• Title/Summary/Keyword: ${\mu}$-approach

Search Result 453, Processing Time 0.029 seconds

Alignment of Microbeads Using Spinning Helical Minichannel Cartridge (회전하는 나선형 미니채널 카트리지를 이용한 미세입자 정렬)

  • Kim, Subin;Prasad, Bibin;Kim, Jung Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.3
    • /
    • pp.38-45
    • /
    • 2016
  • Separation of particles based on different sizes, detection of pathogenic bacteria and isolation of leukocytes from whole blood are typical applications of spiral or helical microchannels. The present study focuses on developing a CD4+ T-cell counting device for monitoring HIV/AIDS patients with the aid of a helical minichannel used for a sample cartridge. For the experiment, $10{\mu}m$ sized microbeads were used for visualization with a fluorescence imaging system. Alignment of microbeads was investigated in a stationary and spinning sample cartridge filled with glycerol-water mixtures of different densities. The helical minichannel was spun using a DC motor controlled by an Arduino board with a Bluetooth shield. It was found that when the sample cartridge was made stationary, no bead alignment was achieved for a medium with density (0% and 20% glycerol) lower than that of the beads, but when it was spun at 2000-3000 rpm for 1-4 min, an alignment was obtained at the top of the channel facilitating optical detection and enumeration of those microbeads. Since an alignment of microbeads was achieved for a medium with density as that of blood plasma, the same approach can be applied for aligning and counting CD4+ T-lymphocytes in whole blood samples collected from patients.

Development of Lateral Flow Immunoassay for Antigen Detection in Human Angiostrongylus cantonensis Infection

  • Chen, Mu-Xin;Chen, Jia-Xu;Chen, Shao-Hong;Huang, Da-Na;Ai, Lin;Zhang, Ren-Li
    • Parasites, Hosts and Diseases
    • /
    • v.54 no.3
    • /
    • pp.375-380
    • /
    • 2016
  • Angiostrongyliasis is difficult to be diagnosed for the reason that no ideal method can be used. Serologic tests require specific equipment and are not always available in poverty-stricken zone and are time-consuming. A lateral flow immunoassay (LFIA) may be useful for angiostrongyliasis control. We established a LFIA for the diagnosis of angiostrongyliasis based on 2 monoclonal antibodies (mAbs) against antigens of Angiostrongylus cantonensis adults. The sensitivity and specificity were 91.1% and 100% in LFIA, while those of commercial ELISA kit was 97.8% and 86.3%, respectively. Youden index was 0.91 in LFIA and 0.84 in commercial ELISA kit. LFIA showed detection limit of 1 ng/ml of A. cantonensis ES antigens. This LFIA was simple, rapid, highly sensitive and specific, which opened an alternative approach for the diagnosis of human angiostrongyliasis.

Electrostatically-Driven Polysilicon Probe Array with High-Aspect-Ratio Tip for an Application to Probe-Based Data Storage (초소형 고밀도 정보저장장치를 위한 고종횡비의 팁을 갖는 정전 구동형 폴리 실리콘 프로브 어레이 개발)

  • Jeon Jong-Up;Lee Chang-Soo;Choi Jae-Joon;Min Dong-Ki;Jeon Dong-Ryeol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.6 s.183
    • /
    • pp.166-173
    • /
    • 2006
  • In this study, a probe array has been developed for use in a data storage device that is based on scanning probe microscope (SPM) and MEMS technology. When recording data bits by poling the PZT thin layer and reading them by sensing its piezoresponse, commercial probes of which the tip heights are typically shorter than $3{\mu}m$ raise a problem due to the electrostatic forces occurring between the probe body and the bottom electrode of a medium. In order to reduce this undesirable effect, a poly-silicon probe with a high aspect-ratio tip was fabricated using a molding technique. Poly-silicon probes fabricated by the molding technique have several features. The tip can be protected during the subsequent fabrication processes and have a high aspect ratio. The tip radius can be as small as 15 nm because sharpening oxidation process is allowed. To drive the probe, electrostatic actuation mechanism was employed since the fabrication process and driving/sensing circuit is very simple. The natural frequency and DC sensitivity of a fabricated probe were measured to be 18.75 kHz and 16.7 nm/V, respectively. The step response characteristic was investigated as well. Overshoot behavior in the probe movement was hardly observed because of large squeeze film air damping forces. Therefore, the probe fabricated in this study is considered to be very useful in probe-based data storages since it can stably approach toward the medium and be more robust against external shock.

