• 제목/요약/키워드: ${238}^U$

검색결과 210건 처리시간 0.026초

DETERMINATION OF THE TRANSURANIC ELEMENTS INVENTORY IN HIGH BURNUP PWR SPENT FUEL SAMPLES BY ALPHA SPECTROMETRY-II

  • Joe, Kih-Soo;Song, Byung-Chul;Kim, Young-Bok;Jeon, Young-Shin;Han, Sun-Ho;Jung, Euo-Chang;Song, Kyu-Seok
    • Nuclear Engineering and Technology
    • /
    • 제41권1호
    • /
    • pp.99-106
    • /
    • 2009
  • The contents of transuranic elements ($^{237}Np$, $^{238}Pu$, $^{239}Pu$, $^{240}Pu$, $^{241}Am$, $^{244}Cm$, and $^{242}Cm$) in high-burnup spent fuel samples ($35.6{\sim}53.9\;GWd/MtU$) were determined by alpha spectrometry. Anion exchange chromatography and diethylhexyl phosphoric acid extraction chromatography were applied for the separation of these elements from the uranium matrix. The measured values of the nuclides were compared with ORIGEN-2 calculations. For plutonium, the measurements were higher than the calculations by about $2.6{\sim}32.7%$ on average according to each isotope, and those for americium and curium were also higher by about $35.9{\sim}63.1%$. However, for $^{237}Np$, the measurements were lower by about 52% on average for the samples.

3D Simulator를 이용한 아이솔레이터 최적화 설계 및 개발에 관한 연구 (A Study on the Development and Optimization Design of Isolator by Using the 3D Simulator)

  • 정승우;최우성
    • 한국전자파학회논문지
    • /
    • 제17권3호
    • /
    • pp.229-238
    • /
    • 2006
  • 본 논문에서는 3-D 시뮬레이터를 이용하여 아이솔레이터의 공진기를 설계하고 변화에 대한 factor를 이용하여 단순화된 시뮬레이션 방식을 제안하고 그에 따른 제품의 특성 값을 비교하고자 하였다. 3차원 유한요소법(FEM)을 이용한 소프트웨어로 중심 주파수가 1.85 GHz 대역인 스트립라인을 설계하여 변수를 확인하였으며, 최종 최적화된 스트립라인과 상용화되어 있는 페라이트를 이용하여 삽입 손실, 0.2 dB 이하, 반사 손실과 격리도가 25 dB 이상인 아이솔레이터를 개발하였다. 시뮬레이션 결과와 비교하여 90 % 이상 일치하는 것을 확인할 수 있었다.

인터루킨-2의 제제설계를 위한 체내 동태학적 연구 (Pharmacokinetic Preformulation Study of rH IL-2)

  • 서민석;심창구;권종범;나도선;이선복;함경수;한문희
    • 약학회지
    • /
    • 제34권4호
    • /
    • pp.238-243
    • /
    • 1990
  • Pharmacokinetic characteristics of recombinant human interleukin-2 (rH IL-2) wre studied in the rat. First, different doses of rH IL-2 ranging from 6,400 to 1,600,000 U/kg were injected intravenously and the effect of dose size on the pharmacokinetics was examined. There was no dose dependency in the pharmacokinetics of rHIL-2 in the dose range of 6,400-40,000 U/kg. But at the dose of 1,600,000 U/kg, there was a severe hemolysis throughout the experiment and the pharmacokinetic parameters such as Vdss and CLt were significantly increased compared to those obtained from lower doses. It also showed that this drug is hardly distributed to the peripheral tissues and hardly eliminated from the body, since the valume of distribution (Vdss) and total body clearance (CLt) were 45-75 ml/kg and 1-2 ml/min/kg, respectively. The Vdss is close to the actual plasma volume and the CLt is less than glomerular filtration rate (GFR). Therefore it seemed that rH IL-2 is distributed only in the plasma pool and hardly filtered in the kidney due to its very large molecular weight. Second, rH IL-2 was administered to the rat via several routes such as hepatic portal vein (PV), intraperitoneal (IP), peroral (PO) and intranasal (IN) routes. The bioavailabilities (BA) of PV, IP, PO and IN routes were 96.8, 4.9, 0 and 0.1%, respectively. The addition of some nasal absorption enhancers such as taurocholate, taurodeoxycholate, glycocholate and glycodeoxycholate did not increase the BA of intranasaly administered rH IL-2. The result is contrast to the effect of these bile salts on the nasal absorption of ${\alpha}-inteferon$. Considering it together with the pharmacokinetic parameters, very large molecular weight of rH IL-2 seemed again to be the cause to very poor membrane permeability.

