• 제목/요약/키워드: ${\omega}-3$

검색결과 2,908건 처리시간 0.024초

모유와 유아용 조제분유의 지질 및 지방산 조성 (Lipid and Fatty Acid Composition of Korean Breast Milk and Infant Formula)

  • 임현숙
    • Journal of Nutrition and Health
    • /
    • 제27권6호
    • /
    • pp.563-573
    • /
    • 1994
  • This study was conducted to compare the lipid content and fatty acid composition of the Korean breast milk produced at 1, 2 and 3 months postpartum with the infant formula produced in Korea. The content of total lipids of the breast milk was low compared with the other data of Korean as well as foreign breast milk, and the content tended to reduce during the progress of lactation. The composition of fatty acids of the breast milk was characterized by low saturated fatty acids(SFA) and high $\omega$3 series of polyunsaturated fatty acids (PUFA), especially 20:5 and 22:6, so the P/S and $\omega$6/$\omega$3 rations were high. The formulas had more total lipids, triglycerides(TG) and phospholipids and less cholesterol(CHOL) and free fatty acids than the breast milk. The cholesterol content of the formulas was around 50% of that of the breast milk, so the CHOL/TG ratio was low. Although the formulas varied in fatty acid composition, the formulas had more SFA and $\omega$6 series of PUFA, but less monounsaturated fatty acids and $\omega$3 series of PUFA than the breast milk. This study shows that there are some differences in lipid content and fatty acid composition between breast milk and infant formula. Therefore, further studies needed to investigate the physiological effect of this difference on lipid metabolism of infants.

  • PDF

나선형 DGS를 이용한 4way Power Divider에 관한 연구 (A Study of 4way Power Divider using Defected Ground Structure with Spiral Shape)

  • 이신재;강정훈;안달
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2004년도 춘계학술대회
    • /
    • pp.151-154
    • /
    • 2004
  • 본 논문에서는 기존 Wilkenson Power Divider의 소형화를 위해 마이크로스트립 선로에 DGS를 삽입하였다. 특성 임피던스 70.7$\Omega$$\lambda$/4 마이 크로스트림 선로를 50$\Omega$ 마이크로스트립 선로에 나선형 DGS를 삽입하여 70.7$\Omega$ 선로를 구현하였다. 이 나선형 DGS를 갖는 마이크로스트립 선로의 소형화를 확인하기 위해 각각 3dB Wilkenson Power Divider와 4way Power Divider를 제작하였다. 제작된 3dB Power Divider는 기존의 3dB Power Divider의 70.7$\Omega$ 전송선로의 길이가 31.95mm인 것에 반해 나선형 DGS를 갖는 50$\Omega$ 전송선로는 21.22mm로 약 10mm (약 $30\%$) 정도 길이가 줄었음을 알 수 있다. 또한 이 3dB Power Divider를 사용하여 4way Power Divider를 구현하였다. 이와 같이 마이크로스트립 선로에 DGS를 삽입함으로 인해 선로의 길이를 줄여 소형화 할 수 있음을 알 수 있다.

  • PDF

저항형 바이오 센서를 위한 브릿지 저항 편차-주기 변환기 (Bridge Resistance Deviation-to-Period Converter for Resistive Biosensors)

  • 정원섭
    • 한국정보전자통신기술학회논문지
    • /
    • 제7권1호
    • /
    • pp.40-44
    • /
    • 2014
  • 저항형 바이오 센서를 인터페이싱하기 위해 브릿지 저항 편차-주기 변환기를 제안한다. 이 변환기는 선형 OTA(linear operational transconductance amplifier)와 전류-제어 발진기(current-controlled oscillator)로 구성된다. 브릿지 옵셋저항이 $1k{\Omega}$일 때, 프리러닝 주기는 1.824 ms이다. 변환기의 변 환 감도는 $0-1.2{\Omega}$의 저항편 범위에서 $3.814ms/{\Omega}$이다. 변환 특성의 선형 에러는 ${\pm}0.004%$이내이다.

