• Title/Summary/Keyword: ${\beta}$-ray absorption method

Search Result 19, Processing Time 0.026 seconds

Noise Reduction Method for Particle Measurement System using Beta-ray Absorption Method (베타선 흡수법을 이용하는 미세먼지 측정시스템을 위한 잡음제거 방법)

  • Choi, Hun;Sohn, Sang-Wook;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1706-1712
    • /
    • 2012
  • The Beta-ray absorption method (BAM) gives a good solution for measuring the mass concentration of atmospheric particles(PM10 and PM2.5). To determine particular matters (PM) concentration, a ratio of the number of detected beta-ray intensity passing through the clean filter and the dust-sampled filter is used. These intensity data measured in air pollution monitoring such as PM10 and PM2.5 usually contained the additive noise(thermal noise, power supply noise and etc.). Therefore, the estimation performance of mass concentration can be deteriorated by these noises. In this paper, we present a new noise reduction method that is essentially required to develope an automatic continuous PM monitoring system using beta-ray absorption method. By combining the block data averaging technique and curve fitting, in the proposed method, the additive noise can be reduced in the measured data. To evaluate the performance of the proposed method, computer simulations were performed with computer generated signals as the input.

Estimation of the optimal heated inlet air temperature for the beta-ray absorption method: analysis of the PM10 concentration difference by different methods in coastal areas

  • Shin, So Eun;Jung, Chang Hoon;Kim, Yong Pyo
    • Advances in environmental research
    • /
    • v.1 no.1
    • /
    • pp.69-82
    • /
    • 2012
  • Based on the measurement data of the particulate matter with an aerodynamic diameter of less than or equal to a nominal 10 ${\mu}m$ (PM10) by the ${\beta}$-ray absorption method (BAM) equipped with an inlet heater and the gravimetric method (GMM) at two coastal sites in Korea, the optimal inlet heater temperature was estimated. By using a gas/particle equilibrium model, Simulating Composition of Atmospheric Particles at Equilibrium 2 (SCAPE2), water content in aerosols was estimated with varying temperature to find the optimal temperature increase to make the PM10 concentration by BAM comparable to that by GMM. It was estimated that the heated air temperature inside the BAM should be increased up to $35{\sim}45^{\circ}C$ at both sites. At this temperature range, evaporation of volatile aerosol components was minor. Similar ($30{\sim}50^{\circ}C$) temperature range was also obtained from the calculation based on the absolute humidity which changed with ambient absolute humidity and chemical composition of hygroscopic species.

Compensation of Light Scattering Method for Real-Time Monitoring of Particulate Matters in Subway Stations (지하역사 내 미세먼지 실시간 모니터링을 위한 광산란법 보정)

  • Kim, Seo-Jin;Kang, Ho-Seong;Son, Youn-Suk;Yoon, Sang-Lyeor;Kim, Jo-Chun;Kim, Gyu-Sik;Kim, In-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.533-542
    • /
    • 2010
  • The $PM_{10}$ concentrations in the underground should be monitored for the health of commuters on the underground subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. As for the measurement of $PM_{10}$ concentrations, instruments based on $\beta$-ray absorption method and gravimetric methods are being used. But the instruments using gravimetric method give us 20-hour-average data and the $\beta$-ray instruments can measure the $PM_{10}$ concentration every one hour. In order to keep the $PM_{10}$ concentrations under a healthy condition, the air quality of the underground platform and tunnels should be monitored and controlled continuously. The $PM_{10}$ instruments using light scattering method can measure the $PM_{10}$ concentrations every less than one minute. However, the reliability of the instruments using light scattering method is still not proved. The purpose of this work is to study the reliability of the instruments using light scattering method to measure the $PM_{10}$ concentrations continuously in the underground platforms. One instrument using $\beta$-ray absorption method and two different instruments using light scattering method (LSM1, LSM2) were placed at the platform of the Jegi station of Seoul metro line Number 1 for 10 days. The correlation between the $\beta$-ray instrument and the LSM2 ($r^2$=0.732) was higher than that between the $\beta$-ray instrument and the LSM1 ($r^2$=0.393). Thus the LSM2 was chosen for further analysis. Three different regression analysis methods were tested: Linear regression analysis, Nonlinear regression analysis and Orthogonal regression analysis. When the instruments using light scattering method were used, the data measured these instruments have to be converted to actual $PM_{10}$ concentrations using some factors. With these analyses, the factors could be calculated successfully as linear and nonlinear forms with respect to the data. And the orthogonal regression analysis was performed better than the ordinary least squares method by 28.45% reduction of RMSE. These findings propose that the instruments using light scattering method light scattering method can be used to measure and control the $PM_{10}$ concentrations of the underground subway stations.