A Time-Series Study of Ambient Air Pollution in Relation to Daily Mortality in Incheon, 1998-2001 (인천시 대기오염과 일별 사망의 상관성에 관한 시계열적 연구 (1998년${\sim}$2001년))

  • Cho, Yong-Sung;Lee, Jong-Tae;Kim, Yoon-Shin;Hyun, Youn-Joo;Moon, Jeong-Suk
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.89-99
    • /
    • 2003
  • This study is peformed to examine the relationship between air pollution exposure and mortality in Incheon for the years of 1998 - 2001. Daily counts of death were analyzed by general additive Poisson model, with adjustment for effects of seasonal trend, air temperature, humidity, and day of the week as confounders in a nonparametric approach. Daily death counts were associated with CO(1 day before), O$_3$(2 day before), PM$_{10}$(1 day before), NO$_2$(1day before), SO$_2$(1 day before). Increase of 32.21 ${\mu}$g/m$^3$(interquartile range) in PM$_{10}$ was associated with 1.9 % (95% CI = 0.8 % - 2.9 %) increase in the daily number of death. This effect was greater in children(less than 15 aged) and elderly(more than 65 aged). We concluded that Incheon had 2 - 4 % increase in mortality in association with IQR in air pollutants. Daily variations in air pollution within the range currently occurring in Incheon might have an adverse effect on daily mortality. These findings also support the hypothesis that air pollution, at levels below the current ambient air quality standards of Korea, is harmful to sensitive subjects, such as children or elderly.

A Study on the Selective Hole Carrier Extraction Layer for Application of Amorphous/crystalline Silicon Heterojunction Solar Cell (이종접합 실리콘 태양전지 적용을 위한 선택적 전하접합 층으로의 전이금속산화물에 관한 연구)

  • Kim, Yongjun;Kim, Sunbo;Kim, Youngkuk;Cho, Young Hyun;Park, Chang-kyun;Yi, Junsin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.3
    • /
    • pp.192-197
    • /
    • 2017
  • Hydrogenated Amorphous Silicon (a-Si:H) is used as an emitter layer in HIT (heterojunction with Intrinsic Thin layer) solar cells. Its low band gap and low optical properties (low transmittance and high absorption) cause parasitic absorption on the front side of a solar cell that significantly reduces the solar cell blue response. To overcome this, research on CSC (carrier Selective Contacts) is being actively carried out to reduce carrier recombination and improve carrier transportation as a means to approach the theoretical efficiency of silicon solar cells. Among CSC materials, molybdenum oxide ($MoO_x$) is most commonly used for the hole transport layer (HTL) of a solar cell due to its high work function and wide band gap. This paper analyzes the electrical and optical properties of $MoO_x$ thin films for use in the HTL of HIT solar cells. The optical properties of $MoO_x$ show better performance than a-Si:H and ${\mu}c-SiO_x:H$.

Characterization and Comparison of Doping Concentration in Field Ring Area for Commercial Vertical MOSFET on 8" Si Wafer (8인치 Si Power MOSFET Field Ring 영역의 도핑농도 변화에 따른 전기적 특성 비교에 관한 연구)