잉크젯 프린팅 기술을 이용한 플렉서블 온·습도센서 개발 (Fabrication of Flexible Temperature & Humidity Sensor Using Inkjet-printing Technology)

  • 계지원;한동철;신한재;김헌곤;이왕훈
    • 센서학회지
    • /
    • 제24권2호
    • /
    • pp.119-123
    • /
    • 2015
  • This paper presents the inkjet-printed flexible temperature and humidity sensor(F-TH sensor) using PEDOT:PSS. The series, mesh and parallel type sensing element using PEDOT:PSS ink was printed on the overhead projector(OHP) film. The fabricated sensor of each structure has the temperature sensitivity of $140{\Omega}/^{\circ}C$, $29{\Omega}/^{\circ}C$ and $1.4{\Omega}/^{\circ}C$ with linearity, respectively. Also the fabricated sensor was not only possible to measure a temperature, but also to detect humidity. The humidity sensitivity of $400{\Omega}/%RH$, $3.4{\Omega}/%RH$ and $3{\Omega}/%RH$ with linearity, respectively. The fabricated F-TH sensor is expected for the various applications such as electronic devices, bio-healthcare, industrial field.

디메틸아크릴아마이드 변성 폴리오가노실록산을 이용한 액상 실리콘 고무의 제조와 그 특성 (Preparation and Characteristics of Liquid Silicone Rubber Using Polyorganosiloxane Modified with Dimethylacrylamide)

  • 강두환;이병철
    • 폴리머
    • /
    • 제28권2호
    • /
    • pp.143-148
    • /
    • 2004
  • 옥타메틸싸이클로테트라실록산과 1,3,5-트리메틸싸이클로트리실록산 및 1,3,5,7-테트라비닐-1,3,5,7-테트라메틸싸이클로테트라실록산을 테트라메틸암모늄 실록산올레이트 촉매 하에서 1,1,3,3-테트라메틸디실록산과 평형중합으로 이들을 공중합시켜 $\alpha$,$\omega$-하이드로겐 폴리(메틸-디메틸-메틸비닐)실록산 전구체를 제조하였다. 제조된 $\alpha$,$\omega$-하이드로겐 폴리(메틸-디메틸-메틸비닐)실록산 전구체에 디메틸아크릴아마이드를 백금촉매 작용 하에서 반응시켜 아크릴아마이드 변성 $\alpha$,$\omega$-하이드로겐 폴리(메틸-디메틸-메틸비닐)실록산 전구체 (APMDMS)를 제조하였으며 여기에 금속산화물인 NiO, FeO를 배위결합시켜 금속산화물이 2차 결합으로 부가된 APMDMS-MO를 제조하였다. 제조된 화합물의 구조를 FT-IR과 $^1$H-NMR로 분석하여 확인하였다. $\alpha$,$\omega$-비닐 폴리디메틸실록산과 APMDMS-MO를 백금촉매 존재 하에서 컴파운딩시켜 금속산화물 함유 액상 실리콘 고무 복합체를 제조하였으며 이 화합물을 이용하여 제조된 쉬이트의 열 전도도는 0.29 W/mW로 액상 실리콘 고무 복합체의 0.215 W/mK 보다 우수하였고 체적 저항은 1.64${\times}$$10^{5}$$\Omega$ㆍcm로 낮은 값을 나타내었다. 또한 디메틸아크릴아마이드 변성 액상 실리콘 고무 복합체의 기계적 및 열적특성은 UTM과 TGA로 측정하였다.다.

가변 스펙트럼 할당을 지원하는 광대역 전력 증폭기를 위한 디지털 전치왜곡기 (Digital predistorters for communication systems with dynamic spectrum allocation)

