-111
    • /
    • 2009
  • Purpose: The authors analyzed how the regional cerebral blood flow(rCBF) findings of patients with major depression differ from the normal control, and our results were compared to previous reports. Materials and Methods: Twelve patients fulfilling DSM-IV criteria for major depression who were off all psychotropic medications for > 4weeks(male: 7, female: 5, age range: $19{\sim}52$ years, average age: $29.3{\pm}9.9$ years) and 14 normal volunteers(male: 8, female: 6, age range: $19{\sim}53$ years, average age: $31.4{\pm}9.2$ years) were recruited. Images of brain perfusion SPECT were obtained using Tc-99m ECD and patterns of the rCBF were compared between patients with major depression and the healthy control subjects. Results: The patients with major depression showed increase of the r-CBF in right lingual gyrus, right fusiform gyrus, left lingual gyrus, left precuneus, and left superior temporal gyrus, and showed decrease of r-CBF in right pons, left medial frontal gyrus, cingulate gyrus of left limbic lobe, cingulate gyrus of right frontal lobe, and cingulate gyrus of right limbic lobe compared to the normal control. Conclusion: The Tc-99m ECD brain perfusion SPECT findings in our study did not differ from the previously reported regional cerebral blood flow pattern of patients with major depression. Especially, decreased rCBF pattern typical to major depression patients in the right pons, left medial frontal gyrus, and cingulate regions was clearly demonstrated.

Comparison of Attenuation Correction Methods for Brain SPECT Ima (Brain SPECT 영상의 Attenuation Correction 방법들에 대한 비교)

  • Jo, Jin U;Kim, Chang Ho;Na, Soo Kyung;Lee, Gui Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.120-125
    • /
    • 2012
  • Purpose : The purpose of this study was to compare count between Chang's method and CT-based attenuation correction (AC-CT) among the attenuation correction (AC) methods for non-attenuation correction (AC-non) images of Brain SPECT (Single Photon Emission Computed Tomography). Materials and Methods : We injected $^{99m}Tc$ 37Mbq in a Hoffman 3D phantom filled with distilled water in the phantom study, and injected intravenously $^{99m}Tc$-HMPAO 740Mbq in a normal volunteer in the patient study, and then obtained Brain SPECT images with Symbia T6 of Siemens and conducted quantitative brain analysis. Transverse images to which each method was applied were rebuilt at the same position, and 6 regions of interest (ROI) were drawn on each of Slice No. 10, 20 and 30 and then the counts of AC-non, AC-CT and Chang's method were compared. Results : The mean counts of AC-non, AC-CT and Chang's method were $4606.8{\pm}511.3$, $16794.6{\pm}2429.4$, and $8752.6{\pm}896.5$, respectively, in the phantom study and $5460.8{\pm}519.6$, $15320{\pm}1171.6$ and $12795{\pm}1422.1$, respectively, in the patient study. In the phantom study, the ratio of AC-CT to AC-non was 3.70 and the ratio of Chang's method to AC-non was 1.92, and in the patient study, they were 2.85 and 2.38, respectively. Conclusion : From this study, we found that AC-CT makes higher AC than Chang's method. In addition, when Chang's method was used, AC in the patient study was higher than that in the phantom study. These results need to be considered also in other examinations.

  • PDF

The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery (Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2017
  • Purpose Recently, with the spread of SPECT/CT, various image correction methods can be applied quickly and accurately, which enabled us to expect quantitative accuracy as well as image quality improvement. Among them, the Collimator Detector Response(CDR) recovery is a correction method aiming at resolution recovery by compensating the blurring effect generated from the distance between the detector and the object. The purpose of this study is to find out quantitative change depending on the change in detection distance in SPECT/CT images with CDR recovery applied. Materials and Methods In order to find out the error of acquisition count depending on the change of detection distance, we set the detection distance according to the obit type as X, Y axis radius 30cm for circular, X, Y axis radius 21cm, 10cm for non-circular and non-circular auto(=auto body contouring, ABC_spacing limit 1cm) and applied reconstruction methods by dividing them into Astonish(3D-OSEM with CDR recovery) and OSEM(w/o CDR recovery) to find out the difference in activity recovery depending on the use of CDR recovery. At this time, attenuation correction, scatter correction, and decay correction were applied to all images. For the quantitative evaluation, calibration scan(cylindrical phantom, $^{99m}TcO_4$ 123.3 MBq, water 9293 ml) was obtained for the purpose of calculating the calibration factor(CF). For the phantom scan, a 50 cc syringe was filled with 31 ml of water and a phantom image was obtained by setting $^{99m}TcO_4$ 123.3 MBq. We set the VOI(volume of interest) in the entire volume of the syringe in the phantom image to measure total counts for each condition and obtained the error of the measured value against true value set by setting CF to check the quantitative accuracy according to the correction. Results The calculated CF was 154.28 (Bq/ml/cps/ml) and the measured values against true values in each conditional image were analyzed to be circular 87.5%, non-circular 90.1%, ABC 91.3% and circular 93.6%, non-circular 93.6%, ABC 93.9% in OSEM and Astonish, respectively. The closer the detection distance, the higher the accuracy of OSEM, and Astonish showed almost similar values regardless of distance. The error was the largest in the OSEM circular(-13.5%) and the smallest in the Astonish ABC(-6.1%). Conclusion SPECT/CT images showed that when the distance compensation is made through the application of CDR recovery, the detection distance shows almost the same quantitative accuracy as the proximity detection even under the distant condition, and accurate correction is possible without being affected by the change in detection distance.

