• 제목/요약/키워드: $^1H-\

검색결과 66,828건 처리시간 0.099초

Opening New Horizons with the L4 Mission: Vision and Plan

  • Kyung-Suk Cho;Junga Hwang;Jeong-Yeol Han;Seong-Hwan Choi;Sung-Hong Park;Eun-Kyung Lim;Rok-Soon Kim;Jungjoon Seough;Jong-Dae Sohn;Donguk Song;Jae-Young Kwak;Yukinaga Miyashita;Ji-Hye Baek;Jaejin Lee;Jinsung Lee;Kwangsun Ryu;Jongho Seon;Ho Jin;Sung-Jun Ye;Yong-Jae, Moon;Dae-Young Lee;Peter H. Yoon;Thiem Hoang;Veerle Sterken;Bhuwan Joshi;Chang-Han Lee;Jongjin Jang;Jae-Hwee Doh;Hwayeong Kim;Hyeon-Jeong Park;Natchimuthuk Gopalswamy;Talaat Elsayed;John Lee
    • 천문학회지
    • /
    • 제56권2호
    • /
    • pp.263-275
    • /
    • 2023
  • The Sun-Earth Lagrange point L4 is considered as one of the unique places where the solar activity and heliospheric environment can be observed in a continuous and comprehensive manner. The L4 mission affords a clear and wide-angle view of the Sun-Earth line for the study of the Sun-Earth and Sun-Moon connections from he perspective of remote-sensing observations. In-situ measurements of the solar radiation, solar wind, and heliospheric magnetic field are critical components necessary for monitoring and forecasting the radiation environment as it relates to the issue of safe human exploration of the Moon and Mars. A dust detector on the ram side of the spacecraft allows for an unprecedented detection of local dust and its interactions with the heliosphere. The purpose of the present paper is to emphasize the importance of L4 observations as well as to outline a strategy for the planned L4 mission with remote and in-situ payloads onboard a Korean spacecraft. It is expected that the Korean L4 mission can significantly contribute to improving the space weather forecasting capability by enhancing the understanding of heliosphere through comprehensive and coordinated observations of the heliosphere at multi-points with other existing or planned L1 and L5 missions.

맥락 인식 애플리케이션을 위한 사용자 중심의 맥락 모델 (User-centric Context Model for Context-aware Application)

