• Title/Summary/Keyword: ${\gamma}-rays$

Search Result 596, Processing Time 0.023 seconds

Fabrication of $Li_2B_4O_7$ Series Single-Crystal TLDs and their TL properties ($Li_2B_4O_7$ 계열 단결정 TLD 소자의 제작과 특성)

  • Park, Myeong-Hwan;Park, Kang-Soo
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • High-quality single crystals of pure $Li_2B_4O_7$ as well as $Li_2B_4O_7$ doped with Cu, Mn and Mg impurities (1.0mol%, respectively) have been grown from the melt of $Li_2CO_3+2B_2O_3$ by Czochralski method in platinum crucibles. To study the thermoluminescent properties, $Li_2B_4O_7$ series single crystal TLDs were made by cutting in the size of $4{\times}5{\times}1\;mm^3$. The glow curves show two or three peaks which can be easily deconvoluted. It is observed that room temperature($20{\sim}30^{\circ}C$) fadings of the dosimetric peaks of $Li_2B_4O_7$ series single crystal TLDs were about 10 % for 30 days. The relative photon energy response for $Li_2B_4O_7$ series single crystal TLDs were about 85 % when the responses were normalized to that measured with $^{60}Co\;(1.25\;MeV)\;{\gamma}-rays$. The measured data are in a good agreement with theoretical ones. The $Li_2B_4O_7$ series single crystal TLDs fabricated in this work can be used for monitoring personal and environmental radioactivity.

  • PDF

Selection of Mutant Lines with Useful Traits by Irradiation of Proton Ion Beams and Gamma Ray in Rapeseed (Brassica napus L.) (양성자 및 감마선처리에 의한 유채 유용형질의 변이계통 선발)

  • Kim, Jun-Su;Eun, Jong-Seon
    • Korean Journal of Breeding Science
    • /
    • v.43 no.2
    • /
    • pp.145-153
    • /
    • 2011
  • To develop new varieties of rapeseed (Brassica napus L.), the seeds of three varieties 'Naehan', 'Tammi', and 'Halla' were treated with proton ion beams and gamma rays (0~2,000 Gy), and then the characteristics of the mutants induced were examined up to $M_5$ generation to select the lines with fixed useful traits. In $M_5$ generation, we had selected several lines that were highly fixed for some useful traits such as plant height, maturity and flower size; one line with both earlier maturity and shorter stem than wild type, one line with only earlier maturity, two lines with shorter stem, one line with large flower, and one line with chlorophyll mutation. Among them, NP600-1-1-198-2 (induced from variety 'Naehan' was treated with proton ion beams 600 Gy) was superior for its distinction from the original variety, uniformity and stability. The unique characteristics of NP600-1-1-198-2 were dark green leaves, green stem, yellow flower, and black seed coat. Its flowering date was April 14, eight days earlier than its original variety, while seed maturity date was June 16 (five days earlier) and plant height 105 cm (shorter by 10 cm). NP600-1-1-198-2 has 52 silique per panicle, 6.2 cm silique length, 23 seeds per silique, 4.2 g per 1000 seeds and 45.9% oil content. The seed oil contained 67.8% of oleic acid, 16.7% of linoleic acid and 7.3% of linolenic acid but no erucic acid.

Analysis of Radiation Dose Enhancement for Spread Out Bragg-peak of Proton (확산된 피크의 양성자에서 선량 증강 현상에 대한 분석)

  • Hwang, Chulhwan;Kim, JungHoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.253-260
    • /
    • 2019
  • Radiation dose enhancement is a method of increasing the cross section of interaction, thus increasing the deposited dose. This can contribute to linear energy transfer, LET and relative biological effectiveness, RBE. Previous studies on dose enhancement have been mainly focused on X, ${\gamma}-rays$, but in this study, the dose enhancement was analyzed for proton using Monte Carlo simulation using MCNP6. Based on the mathematical modeling method, energy spectrum and relative intensity of spread out Bragg-peak were calculated, and evaluated dose enhancement factor and dose distribution of dose enhancement material, such as aurum and gadolinium. Dose enhancement factor of 1.085-1.120 folds in aurum, 1.047-1.091 folds in gadolinium was shown. In addition, it showed a decrease of 95% modulation range and practical range. This may lead to an uncertain dose in the tumor tissue as well as dose enhancement. Therefore, it is necessary to make appropriate corrections for spread out Bragg-peak and practical range from mass stopping power. It is expected that Monte Carlo simulation for dose enhancement will be used as basic data for in-vivo and in-vitro experiments.