  • PDF

Clinical Characteristics and Prognostic Factors of Vesicoureteral Reflux (방광요관역류의 임상적 특징 및 예후인자)

  • Kim, Wun-Kon;Ha, Tae-Sun
    • Childhood Kidney Diseases
    • /
    • v.18 no.1
    • /
    • pp.29-35
    • /
    • 2014
  • Introduction: Persistent vesicoureteral reflux (VUR), a major cause of urinary tract infection (UTI) in children, can result in serious renal complications, such as reflux nephropathy and chronic renal failure. We evaluated the clinical characteristics and prognostic factors of VUR. Methods: From December 1993 to May 2011, we examined 117 children with vesicoureteral reflux who were admitted to the Department of Pediatrics and Urology, Chungbuk National University hospital for a UTI. The patients were managed medically or surgically. Results: Male patients had a slightly higher prevalence of VUR than female patients (55%). The degrees of the 161 refluxing ureters, as classified by the International Reflux Study Committee, were as follows: grade I, 15 ureters; grade II, 32 ureters; grade III, 54 ureters; grade IV, 26 ureters; grade V, 34 ureters. One hundred and sixty-one renal units (115 cases) underwent a 99m TC-DMSA renal scan, and 62% showed abnormal findings. The incidence of renal cortical defects showed a direct correlation with the severity of VUR. Ninety-four refluxing ureters were followed up medically, and 66 ureters (67%) either disappeared or improved. However, 9 refluxing ureters persisted. The spontaneous resolution rate of VUR seemed to be higher in younger patients with lower grades of reflux, and without renal cortical defects. Sixty-seven refluxing ureters (41%) were treated surgically, 62 refluxing ureters (92%) disappeared, and 5 refluxing ureters (8%) persisted. Conclusion: The incidence of renal cortical defects in patients with UTIs was 62% (in a 99m TC-DMSA renal scan), and showed a direct correlation with the severity of VUR. The spontaneous resolution rate seemed to be lower in the patients with higher grades of VUR, older age (over 4 years old) and diffuse renal cortical defects.

Prognostic Implication of Normal Myocardial Perfusion Scintigraphy in Patients with Chest Pain (정상 심근관류신티그라피 소견을 보인 흉통환자의 예후)

  • Song, Ho-Cheon;Min, Jung-Jun;Kim, Ji-Yeul;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.67-72
    • /
    • 1997
  • Myocardial scintigraphy is a widely used noninvasive procedure with high sensitivity for the detection of patients with suspected coronary artery disease. The purpose of this study was to determine the prognostic value of a normal myocardial scintigraphy in 292 patients (150 males, 142 females, mean age $53{\pm}12$ years) with chest pain who were followed from 7 to 58 (mean 25) months. Myocardial SPECT was performed with Tc-99m MIBI in 173 patients, with Tc-99m tetrofosmin in 74 patients and with T1-201 in 45 patients. During the follow-up period, there were 2 cardiac deaths and 2 nonfatal myocardial infarctions resulting in cardiac event rate of 1.37% (0.66% Per Year). The cardiac event rate was not different in patients with angiographically normal coronary arteries (1/30, 3.3%) and in those who had significant coronary artery disease (2/27, 7.4%) (p=0.60). In conclusion, patients with chest pain and normal myocardial scintigraphy have a low cardiac event rate, and there was no significant difference of. cardiac event rates between patients with normal and abnormal coronary angiograms.

