• Title/Summary/Keyword: ${\gamma}$-선

Search Result 1,548, Processing Time 0.028 seconds

Protective Effect of a Herbal Preparation (HemoHIM) on the Self-Renewal Tissues and Immune System against γ-Irradiation (방사선에 대한 생약복합조성물(HemoHIM)의 재생조직 및 면역계 방호 · 회복촉진 효과)

  • Jo, Sung-Kee;Park, Hae-Ran;Jung, Uhee;Oh, Heon;Kim, Sung-Ho;Yee, Sung-Tae
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.6
    • /
    • pp.805-813
    • /
    • 2005
  • In our previous study, a novel herb mixture (HIM-I) of Angelim gigas radix, Cnidium officinale rhizoma, and Paeonia japonica radix was developed to protect the intestinal and immune systems and promote its recovery against radiation damage. In this study, a new herbal preparation (HemoHIM) with the high immune modulating activity was developed from HIM-I. HIM-I was fractionated into ethanol fraction (HIM-I-E) and polysaccharide fraction (HIM-I-P). And HemoHIM was prepared by adding HIM-I-P to HIM-I. The protective activities against $\gamma$ -irradiation were compared among HemoHIM, HIM-I and the fractions. HemoHIM and HIM-I significantly decreased the radiation-induced DNA damage in vitro, and scavenged hydroxyl radicals in a dose-dependent manner. HemoHIM showed similar activity to HIM-I. In vitro proliferation assay with mouse lymphocytes and bone marrow cells showed that HIM-I-P was remarkably higher than HIM-I and HIM-I-E in cell proliferating activity. HemoHIM showed higher activity than HIM-I and this might be associated with the higher polysaccharide content. The in vivo protective effects of HemoHIM and HIM-I were investigated in $\gamma$-irradiated mice. HemoHIM increased the surviving intestinal crypts to a similar extent compared with HIM-I. In contrast, HemoHIM appeared to be more effective than HIM-I in endogenous spleen colony formation assay. The recovery of white blood cells and lymphocytes in irradiated mice were significantly enhanced by the administration of HemoHIM. Also HemoHIM administration prolonged the survival of irradiated mice. These results showed that the novel herbal preparation, HemoHIM, effectively protected the self-renewal tissues and immune system, and promoted the survival of irradiated mice. Moreover, in comparison with HIM-I, HemoHIM maintained similar activity in the reduction of oxidative damage of self-renewal tissue but exhibited the higher activity in protection and proliferation of immune and hematopoietic cells. These results suggested that HemoHIM might be more effective than HIM-I in immune modulation as well as radioprotection.

Effects of Ethanol Extracts from Zingiber officinale Rosc., Curcuma longa L., and Curcuma aromatica Salisb. on Acetylcholinesterase and Antioxidant Activities as well as GABA Contents (생강, 울금, 강황 추출물의 항산화 효과, AChE 억제활성 및 GABA 함량)

  • Jung, Yeon-Seop;Park, Sung-Jin;Park, Jung-Hyun;Jhee, Kwang-Hwan;Lee, In-Seon;Yang, Seun-Ah
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.10
    • /
    • pp.1395-1401
    • /
    • 2012
  • This study investigated the cognition-related effects on antioxidant activities, ${\gamma}$-aminobutyric acid (GABA) contents, and AChE inhibitory activities in ethanol extracts from Zingiber officinale Rosc. (Korea), Curcuma longa L. (Korea), Curcuma longa L. (Myanmar), and Curcuma aromatica Salisb. (India). These extracts were investigated to determine the relationships among total polyphenols as well as DPPH and ABTS radical scavenging activities, GABA contents, and acetylcholinestrase (AChE) inhibitory activity. For the results, C. longa L. from Myanmar exhibited the highest contents of curcumin (97.1 ${\mu}g/mg$), total polyphenols (98.4 ${\mu}g/mg$), and GABA (1.31 ${\mu}g/mg$), as well as the strongest radical scavenging activities and AChE inhibitory activity. In addition, C. aromatica Salisb from India, which had the highest total polyphenol content (98.4 ${\mu}g/mg$) and strongest radical scavenging activities, exhibited relatively high AChE inhibitory activity similar to that of C. longa L. from Myanmar. On the other hand, Z. officinale Rosc. and C. longa L. from Korea showed low contents of curcumin (12.2 ${\mu}g/mg$) and polyphenols (85.7 ${\mu}g/mg$), as well as low AChE inhibitory activities. However, we could detect 1.11 ${\mu}g/mg$ of GABA in these extracts, which was similar to that of C. longa L. from Myanmar. Therefore, GABA content was not correlated with AChE inhibitory activity. Based on the results, AChE inhibitory activity is highly correlated with polyphenol contents in Zingibearceae family. Overall, among the Zingiberaceae tested, C. longa L. from Myanmar might be a strong candidate as a cognitive-enhancing ingredient.