Borehole Elemental Concentration Logs: Theory, Current Trends and Next Level (암석구성성분검층: 원리, 연구동향 및 향후 과제)

  • Shin, Jehyun;Hwang, Seho
    • Geophysics and Geophysical Exploration
    • /
    • v.22 no.3
    • /
    • pp.149-159
    • /
    • 2019
  • Borehole elemental concentration logging, measuring neutron-induced gamma rays by inelastic scattering and neutron capture interactions between neutron and formation, delivers concentrations of the most common elements found in the minerals and fluids of subsurface formation. X-ray diffraction and X-ray fluorescence analysis from core samples are traditionally used to understand formation composition and mineralogy, but it represents only part of formations. Additionally, it is difficult to obtain elemental analysis over the whole intervals because of poor core recovery zones such as fractures or sand layers mainly responsible for groundwater flow. The development of borehole technique for in situ elemental analysis plays a key role in assessing subsurface environment. Although this technology has advanced consistently starting from conventional and unconventional resources evaluation, it has been considered as exclusive techniques of some major service company. As regards domestic research and development, it has still remained an unexplored field because of some barriers such as the deficiency of detailed information on tools and calibration facility for chemistry and mineralogy database. This article reviews the basic theory of spectroscopy measurements, system configuration, calibration facility, and current status. In addition, this article introduces the domestic researches and self-development status on borehole elemental concentration tools.

DOI Detector Design using Different Sized Scintillators in Each Layer (각 층의 서로 다른 크기의 섬광체를 사용한 반응 깊이 측정 검출기 설계)

  • Seung-Jae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.11-16
    • /
    • 2023
  • In preclinical positron emisson tomography(PET), spatial resolution degradation occurs outside the field of view(FOV). To solve this problem, a depth of interaction(DOI) detector was developed that measures the position where gamma rays and the scintillator interact. There are a method in which a scintillation pixel array is composed of multiple layers, a method in which photosensors are arranged at both ends of a single layer, a method in which a scintillation pixel array is constituted in several layers and a photosensor is arranged in each layer. In this study, a new type of DOI detector was designed by analyzing the characteristics of the previously developed detectors. In the two-layer detector, different sizes of scintillation pixels were used for each layer, and the array size was configured differently. When configured in this form, the positions of the scintillation pixels for each layer are arranged to be shifted from each other, so that they are imaged at different positions in a flood image. DETECT2000 simulation was performed to confirm the possibility of measuring the depth of interaction of the designed detector. A flood image was reconstructed from a light signal acquired by a gamma-ray event generated at the center of each scintillation pixel. As a result, it was confirmed that all scintillation pixels for each layer were separated from the reconstructed flood image and imaged to measure the interaction depth. When this detector is applied to preclinical PET, it is considered that excellent images can be obtained by improving spatial resolution.

Alterations in the Properties of Agar by ionizing Radiation

  • Lee, Su-Rae;Park, Sang-Ki;Cho, Han-Ok
    • Nuclear Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.145-150
    • /
    • 1976
  • Alkali-treated red algae, Gracilaria sp. was irradiated with various doses of cobalt-60 gamma-rays and the yeild and properties of agar extracted from the seaweed were examined and compared with the quality of commercial agar powder after irradiation. Extraction yield of agar from irradiated seaweed was proportionally increased as the radiation dose was raised up to 2 Mrad whereas it tended to decrease slightly thereafter. Gelation ability, gelation point, gel hardness and specific viscosity of the agar were increased up to 1 Mrad and decreased at higher dose levels while its melting point, total nitrogen, crude ash and total sulfur decreased up to 1 Mrad level and remained unchanged thereafter. Irradiation of commercial agar powder caused remarkable decreases in the gelation ability, specific viscosity and gel hardness and slight decreases in the gelation point and melting point. The pattern of alterations in the properties of agar samples differed whether the polysaccharide was irradiated in free state or bound state in seaweed.

  • PDF

ANALYSIS OF CHARGE COLLECTION EFFICIENCY FOR A PLANAR CdZnTe DETECTOR

  • Kim, Kyung-O;Kim, Jong-Kyung;Ha, Jang-Ho;Kim, Soon-Young
    • Nuclear Engineering and Technology
    • /
    • v.41 no.5
    • /
    • pp.723-728
    • /
    • 2009
  • The response property of the CZT detector ($5{\times}5{\times}5\;mm^3$), widely used in photon spectroscopy, was evaluated by considering the charge collection efficiency, which depends on the interaction position of incident radiation, A quantitative analysis of the energy spectra obtained from the CZT detector was also performed to investigate the tail effect at the low energy side of the full energy peak. The collection efficiency of electrons and holes to the two electrodes (i.e., cathode and anode) was calculated from the Hecht equation, and radiation transport analysis was performed by two Monte Carlo codes, Geant4 and MCNPX. The radiation source was assumed to be 59.5 keV gamma rays emitted from a $^{241}Am$ source into the cathode surface of this detector, and the detector was assumed to be biased to 500 V between the two electrodes. Through the comparison of the results between the Geant4 calculation considering the charge collection efficiency and the ideal case from MCNPX, an pronounced difference of 4 keV was found in the full energy peak position. The tail effect at the low energy side of the full energy peak was confirmed to be caused by the collection efficiency of electrons and holes. In more detail, it was shown that the tail height caused by the charge collection efficiency went up to 1000 times the pulse height in the same energy bin at the calculation without considering the charge collection efficiency. It is, therefore, apparent that research considering the charge collection efficiency is necessary in order to properly analyze the characteristics of CZT detectors.