  • 홍동표;우운택
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2007년도 춘계학술발표대회
    • /
    • pp.810-813
    • /
    • 2007
  • 본 논문에서는 맥락 인식 (context-aware) 애플리케이션 개발에 있어서 사용자의 맥락 정보를 보다 효과적으로 처리할 수 있는 사용자 중심의 맥락 모델을 제안한다. 유비쿼터스 컴퓨팅 개념의 확산과 함께 맥락 인식 애플리케이션들에 관한 많은 연구가 진행되고 있다. 하지만, 맥락에 대한 정의는 여전히 모호하며, 애플리케이션들 마다 서로 다른 형태의 맥락을 활용하고 있기 때문에, 맥락에 대한 보다 구체적인 정의와 다양한 애플리케이션에 활용 가능한 형태의 맥락 모델이 필요하다. 제안된 사용자 중심의 맥락 모델에서는 사용자가 애플리케이션과 상호작용할 때 사용자의 직접적인 명령을 제외한 사용자와 관련된 정보를 맥락으로 정의한다. 또한, 제안된 사용자 중심의 맥락은 5W1H 형태로 구조화한 맥락요소 (ContextElement), 맥락 요소들을 편리하게 처리할 수 있는 연산자들을 포함하는 맥락 (Context), 그리고 단편적인 맥락 정보뿐만 아니라 기존의 맥락 정보까지도 활용할 수 있는 맥락메모리 (ContextMemory)로 구성된다. 특히, 다양한 센서들로부터 획득된 정보를 맥락 모델의 인터페이스를 통해서 맥락 인식 애플리케이션에서 활용할 수 있기 때문에, 서로 다른 맥락 인식 애플리케이션들을 개발함에 있어서도 동일한 맥락 모델을 사용할 수 있는 장점이 있다. 제안된 맥락 모델의 유용함을 보이기 위해서, 센서로부터 획득된 맥락 정보를 처리하는데 소요되는 시간을 측정하는 실험을 하였다. 따라서 제안된 사용자 중심의 맥락 모델은 사용자와 맥락 인식 애플리케이션간 자연스러운 상호작용을 지원할 것으로 기대된다.) kcal/mol의 생성활성화 에너지 감을 나타내었고, TGA로부터의 분해활성화 에너지는 각각 31.94, 30.84, 24.16 kcal/mol의 값을 나타내었다.로 감소되었다(35.2% vs. 77.4%; p<0.01). 실험 2에서 다양한 정자 농도에 의한 정자 침투율과 정상 수정률을 바탕으로 판단했을 때 $4.6{\times}10^6/ml$의 정자 농도가 다른 정자 농도에 비해 난구 세포부착 난자의 체외 수정에 적합한 것으로 나타났다. 체외 수정과정에서 난구 세포 부착된 상태로 수정된 난자는 나화 난자에 비해 유의적으로(p<0.05) 높은 분할률(48.8% vs. 58.9%), 배반포 형성률(11.0% vs. 22.8%)과 배반포 세포수$(22{\pm}2\;vs.\;29{\pm}2)$를 나타내었다. 본 연구의 결과로부터 돼지의 체외 수정과정에서 난구 세포의 존재는 정자 침투를 저해하지만 분할률, 배반포 형성률 및 배반포의 세포수를 증가시키는 것으로 사료된다.수의 유출입 지점에 온도센서를 부착하여 냉각수의 온도를 측정하고 냉각수의 공급량과 대기의 온도 등을 측정하여 대사열의 발생을 추정할 수 있었다. 동시에 이를 이용하여 유가배양시 기질을 공급하는 공정변수로 사용하였다 [8]. 생물학적인 폐수처리장치인 활성 슬러지법에서 미생물의 활성을 측정하는 방법은 아직 그다지 개발되어있지 않다. 본 연구에서는 슬러지의 주 구성원이 미생물인 점에 착안하여 침전시 슬러지층과 상등액의 온도차를 측정하여 대사열량의 발생량을 측정하고 슬러지의 활성을 측정할 수 있는 방법을 개발하였다.enin과

Object Detection Performance Analysis between On-GPU and On-Board Analysis for Military Domain Images

  • Du-Hwan Hur;Dae-Hyeon Park;Deok-Woong Kim;Jae-Yong Baek;Jun-Hyeong Bak;Seung-Hwan Bae
    • 한국컴퓨터정보학회논문지
    • /
    • 제29권8호
    • /
    • pp.157-164
    • /
    • 2024
  • 본 논문에서는 제한된 자원을 가진 보드에서 딥러닝 기반 검출기 구축에 대한 실현 가능성에 대해 논의한다. 많은 연구에서 고성능 GPU 환경에서 검출기를 평가하지만, 제한된 연산 자원을 가진 보드에서의 평가는 여전히 미비하다. 따라서 본 연구에서는 검출기를 파싱하고 최적화하는 것으로 보드에 딥러닝 기반 검출기를 구현하고 구축한다. 제한된 자원에서의 딥러닝 기반 검출기의 성능을 확인하기 위해, 여러 검출기를 다양한 하드웨어 자원에서 모니터링하고, COCO 검출 데이터 셋에서 On-Board에서의 검출 모델과 On-GPU의 검출 모델을 mAP, 전력 소모량, 실행 속도(FPS) 관점으로 비교 및 분석한다. 그리고 군사 분야에 검출기를 적용한 효과를 고려하기 위해 항공 전투 시나리오를 고려할 수 있는 열화상 이미지로 구성된 자체 데이터 셋에서 검출기를 평가한다. 결과적으로 우리는 본 연구를 통해 On-Board에서 모델을 실행하는 딥러닝 기반 검출기의 강점을 조사하고, 전장 상황에서 딥러닝 기반 검출기가 기여할 수 있음을 보인다.

