• Title/Summary/Keyword: ${\gamma}$-Ray radiation

Search Result 886, Processing Time 0.028 seconds

Determination of the Optimum Dose Range for a Mutation Induction of Turfgrasses by a Gamma-Ray (잔디류 돌연변이 유기를 위한 적정 방사선 선량범위의 결정)

  • Lee, Hye-Jung;Lee, Geung-Joo;Kim, Dong-Sub;Kim, Jin-Baek;Ku, Ja-Hyeong;Kang, Si-Yong
    • Asian Journal of Turfgrass Science
    • /
    • v.22 no.1
    • /
    • pp.25-34
    • /
    • 2008
  • This study was conducted to determine the optimum dose ranges for a mutation breeding based on the observations of a seed germination and an early growth in turfgrasses. Three warm season (Zoysiagrass, Bermudagrass, and Seashore paspalum) and four cool season turfgrasses (Kentucky bluegrass, Tall fescue, Perennial ryegrass, and Creeping bentgrass) were used in this study. We investigated the percentage of a seed germination and a seedling growth after irradiating the turfgrass seeds with various doses of gamma-ray (50, 100, 150, 200, 250, 300, 400, and 500 Gy). After 24 h with a gamma irradiation, the seeds were sown on the wet filter paper in a petri dish and maintained for 3 weeks at 30$^{\circ}C$ for the warm season turfgrasses and at 25$^{\circ}C$ for the cool season turfgrasses. Data on a seed germination and a seedling growth with three replications were collected. The percentage of seed germination was decreased with an increase of the gamma-ray dose. Shoot and root growth, and the fresh weight were decreased significantly as the radiation dose was increased. A radiation dose indicating a 50% growth inhibition ($LD_{50}$) with a gamma irradiation was varied among those turfgrass species used, with the highest at about 500 Gy for bermudagrass and the lowest at 100Gy for tall fescue. The optimum dose for a gamma irradiation for a selection of turfgrass mutants was considered to be about 300, 150, 500, 150, 200, 100 and 200 Gy for zoysiagrass, seashore paspalum, bermudagrass, Kentucky bluegrass, perennial ryegrass, tall fescue, and creeping bentgrass, respectively.

Development of a flexible composite based on vulcanized silicon casting with bismuth oxide and characterization of its radiation shielding effectiveness in diagnostic X-ray energy range and medium gamma-ray energies

  • Ibrahim Demirel;Haluk Yucel
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2570-2575
    • /
    • 2024
  • The study aims to develop a novel, lead-free, flexible and lightweight composite shielding material against ionizing radiation. For this, it was used bismuth oxide (Bi2O3) in RTV-2 silicon matrix. The shielding tests were carried out in both diagnostic X-ray energies and intermediate gamma-ray energy range of up to 662 keV to determine the radiation attenuation properties of this material in terms of attenuation ratio, half value layer, tenth value layer, mean free path and lead equivalency of samples in weight of 30%, 40%, 50% in Bi2O3. In the diagnostic X-ray energy range, half value layer, tenth value layer and lead equivalency (in mm Pb) of the produced samples were measured at 80 and 100 kVp narrow beam conditions according to the requirements of EN IEC 61331-1 standard. The results show that lead equivalent values of the produced novel sheets was measured to be 0.16 mm Pb, corresponding to a 6 mm thickness of the flexible sample when it contains 30% wt. Bi2O3 in RTV matrix. The experimental findings for durability and flexibility also indicated that this new RTV-based flexible, lead -free shielding composite can be used safely for especially for manufacturing aprons, garments and thyroid guards used in mammography, radiology, nuclear medicine and dental applications in practice.