TID and SEL Testing on PWM-IC Controller of DC/DC Power Buck Converter (DC/DC 강압컨버터의 PWM-IC 제어기의 TID 및 SEL 실험)

  • Lho, Young Hwan;Hwang, Eui Sung;Jeong, Jae-Seong;Han, Changwoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.1
    • /
    • pp.79-84
    • /
    • 2013
  • DC/DC switching power converters are commonly used to generate a regulated DC output voltage with high efficiency. The DC/DC converter is composed of a PWM-IC (pulse width modulation-integrated circuit) controller, a MOSFET (metal-oxide semiconductor field effect transistor), inductor, capacitor, etc. It is shown that the variation of threshold voltage and the offset voltage in the electrical characteristics of PWM-IC increase by radiation effects in TID (Total Ionizing Dose) testing at the low energy ${\gamma}$ rays using $^{60}Co$, and 4 heavy ions applied for SEL (Single Event Latch-up) make the PWM pulse unstable. Also, the output waveform for the given input in the DC/DC converter is observed by the simulation program with integrated circuit emphasis (SPICE). TID testing on PWM-IC is accomplished up to the total dose of 30 krad, and the cross section($cm^2$) versus LET($MeV/mg/cm^2$) in the PWM operation is studied at SEL testing after implementation of the controller board.

Biological indicator on radiation exposure using apoptosis in adult and newborn mice (성숙 및 신생마우스에서 아포프토시스를 이용한 방사선 피폭의 생물학적 지표)

  • Oh, Heon;Lee, Song-eun;Yang, Jung-ah;Jeong, Kyu-shik;Hyun, Byung-hwa;Kim, Sung-ho
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.4
    • /
    • pp.679-685
    • /
    • 1998
  • We have studied, by a nonisotopic in situ DNA end-labeling (ISEL) technique, frequency of apoptosis in the external granular layer (EGL) of the cerebellum after whole-body irradiation of newborn mice and intestinal crypt cell of adult mice by gamma-rays from $^{60}Co$. The extent of changes following 2 Gy(10.9 Gy/min) was studied at 2, 4, 6, 8, 12, or 24h after exposure. The maximal frequency was found 4-8h after exposure. The mice that received 0.18, 0.36, 0.54, 1.08, 1.98, or 3.96 Gy were examined 6h after irradiation. Measurements performed after irradiation showed a dose-related increase in apoptotic cells in each of the mice studied. The dose-response curves were analyzed by a linear-quadratic model; frequency(%) of apoptotic cell in the newborn mice cerebellum was ($13.49{\pm}1.175$)D+$(-1.52{\pm}0.334)D^2$+0.048($r^2=0.981$, D = dose in Gy) and frequency(number per crypt) of apoptotic cell in the intestinal crypt of adult mice was ($3.857{\pm}0.420$)D+$(-0.535{\pm}0.120)D^2$+0.155($r^2=0.952$, D = dose in Gy). It provides the basis required for a better understanding of results which will be obtained in any further studies for biological responses of radiation using newborn and adult mice.

  • PDF

Response of LiF Thermoluminescent Dosimeter to Gamma-Rays as a Cavity Detector (LiF 열형광선량계(熱螢光線量計)의 감마선(線)에 대한 공동검출기(空洞檢出器)로서의 감응(感應))

  • Ha, C.W.;Yook, C.C.;Jun, J.S.
    • Journal of Radiation Protection and Research
    • /
    • v.1 no.1
    • /
    • pp.10-14
    • /
    • 1976
  • Influence of the cavity size on the response of LiF TLD was theoretically investigated for a presumed system of spherical TLD cavity imbedded in a medium of polyethylene. Calculation of the response for different radii of the spherical cavity was carried out as a function of incident photon energy, applying recent cavity theory. The range of the radii covers 1.578 to 6.528 mm, while that of the incident photon energies extends from 0.02 to 3.0 MeV. As a results, the response of the LiF TLD imbedded in a medium as a cavity was found to be functions of its own size as wall as the incident photon energy.

  • PDF