  • Kim, Gwon Je;Kang, Ye Hwan;Kwon, Young-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.4
    • /
    • pp.271-274
    • /
    • 2013
  • Power Metal Oxide Semiconductor Field Effect Transistor's (MOSFETs) are well known for superior switching speed, and they require very little gate drive power because of the insulated gate. In these respects, power MOSFETs approach the characteristics of an "ideal switch". The main drawback is on-resistance RDS(on) and its strong positive temperature coefficient. While this process has been driven by market place competition with operating parameters determined by products, manufacturing technology innovations that have not necessarily followed such a consistent path have enabled it. This treatise briefly examines metal oxide semiconductor (MOS) device characteristics and elucidates important future issues which semiconductor technologists face as they attempt to continue the rate of progress to the identified terminus of the technology shrink path in about 2020. We could find at the electrical property as variation p base dose. Ultimately, its ON state voltage drop was enhanced also shrink chip size. To obtain an optimized parameter and design, we have simulated over 500 V Field ring using 8 Field rings. Field ring width was $3{\mu}m$ and P base dose was $1e15cm^2$. Also the numerical multiple $2.52cm^2$ was obtained which indicates the doping limit of the original device. We have simulated diffusion condition was split from $1,150^{\circ}C$ to $1,200^{\circ}C$. And then $1,150^{\circ}C$ diffusion time was best condition for break down voltage.

Changes of Plasma Lidocaine Concentrations after Stellate Ganglion Block according to Volume-changes of 1% Lidocaine (성상신경절차단시 주입된 1% Lidocaine 양에 따른 혈중 Lidocaine 농도 변화)

  • Song, Sun-Ok;Suh, Yung-Ho
    • The Korean Journal of Pain
    • /
    • v.14 no.1
    • /
    • pp.26-31
    • /
    • 2001
  • Background: Sympathetic blocks with local anesthetics are used to differentiate sympathetically- maintained pain (SMP) from sympathetically-independent pain (SIP). However, systemic lidocaine is also used in the management of neuropathic pain. Therefore, there may be possibility of a false positive response in relieving their pain by systemic absorption of lidocaine following a diagnostic sympathetic block in patients with SIP. In this study, we measured the plasma lidocaine concentrations after a stellate ganglion block (SGB) using three volumes of 1% lidocaine. Methods: This prospective, crossover study was performed in 3 patients who experience sudden hearing loss and in 4 volunteers. Each person received SGB three times using three different volumes (6 ml, 12 ml and 16 ml) of 1% lidocaine at one week intervals. SGB was performed using a 23 G butterfly needle via a paratracheal approach by two persons. Two ml of venous blood was obtained from a prepared contra-lateral sided venous route at 1, 3, 5, 7, 10, 20 and 60 min after SGB. Plasma lidocaine level was analyzed by immunoassay. Results: Mean plasma lidocaine concentrations correlated well with the volumes of 1% lidocaine used in SGB; larger volumes showed higher concentrations (P < 0.01). Mean peak plasma concentrations were $1.08{\pm}0.18$ in 6 ml, $1.90{\pm}0.47$ in the 12 ml and $2.74{\pm}0.67{\mu}g/ml$ in the 16 ml groups (P < 0.01). The mean time to reach peak plasma concentration was not significantly different between the three groups. Conclusions: The peak plasma lidocaine concentrations in SGB using large volume were found to be similar to that of IV lidocaine infusion in the management of neuropathic pain. These data suggest that diagnostic sympathetic block may result in many false positive responses for SMP. Part of its effect may be related to systemic local anesthetic absorption and not to a sympathetic block. Therefore, physicians may be required to use optimal volumes and minimal concentration of local anesthetic in diagnostic sympathetic block procedures and also make a careful assessment of the performance of a permanent sympathetic block.