Study on Inclusion Complex of Fenbufen with ${\beta}-Cyclodextrin$

  • Kim, Young-Il;Park, Young-Ju
    • Journal of Pharmaceutical Investigation
    • /
    • v.14 no.3
    • /
    • pp.136-143
    • /
    • 1984
  • Inclusion complex formation of fenbufen with ${\beta}-cyclodextrin$ in water and in solid state was comfirmed by solubility method, ultra violet absorption, circular dichroism and infra-red spectroscopies, differential thermal analysis, and X-ray diffractometry. A solid complex of fenbufen with ${\beta}-cyclodextrin$ in 1 : 1 molar ratio was prepared by the freeze-drying method, its dissolution characteristics in water and its analgesic and antiinflammatory effect in mouse or rat were examined. The apparent release of fenbufen from the inclusion complex was significantly improved, hut no significant difference in its analgesic and antiinflammatory effect was found.

  • PDF

Analysis of Radiation Dose on Single Cells Using Therapeutic Radioisotopes Using the Monte Carlo Method (몬테카를로 방법을 이용한 치료용 방사성동위원소 사용 시 단일 세포에 대한 선량 분석)

  • Kim, Jung-Hoon;Kim, Yu-Soo
    • Journal of radiological science and technology
    • /
    • v.45 no.5
    • /
    • pp.433-438
    • /
    • 2022
  • Targeted radionuclides treatment (TRT) requires the establishment of treatment plans that consider various factors, such as the type of radionuclides, target organs, and administration methods. For this reason, in this study, the absorption dose of a single cell was analyzed according to the type of radioisotope used to treat target radionuclides. In this study, a simulation was performed on beta rays used in the treatment of target radionuclides at the cell level using MCNPX (ver. 2.5.0). First, according to the calculation formula, the beam path according to the type of radioisotope for treatment was calculated. Second, the amount of self-radiation by beta rays emitted from cell diameters of 5 ㎛ and 10 ㎛ cell nuclei was evaluated. As a result, it showed a high range proportional to the maximum energy of the beta-ray, and the highest self-dose distribution from 177 Lu radiation sources among therapeutic radioisotopes. This was analyzed as a result that is inversely proportional to the maximum energy of the beta-ray, and it suggests that the selection of a nuclide considering the range of the beta-ray is necessary in the treatment of target radionuclides in the future.

Relationships between TSP and PM10 Concentrations in the Ambient Atmosphere (대기 중 TSP와 PM10 농도의 관련성)

  • 최진수;백성옥
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 1998
  • Relationships between TSP and PM10 concentrations were evaluated using their respective data sets collected from Taegu and Kyeungsan areas during the period of December 1993 to November 1994. The collection of data was made using the gravimetric and $\beta$-ray absorption ($\beta$-MPM) methods for 7 days of every month from three urban sites in Taegu and one suburban site in Kyeungsan. Correlation coefficients between TSP and PM10 concentrations for these four sampling sites were found in the range of 0.85 $\sim$ 0.96. Correlation analysis was also conducted for $\beta$-PM concentration data that were measured only from the residential and commercial sites. The correlation coefficients between TSP and $\beta$-PM concentrations were 0.9 in the residential site and 0.8 in the commercial site. By contrast, the correlation coefficients between PM10 $\beta$-PM concentrations were almost identical for both the residential and commercial sites with a value of 0.88. The mean ratio for PM10 to TSP concentrations for all sites was appeared to be 0.68. The analysis of seasonal trends in PM10/TSP ratios showed that the contribution of PM10 to TSP concentrations was more significant during winter (0.70 $\sim$ 0.75) than during summer (0.61 $\sim$ 0.68). The results of this study may provide empirical informations on the compatability of aerosol data measured by different sampling methods.