Application of Commercial PIN Photodiodes to develope Gamma-Ray Dosimeters (감마선 선량계를 개발하기 위한 상용 PIN 포토 다이오드의 응용)

  • Jeong, Dong-Hwa;Kim, Sung-Duck
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.274-280
    • /
    • 2000
  • This paper deals with an experimental study to apply commercial semiconductors to measure radiation dose rate for gamma ray. Since the low cost, small size, high efficiency and ruggedness of silicon photodiodes make them attractive photodetectors, they coulde be effectively used in measuring any radiation such as gamma ray. Most PN photodiodes show that the reverse current increases when the light is increased. Therefore the depletion region of them have influence on the reverse current, so we choose silicon PIN photodiodes with large depletion region. In order to detect radiation dose rate and then, to apply in developing any gamma ray dosimeter, some examinations and experiments were performed to PIN photodiodes in this work. Two kinds of PIN photodiodes, such as NEC's PH302 and SIEMENS's BPW34, were tested in a Co-60 gamma irradiation facility with a semiconductor parameter analyzer. As a result, we found that such PIN photodiodes present good linearity in diode current characteristics with dose rate. Therefore silicon PIN photodiodes could be suitably used in designing gamma ray dosimeters.

  • PDF

Gamma-ray Exposure Rate Monitoring by Energy Spectra of NaI(Tl) Scintillation detectors

  • Lee, Mo Sung
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.3
    • /
    • pp.158-165
    • /
    • 2017
  • Background: Nuclear facilities in South Korea have generally adopted pressurized ion chambers to measure ambient gamma ray exposure rates for monitoring the impact of radiation on the surrounding environment. The rates assessed with pressurized ion chambers do not distinguish between natural and man-made radiation, so a further step is needed to identify the cause of abnormal variation. In contrast, using NaI(Tl) scintillation detectors to detect gamma energy rates can allow an immediate assessment of the cause of variation through an analysis of the energy spectra. Against this backdrop, this study was conducted to propose a more effective way to monitor ambient gamma exposure rates. Materials and Methods: The following methods were used to analyze gamma energy spectra measured from January to November 2016 with NaI detectors installed at the Korea Atomic Energy Research Institute (KAERI) dormitory and Hanbat University. 1) Correlations of the variation of rates measured at the two locations were determined. 2) The dates, intervals, duration, and weather conditions were identified when rates increased by $5nSv{\cdot}h^{-1}$ or more. 3) Differences in the NaI spectra on normal days and days where rates spiked by $5nSv{\cdot}h^{-1}$ or more were studied. 4) An algorithm was derived for automatically calculating the net variation of the rates. Results and Discussion: The rates measured at KAERI and Hanbat University, located 12 kilometers apart, did not show a strong correlation (coefficient of determination = 0.577). Time gaps between spikes in the rates and rainfall were factors that affected the correlation. The weather conditions on days where rates went up by $5nSv{\cdot}h^{-1}$ or more featured rainfall, snowfall, or overcast, as well as an increase in peaks of the gamma rays emitted from the radon decay products of $^{214}Pb$ and $^{214}Bi$ in the spectrum. This study assumed that $^{214}Pb$ and $^{214}Bi$ exist at a radioactive equilibrium, since both have relatively short half-lives of under 30 minutes. Provided that this assumption is true and that the gamma peaks of the 352 keV and 1,764 keV gamma rays emitted from the radionuclides have proportional count rates, no man-made radiation should be present between the two energy levels. This study proved that this assumption was true by demonstrating a linear correlation between the count rates of these two gamma peaks. In conclusion, if the count rates of these two peaks detected in the gamma energy spectrum at a certain time maintain the ratio measured at a normal time, such variation can be confirmed to be caused by natural radiation. Conclusion: This study confirmed that both $^{214}Pb$ and $^{214}Bi$ have relatively short half-lives of under 30 minutes, thereby existing in a radioactive equilibrium in the atmosphere. If the gamma peaks of the 352 keV and 1,764 keV gamma rays emitted from these radionuclides have proportional count rates, no man-made radiation should exist between the two energy levels.