  • 최성호;서성원;마백일;정의림
    • 한국정보통신학회논문지
    • /
    • 제15권2호
    • /
    • pp.307-314
    • /
    • 2011
  • 인지통신(cognitive radio)과 같이 가변 스펙트럼 할당이 필요한 시스템을 위한 새로운 전치왜곡기를 제안한다. 본 논문에서 고려하는 시스템 모델에서 신호는 한 순간에는 작은 대역폭을 차지하지만 그 중심 주파수가 시간에 따라 변화할 수 있는 상황을 가정한다. 이러한 시나리오에서는 전력 증폭기 출력 단에 위치하는 종단 필터로는 전력증폭기에 의한 하모닉을 제거하지 못하는 상황이 발생할 수 있다. 제안된 전치왜곡기는 기본 주파수 (${\omega}_0$) 신호의 비선형 왜곡을 선형화할 뿐만 아니라, $2{\omega}_0$, $3{\omega}_0$, ...에서 발생하는 하모닉도 동시에 제거한다. 제안된 전치왜곡기는 ${\omega}_0$ 주파수의 정수배에 대응하는 여러 개의 전치왜곡기가 결합된 구조를 가지고 있다. 기본 주파수 ${\omega}_0$에 해당하는 전치왜곡기는 기본 주파수 신호의 선형화를 담당하며, 나머지 주파수에 대응하는 전치왜곡기는 하모닉을 제거하는 역할을 담당한다. 제안된 전치왜곡기에서 필요한 변수는 최소 평균 자승 에러 알고리즘에 의해 동시에 계산되며, 모의실험 결과에 따르면 제안된 방법을 이용하면 기본 주파수의 스펙트럼에 발생하는 스펙트럼 왜곡이 20dB 감소하며, 2차 및 3차 하모닉도 기본 신호의 전력대비 약 -70dB로 작아지는 것을 확인할 수 있다.

Association between fish and shellfish, and omega-3 PUFAs intake and CVD risk factors in middle-aged female patients with type 2 diabetes

  • Kim, Hyesook;Park, Seokyung;Yang, Hyesu;Choi, Young Ju;Huh, Kap Bum;Chang, Namsoo
    • Nutrition Research and Practice
    • /
    • 제9권5호
    • /
    • pp.496-502
    • /
    • 2015
  • BACKGROUND/OBJECTIVES: This study was performed to investigate the association between the dietary intake of fish and shellfish, and omega-3 polyunsaturated fatty acids (PUFAs) and cardiovascular disease (CVD) risk factors in the middle-aged Korean female patients with Type 2 diabetes (T2D). SUBJECTS/METHODS: A cross-sectional analysis was performed with 356 female patients (means age: 55.5 years), who were recruited from the Huh's Diabetes Clinic in Seoul, Korea between 2005 and 2011. The dietary intake was assessed by a validated semi-quantitative food frequency questionnaire and analyzed using the Computer Aided Nutritional Analysis program (CAN-Pro) version 4.0 software. RESULTS: In a multiple regression analysis after the adjustment for confounding factors such as age, BMI, duration of diagnosed T2D, alcohol consumption, fiber intake, sodium intake, and total energy intake, fish and shellfish intake of the subjects was negatively associated with triglyceride and pulse wave velocity (PWV). Omega-3 PUFAs intake was negatively associated with triglyceride, systolic blood pressures, diastolic blood pressures, and PWV. The multiple logistic regression analysis with the covariates showed a significant inverse relationship between the omega-3 PUFAs consumption and prevalence of hypertriglyceridemia [OR (95% CI) for greater than the median compared to less than the median: 0.395 (0.207-0.753)]. CONCLUSIONS: These results suggest that the consumption of fish and shellfish, good sources of omega-3 PUFAs, may reduce the risk factors for CVD in the middle-aged female patients with T2D.

Effect of omega-3 plus methylphenidate as an alternative therapy to reduce attention deficit-hyperactivity disorder in children

  • Mohammadzadeh, Soleiman;Baghi, Narmin;Yousefi, Fayegh;Yousefzamani, Bahar
    • Clinical and Experimental Pediatrics
    • /
    • 제62권9호
    • /
    • pp.360-366
    • /
    • 2019
  • Background: Attention deficit-hyperactivity disorder (ADHD) is one of the most common chronic behavioral disorders in school-aged children. Purpose: This study aimed to evaluate the effect of omega-3 supplementation as an alternative therapy for ADHD, which can be caused by vitamin and mineral deficiencies. Methods: This was a double-blinded clinical trial study. Sixty-six children with ADHD (aged 6-12 years) referred to our child and adolescent psychiatric educational and therapeutic clinic were selected based on Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision criteria. Instruments including the Parent ADHD Rating Scale were used to assess ADHD at 0, 2, 4, and 8 weeks during the study. Results: The results showed no statistically significant difference between the methylphenidate with omega-3 group and methylphenidate with placebo group based on the Parents ADHD Rating Scale between week 0 ($P{\geq}0.96$) and week 8 ($P{\geq}0.75$). There were no significant intergroup differences between the Inattention ($P{\geq}0.48$) and hyperactivity/impulsivity ($P{\geq}0.80$) subscale scores on the Parents ADHD Rating Scale. The most common drug complications in the methylphenidate with placebo and methylphenidate with omega-3 groups were anorexia (27 [54%] vs. 41 [60.29%], respectively) and diarrhea (10 [20%] vs. 8 [11.76%], respectively), but the differences were not statistically significant (P>0.05). Conclusion: Our results demonstrate that a specific dose of omega-3 for 8 weeks had no effect on ADHD.

