• Title/Summary/Keyword: ${\gamma}$-ray activity

Search Result 162, Processing Time 0.025 seconds

Effects of Ionizing Radiation on Postharvest Fungal Pathogens

  • Jeong, Rae-Dong;Shin, Eun-Jung;Chu, Eun-Hee;Park, Hae-Jun
    • The Plant Pathology Journal
    • /
    • v.31 no.2
    • /
    • pp.176-180
    • /
    • 2015
  • Postharvest diseases cause losses in a wide variety of crops around the world. Irradiation, a useful nonchemical approach, has been used as an alternative treatment for fungicide to control plant fungal pathogens. For a preliminary study, ionizing radiations (gamma, X-ray, or e-beam irradiation) were evaluated for their antifungal activity against Botrytis cinerea, Penicillium expansum, and Rhizopus stolonifer through mycelial growth, spore germination, and morphological analysis under various conditions. Different fungi exhibited different radiosensitivity. The inhibition of fungal growth showed in a dose-dependent manner. Three fungal pathogens have greater sensitivity to the e-beam treatment compared to gamma or X-ray irradiations. The inactivation of individual fungal-viability to different irradiations can be considered between 3-4 kGy for B. cinerea and 1-2 kGy for P. expansum and R. stolonifer based on the radiosensitive and radio-resistant species, respectively. These preliminary data will provide critical information to control postharvest diseases through radiation.

Development of Effective ${\gamma}$-ray and ${\beta}$-ray Detection Methods For Low-Level Radioactive Wastes (극저준위 방사성 폐기물을 위한 효율적인 ${\gamma}$-선 및 ${\beta}$-선 측정 방법 개발)

  • Kwak, Sung-Woo;Yeom, Yu-Sun;Kim, Ho-Kyung;Cho, Gyu-Seong;Park, Joo-Wan;Kim, Chang-Lak;Song, Myung-Jae
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.393-398
    • /
    • 2001
  • The non-combustible RI wastes disposed of in hospital every year emit ${\gamma}$-ray or ${\beta}$-ray but their activities are very low to the extent of background. Development of more simple methods is needed because the conventional detection methods are so ineffective and complex. In this study, to solve this problem, detection method using efficiency curve for ${\gamma}$-ray emitting radioactive wastes measurement is proposed and experimental detection efficiency equation is also determined through HPGe's standard specimen measurement. For ${\beta}$-emitting radioisotopes detection, new measurement method using detection efficiency estimated by Monte Carlo simulation and SBD measurements is also proposed. According to the results of this paper, the unknown activity of low-level radioactive wastes without LSC requiring the preparation of standard sample and measurement for standard source detection efficiency could be determined efficiently and simply about ${\pm}17%$ in errors by using the theoretical detection efficiency and the SBD measurement result.

  • PDF

Development of Fiber-optic Radiation Sensor Using LYSO Scintillator for Gamma-ray Spectroscopy (LYSO 섬광체를 이용한 감마선 분광용 광섬유 방사선 센서의 개발)

  • Han, Ki-Tek;Yoo, Wook-Jae;Shin, Sang-Hun;Jeon, Da-Yeong;Park, Jang-Yeon;Park, Byung-Gi;Lee, Bong-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.287-292
    • /
    • 2012
  • A fiber-optic radiation sensor was fabricated using a sensing probe, a plastic optical fiber, a photomultiplier tube, and a multichannel analyzer for gamma-ray spectroscopy. As an inorganic scintillator of the sensing probe, a LYSO crystal was used. In this study, we obtained the relationship between the photon counts of the fiber-optic radiation sensor and the activity of the radioactive isotope. In addition, the gamma-ray energy spectra were also measured using a fiber-optic radiation sensor to discriminate species of gamma-ray emitters.

Pin Power Distribution Determined by Analyzing the Rotational Gamma Scanning Data of HANARO Fuel Bundle