Green synthesis of Lead-Nickel-Copper nanocomposite for radiation shielding

  • B.M. Chandrika;Holaly Chandrashekara Shastry Manjunatha;R. Munirathnam;K.N. Sridhar;L. Seenappa;S. Manjunatha;A.J. Clement Lourduraj
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4671-4677
    • /
    • 2023
  • For the first time Pb, Ni, and Cu nanocomposites were synthesized by versatile solution combustion synthesis using Aloevera extract as a reducing agent, to study the potential applications in X-ray/gamma, neutron, and Bremsstrahlung shielding. The synthesized Lead-Nickel-Copper (LNC) nanocomposites were characterized by PXRD, SEM, UV-VIS, and FTIR for the confirmation of successful synthesis. PXRD analysis confirmed the formation of multiphase LNC NCs and the Scherrer equation and the W-H plot gave the average crystal sizes of 19 nm and 17 nm. Surface morphology using SEM and EDX confirmed the presence of LNC NCs. Strong absorption peaks were analyzed by UV visible spectroscopy and the direct energy gap is found to be 3.083 eV. Functional groups present in the LNC NCs were analyzed by FTIR spectroscopy. X-ray/gamma radiation shielding properties were measured using NaI(Tl) detector coupled with MCA. It is found to be very close to Pb. Neutron shielding parameters were compared with traditional shielding materials and found LNC NCs are better than lead and concrete. Secondary radiation shielding known as Bremsstrahlung shielding characteristics also studied and found that LNC NCs are best in secondary radiation shielding. Hence LNC NCs find shielding applications in ionizing radiation such as X-ray/gamma and neutron radiation.

Shielding 140 keV Gamma Ray Evaluation of Dose by Depth According to Thickness of Lead Shield (140 keV 감마선 차폐 시 납 차폐체 두께에 따른 깊이별 선량 평가)

  • Kim, Ji-Young;Lee, Wang-Hui;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.129-134
    • /
    • 2018
  • The present study made a phantom for gamma ray of 140 keV radiated from $^{99m}Tc$, examined shielding effect of lead by thickness of the shielding material, and measured surface dose and depth dose by body depth. The OSL Nano Dot dosimeter was inserted at 0, 3, 15, 40, 90, and 180 mm depths of the phantom, and when there was no shield, 0.2 mm lead shield, 0.5 mm lead shield, The depth dose was measured. Experimental results show that the total cumulative dose of dosimeters with depth is highest at 366.24 uSv without shield and lowest at 94.12 uSv with 0.5 mm lead shield. The shielding effect of 0.2 mm lead shielding was about 30.18% and the shielding effect of 0.5 mm lead shielding was 74.30%, when the total sum of the accumulated doses of radiation dosimeter was 100%. The phantom depth and depth dose measurements showed the highest values at 0 mm depth for all three experiments and the dose decreases as the depth increases. This study proved that the thicker a shielding material, the highest its shielding effect is against gamma ray of 140 keV. However, it was known that shielding material can't completely shield a body from gamma ray; it reached deep part of a human body. Aside from the International Commission on Radiation Units and Measurements (ICRU) recommending depth dose by 10 mm in thickness, a plan is necessary for employees working in department of nuclear medicine where they deal with gamma ray, which is highly penetrable, to measure depth dose by body depth, which can help them manage exposed dose properly.

Development of Radiation Sensor Based on Array SiPM for Measurement of Radioactive Contamination in Effluent (방류수의 방사능 오염 측정을 위한 배열형 SiPM 기반 방사선 검출 센서 제작)

  • Kim, Jeongho;Park, Hyemin;Joo, Koansik
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.232-236
    • /
    • 2018
  • A radiation detection sensor was developed and characterized by combining three types of CsI(Tl) scintillators and an array-type SiPM to detect the radioactive contamination of discharged water in real time. The characterization results showed that type 3 exhibited the most desirable characteristics in response linearity (R-square: 0.97889) according to detection sensitivity and incident radiation dose. Furthermore, in terms of spectral characteristics, type 3 exhibited 16.54% at 0.356 MeV (the emission gamma ray energy of $^{133}Ba$), 10.28% at 0.511 MeV (the emission gamma ray energy of $^{22}Na$), 9.68% at 0.356 MeV (the emission gamma ray energy of $^{137}Cs$), and 2.55% and 4.80% at 1.173 MeV and 1.332 MeV (the emission gamma ray energies of $^{60}Co$), respectively. These measurements confirmed the good energy characteristics. The results were used to evaluate the spectral characteristics and energy linearity in a mixed source using type 3 with the best detection characteristics. It was confirmed that the gamma ray peaks of $^{133}Ba$, $^{22}Na$, $^{137}Cs$, and $^{60}Co$ were well resolved. Moreover, it was confirmed that R-square, which is an indicator of energy linearity, was 0.99986. This indicates a good linearity characteristic. Based on this study, further commercialization studies will contribute to measurements in real time and to the management of the contamination caused by radioactive wastewater or radioactive material leakage, which originate from facilities that use radioactive isotopes or care facilities.