골판지 포장지의 알루미늄 코팅이 팽이버섯의 저온저장 중 품질 특성에 미치는 영향 (The effect of aluminum coating to corrugated packaging on quality characteristics of Enoki mushrooms (Flammulina velutipes) during storage)

  • 김아나;이교연;박채은;김세리;최송이;황인준;박경민;최성길
    • 한국식품저장유통학회지
    • /
    • 제31권4호
    • /
    • pp.612-622
    • /
    • 2024
  • 팽이버섯은 다양한 영양성분이 함유되어 있어 우수한 식품 소재로 알려져 있지만, 높은 수분함량 및 높은 호흡량으로 인해 심한 갈변과 부패로 유통기간이 짧아 저장유통 중 품질보존을 위한 연구가 필요한 실정이다. 따라서 본 연구에서는 농산물 유통 시 주로 사용되는 골판지상자의 내부에 알루미늄을 코팅하여 기능성을 부여한 포장용기를 개발하였으며, 이를 이용하여 팽이버섯을 포장하여 저장 중 선도 유지 및 품질특성에 미치는 영향을 조사하였다. 골판지상자 내부에 알루미늄을 코팅함으로써 중량변화율 및 경도의 감소를 방지하였으며, pH의 변화를 억제하는 것으로 나타났다. 또한, 산화효소 활성을 억제함으로써 저장기간 중 팽이버섯의 갈변을 저해하였고, 미생물의 증식을 억제하는데 효과적인 것으로 나타났다. 향후 관능적 품질, 포장지 내부의 기체 조성과 향기 성분에 대한 추가연구를 통하여 Shelf-life 연장효과를 종합적으로 규명하는 것이 필요할 것으로 판단된다.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

알레르기 비염에 관한 임상적 연구 (A clinical study of allergic rhinitis)