앉았다 일어나는 동작동안 단축회전반경 무릎인공관절 수술자와 다축회전반경 무릎인공관절 수술자의 운동역학적 비교분석 (A Biomechanical Comparative Analysis between Single-Radius and Multi-Radius Total Knee Arthroplasty for Sit-to-Stand Movement)

  • 진영완
    • 생명과학회지
    • /
    • 제16권5호
    • /
    • pp.773-779
    • /
    • 2006
  • 단축범위 무릎인공관절 수술자와 다축범위 무릎인공관절 수술자를 대상으로 앉았다 일어나는 동안 운동학적 및 운동역학적 요인들을 비교분석한 결과는 다음과 같다. 앉았다 일어나는 동작은 다축범위 수술자 집단이 단축범위 수술자 집단보다 0.19초(p= 0.033) 빠르게 나타났다. 최대상체 굴곡각도는 다축범위 수술자 집단이 단축범위 수술자집단 보다 $10^{\circ}(p=0.014)$정도 크게 나타났다. 상체굴곡 각속도는 다축범위 수술자 집단이 단축범위 수술자 집단보다 $7^{\Omega}{\cdot}S^{-1}$(p= 0.058)빠르게 나타났다. 단축범위 수술자 집단과 다축범위 수술자 집단의 ADD와 ABD의 차이는 거의 없었다. 대퇴사두근의 근전도분석은 내측광근은 무릎굴곡각 $60^{\Omega}-15^{\Omega}$(p<0.05)에서 단축범위 수술자 집단 근전도 값이 다축범위 수술자집단 근전도값 보다 작게 나타났다. 외측광근은 무릎굴곡각 $60^{\Omega}-45^{\Omega}$(p<0.05)에서 단축범위 수술자 집단 근전도 값이 다축범위 수술자집단 근전도값 보다 작게 나타났다. 대퇴직근의 값은 무릎굴곡각 $60^{\Omega}-30^{\Omega}$(p<0.05)에서 단축범위 수술자 집단 근전도 값이 다축범위 수술자집단 근전도값 보다 작게 나타났다. 대퇴이두근의 값은 무릎굴곡각 $75^{\Omega}-15^{\Omega}$(p<0.05)에서 단축범위 수술자 집단 근전도 값이 다축범위 수술자집단 근전도값 보다 작게 나타났다.

신축 전자패키지 배선용 금속박막의 신축변형-저항 특성 I. Parylene F 중간층 및 PDMS 기판의 Swelling에 의한 영향 (Stretchable Deformation-Resistance Characteristics of Metal Thin Films for Stretchable Interconnect Applications I. Effects of a Parylene F Intermediate Layer and PDMS Substrate Swelling)

  • 박동현;오태성
    • 마이크로전자및패키징학회지
    • /
    • 제24권3호
    • /
    • pp.27-34
    • /
    • 2017
  • Polydimethylsiloxane (PDMS) 신축기판과 Au 박막 사이의 중간층으로서 parylene F의 적용 가능성을 분석하고, Au 박막의 스퍼터링 중에 발생하는 PDMS 기판의 swelling이 Au 박막의 신축변형-저항 특성에 미치는 영향을 분석하였다. Parylene F 중간층 없이 PDMS 기판에 스퍼터링한 150 nm 두께의 Au 박막은 $11.7{\Omega}$의 초기저항을 나타내었으며, 12.5%의 인장변형률에서 저항의 overflow가 발생하였다. 반면에 150 nm 두께의 parylene F 중간층을 갖는 Au 박막의 초기저항은 $1.21{\Omega}$이었으며 30% 인장변형률에서 저항이 $246{\Omega}$으로 저항증가비가 현저히 낮아졌다. PDMS 기판의 swelling이 발생함에 따라 30% 인장변형률에서 Au 박막의 저항이 $14.4{\Omega}$으로 크게 저하되었다.