The Study of Latch-up (과도방사선 조건에서 PN다이오드소자의 방사선 영향분석)

  • Oh, Seung-Chan;Jeong, Sanghun;Hwang, YoungGwan;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.791-794
    • /
    • 2013
  • Electronic systems may be cause of various serious failures due to an ionizing radiation effect when exposed to a prompt gamma-ray pulse. This transient electrical malfunction can, in some cases, results in a failure of the electronic system of which the circuits are a part. Transient radiation measurement and evaluation system is required to development for enhanced radiation-resistance against the initial nuclear radiation produced by the detonation of a nuclear weapon of semiconductor devices. In these studies, we performed the following work. In the first part of the work, we carried out a SPICE simulation applied to nuclear radiation condition for PN diode and we also investigated the photocurrent by a pulsed gamma-ray on a PN diode using a TCAD simulation.

  • PDF

The Characteristic Curves of Commercial Medical X-ray Films (상용 의학용 X-ray 필름의 특성곡선)

  • Heo, Hoon;Jeong, Yeon-Tae;Lee, Jae-Sung
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.19 no.2
    • /
    • pp.12-21
    • /
    • 2001
  • For the purpose of determining characteristics of widely used commercial medical x-ray films, which are used for obtaining the Linac-grams for radiational treatment of cancers, we placed several commercial x-ray films at a fixed distance form the linear accelerator. After varying the exposed amount of radiation step by step, we could obtain a continually increasing density image for each film whose densities were determined by microdensitometer readings. The characteristic curves of the films were obtained by plotting the densities vs. the exposed radiation amounts, and their ${\gamma}$ values were determined. These values can be used to suggest a minimum necessary amount of exposed radiation to get a useful Linac-gram. The measured ${\gamma}$ values of the characteristic curves of the Kodak-DVP/RA-1 film were 1.73 when used 6MV x-ray, 1.70 when used 15MV of intensity. For the Konica-AX film, ${\gamma}$ values were 1.29 and 1.18 respectively. The result suggests that the effective conditions for high resolution of a L-gram be 6 MV of x-ray intensity and about 3 rad of exposed dose on a Kodak-DVP/RA-1 film.

  • PDF

Fabrication and Characterization of PVA/CMC Hydrogels by Freezing-Thawing Technique and Gamma-Ray Irradiation (동결/융해와 방사선 가교법에 의한 PVA/CMC 수화젤의 제조 및 특성 평가)

  • Jo, Sun-Young;Lim, Youn-Mook;Youn, Min-Ho;Gwon, Hui-Jeong;Park, Jong-Seok;Nho, Young-Chang;Shin, Heung-Soo
    • Polymer(Korea)
    • /
    • v.33 no.6
    • /
    • pp.551-554
    • /
    • 2009
  • Poly (vinyl alcohol) (PVA) and carboxymethyl cellulose (CMC) have received increasing attention in biomedical and biochemical applications because of their properties such as being water-soluble and biocompatible. In this study, a PVA/CMC hydrogel applicable to artificial cartilage was prepared by a freezing-thawing technique and a gamma-ray irradiation. The solid concentration of PVA was 7 wt% and the concentration of CMC was 4 wt%. The freezing/thawing process was repeated twice and the dose of gamma-ray irradiated was 30 kGy. Results of gelation before and after gamma-ray irradiation were similar, but the swelling degree decreased and compressive strength increased. The cytotoxicity was investigated with CCK-8 assay.