  • PDF

암석의 절리면 거칠기 정량화 기법 개발을 통한 절리면 전단강도 특성 분석 (Analysis fo the Rock Joint Strength Characteristics Using New Rock Joint Roughness Quantification Method)

  • 이인모;홍은수;배석일;이석원
    • 한국지반공학회논문집
    • /
    • 제18권4호
    • /
    • pp.229-238
    • /
    • 2002
  • 본 연구에서는 절리면 거칠기를 정량적으로 산출하기 위하여 표면 거칠기 계수, Rs를 이용한 측정방법을 제안하고, 이를 바탕으로 절리면 거칠기가 절리면 전단강도에 미치는 영향을 제시하였다. 제시된 Rs를 이용하여 새로운 절리면 전단강도 모델을 제안하였다. 연구 결과, 표면 거칠기 계수인 Rs는 암반의 절리면 거칠기를 정량적으로 표현할 수 있는 유용한 방법이 될 수 있음을 알 수 있었다. Rs에 의한 암코아 규모의 절리면 거칠기 측정에는 최대 측정간격으로 2mm, 최소 측정 길이로 5cm가 적당하나, 이를 대규모의 현장 절리면에 확대 적용하기 위해서는 변동규모(scale of fluctuation), $\delta_u$를 도입하여야 한다. 절리면 거칠기가 작은 경우, 전단강도는 절리면에서의 미끄러짐으로 유발되었으나, 거친 절리면에서의 전단강도는 거칠기의 일부분이 파괴됨으로 인하여 발생됨을 알 수 있었다.

Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study

  • Lee, Du-Hyeong;An, Seo-Young;Hong, Min-Ho;Jeon, Kyoung-Bae;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권3호
    • /
    • pp.207-213
    • /
    • 2016
  • PURPOSE. A recently introduced direct drill-guiding implant surgery system features minimal tolerance of surgical instruments in the metal sleeve by using shank-modified drills and a sleeve-incorporated stereolithographic guide template. The purpose of this study was to evaluate the accuracy of this new guided surgery system in partially edentulous patients using geometric analyses. MATERIALS AND METHODS. For the study, 21 implants were placed in 11 consecutive patients using the direct drill-guiding implant surgery system. The stereolithographic surgical guide was fabricated using cone-beam computed tomography, digital scanning, computer-aided design and computer-assisted manufacturing, and additive manufacturing processes. After surgery, the positional and angular deviations between planned and placed implants were measured at the abutment level using implant-planning software. The Kruskal-Wallis test and Mann-Whitney U test were used to compare the deviations (${\alpha}=.05$). RESULTS. The mean horizontal deviations were 0.593 mm (SD 0.238) mesiodistally and 0.691 mm (SD 0.344) buccolingually. The mean vertical deviation was 0.925 mm (SD 0.376) occlusogingivally. The vertical deviation was significantly larger than the horizontal deviation (P=.018). The mean angular deviation was 2.024 degrees (SD 0.942) mesiodistally and 2.390 degrees (SD 1.142) buccolingually. CONCLUSION. The direct drill-guiding implant surgery system demonstrates high accuracy in placing implants. Use of the drill shank as the guiding component is an effective way for reducing tolerance.

