• Title/Summary/Keyword: $^{99m}Tc-DMSA$ scan

Search Result 62, Processing Time 0.023 seconds

Discrepancy and Correlation in the renal length between Kidney CT and 99mTc-DMSA Renal scan (신장 CT 검사와 99mTc-DMSA Renal Scan 검사에서 측정한 신장 길이의 차이 및 상관분석)

  • Jung, Woo-Young;Shim, Dong-Oh;Lee, Dong-Hun;Choi, Jae-Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.1
    • /
    • pp.15-20
    • /
    • 2021
  • Purpose This article studies the relationship between the length of a kidney measured by two scanning methods: Kidney Computed Tomography (CT) and 99mTc-Dimercaptosuccinic acid (DMSA) renal scan. Kidney CT provides a better anatomic assessment, while 99mTc-DMSA renal scan is superior in the kidney function test. Materials and Methods From January to December of 2019, two hundred patients who had Kidney CT and Tc99m-DMSA renal scan were chosen for this study. SPSS17.0 was selected for statistical analysis. Results Due to the effect of the breathing and resolution of 99mTc-DMSA renal scan, it showed the kidney's relatively longer length than the length of Kidney CT. For the same kidney, the length comparison among different brands' Gamma cameras was negligible. The length difference within the same age group did not show a noticeable discrepancy. However, there was a length difference between the radio technologists. Kidney CT and 99mTc-DMSA renal scan indicated a strong positive correlation between the length of the left and right kidney. Conclusion It is necessary to establish a standardized measurement method for measuring kidney length using 99mTc-DMSA renal scan. The kidney's functional changes and length changes are indications of Kidney diseases. Especially, pediatric patients tend to use 99mTc-DMSA renal scan for assessing the kidney's shape and the function to avoid potential radiation exposure during the Kidney CT. Therefore, it is significant to provide not only the kidney's functional information but also an anatomic analysis, including the kidney's size, length, and location through the 99mTc-DMSA renal scan.

Clinical Significances of $^{99m}TC-DMSA$ Renal Scan in Patients with Acute Pyelonephritis (급성신우신염에서 $^{99m}TC-DMSA$ 신장스캔의 임상적 의의)

  • Mok, Cha-Soo;Shin, Dong-Jin;Choi, Ho-Cheon;Kim, Gyeong-Wook;Yi, Gang-Wook;Choi, Dae-Seop
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.201-207
    • /
    • 1989
  • Patients with acute pyleonephritis may present with a spectrum of clinical symptoms and signs. There are few noninvasive diagnostic studies, however, to confirm or exclude this diagnosis. To evaluate the clinical utility of $^{99m}Tc-DMSA$ renal scan in diagnosis of acute pyelonephritis, we performed $^{99m}Tc-DMSA$ renal scan in 37 patients suspected with urinary tract infection. Simultaneously, kidney ultrasonography was done in 21 patients diagnosed with acute pyelonephritis, clinically. And we performed the followup scan after treatment in two to six weeks. The results were as follows: 1) $^{99m}Tc-DMSA$ renal scan disclosed single or multiple cortical defects and decreased radiouptake ratio of affected kidney in 23 patients among 25 patients diagnosed with acute pyleonephritis. 2) In the 21 patients with acute pyelonephritis, kidney ultrasonography showed abnormal finding in the 7 patients. And $^{99m}Tc-DMSA$ renal scan disclosed abnormal cortical defects in this 7 patients also. 3) Between the patients with acute pyelonephritis and those with lower urinary tract infection, asymptomatic bacteriuria or pyuria. right-to-left radiouptake ratios (R/L ratio) were significantly different (p < 0.001). 4) In two to six weeks after antibiotic therapy, we performed followup $^{99m}Tc-DMSA$ renal scan for 5 patients among 25 acute pyelonephritis patients. And we have found the improvement of cortical defects and the right-to-left radiouptake ratio. In conclusion, we thought that $^{99m}Tc-DMSA$ renal scan should be useful in diagnosis of acute pyelonephritis and follow-up examination.

  • PDF

Tc-99m DTPA and Tc-99m DMSA Renal Scan findings in Patients with Congenital Megacalyces and Megaureter without Urinary Tract Obstruction (선천성 거대신배증과 거대뇨관증을 가지나 요로폐쇄가 없는 환아의 Tc-99m DPTA 및 Tc-99m DMSA 신장스캔 소견)

  • Ahn, Byeong-Cheol;Bae, Jin-Ho;Jeong, Sin-Young;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.3
    • /
    • pp.202-205
    • /
    • 2003
  • A 10 days old male infant with congenital megacalyces and megaureter, diagnosed by prenatal ultrasonographic screening, underwent Tc-99m DTPA renal scan for evaluation of urinary tract patency, Tc-99m DMSA scan for evaluation of renal cortical damage. He also underwent intravenous urography(IVU) and renal ultrasonography. Tc-99m DTPA renal scan demonstrates intense tracer accumulation in enlarged both renal pelvocalyses and ureters, which rapidly washout without diuretics administration. Tc-99m DMSA renal cortical scan shows no remarkable photon defect in both renal cortices and visible tracer uptake in both megaureter areas. Ultasonographic and IVU studios show enlarged both renal calyses and bullously dilated ureters, but no dilatation in renal pelvis. Follow up Tc-99m DTPA renal scan, peformed at one year later, also reveals intense tracer accumulation in enlarged both urinary tracts which rapidly washout without diuretics, and shows no significant change compare to the previous Tc-99m DTPA renal scan. Urinary tract obstruction and renal cortical damage can be easily evaluated with Tc-99m DTPA and Tc-99m DMSA scans in patiens with megacalyces and megaureter.