  • Lee, Jae-Yun;Park, Hee-Dong
    • Nuclear Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.452-461
    • /
    • 1998
  • The pin power distribution is determined by analyzing the rotational gamma scanning data for 36 element fuel bundle of HANARO. A fission monitor of Nb$^{95}$ is chosen by considering the criteria of the half-life, fission yield, emitting ${\gamma}$-ray energy and probability. The ${\gamma}$-ray spectra were measured in Korea Atomic Energy Research Institute(KAERI) by using a HPGe detector and by rotating the fuel bundle at steps of 10$^{\circ}$. The counting rates of Nb$^{95}$ 766 keV ${\gamma}$-rays are determined by analyzing the full absorption peak in the spectra. A 36$\times$36 response matrix is obtained from calculating the contribution of each rod at every scanning angle by assuming 2-dimensional and parallel beam approximations for the measuring geometry. In terms of the measured counting rates and the calculated response matrix, an inverse problem is set up for the unknown distribution of activity concentrations of pins. To select a suitable solving method, the performances of three direct methods and the iterative least-square method are tested by solving simulation examples. The final solution is obtained by using the iterative least-square method that shows a good stability. The influences of detection error, step size of rotation and the collimator width are discussed on the accuracy of the numerical solution. Hence an improvement in the accuracy of the solution is proposed by reducing the collimator width of the scanning arrangement.

  • PDF

Polysaccharide Extracted from Rheum Tanguticum Prevents Irradiation-induced Immune Damage in Mice

  • Liu, Lin-Na;Guo, Zhi-Wei;Zhang, Yan;Qin, Hua;Han, Yan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.4
    • /
    • pp.1401-1405
    • /
    • 2012
  • Aim: To investigate the protective effect of purified fraction 1 polysaccharide extracted from Rheum tanguticum RTP1 on irradiation-induced immune damage in mice. Methods: Kunming mice were randomly divided into five groups: normal group (NC), irradiation control group (IC), RTP1 low dose (200 mg/kg), middle dose (400 mg/kg) and high dose (800 mg/kg) groups. RTP1 was adminstered by the gastric route for 14 d, mice in the NC and IC groups being given by 0.9% sodium chloride solution in the same way. The mice in all groups except NC group were irradiated with 2.0 Gy $^{60}Co{\gamma}$-ray on the fourteenth day. Immune indives of non-specific immune function, cellular immunity and humoral immunity were assessed at the 24th hour after radiation. Results: Compared with the IC group, the spleen index, thymus index, rate of carbon clearance, phagocytic function of macrophages, lymphocyte proliferation, hemolysin value of blood serum and NK activity were increased markedly (P < 0.05 or P < 0.05). Conclusion: RTP1 has an obvious protective effects on damage in ${\gamma}$-ray radiated mice.

Formation of Carboxymethyl Cellulose Hydrogel Containing Silver Nanoparticle (은 나노입자를 함유하는 카르복시메틸 셀룰로오스 하이드로겔 제조)

  • Park, Jong-Seok;Kuang, Jia;Gwon, Hui-Jeong;Lim, Youn-Mook;Nho, Young-Chang
    • Journal of Radiation Industry
    • /
    • v.4 no.4
    • /
    • pp.353-357
    • /
    • 2010
  • Silver nanoparticles (AgNPs) can be used in the areas such as integrate circuit, cell electrode and antimicrobial deodorant. In this study, AgNPs have been prepared by using $AgNO_3$ aqueous solution in the carboxymethyl cellulose (CMC) hydrogel. CMC powders were dissolved in deionized water, and then irradiated by a gamma-ray with a radiation dose of 50 kGy to make CMC hydrogel. CMC hydrogels were dipped into $1.0{\times}10^{-2}M$ $AgNO_3$ solution for 1 hour. After that, the swollen hydrogels were irradiated by gamma-ray for the formation of AgNPs. The characteristics of silver nanoparticles in the CMC hydrogels were monitored by UV-Vis and the morphological study and dispersed coefficient of particles were investigated by FE-SEM/EDX. It was observed that the sodium salt in the CMC is crucial to the formation of silver nanoparticle. Finally, antibacterial tests indiacted that the hydrogel containing silver nanoparticle has antibacterial activity.

Identification Of Jet Components Of CTA 102 On Milliarcsecond Scales Using The iMOGABA Program

  • Kim, Sang-Hyun;Lee, Sang-Sung;Hodgson, Jeffrey A.;Lee, Jee Won;Kang, Sincheol;Yoo, Sung-Min
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.76.1-76.1
    • /
    • 2019
  • CTA 102, one of gamma-ray bright active galactic nuclei (AGN) has been observed with Korean very long baseline interferometry (VLBI) network (KVN) during the period of 2012 December-2018 May as part of interferometric Monitoring Of Gamma-ray Bright AGN (iMOGABA). Multi-frequency VLBI observations enable us to compare the milliarcsecond(mas)-scale iMOGABA images of relativistic jets with those from the Monitoring Of Jets in AGN with Very long baseline array (VLBA) Experiments (MOJAVE) and the VLBA-Boston University(BU)-BLAZAR programs which use VLBA with its angular resolutions of 0.2-1.3 mas. In spite of the relative larger beam sizes of KVN (1-10 mas), we are able to identify jet components of CTA 102 using the KVN multi-frequency VLBI observations with those resolved with VLBA. Considering an instrumental beam blending effect on the jet component identification, we were able to obtain a blending shift of the core position based on a convolution analysis using the VLBA data. When we apply the core position shift to the KVN images of CTA 102, we find that the identified jet components of CTA 102 from the KVN observations are well matched with those from the VLBA observations. Based on the results of the analysis, we may be able to study the jet kinematics and its correlation with gamma-ray flare activity.