Growth of CdSe thin films using Hot Wall Epitaxy method and their photoelectrical characteristics (HWE방법에 의한 CdSe 박막 성장과 광전기적 특성)

  • Hong, K.J.;Lee, K.K.;Lee, S.Y.;You, S.H.;Shin, Y.J.;Suh, S.S.;Jeong, J.W.;Jeong, K.A.;Shin, Y.J.;Jeong, T.S.;Kim, T.S.;Moon, J.D.;Kim, H.S.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.328-336
    • /
    • 1997
  • The CdSe thin films were grown on the Si(100) wafers by a hot wall epitaxy method (HWE). The source and substrate temperature are $600^{\circ}C$ and $430^{\circ}C$ respectively. The crystalline structure of epilayers was investigated by double crystal X-ray diffraction(DCXD). Hall effect on the sample was measured by the van der Pauw method and studied on the carrier density and mobility dependence on temperature. From Hall data, the mobility was increased in the temperature range 30K to 150K by impurity scattering and decreased in the temperature range 150k to 293k by the lattice scattering. In order to explore the applicability as a photoconductive cell, we measured the sensitivity(${\gamma}$), the ratio of photocurrent to darkcurrent(pc/dc), maximum allowable power dissipation(MAPD), spectral response and response time. The results indicated that the photoconductive characteristic were the best for the samples annealed in Cu vapor compare with in Cd, Se, air and vacuum vapour. Then we obtained the sensitivity of 0.99, the value of pc/dc of $1.39{\times}10^{7}$, the MAPD of 335mW, and the rise and decay time of 10ms and 9.5ms, respectively.

  • PDF

Removal Characteristic of Arsenic by Sand Media Coated with both Iron-oxide and Manganese-oxide (산화철 및 산화망간이 동시에 코팅된 모래 매질을 이용한 비소오염 제거특성 연구)

  • Kim, Byeong-Kwon;Min, Sang-Yoon;Chang, Yoon-Young;Yang, Jae-Kyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.473-482
    • /
    • 2009
  • In this study, iron and manganese coated sand (IMCS) was prepared by mixing Joomoonjin sand with solutions having different molar ratio of manganese ($Mn^{2+}$) and iron ($Fe^{3+}$). Mineral type of IMCS was analyzed by X-ray diffraction spectroscopy. Removal efficiency of arsenic through As(III) oxidation and As(V) adsorption by IMCS having different ratio of Mn/Fe was evaluated. The coated amount of total Mn and Fe on all IMCS samples was less than that on sand coated with iron-oxide alone (ICS) or manganese-oxide alone (MCS). The mineral type of the manganese oxide on MCS and iron oxides on ICS were identified as ${\gamma}-MnO_2$ and mixture of goethite and magnetite, respectively. The same mineral type was appeared on IMCS. Removed amount As(V) by IMCS was greatly affected by the content of Fe rather than by the content of Mn. Adsorption of As(V) by IMCS was little affected by the presence of monovalent and divalent electrolytes. However a greatly reduced As(V) adsorption as observed in the presence of trivalent electrolyte such as $PO_4\;^{3-}$. As(III) oxidation efficiency by MCS in the presence of NaCl or $NaNO_3$ was two times greater than that in the presence of $PO_4\;^{3-}$. Meanwhile a greater As(III) oxidation efficiency was observed by IMCS in the presence of $PO_4\;^{3-}$. This was explained by the competitive adsorption between phosphate and arsenate on the surface of IMCS.

The Correlations of Parameters Using Contrast Enhanced Ultrasonography in the Evaluation of Prostate Cancer Angiogenesis (전립선암쥐모형의 신생혈관생성의 평가를 위해 시행된 역동적 조영 증강 초음파에서 얻은 변수간의 상관성연구)