Recurrent Malignant Thymoma Detected by Tc-99m MIBI, Tc-99m Tetrofosmin and Tc-99m (V) DMSA Scan (Tc-99m MIBI, Tc-99m Tetrofosmin, 그리고 Tc-99m (V) DMSA 스캔에 의해 발견된 재발성 악성 흉선종)

  • Seok, Ju-Won;Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.4
    • /
    • pp.268-273
    • /
    • 2001
  • Thymoma is the most common primary tumor of anterior mediastinum, accounting for 20% to 30% of all mediastinal tumors. The recurrence rate after total resection of the thymoma ranges 8% to 18%. We reported one patient of recurrent malignant thymoma imaged with Tc-99m MIBI, Tc-99m Tetrofosmin and Tc-99m (V) DMSA. Early and delayed Tc-99m MIBI and Tc-99m Tetrofosmin scintigraphies showed an increased uptake in the mediastinal area. Also, Tc-99m (V) DMSA scintigraphy revealed an increased uptake tn the corresponding area. Coronal SPECT images of Tc-99m MIBI, Tc-99m Tetrofosmin and Tc-99m (V) DMSA revealed increased uptake of each radiopharmaceutical in the tumor lesion corresponding to the mediastinal lesion on the chest CT. However, the normal blood pool activities of the heart and great vessels of Tc-99m (V) DMSA obscured the recurrent malignant thymoma. Although Tc-99m (V) DMSA is a useful tumor seeking agent, we recommend Tc-99m MIBI and Tc-99m Tetrofosmin SPECT rather than Tc-99m (V) DMSA to detect primary and recurrent malignant thymoma.

  • PDF

Voiding cystourethrography in children with an initial episode of febrile urinary tract infection (생후 처음으로 발생한 발열성 요로감염 환자의 배뇨성 방광 요도 조영술)

  • Lee, Hae Jeong;Lee, Won Deok;Kim, Hyun Seok;Kim, Tae Hong;Lee, Joo Seok;Cho, Kyung Lae
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.6
    • /
    • pp.653-658
    • /
    • 2006
  • Purpose : Because voiding cystourethrography(VCUG) is an invasive method, we studied whether VCUG could be postponed through evaluation of alternative non-invasive tests including renal ultrasonography and $^{99m}Tc$-DMSA renal scan. Methods : We reviewed the medical records of 175 patients initially diagnosed with febrile urinary tract infection during the one year period of 1999, and compared 3-tests : renal ultrasongraphy, $^{99m}Tc$-DMSA renal scan, and VCUG. Results : Renal ultrasonography didn't contribute to the prognostication of pyelonephritis(photopenic areas) or vesicoureteral reflux(VUR). Presentation of photopenic areas in $^{99m}Tc$-DMSA renal scan was related to VUR. If both findings of renal ultrasonography and $^{99m}Tc$-DMSA renal scans were normal, this condition was closely related to normal results in VCUG. And if both examinations were abnormal, the condition was closely related to VUR. But this state could not always guarantee the normal result from VCUG because of low sensitivity in finding VUR. Conclusion : In cases in which acute phyelonephritis is demonstrated by $^{99m}Tc$-DMSA renal scan, VCUG is required. In addition to this, if the conditions of hydronephrosis, vesicoureteral dilatation, increases of renal volume, and changes of echogenesity are shown by renal ultrasonography, VCUG should be performed. If a patient has difficulty undergoing VCUG, temporary postponement of VCUG can be taken into consideration, but only in cases where both examinations of renal ultrasonography and $^{99m}Tc$-DMSA renal scan are normal. Nevertheless, close observation is be advised even in this case.

Morphological classification of Renal Disease Using $^{99m}Tc-DMSA$ Scintigram ($^{99m}Tc-DMSA$ 신티그램을 이용한 신질환 형태 분류)