Ti-6Al-4V 합금의 미세조직 및 크리프 특성에 미치는 플라즈마 침탄 처리의 영향 (Improvement of Microstructure and Creep Properties of Ti-6Al-4V alloy by Plasma Carburization)

  • 박용권;위명용;박정웅
    • 열처리공학회지
    • /
    • 제17권2호
    • /
    • pp.94-100
    • /
    • 2004
  • In order to improve the wear resistance of Ti-6Al-4V alloy, plasma carburization treatment was newly carried out without consumption of its good specific strength and fatigue life over the temperature. Effect of the plasma carburization was analyzed and compared with the non-treated alloy by microstructural observation, structure characterization and mechanical test. The plasma treated alloy formed a carburized layer of about $150{\mu}m$ in depth from the surface, where a fine and hard particles of TiC and $V_4C_3$ were homogeneously dispersed through the layer. The steady-static creep behaviors of Ti-6Al-4V alloy, using the constant stress creep tester, were investigated over the temperature range of $510{\sim}550^{\circ}C$(0.42~0.44Tm) and the stress range of 200~275 MPa. Stress exponent(n) was decreased from 9.32 of non-treatment specimen to 8.95 of carburized, however, the activation energy(Q) increased from 238 to 250 kJ/mol with the same condition as indicated above. From the above results, it can be concluded that the static creep deformation for Ti-6Al-4V alloy was controlled by the dislocation climb over the ranges of the experimental conditions.

Gamma-ray Full Spectrum Analysis for Environmental Radioactivity by HPGe Detector

  • Jeong, Meeyoung;Lee, Kyeong Beom;Kim, Kyeong Ja;Lee, Min-Kie;Han, Ju-Bong
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권4호
    • /
    • pp.317-323
    • /
    • 2014
  • Odyssey, one of the NASA's Mars exploration program and SELENE (Kaguya), a Japanese lunar orbiting spacecraft have a payload of Gamma-Ray Spectrometer (GRS) for analyzing radioactive chemical elements of the atmosphere and the surface. In these days, gamma-ray spectroscopy with a High-Purity Germanium (HPGe) detector has been widely used for the activity measurements of natural radionuclides contained in the soil of the Earth. The energy spectra obtained by the HPGe detectors have been generally analyzed by means of the Window Analysis (WA) method. In this method, activity concentrations are determined by using the net counts of energy window around individual peaks. Meanwhile, an alternative method, the so-called Full Spectrum Analysis (FSA) method uses count numbers not only from full-absorption peaks but from the contributions of Compton scattering due to gamma-rays. Consequently, while it takes a substantial time to obtain a statistically significant result in the WA method, the FSA method requires a much shorter time to reach the same level of the statistical significance. This study shows the validation results of FSA method. We have compared the concentration of radioactivity of $^{40}K$, $^{232}Th$ and $^{238}U$ in the soil measured by the WA method and the FSA method, respectively. The gamma-ray spectrum of reference materials (RGU and RGTh, KCl) and soil samples were measured by the 120% HPGe detector with cosmic muon veto detector. According to the comparison result of activity concentrations between the FSA and the WA, we could conclude that FSA method is validated against the WA method. This study implies that the FSA method can be used in a harsh measurement environment, such as the gamma-ray measurement in the Moon, in which the level of statistical significance is usually required in a much shorter data acquisition time than the WA method.

OECD/NEA BENCHMARK FOR UNCERTAINTY ANALYSIS IN MODELING (UAM) FOR LWRS - SUMMARY AND DISCUSSION OF NEUTRONICS CASES (PHASE I)