  • 채병윤
    • 대한한의학회지
    • /
    • 제21권3호
    • /
    • pp.149-165
    • /
    • 2000
  • As recent developments of Immunology and Nuclear medicine, serum IgE and IgG values are helpful in the diagnosis and evaluation of the therapeutic effects of nasal allergies. But in Korea, air pollution and the increased use of food additives have become leading factors in nasal allergies, It seems to be induced by environmental change, especially industrialization and urbanization, so allergic rhinitis in our environment has changed in accordance with the changes made in the living environment. Therefore this study is attempted in order to observe a clinical analysis which places more importance on allergic rhinitis. We studied 200 patients who had visited Kyunghee Oriental Medical Center with allergic rhinitis from January 1, 1999 to December 31, 1999 The results were as follows: 1. The sex distribution was 114 males(57%) and 86 females(43%). In age distribution, the average age was 25. In males, ages ranged from 3 to 66 years old and the average was 23.81. In females, ages ranged from 4 to 67 years old and the average was 28.57. The peak age was 30~39 years old(24%); under 9 years old and 10~19 years old were each 18%; 20~29 years old was 22%; 40~49 years old was 11 %; over 50 years old 6.5%. The gulf between males and females showed a statistically significant difference(P<0.025). 2. In the age of onset, male' s maximum was 62.5, minimum was 0.25; female s maximum was 59.5, minimum was 0.2. Under 9 years old was the most with 34%(male 24%, female 10%), 10~19 years old was 18%, 20~29 years old was 22.5%, 30~39 years old was 13.50%, over 40 years old was 12%, The gulf between males and females were showed statistically significant difference.(p<0.014) 3. The average duration of the disease was 5.67 years. In male and female, the maximum was 30, the minimum was 0.05; under 5 years old was the most with 62%(male 34.50%, female 27.50%); 6~10 years old was 23%. So, under 10 years old was 85%. There was no statistically significant difference in the duration of disease. 4. Regarding type of residence, 47.50% of patients with allergic rhinitis lived in apartments, 52.50% lived in houses. In males, 29.50% lived in apartments, 27.50% lived in houses. In females, 18% lived in apartments, 25% lived in houses. There was no statistically significant difference in the residence by T-test and chi-test. 5. In the distribution of season, spring is the most with 29.5% of patients, winter 28%, fall 25.5%, and summer 17%. But there was no statistically significant difference. 6. After observing 200 patients with allergic rhinitis, classifying main symptoms into 5 types, sneezing was the main symptom in 177cases(88.50%), nasal obstruction in 176cases(88%), rhinorrhea in 169cases(84.5%), post nasal discharge in 87cases(43.50%), and itching in I04cases(52%). The Cumulus ration is 98.50% and symptoms overlapped with an average 3.57±0.1 times but in an analysis of variance of these symptoms, the gulf between males and females was not recognized as statistically significant by T-test and ANOVA. 7. Patients whose families have allergic diseases account for 90 cases(45%) : 49cases(24.50%) male and 41cases(20.50%) female. There were 4 cases (71.11 %) whose families have allergic rhinitis, 9cases(10%) of asthma, and 7.78% with allergic dermatitis. There were 61 (67.80%) cases of patients whose parents have allergic diseases; cases wherein the patient s child had allergic diseases numbered 13 (14.45%); and cases with a sibling with allergic diseases totalled 16cases (17.80%). There was no statistically significant difference in allergic disease regarding sex, parents, or siblings by chi-test. 8. Blood type: For males, type A is the most common, with 37cases(18.5%), followed by type B with 32cases(16%), type O 28cases(l4%) and type AB 13cases(6.5%). For females, type B is the most common, with 30cases(15%), followed by type O with 23cases(l1.5%), type A with 18cases(9%) and type AB with 13cases(6.5%). There was no statistically significant difference in blood type by chi-test. 9. In the selection of prefered food, most patients prefer cool food, with 98 such cases(49%), tepid food in 54cases(27%) and warm food in 48cases(24%). These showed a statistically significant difference in the selection of prefered food between males and females by chi-test(p<0.009). 10. The state of Past History was classified into II types. chronic hypertrophic rhinitis is the most common with 11cases (18.64%), tonsil and adenoid hypertrophy is 8cases(l3.56%), sinusitis is 6cases(10.17%), nasal septum deviation is 4cases, nasal polyp is 2cases, others are 10cases(l6.95%). No statistically significant difference in past history between males and females was shown, but a statistically significant difference was shown when males and females were compared with total cases by T-test(p<0.002, P<0.0008). 11. Regarding complications, 37 patients (28.91%) had sinusitis: 22cases(17.19%) in male, 15cases(11.72%) in female. Chronic hypertrophic rhinitis was found in 15cases(11.72%). Others are under 10%. There was no statistically significant difference in the type of complications between males and females, but a statistically significant difference was shown when males and females were compared with total cases by T-test(P<0.00l, P<0.007). 12. In the treatment, medication was used 1691 times, an average of 2.58 times. No.34 was used 370 times for 124 cases, an average of 2.98 times. No. 152 was used 318 times for 106 cases, an average of 3.00 times. No.151 was used 307 times for 97cases, an average of 3.16 times. No. 31 was used 117 times for 33 cases, an average of 3.55 times. No 25 was used 116 times for 33 cases, an average of 3.52 times. 13. In the duration of treatment, the most frequent is 1 week(69cases, 34.50%), the maximum is 20weeks, and the minimum is 1week. A treatment period of 2~3 weeks accounted for 32% of cases, a period of 4~5weeks accounted for 13.5%. The gulf between males and females showed a statistically significant difference in the duration of treatment.(p<0.01). There was a statistical significance when the males were compared with total cases by ANOVA(P<0.03). 14. A comparison between before-treatment and after-treatment showed a statistically significant difference in treatment by T-test (p<0.01) and F-test (p<0.0058).

  • PDF

호밀의 사초특성, 수량 및 품질에 미치는 파종량 및 파종기의 영향 (Seeding Rate and Planting Date Effects on Forage Performance and Quality of Winter Rye)