  • PDF

Bone Marrow Scintigraphy with Antigranulocyte Antibody in Multiple Myeloma: Comparison with Simple Radiography and Bone Scintigraphy (항과립구 항체 골수스캔을 이용한 다발성 골수종 병변의 평가: 단순골X-선점사 및 골스캔과의 비교)

  • Kim, Dong-Hwan;Lee, Jae-Tae;Baek, Jin-Ho;Jung, Jin-Tae;Hyun, Dong-Woo;Chun, Kyung-Ah;Lee, Young-Hak;Sohn, Sang-Kyun;Song, Hong-Seok;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.354-364
    • /
    • 1998
  • Purpose: Simple X-ray study and bone scan have limitations for early diagnosis of bone or bone marrow lesions in multiple myeloma. The purpose of this study was to evaluate the diagnostic usefulness of bone marrow immunoscintigraphy using anti-granulocyte monoclonal antibody for the evaluation of bone involvement in multiple myeloma. Materials and Methods: In 22 patients (Male: 15, Female: 7) with multiple myeloma, we performed whole-body immunoscintigraphy using $^{99m}Tc$-labelled antigranulocyte antibody (BW 250/183, Scintimum $Granulozyt^{(R)}$ CIS, France) and compared the findings with those of simple bone radiography and $^{99m}Tc$-MDP bone scan. Abnormal findings in bone marrow scintigraphy were, considered to be present in case of expansion of peripheral bone marrow or focal photon defect in axial bones. Results: Marrow expansion was noted in 15 of 22 patients (68%). Focal photon defects were found in 18 patients (82%). While one (33%) of 3 patients with Stage II disease showed focal defects in bone marrow scan, abnormal focal defects were observed in 17 of 19 (90%) patients with Stage III. Among 124 focal abnormal sites which were observed in bone marrow scan, bone scan or simple bone radiography, bone marrow scan detected 92 sites (74%), whereas 82 sites (66%) were observed in simple bone radiography(58 sites, 47%) or bone scan(40 sites, 32%). Fifty-one (41%) out of 124 bone lesions were detected by bone marrow scan only, and located mostly in thoracolumbar spine. Conclusion: Bone marrow scan using $^{99m}Tc$-labelled antigranulocyte antibody seems to be a more sensitive procedure for the detection of pathologic bone lesions than simple bone X-ray or bone scan in patients with multiple myeloma.

  • PDF

Gender Difference of Accuracy in Detecting Coronary Artery Disease by Myocardial Perfusion SPECT (디피리다몰 심근관류 SPECT를 이용한 관동맥질환 진단에 있어 남녀간의 진단율 비교)

  • Min, Jung-Jun;Bom, Hee-Seung;Song, Ho-Cheon;Jeong, Hwan-Jeong;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.129-136
    • /
    • 1998
  • Purpose: Myocardial SPECT is an effective test for detecting coronary artery disease in the general population. But the diagnostic accuracy between sexes is not defined. The purpose of this study is to compare the diagnostic accuracy between males and females. Materials and Methods: One hundred and seventy seven male and 98 female patients who underwent myocardial SPECT within 1 month of coronary angiography were studied. Myocardial SPECTS were considered abnormal if fixed or reversible perfusion defects were detected. Stenosis severity of ${\geq}$ 50% luminal diameter reduction of any artery defined coronary artery disease (CAD). Results: Overall sensitivity for detection of CAD was 98% in men and 97% in women (p=not significant). However, specificities, accuracies, and positive predictive values (PPV) in men and women were 49% vs 31% (p<0.05), 81% vs 57% (p<0.01), 78% vs 48% (p<0.01), respectively. Diagnostic accuracies for detection of right coronary artery disease were not different in both sexes, however, accuracies for detection of left anterior descending artery disease and left circumflex artery disease were significantly lower in female (p<0.05). Conclusion: A significant difference of diagnostic accuracy between sexes, especially in LAD and LCx disease, was noted. Artifacts from breast attenuation might be a cause for the lower diagnostic accuracy in female.

  • PDF

Improved Activity Estimation using Combined Scatter and Attenuation Correction in SPECT (단일광자방출단층촬영 영상에서 산란 및 감쇠 보정에 위한 절대방사능 측정)

  • Lee, Jeong-Rim;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Seong-Wun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.382-390
    • /
    • 1998
  • Purpose: The purpose of this study was to evaluate the accuracy of radioactivity quantitation in Tc-99m SPECT by using combined scatter and attenuation correction. Materials and Methods: A cylindrical phantom which simulates tumors (T) and normal tissue (B) was filled with varying activity ratios of Tc-99m. We acquired emission scans of the phantom using a three-headed SPECT system (Trionix, Inc.) with two energy windows (photopeak window: $126{\sim}154keV$ and scatter window: $101{\sim}123keV$). We performed the scatter correction with dual-energy window subtraction method (k=0.4) and Chang attenuation correction. Three sets of SPECT images were reconstructed using combined scatter and attenuation correction (SC+AC), attenuation correction (AC) and without any correction (NONE). We compared T/B ratio, image contrast [(T-B)/(T+B)] and absolute radioactivity with true values. Results: SC+AC images had the highest mean values of T/B ratios. Image contrast was 0.92 in SC+AC, which was close to the true value of 1, and higher than AC (0.77) or NONE (0.80). Errors of true activity by SPECT images ranged from 1 to 11% for SC+AC, $22{\sim}47%$ for AC, and $2{\sim}16%$ for NONE in a phantom which was located 2.4cm from the phantom surface. In a phantom located 10.0cm from the surface, SC+AC underestimated by 24%, NONE 40%. However, AC overestimated by 10%. Conclusion: We conclude that accurate SPECT activity quantitation of Tc-99m distribution can be achieved by dual window scatter correction combind with attenuation correction.