  • PDF

Solubility and In vivo Absorption Enhancement of Diclofenac Sodium by ${\beta}-Cyclodextrin$ Complexation (${\beta}$-시클로덱스트린과의 포접에의한 디플로페낙나트륨의 용해도 및 생체흡수율 증가)

  • Lee, Kyung-Tae;Kim, Jong-Hwan;Kim, Joo-Il;Kim, Seung-Jo;Seo, Hee-Kyoung;Seo, Seong-Hoon
    • Journal of Pharmaceutical Investigation
    • /
    • v.26 no.3
    • /
    • pp.169-174
    • /
    • 1996
  • Inclusion complexes of diclofenac sodium with ${\beta}-cyclodextrin$ were prepared in aqueous solution, alkaline solution and solid phase. The interaction of diclofenac sodium with ${\beta}-cyclodextrin$ in pH 9.0 alkaline solution was evaluated by the solubility method and the instrumental analysis such as thermal analysis, infrared spectroscopy, X-ray diffractometry. The solubility of diclofenac sodium was increased linearly with the increase in the concentration of ${\beta}-cyclodextrin$up to 0.15 mol and showed that the aqueous solubility rate of diclofenac sodium was significantly increased by complex with ${\beta}-cyclodextrin$. The optimum composition of this complex was one molecule of ${\beta}-cyclodextrin$ included 1.59 molecular weight of diclofenac sodium as a guest molecule. The pharmacokinetic parameters of the diclofenac sodium and the complex with ${\beta}-cyclodextrin$ were studied in rats by oral route. $T_{max}$ between drug alone and inclusion complex showed significant difference to be 120 minute and 20 minute respectively. Both of $C_{max}$ and AUC of inclusion complex was about 40% higher than drug alone. It is estimated from the data in this study that complexation of diclofenac sodium with ${\beta}-cyclodextrin$ increased the absorption rate and improved the bioavalability of the diclofenac sodium by the formation of a water-soluble complexes.

  • PDF

Comparison of the PM10 Concentration in Different Measurement Methods at Gosan Site in Jeju Island (제주도 고산 측정소의 미세먼지 측정방법에 따른 질량농도 비교)

  • Shin, So-Eun;Kim, Yong-Pyo;Kang, Chang-Hee
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.4
    • /
    • pp.421-429
    • /
    • 2010
  • The reliability of the measurement of ambient trace species is an important issue, especially, in background area such as Gosan in Jeju Island. In a previous episodic study, it was suggested that the PM10 measurement result by the gravimetric method(GMM) was not in agreement with the result by the ${\beta}$-ray absorption method(BAM). In this study, a systematic comparison was carried out for the data between 2001 and 2008 at Gosan(GMM and BAM) and Jeju city (BAM) which is near to Gosan. It was found that at Gosan the PM10 concentration by BAM was higher than GMM and the correlation between them was low. The BAM results at Gosan and Jeju city showed similar trend implying the discrepancy at Gosan was not caused by instrumental problem of the BAM at Gosan. Based on the previous studies two probable reasons for the discrepancy are identified; (1) negative measurement error by the evaporation of volatile ambient species at the filter in GMM such as nitrate and ammonium and (2) positive error by the absorption of water vapor during measurement in BAM. There was no heater at the inlet of BAM at Gosan during the sampling period. Based on the size-segregated measurement data, it was identified that the evaporation error was minor, if any. The relationship between the two methods did not vary with the ambient relative humidity. Thus, at present, it is not clear why the discrepancy had been occurring and when using the PM10 data at Gosan, one should be aware the possible errors.