  • 박형수;김동암;김종덕
    • 한국초지조사료학회지
    • /
    • 제19권2호
    • /
    • pp.105-114
    • /
    • 1999
  • 본 시험은 파종량 및 파종시기가 추파 호밀(Secale cereale L.)의 사초특성, 수량 및 사료가치에 어떠한 영향을 미치는가를 알아보기 위하여 1997년에서 1998년 4월 20일까지 서울대학교 농업생명과학대학 부속 실험목장 사초 시험 포장에서 실시되었으며, 파종량으로서 ha 당 100, 150 및 200kg을 주구로 하고 파종시기로서 9월 5일, 9월 20일, 10월 5일 및 10월 20일 파종을 세구로 하는 분할구 시험법으로 3반복 설계 배치하였으며, 결과를 요약하면 다음과 같다. 호밀의 출수 시작일은 파종기에 따라서 뚜렷한 영향을 받지 않는 것으로 나타났다. 하지만 1일 기준으로, 파종시기가 15일 지연됨에 따라 출수 시작일이 1일 지연되어짐으로서 호밀의 출수시작일과 파종시기간에는 1:15 비율이 나타났다. 호밀의 건물 함량은 파종량간에는 200 kg/ha 파종구에서 13.6%로 가장 낮게 나타났다. 파종시기간에는 각각 15.2, 14.2, 14.3 및 13.8%로 파종시기가 지연됨에 따라 건물 함량이 낮아졌으며 (P<0.05), 호밀의 건물 함량에 대하여 파종량과 파종시기간에는 고도의 교호작용(P<0.01)이 인정되었다. 호밀의 ADF 함량은 파종량간에 유의적인 차이가 없었으나 파종시기간에는 각각 32.2, 31.6, 31.6 및 29.3%로 파종시기가 늦어짐에 따라 함량이 낮아졌으며, 파종량과 파종시기간에는 교호작용이 인정되었다. 또한 NDF 함량도 ADF 함량과 비슷한 경향을 보였다. 조단백질(CP) 함량은 파종량간에는 차이가 없었으나 파종시기가 늦어짐에 따라서 각각 17.3, 17.7, 18.2 및 18.9%로 증가하였다. In vitro 건물소화율(IVDMD)도 파종량간에는 차이가 없었으나 파종시기가 늦어짐에 따라서 각각 77.5, 80.6, 80.9 및 80.9%로 증가하였다. 호밀의 건물수량은 100 kg/ha 파종구가 9,059 kg/ha로 가장 높았고 200kg/ha 파종구가 7,647 kg/ha로 가장 낮았다(P<0.01). 파종시기간에는 10월 5일 파종구(8,945 kg/ha)가 가장 높게 나타났으며 10월 20일 파종구(7,249 kg/ha)에서 가장 낮게 나타났다(P<0.01). 또한 호밀의 건물 수량에 대하여 파종량과 파종시기간에는 유의적인 교호작용이 인정되었다(P<0.01). CP 및 IVDDM 수량도 건물 수량과 비슷한 경향을 보였다. 본 시험의 결과를 종합하면 우리 나라 중부지방에서 사초용 호밀을 재배시 건물 수량의 증수를 위해서 파종은 9월 20일에서부터 10월 5일 사이에 하는 것이 가장 유리하며 조기 파종할 경우 100~150kg/ha, 만기 파종할 경우는 200 kg/ha로 파종량을 증가시키는 것이 바람직하다고 생각된다.

  • PDF

하천고수부지 수질정화 여과습지의 초기운영단계 질소제거 (Nitrogen Removal Rate of A Subsurface Flow Treatment Wetland System Constructed on Floodplain During Its Initial Operating Stage)