  • Hwang, Sung Il;Lee, Hak Jong;Kim, Kil Joong;Chung, Jin-haeng;Jung, Hyun Sook;Jeon, Jong June
    • Ultrasonography
    • /
    • v.32 no.2
    • /
    • pp.132-142
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate the correlations of various kinetic parameters derived from the time intensity curve in a xenograft mouse model injected with a prostate cancer model (PC-3 and LNCaP) using an ultrasound contrast agent with histopathologic parameters. Materials and Methods: Twenty nude mice were injected with human prostate cancer cells (15 PC-3 and five LNCaP) on their hind limbs. A bolus of $500{\mu}L$ ($1{\times}10^8$ microbubbles) of second-generation US contrast agent (SonoVue) was injected into the retroorbital vein. The region of interest was drawn over the entire tumor. The time intensity curve was acquired and then fitted to a gamma variate function. The maximal intensity (A), time to peak (Tp), maximal wash-in rate (washin), washout rate (washout), area under the curve up to 50 sec ($AUC_{50}$), area under the ascending slope ($AUC_{in}$), and area under the descending slope ($AUC_{out}$) were derived from the parameters of the gamma variate fit. Immunohistochemical staining for VEGF and CD31 was performed. Tumor volume, the area percentage of VEGF stained in a field, and the count of CD31 (microvessel density, MVD) positive vessels showed correlation with the parameters from the time intensity curve. Results: No significant differences were observed between the kinetic and histopathological parameters from each group. MVD showed positive correlation with A (r=0.625, p=0.003), washin (r=0.462, p=0.040), $AUC_{50}$ (r=0.604, p=0.005), and $AUC_{out}$ (r=0.587, p=0.007). Positive correlations were also observed between tumor volume and $AUC_{50}$ (r=0.481, p=0.032), washin (r=0.662, p=0.001), and $AUC_{out}$ (r=0.547, p=0.012). Washout showed negative correlations with MVD (r=-0.454, p=0.044) and tumor volume (r=-0.464, p=0.039). The area percentage of VEGF did not show any correlation with calculated data from the curve. Conclusion: MVD showed correlations with several of the kinetic parameters. CEUS has the potential for prediction of tumor vascularity in a prostate cancer animal model.

Natural radioactivity of surface sediments by source regions of the asian dust (황사지역 발원지에 따른 표층퇴적물의 자연방사능 특성)

  • Lee, Kil Yong;Yoon, Yoon Yeol;Cho, Soo Young;Koh, Kyung Seok;Kim, Yongje
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.474-479
    • /
    • 2008
  • Radioactivity of naturally occurring radioactive nuclides (NORN) such as $^{226}Ra$, $^{228}Ac$ and $^{40}K$ were investigated for surface sediments collected from Ordos, Alashan, Taklimakan deserts and Loess plateau regions in China. By a Gamma-ray spectrometry, specific activity (SA) and SA ratio (SAR) of the NORN were determined for each source region of Asian dust. Characterization of the source regions of Asian dust was performed with the SA and SAR values. SA of $^{226}Ra$ in the three desert regions have almost same values in the range of mean value 17.9~21.9 Bq/kg, however, the SA in Loess Plateau has much higher values in the mean value of 35 Bq/Kg. SA of $^{228}Ac$ in the Ordos and Alashan desert regions have almost same values in the range of mean value 27.1~27.2 Bq/kg, and those in Taklimakan desert and Loess Plateau were 31.7 and 49.0 Bq/kg, respectively. In case of 40K, the SA in all regions have similar values in the range of 636~943 Bq/kg. The mean SAR value of $^{226}Ra/^{228}Ac$ in four source regions was almost same in the range of 0.708-0.721. It is shown that relationship between $^{226}Ra$ and $^{228}Ac$ is clearly presented in the source regions. The mean SAR values of $^{226}Ra/^{40}K$, $^{228}Ac/^{40}K$ are 0.0209-0.056, 0.0287-0.0773, respectively.

Measurement of MDA of Soil Samples Using Unsuppression System and Compton Suppression of Environmental Radioactivity in Processing Technology (환경 방사능 처리기술에서의 Compton suppression 및 Unsuppression system을 이용한 토양시료의 MDA 측정)

  • Kang, Suman;Im, Inchul;Lee, Jaeseung;Jang, Eunsung;Lee, Mihyeon;Kwon, Kyungtae;Kim, Changtae
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.293-299
    • /
    • 2014
  • Compton suppression device is a device by using the Compton scattering reaction and suppress the Compton continuum portion of the spectrum, so can be made more clear analysis of gamma ray peak in the Compton continuum region. Measurements above background occurs or, radioactivity counts of radioactivity concentration value of $^{40}K$ nuclides $^{137}Cs$ and natural radioactivity artificial radioactivity detected from the surface soil sample, unwanted non-target analysis and interference peak who dotted line you know the calibration of the measurement energy is allowed to apply the (Compton suppression) non-suppressed spectrum inhibition spectrum and (Compton Unsuppression) the background to the measured value of the activity concentration value of the standard-ray source is detected relative to the peak of By measuring according to the different distances cause $^{137}Cs$, and comparative analysis of the Monte Carlo simulation, in order to obtain a detection capability for efficient, looking at the Compton inhibitor, as the CSF value increases with increase in the distance, more It was found that the background due to Compton continuum of the measured spectrum suppression mode Compton unrestrained mode can know that the Compton suppression many were made, using a $^{137}Cs$ is reduced.