  • PDF

Screening and Characterization of an Enzyme with ${\beta}-Glucosidase$ Activity from Environmental DNA

  • Kim, Soo-Jin;Lee, Chang-Muk;Kim, Min-Young;Yeo, Yun-Soo;Yoon, Sang-Hong;Kang, Han-Cheol;Koo, Bon-Sung
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.6
    • /
    • pp.905-912
    • /
    • 2007
  • A novel ${\beta}-glucosidase$ gene, bglA, was isolated from uncultured soil bacteria and characterized. Using genomic libraries constructed from soil DNA, a gene encoding a protein that hydrolyzes a fluorogenic analog of cellulose, 4-methylumbelliferyl ${\beta}-D-cellobioside$ (MUC), was isolated using a microtiter plate assay. The gene, bglA, was sequenced using a shotgun approach, and expressed in E. coli. The deduced 55-kDa amino acid sequence for bglA showed a 56% identity with the family 1 glycosyl hydrolase Chloroflexus aurantiacus. BglA included two conserved family 1 glycosyl hydrolase regions. When using $p-nitrophenyl-{\beta}-D-glucoside$ (pNPG) as the substrate, the maximum activity of the purified ${\beta}-glucosidase$ exhibited at pH 6.5 and $55^{\circ}C$, and was enhanced in the presence of $Mn^{2+}$. The $K_m\;and\;V_{max}$ values for the purified enzyme with pNPG were 0.16 mM and $19.10{\mu}mol/min$, respectively. The purified BglA enzyme hydrolyzed both pNPG and $p-nitrophenyl-{\beta}-D-fucoside$. The enzyme also exhibited substantial glycosyl hydrolase activities with natural glycosyl substrates, such as sophorose, cellobiose, cellotriose, cellotetraose, and cellopentaose, yet low hydrolytic activities with gentiobiose, salicin, and arbutin. Moreover, BglA was able to convert the major ginsenoside $Rb_1$ into the pharmaceutically active minor ginsenoside Rd within 24 h.

Quantitative Analysis of CO2 Reduction by Door-opening in the Subway Cabin (출입문 개폐에 의한 전동차 객실 CO2 저감효과 분석)

  • Kwon, Soon-Bark;Cho, Young-Min;Park, Duck-Shin;Park, Eun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.153-161
    • /
    • 2008
  • The guidelines for indoor air quality of public transportations such as subway, train and bus was presented by Korean Ministry of Environment last end of year 2006 based on the great consequence of indoor air quality in daily life. Two main parameters, carbon dioxide($CO_2$) and particulate matters smaller than $10\;{\mu}m(PM_{10})$, were selected as index pollutants for the management of indoor air quality. The former pollutant, $CO_2$, is regarded as index of ventilation status and the major source of $CO_2$ in the train or subway is the exhalation of passengers. It is publically perceived that the high $CO_2$ concentration in a crowded subway will be reduced and ventilated with outdoor air by door-opening taken every 2 or 3 minutes when the train stops each station. However, there has not been any scientific proof and quantitative information on the effect of door-opening on the $CO_2$ reduction by ventilation with outdoor air. In this study, $CO_2$ concentration and number of passengers were measured at each station on the 3 lines of Korail metropolitan subway. In order to evaluate the effect of $CO_2$ reduction by door opening, the theoretical approach using the $CO_2$ balance equation was performed. By comparing the predicted data with monitoring one, the optimum $CO_2$ dilution factor was determined. For the first time, it was quantified that about 35% of $CO_2$ concentration in the subway indoor was removed by the door-opening at each station.

Alternative Positioning, Navigation, and Timing Applicable to Domestic PBN Implementation (국내 PBN 이행을 위한 대안 항법 적용 방안)

  • Kim, Mu-Geun;Kang, Ja-Young;Chang, Jae-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • Republic of Korea has established its performance-based navigation (PBN) implementation plan in 2010 for ensuring a smooth transition to PBN operations and relevant new flight procedures are being developed in accordance with the roadmap. Various Navigation aids (NAVAIDs) like global navigation satellite systems (GNSS), distance measuring equipment (DME), VHF omnidirectional range (VOR), inertial navigation system (INS) are used to support PBN procedures. Among them, GNSS would play a central role in PBN implementation. However, vulnerability of satellite navigation signals to artificial and natural interferences has been discovered and various alternative positioning, navigation and timing (APNT) technologies are under development in many countries. In this paper, we study whether continuous PBN operations can be achievable without GNSS signals. As a result, it shows that some of the domestic airports require the construction of APNT in the approach area.