Pharmaceutical Studies on Inclusion Complex of Norfloxacin with ${\beta}-Cyclodextrin$ (Norfloxacin과 ${\beta}-Cyclodextrin$간의 Inclusion Complex에 관한 약제학적 연구)

  • Jee, Ung-Kil;Park, Mork-Soon;Kwon, Joong-Moo
    • Journal of Pharmaceutical Investigation
    • /
    • v.17 no.1
    • /
    • pp.1-14
    • /
    • 1987
  • To increase the bioavailability of norfloxacin, inclusion complex of antimicrobial agent norfloxacin with ${\beta}-Cyclodextrin$ was prepared and studied by the solubility method, spectrophotometric methods(UV, IR, $^1H-NMR$), differential thermal analysis, powder X-ray diffractometry, the physical properties, the antimicrobial activity, DNA binding and in situ recirculation technique. The conclusions are summerized as following; 1) The inclusion complexation was identified by means of solubility, spectrophotometry(UV, IR, NMR), DTA and X-ray diffraction. 2) The molar ratio of $norfloxacin-{\beta}-cyclodextrin$ complex was 1 : 1. 3) The stability constant of $norfloxacin-{\beta}-cyclodextrin$ complex was $21.5\;M^{-1}$, and both true and apparent partition coefficients of the inclusion complex were larger than those of norfloxacin. 4) The time required to dissolve 60% $(T_{60}%)$ of the inclusion complex was 120 min. in distilled water and in the artificial intestinal juice, while norfloxacin did not reach to 60% dissolution within 120 min. 5) The antimicrobial activity of the inclusion complex against Pseudomonas aeruginosa, Klebsiella pneumoniae and Staphylococcus aureus showed no significant difference compared to that of norfloxacin alone. 6) Studies on binding properties between the inclusion complex and norfloxacin alone to DNA according to equilibrium dialysis showed no significant differency. 7) In situ absorption rates (Ka) of inclusion complex and norfloxacin alone were 0.229 and $0.102hr^{-1}$, respectively.

  • PDF

Pharmaceutical Studies on the Inclusion Complexes of Non-Steroidal Antiinflammatory Drugs with ${\beta}-Cyclodextrin$ (I) (비(非)Steroid 성소염약물(性消炎藥物)과 ${\beta}-Cyclodextrin$과의 Inclusion Complex에 관(關)한 약제학적(藥劑學的) 연구(硏究) (제1보)(第一報))

  • Han, Kun;Lee, Min-Hwa;Kim, Shin-Keun
    • Journal of Pharmaceutical Investigation
    • /
    • v.13 no.1
    • /
    • pp.10-22
    • /
    • 1983
  • The interactions of ${\alpha}-cyclodextrin({\alpha}-CyD)$ and ${\beta}-cyclodextrin({\beta}-CyD)$ with several non-steroidal antiinflammatory drugs were studied on the effects of ${\alpha}-$ and ${\beta}-CyD$ on the solubility of the drugs in aqueous medium. Indoprofen, niflumic acid, alclofenac, and naproxen were chosen as representatives of antiinflammatory drugs. The solubility of all drugs studied increased with the addition of ${\beta}-CyD$, while not with glucose or ${\alpha}-CyD$. The increase of the solubility with ${\beta}-CyD$ was considered due mainly to the formation of inclusion complexes between ${\beta}-CyD$ and drugs. From the solubility data, the apparent stability constants K of the complex could be calculated. Ultraviolet absorption and circular dichroism confirmed the inclusion of indoprofen, niflumic acid and naproxen with ${\beta}-CyD$ in the molar ratio of 1 : 1. Inclusion complexes in solid powder form were obtained by the freeze-drying method and the inclusion formation was confirmed again by infrared, diffential thermal analysis, and X-ray diffraction measurements.

  • PDF