  • 양홍모
    • 한국환경농학회지
    • /
    • 제22권4호
    • /
    • pp.278-283
    • /
    • 2003
  • 본 연구는 고수부지에 조성한 여과습지의 초기운영단계 질소제거율을 분석하였다. 조사기간 처리수의 평균수온은 $17.1^{\circ}C$이었고, 평균 pH는 7.1이었으며, 갈대의 평균 N흡수량은 $69.31\;N\;mg/m^2/day$였다. 유입수와 유출수의 평균 $NO_3-N$ 농도는 각각 3.46, 2.23 mg/L이었으며, 여과습지의 $NO_3-N$ 평균제거율은 $195.58\;mg/m^2/day$였다. 유입수와 유출수의 평균 $NH_3-N$ 농도는 각각 0.92, 0.58 mg/L이었으며, $NH_3-N$ 평균 제거율은 $53.65\;mg/m^2/day$를 보였다. 유입수와 유출수의 평균 T-N 농도는 각각 10.24, 6.32 mg/L 였으며, T-N 평균제거율은 $628.44\;mg/m^2/day$를 보였으며, 제거량 기준으로 T-N 평균제거율은 약 39%를 나타냈다. 시스템이 초기 운영단계인 점을 고려하면 T-N제거 수준은 비교적 양호한 편이다. 여과습지의 $7{\sim}10$월의 수온이 암모니아화, 질산화, 탈질화에 비교적 적합한 온도를 유지하였고, 매질사이의 공극에 입자성 유기태 질소가 고정되고, 매질표면에 형성된 미생물막에 유기태 질소가 흡착되어 분해되고, 유입수가 원활히 시스템을 흐른 것이 질소제거의 주요 원인으로 사료된다. $2{\sim}3$년 후 갈대가 정상적으로 성장하여 뿌리와 근권이 발달하고, 갈대의 잔재물로부터 유기쇄설물이 형성되어 탈질화에 필요한 탄소공급원이 제공되면, 시스템의 질소 처리율이 높아질 것으로 생각된다. 실험결과 고수부지를 활용한 수질정화 여과습지는 오염하천수에 함유된 질소를 줄일 수 있는 방안이 될 수 있을 것으로 사료된다.PL특성은 상온에서도 눈으로 보일 만큼 우수한 발광 특성을 보였으며, 기판 bias전압이 증 가함에 따라 PL peak 위치가 청색으로 편이하는 경향을 보였다. 이러한 발광 세기의 변화 는 $V_s$=0V부터 $V_s$=200V까지는 기판의 bias전압이 증가함에 따라 상대적으로 박막의 표면에 충돌하는 이온에너지의 감소로 인해 a-C:H박막내에 비발광 중심으로 작용하는 dangling bond가 감소하여 발광의 세기가 증가하였으며 $V_s$=300V이상에서는 박막내의 수소 함유량이 증가함에 따라 dangling bond수는 감소하나 발광 중심으로 작용하는 탄소간의 $\pi$결합을 포 함하는 cluster가 줄어들어 PL세기가 감소한 것으로 생각된다.1례, 폐동 맥: 1례)이 4례, 2주 이상의 지속적 흉관배액이 4례, 유미흉이 3례, 출혈에 의한 재수술이 3례, 기타 급성 신 부전, 종격동염, 횡경막신경 마비가 각각 2례씩 있었으며, 중복치환술을 받은 환자들과 전통적 술식으로 수 술받은 환자에서 술후 합병증의 차이는 없었다. 65명의 환자를 평균 54$\pm$49개월(0~177개월)간 추적관찰하였 으며, 수술 초기에 사망한 환자는 13명으로 20.0%(13/65)의 수술사망율을 보였으며 3명의 환자가 추적기간중 사망하여 24.6%(16/65)의 전체사망율을 보였다. 중복치환술을 받은 환자의 수술사망율은 33.3%(4/12)였다. 술 후 1년, 5년, 10년 누적생존율은 각각 75.0$\pm$5.6%, 75.0$\pm$5.6%, 69.2$\pm$7.6%였다. 가장 흔한 사망원인으로는 술 후 저심박출증후군으로 8례였으며 삼첨판막 폐쇄부전이 심해져 심부전으로 사망한 경우도 5례로 사망의 중 요 원인이었다. 결론 저자들은 본 연구를

생쥐에서 과립구 집락형성인자(Granulocyte-Colony Stimulating Factor)의 공장점막에 대한 방사선 보호효과 (Radioprotective Effects of Granulocyte-Colony Stimulating Factor in the Jejunal Mucosa of Mouse)