  • Bratton, Ryan N.;Avramova, M.;Ivanov, K.
    • Nuclear Engineering and Technology
    • /
    • 제46권3호
    • /
    • pp.313-342
    • /
    • 2014
  • A Nuclear Energy Agency (NEA), Organization for Economic Co-operation and Development (OECD) benchmark for Uncertainty Analysis in Modeling (UAM) is defined in order to facilitate the development and validation of available uncertainty analysis and sensitivity analysis methods for best-estimate Light water Reactor (LWR) design and safety calculations. The benchmark has been named the OECD/NEA UAM-LWR benchmark, and has been divided into three phases each of which focuses on a different portion of the uncertainty propagation in LWR multi-physics and multi-scale analysis. Several different reactor cases are modeled at various phases of a reactor calculation. This paper discusses Phase I, known as the "Neutronics Phase", which is devoted mostly to the propagation of nuclear data (cross-section) uncertainty throughout steady-state stand-alone neutronics core calculations. Three reactor systems (for which design, operation and measured data are available) are rigorously studied in this benchmark: Peach Bottom Unit 2 BWR, Three Mile Island Unit 1 PWR, and VVER-1000 Kozloduy-6/Kalinin-3. Additional measured data is analyzed such as the KRITZ LEU criticality experiments and the SNEAK-7A and 7B experiments of the Karlsruhe Fast Critical Facility. Analyzed results include the top five neutron-nuclide reactions, which contribute the most to the prediction uncertainty in keff, as well as the uncertainty in key parameters of neutronics analysis such as microscopic and macroscopic cross-sections, six-group decay constants, assembly discontinuity factors, and axial and radial core power distributions. Conclusions are drawn regarding where further studies should be done to reduce uncertainties in key nuclide reaction uncertainties (i.e.: $^{238}U$ radiative capture and inelastic scattering (n, n') as well as the average number of neutrons released per fission event of $^{239}Pu$).

국내 음용지하수의 수리지화학 및 자연방사성물질 환경 특성 (Hydrogeochemical Characteristics and Natural Radionuclides in Groundwater for Drinking-water Supply in Korea)

  • 정도환;김문수;이영준
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제16권6호
    • /
    • pp.133-142
    • /
    • 2011
  • A total of 247 samples were collected from groundwater being used for drinking-water supply, and hydrogeochemistry and radionuclide analysis were performed. In-situ analysis of groundwaters resulted in ranges of $13.7{\sim}25.1^{\circ}C$ for temperature, 5.9~8.5 for pH, 33~591 mV for Eh, $66{\sim}820{\mu}S/cm$ for EC, and 0.2~9.4 mg/L for DO. Major cation and anion concentrations of groundwaters were in ranges of 0.5~227.6 for Na, 1.0~279.3 for Ca, 0.0~9.3 for K, 0.1~100.1 for Mg, 0.0~3.3 for F, 0.9~779.1 for Cl, 0.3~120.4 for $SO_4$, 0.0~27.4 for $NO_3$-N, and 6~372 mg/L for $HCO_3$. Uranium-238 and radon-222 concentrations were detected in ranges of N.D-$131.1{\mu}g/L$ and 18-15,953 pCi/L, respectively. In case of some groundwaters exceeding USEPA MCL level ($30{\mu}g/L$) for uranium concentration, their pH ranged from 6.8 to 8.0 and Eh showed a relatively low value(86~199 mV) compared to other areas. Most groundwaters belonged to Ca-(Na)-$HCO_3$ type, and groundwaters of metamorphic rock exhibited the highest concentration of Na, Mg, Ca, Cl, $NO_3$-N, U, and those of plutonic rock showed the highest concentration of $HCO_3$, and Rn. Uranium and fluoride from granite areas did not show any correlation. However, uranium and bicarbonate displayed a positive relation of some areas in plutonic rocks($R^2$=0.3896).

RTA 방법에 의해 Zn 도핑된 InP의 오믹저항 특성연구 (Study on Ohmic resistance of Zn-doping InP using RTA method)

  • 김효진;김인성;김태언;김상택;김선훈;기현철;이경민;양명학;고항주;김회종
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.237-238
    • /
    • 2008
  • 본 연구에서는 APD 소자 제작시 주로 쓰이는 RTA에 의한 Zn 확산방법에 사용할 경우 undoped InP의 V/III비율에 따른 Zn원자의 확산, 도핑, 오믹저항의 성장을 조사하였다. RTA에 의한 확산 및 활성화 열처리 시 도핑 농도의 프로파일은 확산열처리만 한 경우보다 활성화 처리한 경우 더 커짐을 볼 수 있었다. SIMS 결과 활성화 처리 후 표면쪽에 Zn원자의 약간의 결핍현상을 보이는 데 이는 표면쪽에 Zn원자의 탈착이 약간 이루어지는 것으로 보인다. 이 원인은 결과적으로 오믹저항의 증가를 가져왔다.

  • PDF