  • PDF

Effects of Electron-Beam Irradiation on Saponins and Physio-chemical Properties of Ginseng Powders (Electron Beam 조사가 인삼분말의 사포닌 및 생리화학적 특성에 미치는 영향)

  • 이미경;이종원;도재호;권중호
    • Food Science and Preservation
    • /
    • v.10 no.2
    • /
    • pp.206-212
    • /
    • 2003
  • Comparative effects of electron beam and gamma-ray irradiation (25 ∼15 kGy) were investigated on saponin stability and some physiological and chemical properties of white and red ginseng powders. Saponin components were found stable upon irradiation of both energies when determined by TLC and HPLC, after 4 months of storage at room temperature as well as immediately after treatment The contents of total phenolics and acidic polysaccharides of the samples were higher in red ginseng than in white. Polysaccharide contents increased with irradiation doses. Amylase activity of white ginseng was stimulated by irradiation but decreased with the lapse of storage time. There were no apparent differences in electrophoresis patterns of extracted proteins depending on irradiation doses and energy sources.

Preparation of Silver Nanoparticles on the Poly(vinyl alcohol)/poly(ethylene glycol) Hydrogel (Poly(vinyl alcohol)/poly(ethylene glycol) 하이드로겔에서의 silver nanoparticles의 제조)

  • Park, Jong-Seok;Kim, Hyun-A;Choi, Jong-Bae;Gwon, Hui-Jeong;Lim, Youn-Mook;Nho, Young-Chang
    • Journal of Radiation Industry
    • /
    • v.5 no.2
    • /
    • pp.119-124
    • /
    • 2011
  • Silver nano-particles (AgNPs) have attracted much attention for centuries due to their unique optical properties, electrical conductivities, oxidative catalysis, and antibacterial effect. In this study, AgNPs have been prepared by using aqueous $AgNO_3$ solution in the poly(vinyl alcohol) (PVA)/poly(ethylene glycol) (PEG) hydrogels. PVA and PEG powders were dissolved in deionized water, and then irradiated by a gamma-ray with a radiation dose of 50 kGy to make hydrogels. PVA/PEG hydrogels were dipped into $1.0{\times}10^{-2}M$ $AgNO_3$ solution for 1 hour. After that, the swollen hydrogels were irradiated by gamma-ray for the formation of AgNPs. FE-SEM is used to observe the formation of AgNPs as a function of the content of PEG and the irradiation dose. Also, AgNPs in the PVA/PEG hydrogels were monitored by UV-Vis. It is observed that the content of PEG and gamma-ray irradiation in the hydrogel is crucial to the formation of AgNPs. Finally, antibacterial tests indiacted that the hydrogel containing silver nanoparticle has antibacterial activity.

Impact of aperture-thickness on the real-time imaging characteristics of coded-aperture gamma cameras

  • Park, Seoryeong;Boo, Jiwhan;Hammig, Mark;Jeong, Manhee
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1266-1276
    • /
    • 2021
  • The mask parameters of a coded aperture are critical design features when optimizing the performance of a gamma-ray camera. In this paper, experiments and Monte Carlo simulations were performed to derive the minimum detectable activity (MDA) when one seeks a real-time imaging capability. First, the impact of the thickness of the modified uniformly redundant array (MURA) mask on the image quality is quantified, and the imaging of point, line, and surface radiation sources is demonstrated using both cross-correlation (CC) and maximum likelihood expectation maximization (MLEM) methods. Second, the minimum detectable activity is also derived for real-time imaging by altering the factors used in the image quality assessment, consisting of the peak-to-noise ratio (PSNR), the normalized mean square error (NMSE), the spatial resolution (full width at half maximum; FWHM), and the structural similarity (SSIM), all evaluated as a function of energy and mask thickness. Sufficiently sharp images were reconstructed when the mask thickness was approximately 2 cm for a source energy between 30 keV and 1.5 MeV and the minimum detectable activity for real-time imaging was 23.7 MBq at 1 m distance for a 1 s collection time.