  • 유미령;정수미;계철승;김연실;윤세철
    • Radiation Oncology Journal
    • /
    • 제19권1호
    • /
    • pp.45-52
    • /
    • 2001
  • 목적 : 최근 항암 화학요법이나 두경부의 방사선치료 후 나타나는 백혈구감소증을 치료하기 위해 조혈세포 성장인자인 과립구 집락형성인자를 투여한 결과, 백혈군감소증과 더불어 구강 점막염의 완화가 몇몇 임상연구에서 보고되고 있다. 그러나 그 기전이나 적절한 투여 방법에 대해서는 뚜렷이 밝혀지지 않았으며, 다른 위장관 점막에 대한 보호효과에 대해서도 아직 알려진 바가 없다. 이에 저자는 생쥐 공장 점막에 대한 과립구 집락형성인자의 방사선 보호제로서의 가능성을 알아보고자 하였다. 대상 및 방법 : 실험 동물은 체중 20 g 내외의 생후 $4\~5$주된 BALB/c 생쥐 105 마리로 각각 정상 대조군, 과립구 집락형성인자 단독투여군(제 I 군 : $10\;{\mu}g/kg/$일, 제 II 군 $100\;{\mu}g/kg/$일), 방사선 단독조사군(7.5 Gy 또는 12 Gy 전신조사), 그리고 방사선조사와 과립구 집락형성인자 병행 처치군(G-CSF I 또는 II+7.5 Gy, G-CSF I 또는 II+12 Gy)의 아홉군으로 구분하였다. 과립구 집락형성인자는 과립구 집락형성인자 단독투여군 및 방사선조사와 과립구 집락 형성인자 병행처치군 모두에서 방사선조사 2일 전부터 24시간 간격으로 방사선조사일까지 3일 동안 매일 1회 피하 주사하였고, 방사선조사는 6 MV 선형 가속기를 이용하여 7.5 Gy와 12 Gy를 각 군별로 1회 전신조사하였다. 각 군별로 생쥐를 방사선조사 후 1, 3, 7일에 희생하여 공장을 적출하고 H&E 염색 및 PAS 염색을 시행한 후, 공장 조직 표본에서 소낭선의 수, 융모의 길이 및 조직학적 손상등급을 측정하고 조직학적 변화를 관찰하였다. 결과 : 방사선조사없이 과립구 집락형성인자 만을 투여한 군(제 I 군 : $10\;{\mu}g/kg/$ 및 제 II 군: $100\;{\mu}g/kg/$) 에서는 정상 대조군에 비해 생쥐 공장 점막 변화에 유의한 차이가 없었다(p>0.05). 7.5 Gy 및 12 Gy 방사선 단독조사군에서는 정상 대조군에 비해 공장 점막의 소낭선 수의 감소와 높은 조직학적 손상등급을 관찰하였다(p<0.05). 12 Gy 방사선조사와 과립구 집락형성인자 병행처치군에서는 공장 점막의 손상이 7.5 Gy 방사선 단독조사군에 비해 1일 군에서는 차이가 없었으나(p>0.05), 3일 군에서 유의하게 높은 소낭선 수 및 낮은 조직학적 손상등급을 관찰하였고, 7일 군에서 낮은 조직학적 손상등급을 관찰하였다(p<0.05). 12 Gy 방사선조사와 과립구 집락형성인자 병행처치군에서의 공장 점막 손상은 12 Gy 방사선 단독조사군에 비해 소낭선의 수와 융모의 길이, 조직학적 손상등급의 차이가 유의하지 않았으며(p>0.05), 두 마리를 제외한 대부분의 생쥐가 방사선조사 후 5일 이내에 모두 사망하였다. 결론 : 한계 선량 이내의 전신 방사선조사시 과립구 집락형성인자는 생쥐의 공장 점막에 대한 방사선보호작용이 있는 것으로 사료된다.

  • PDF

단백질분해세균(蛋白質分解細菌)을 병용(倂用)한 간장제조(製造)에 관(關)한 연구(硏究) (A Study on the Manufacturing of Soysauce by the Combined use of Aspergillus sojae and Bacillus subtilis)

