• Title/Summary/Keyword: ${\Omega}$-stable

Search Result 174, Processing Time 0.023 seconds

Red Ginseng Saponin Fraction A Isolated from Korean Red Ginseng by Ultrafiltration on the Porcine Coronary Artery

  • Jung, Young-Hyun;Park, Kwang-Yeol;Jeon, Jin-Hong;Kwak, Yi-Seong;Song, Yong-Bum;Wee, Jae-Joon;Rhee, Man-Hee;Kim, Tae-Wan
    • Journal of Ginseng Research
    • /
    • v.35 no.3
    • /
    • pp.325-330
    • /
    • 2011
  • Red ginseng saponin fraction-A (RGSF-A) contains a high percentage of panaxadiol saponins that were isolated from Korean red ginseng by ultrafiltration. The aim of this study was to elucidate the effects of RGSF-A on the porcine distal left anterior descending (LAD) coronary artery. The relaxant responses to RGSF-A were examined during contractions induced by 100 nM U46619 (9,11-dideoxy-9a,11a-methanoepoxy-prostaglandin F2a), a stable analogue of thromboxane A2. RGSF-A dose-dependently induced biphasic (fast- and slow-) relaxation in the distal LAD coronary artery in the presence of an intact endothelium. The fast-relaxation was quickly achieved in a minute, and then the slow-relaxation was slowly developed and sustained for more than thirty minutes after the administration of RGSF-A. The slow-relaxation had a tendency to be bigger than the fast-relaxation. Fast relaxation induced by RGSF-A was almost blocked by $N_{\omega}$-Nitro-L-arginine methyl ester (L-NAME), a nitric oxide synthase synthase inhibitor and 1H-[1,2,4]oxadiazolo[4,3-a]quinoxalin-1-one (ODQ), a guanylate cyclase inhibitor. However slow relaxation induced by RGSF-A was only partially inhibited by L-NAME and ODQ. In the endothelium-removed ring, RGSF-A evoked only slowrelaxation to a certain extent. These data suggest that RGSF-A induced both endothelium dependent fast- and slow-relaxation and endothelium independent slow-relaxation in the porcine distal LAD coronary artery. The endothelium dependent fast-relaxation is mediated by the nitric oxide (NO)-cGMP pathway, and the endothelium dependent slow-relaxation is at least partially mediated by the NO-cGMP pathway. However, the endothelium-independent slow-relaxation remains to be elucidated.

A Schottky Type Ultraviolet Photo-detector using RUO$_2$/GaN Contact (RUO$_2$/GaN 쇼트키 다이오드 형 자외선 수광소자)

  • Sin, Sang-Hun;Jeong, Byeong-Gwon;Bae, Seong-Beom;Lee, Yong-Hyeon;Lee, Jeong-Hui;Ham, Seong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.10
    • /
    • pp.671-677
    • /
    • 2001
  • A RuO$_2$ Schottky photo-detector was designed and fabricated with GaN layers on the sapphire substrate. For good absorption of UV light, an epitaxial structure with undoped GaN(0.5 ${\mu}{\textrm}{m}$)/n ̄-GaN(0.1${\mu}{\textrm}{m}$)/n+-GaN(1.5${\mu}{\textrm}{m}$) was grown by MOCVD. The structure had the carrier concentrations of 3.8$\times$10$^{18}$ cm ̄$^3$, the mobility of 283$\textrm{cm}^2$/V.s. After ECR etching process for mesa structure with the diameter of about 500${\mu}{\textrm}{m}$, Al ohmic contact was formed on GaN layer. After proper passivation between the contacts with Si$_3$/N$_4$, was formed on undoped GaN layer. The fabricated Schottky diode had a specific contact resistance of 1.15$\times$10$^{-5}$$\Omega$.$\textrm{cm}^2$]. It has a low leakage current of 305 pA at -5 V, which was attributed by stable characteristics of RuO$_2$ Schottky contact. In optical measurement, it showed the high UV to visible extinction ratio of 10$^{5}$ and very high responsivity of 0.23 A/W at the wavelength of 365nm.

  • PDF

A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type (하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.

Optimization of Culture Conditions and Encapsulation of Lactobacillus fermentum YL-3 for Probiotics (가금류 생균제 개발을 위한 Lactobacillus fermentum YL-3의 배양조건 최적화 및 캡슐화)

  • Kim, Kyong;Jang, Keum-Il;Kim, Chung-Ho;Kim, Kwang-Yup
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.255-262
    • /
    • 2002
  • This experiment was performed to improve the stability of Lactobacillus fermentum YL-3 as a poultry probiotics. The culture conditions that improve acid tolerance of L. fermentum YL-3 were investigated by changing several factors such as medium composition, temperature, anaerobic incubation and culture time. Also, L. fermentum YL-3 was encapsulated with alginate, calcium chloride and chitosan. The stable culture conditions of L. fermentum YL-3 were obtained in anaerobic incubation using MRS media without tween 80 for 20 hour at $42^{\circ}C$. The capsule after treatment with 1% chitosan was formed close membrane by a bridge bond. Immobilization of L. fermentum YL-3 in capsule was observed by confocal laser scanning microscopy, and cell viability was $2.0{\times}10^9\;CFU/g$ above the average. L. fermentum YL-3 capsule after acid treated at pH 2.0 for 3 hour survived about 40%, but those encapsulated with 1% chitosan survived about 65%. Survival rate of capsule stored at room temperature decreased about $2{\sim}3$ log cycle during 3 weeks, but viability of capsule stored at $4^{\circ}C$ during 3 weeks maintained almost $10^8\;CFU/g$ levels.