  • PDF

Improvement of Diagnostic Accuracy by Standardization in Diuretic Renal Scan (소아 이뇨 신장스캔에서 검사 표준화에 의한 폐쇄 진단 성능 향상)

  • Hyun, In-Young;Lee, Dong-Soo;Lee, Kyung-Han;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Kim, Kwang-Myung;Choi, Hwang;Choi, Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.497-503
    • /
    • 1995
  • We evaluated diagnostic accuracy of diuretic renal scan with standardization in 45 childrens(107 hydronephrotic kidneys) with 91 diuretic assessments. Sensitivity was 100%, specificity was 78%, and accuracy was 84% in 49 hydronephrotic kidneys with standardization. Diuretic renal scan without standardization, sensitivity was 100%, specificity was 38%, and accuracy was 57 % in 58 hydronephrotic kidneys. The false-positive results were observed in 25 cases without standardization, and in 8 cases with standardization. In diuretic renal scans without standardization, the causes of false-positive results were 10 early injection of lasix before mixing of radioactivity in pelvocalyceal system, 4 full bladder, 2 markedly dilated pelvocalyceal systems postpyeloplsty, 6 extrarenal pelvis, and 3 immature kidneys of neonates. In diuretic renal scans with standardization the causes of false-positive results were 2 markedly dilated systems postpyeloplsty, 2 extrarenal pelvis, 1 immature kidney of neonate, and 2 severe venal dysfunction, 1 vesicoureteral reflux. In diuretic renal scan without standardization the false-positive results by inadequate study were common, but false-positive results by inadequate study were not found after standardization. The false-positive results by dilated pelvocalyceal systems postpyeloplsty, extrarenal pelvis, and immature kidneys of neonates were not dissolved after standardization. In conclusion, diagnostic accuracy of diuretic renal scan with standardization was useful in children with renal outflow tract obstruction by improving specificity significantly.

  • PDF

Influence of Ischemic Lesions on $^{99m}Tc$-HMPAO SPECT Findings in the Diagnosis of Alzheimer's Disease ($^{99m}Tc$-HMPAO SPECT를 이용한 알쯔하이머병의 진단에서 허혈성 뇌병변이 미치는 영향)

  • Lee, Kyung-Han;Lee, Myung-Chul;Lee, Dong-Soo;Kwon, June-Soo;Kim, Jong-Ho;Chung, June-Key;Woo, Jong-In;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.282-292
    • /
    • 1994
  • Brain perfusion SPECT shows typical regional perfusion abnormalities in Alzheimer's disease(AD) and is useful for its diagnosis. However, there is also arguement that these patterns show significant overlap with other causes, and the accuracy for SPECT in differentiating AD has shown conflicting results. We postulate that the variation in re-ported results are partly due to a difference in patient or control selection with special reference to the mixture of ischemic cerebral disease in the studied population. To deter-mine the effect of ischemic lesions and the nature of control subjects on SPECT studies for AD, we performed $^{99m}Tc$-HMPAO single photon emission computed tomography (SPECT) in 11 probable AD patients with a low (<4) Hachinski ischemic score and 12 non-demented age matched controls. Magnetic resonance imaging(MRI) disclosed ischemic cerebral lesions in 27% (3/11) of the PAD group and 25% (3/12) of the control group. Regional perfusion indices were quantitated from the SPECT images as follows and the distribution of perfusion indices from both groups were compared. This was repeated with controls after excluding those with significant ischemic lesions by MRI : regional perfusion index = average regional count/average cerebellar count All PAD patients showed perfusion abnormality in SPECT. However, 53% (10/12) of controls also showed perfusion at-normalities, and no pattern could reliably differentiate the two groups. After excluding controls with significant cerebral ischemia, the difference in temporal and parietal perfusion index was increased. A decreased tempore-parietal and any parietal or temporal per-fusion index had a sensitivity of 18% and 36% in detecting AD, respectively. When using a separate group of normal age mathced controls, the indices showed an even more difference in the temporal and parietal lobes and the sensitivity of a decreased tempore-parietal and any parietal or temporal perfusion index had a sensitivity of 36% and 55% in detecting AD, respectively. Thus, the type of control with special reference to the pres-once of ischemic cerebral lesions contribute significantly to the accuracy of perfusion SPECT in diagnosing AD. This nay have particular importance in the diagnosis of AD in populations where the prevalance of cerebrovascular disease is high.

  • PDF