  • 김재욱;조성환
    • Applied Biological Chemistry
    • /
    • 제18권1호
    • /
    • pp.1-9
    • /
    • 1975
  • Aspergillus sojae를 사용(使用)하여 제조(製造)한 Koji와 Bacillus subtilis를 사용(使用)하여, 제조(製造)한 Natto의 배합비(配合比)를 달리하여, 그 효소역가(酵素力價)를 검토(檢討)하고 Koji와 Natto의 配合比를 10 : 0, 8 : 2, 6 : 4, 4 : 6, 2 : 8, 0 : 10으로 하여 담근 간장을 3개월간(個月間) 숙성(熟成)시키면서 숙성기간중(熟成期間中)의 화학성분변화(化學成分變化)를 조사(調査)하고 3개월간(個月間) 숙성(熟成)시킨 간장덧액(液)에 대하여 식미시험(食味試驗)을 행(行)하여 다음과 같은 결과(結果)를 얻었다. 1. Koji 제조중(製造中)의 pretense activity는 시간(時間)이 경과(經過)함에 따라 꾸준한 증가(增加)를 보여 60 시간(時間)에 가서 44 tyrosine ${\mu}g$/ml 인데 비(比)해 Natto 제조중(製造中)의 pretense activity는 급격(急激)한 증가(增加)를 보며 배양(培養) 15시간(時間)만에 이미 46 tyrosine ${\mu}g$/ml 였으며, 30시간(時間)배양(培養)으로 99 tyrosine ${\mu}g$/ml 에 이르렀다. 한편, amylase activity는 Natto 제조중(製造中) 시간(時間)이 경과(經過)함에 따라 약간(若干)의 증가(增加)를 보였으나 Koji 제조중(製造中)에는 30시간경(時間頃)까지 급격(急激)한 증가(增加)를 보이고 그 이후(以後) 비교적(比較的) 완만(緩慢)하게 증가(增加)하였으나 전기간(全期間)을 통(通)하여 Natto 에 비(比)하여 월등(越等)히 높았다. 2. Koji와 Natto를 일정(一定)한 비(比)로 배합(配合)하했을 때 pretense activity Natto의 배합량(配合量)이 많을수록 점차(漸次) 높았고 amylase activity는 Koji의 배합량(配合量)이 많을수록 높아졌다. 3. 총질소(總窒素)는 모든 시험구(試驗區)에서 숙성(熟成) 2개월경(個月頃)까지 급격(急激)한 증가(增加)를 보이다가, 그 이후(以後) 거의 일정치(一定値)를 유지(維持)하였으며 Natto 배합비(配合比)가 많은 시험구(試驗區)일수록 높은 값을 보이면서 증가(增加)하였다. 4. amino 태질소(態窒素)는 전구(全區)가 다같이 숙성기간(熟成期間)이 경과(經過)함에 따라 대체(大體)로 증가(增加)되였는 데 그 함량(含量)은 Natto의 배합량(配合量)이 많은 구(區)일수록 높은 값을 나타냈다. 5. ammonia태질소(態窒素)는 Koji단용구(單用區) 및 Koji와 Natto, 의 배합비(配合比)가 8 : 2인 구(區)는 숙성기간(熟成期間)이 경과(經過)함에 따라 계속 대체(大體)로 완만(緩慢)한 증가(增加)를 보였으나 Natto단용구(單用區) 및 Koji와 Natto의 배합비(配合比)가 6 : 4, 4 : 6, 2 : 8인 구(區)는 숙성(熟成) 1$\sim$2 개월(個月)까지는 급격(急激)히 증가(增加)하였다가 그 이후(以後)는 감소(減少)되였는데 전반적(全般的)으로 Natto의 배합비(配合比)가 많을수록 높은 함량(含量)을 보였다. 6. 환원당(還元糖)은 모든 구(區)가 숙성(熟成) 2개월(個月)까지 대체(大體)로 현저(顯著)하게 증가(增加)되였으나 그이후(以後)는 감소(減少)되였는데 저구(全區) 다같이 환원당(還元糖)의 함량(含量)은 Koji의 배합비(配合比)가 많을수록 높았다. 7. 총산(總酸)은 Koji 단용구(單用區) 및 Koji와 Natto의 배합비(配合比)가 8 : 2인 구(區)는 숙성기일(熟成期日)이 지남에 따라 계속 증가(增加)되였으나 Natto의 배합량(配合量)이 비교적(比較的) 많은 구(區)일수록 숙성(熟成) 50$\sim$70일경(頃)까지 급격(急激)한 증가(增加)를 보이다가 그 이후(以後)는 감소(減少)하였다. pH는 전구(全區) 다같이 숙성(熟成) 50일(日)까지 저하(低下)되었다가 그이후(以後) 큰 변화(變化)가 없었다. 8. 3개월(個月) 숙성(熟成)시킨 간장에 대(對)한 관능시험결과(官能試驗結果)는 Koji와 Natto의 배합비(配合比)가 6 : 4일때 기호도(嗜好度)가 가장 높았고 이들 배합비(配合比)가 8 : 2, 10 : 0, 4 : 6, 2 : 8, 0 : 10의 순서(順序)로 낮았으며 Natto를 일정량(一定豊) 배합(配合)한것이 Koji단용구(單用區)와 Natto단용구(單用區)보다 우수(優秀)함을 알수 있었다.

  • PDF