Growth and photocurrent study on the splitting of the valence band for $CuInSe_2$ single crystal thin film by hot wall epitaxy (Hot Wall Epitaxy(HWE)범에 의한 $CuInSe_2$ 단결정 박막 성장과 가전자대 갈라짐에 대한 광전류 연구)

  • Hong Myungseak;Hong Kwangjoon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.14 no.6
    • /
    • pp.244-252
    • /
    • 2004
  • A stoichiometric mixture of evaporating materials for $CuInSe_2$ single crystal thin films was prepared from horizontal electric furnace. To obtain the single crystal thin films, $_CuInSe2$ mixed crystal was deposited on thoroughly etched semi-insulating GaAs(100) substrate by the hot wall epitaxy (HWE) system. The source and substrate temperatures were $620^{\circ}C$ and $410^{\circ}C$, respectively. The crystalline structure of the single crystal thin films was investigated by the photoluminescence and double crystal X-ray diffraction (DCXD). The carrier density and mobility of $CuInSe_2$ single crystal thin films measured with Hall effect by van der Pauw method are $9.62\times10^{16}/\textrm{cm}^3$, 296 $\textrm{cm}^2$/Vㆍs at 293 K, respectively. The temperature dependence of the energy band gap of the $CuInSe_2$ obtained from the absorption spectra was well described by the Varshni's relation, $E_g$(T) = 1.1851 eV -($8.99\times10^{-4} eV/K)T^2$(T + 153 K). The crystal field and the spin-orbit splitting energies for the valence band of the CuInSe$_2$ have been estimated to be 0.0087 eV and 0.2329 eV at 10 K, respectively, by means of the photocurrent spectra and the Hopfield quasicubic model. These results indicate that the splitting of the Δso definitely exists in the $\Gamma$6 states of the valence band of the $CuInSe_2$. The three photocurrent peaks observed at 10 K are ascribed to the $A_1-, B_1$-와 $C_1$-exciton peaks for n = 1.

Analysis of the Physical Properties of Ground before and after Low Flowing Grouting (저유동성 그라우팅 시공전후 지반의 물성변화 분석)

  • Seo, Seok-Hyun;Lee, Jung-Sang;Kang, Won-Dong;Jung, Euiyoup
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.115-127
    • /
    • 2019
  • The low-flow grouting injection technique, the target construction method for this study, is a method of pouring mortar into the ground by non-emission replacement principle, which can be expected to increase the density of the ground, and, in some cases, be used as a base file using the strength of the high injection solids, along with low noise, low pollution, and high durability. To verify that the dynamic characteristics of the ground are improved by the low-flow injection technique, the test work was conducted on the site and physical tests were performed, and the quality of the improvement formed in the ground was verified through the indoor test on the core and core recovery rate was analyzed. The density logs test layer calculated the volume density of the ground layer by using the Compton scattering of gamma-rays, and the sonic logs was tested on the ground around the drill hole using a detector consisting of sonar and receiver devices inside the drill hole. As a result of the measurement of the change in physical properties (density and sonic logs) before and after grouting, both properties were basically increased after infusion of grout agent. However, the variation in density increase was greater than the increase in speed after grouting, and the ground density measurement method was thought to be effective in measuring the fill effect of the filler. Strength and core recovery rates were measured from specimens taken after the age of 28 days, and the results of the test results of the diffusion and strength test of the improved products were verified to satisfy the design criteria, thereby satisfying the seismic performance reinforcement.

Change of Dose Distribution on the Beam Axis of 60Co γ Ray and 10MV X-Ray with Part Thickness (치료부위(治療部位)두께에 따른 Co-60 γ선(線)과 10MV X선(線)의 선축상(線軸上) 선량분포(線量分布)의 변화(變化))

  • Kang, Wee Saing;Koh, Kyoung Hwan;Ha, Sung Whan;Park, Charn Il
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.21-24
    • /
    • 1983
  • The thickness of the part being irradiated is finite. Percent depth dose tables being used routinely are generally obtained from dosimetry in a phantom much thickner than usual patient. At or close to exit surface, the dose should be less than that obtained from the percent depth dose tables, because of insufficient volume for backscattering. To know the difference between the true absorbed dose and the dose obtained from percent depth dose table, the doses at or close to the exit surface were measured with plate type ionization chamber with volume of 0.5ml. The results are as follows; 1. In the case of $^{60}Co$, percent depth dose at a given depth increases with underlying phantom thickness up to the 5cm. 2. In the case of $^{60}Co$, the dose correction factor at exit surface which is less than 1, increases with part thickness and decreases with field size. 3. Exposure time may not be corrected when the part above 10cm in thickness is treated by $^{60}Co$. 4. In the case of 10MV x-ray, the dose correction factor is nearly 1 and constant for the underlying phantom thickness and field size, so the correction of monitor unit is not necessary for part thickness.

  • PDF