  • Moon, Tae-Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.237-244
    • /
    • 1991
  • $^{99m}Tc-DMSA$ renal scan has been evaluated not only the renal functional cell mass but also some anatomical structures at a loss of the renal parenchymal function. The author classified a renal morphology of the posterior image of $^{99m}Tc-DMSA$ renal scan as the groups of symmetric and asymmetric morphology, the groups of the large, normal and small sized kidneys, the groups of the central photon defects (PD) which could be noted in a dilated pelvocalyceal system due to obstructive uropathy and the cortical photon defects (CD) due to focal parenchymal lesions or scars after a loss of function and the last groups of the single and multiple CD for a suggestion of the clinical usefulness. Regarding to measurement of normal renal size, the longest size of the kidneys were evaluated with 5 cm of a lead scale on the posterior renal image, and those were decided to the limits beteen 104.1 and 119.4 mm as comparison with the renal size of intravenous pyelogram (IVP) in 59 cases who were underwent $^{99m}Tc-DMSA$ and IVP concommitantly. Among 85 cases of PD in $^{99m}Tc-DMSA$ renal scan, the 61 (71.8%) were cases of a dilated pelvocalyceal system related with obstructive uropathy, meanwhile the 28 (27.0%) of 162 cases with CD were cases of obstructive and infectious uropathy. The probability of a presence of some uropathy in cases of CD were 99.3%, meanwhile that of the presence of CD in cases of some uropathy were 37.9%. Besides, there were some specific anatomical findings such as polycystic kidneys with symmetric enlarged kidneys with multiple CD and the kidneys of chronic renal failure and/or hypertension with symmetric small size in $^{99m}Tc-DMSA$ renal stan.

  • PDF

$^{99m}Tc$-DMSA Scintigram for Renal Function Recovery after Therapy in Infants and Children (유소아 신질환에서 치료후 신기능회복에 대한 $^{99m}Tc$-DMSA 신티그램의 임상적 고찰)

  • Moon, Tae-Yong;Son, Hyun-Ju;Kim, In-Ju;Yoon, Chong-Byung;Lee, Suck-Hong;Kim, Byung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.69-74
    • /
    • 1994
  • Authors retrospectively analysed 20 cases of follow-up $^{99m}Tc$-DMSA renal scans to evaluate renal function recovery after treatment in urologic disorders of infants and children. There were 20 cases with both $^{99m}Tc$-DMSA renal scans prior to and after therapy in 15 patients below 9 years old. Among them, 10 patients underwent ureteroneocystostomy under the diagnosis of vesicoureteral reflux, two patients pyeloplasty because of obstructive uropathy and one was treated with antibiotics even diagnosis of UPJ stricture. We have got the quantified uptake rate of $^{99m}Tc$-DMSA renal scan by using the regression equation as "y=0.591x-2.105" (y=the quantified uptake rate, x=the simple uptake rate). The number of kidneys performed proper therapy were 29, and the cases with more increased radiotracer uptake rate in the follow-up $^{99m}Tc$-DMSA renal scans were 20 in number as 69% in frequency. 19 cases with improved renal function on $^{99m}Tc$-DMSA renal scans didn't show any significant difference related to aging or recovery duration after therapy. The $^{99m}Tc$-DMSA renal scans were not useful to evaluate renal function recovery in infants and children, but could be good tests to assess residual renal function prior to or after treatment.

  • PDF

Clinical Usefulness of 99mTc-DMSA Renal SPECT Using High Sensitivity-All Purpose Collimator for Pediatric Patients (고감도 범용성 콜리메이터를 이용한 소아 환자 99mTc-DMSA 신장 SPECT의 유용성)

  • Kim, Jin-Eui;Kim, Jung-Soo;Han, Jae-Bok;Choi, Nam-Gil
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.3
    • /
    • pp.219-231
    • /
    • 2016
  • $^{99m}Tc$-DMSA planar scan that can analyze the functions of kidney quantitatively provides less information on a lesion than tomography scanning. Therefore, this study applied a high sensitivity all-purpose collimator that is sensitive to photonic signals to $^{99m}Tc$-DMSA and carried out a clinical scan with single photon emission computed tomography (SPECT). And diagnostic accuracy and time requirement of were analyzed to know the clinical usefulness of the applied scanning method. 10 subjects were intravenously injected with radiopharmaceutical product (1.0-1.2 MBq/kg) and scanned by a gamma camera with planar scanner (high resolution (HR)-mode, $256{\times}256$, 50 kcts/view, 4 image) and SPECT (HR / high sensitive (HS)-mode, $128{\times}128$, step and shoot, $180^{\circ}$, variable sec/angle, total 64 frame, OSEM reconstruction), respectively. The collected data was compared with an analysis program. The results showed that HS-mode SPECT detected total counts 1.8-5.6 times more than planar scan. Relative renal function evaluated based on the counts was not significantly different by two scanning methods (p=0.96) and it turned out that test time was shortened by 39% when HS-mode SPECT was used. Therefore, SPECT using HR, HS-mode collimator could analyze renal function more quantitatively than using planar scan and the former could diagnose the location information of a lesion more accurately than the latter as well as shortened test time requirement, which demonstrated the clinical usefulness of $^{99m}Tc$-DMSA renal SPECT using high sensitivity all purpose collimator.

Is the Renal Uptake of $^{99m}Tc$-DMSA Decreased in Microalbuminuric Diabetic Patient? (미세 단백뇨기의 당뇨병 환자에서 $^{99m}Tc$-DMSA 신섭취율은 감소하는가?)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.398-404
    • /
    • 1999
  • Purpose: Diabetic nephropathy is the most common cause of end stage renal disease and the incidence is progressively increasing. The aim of this study was to investigate the differences of $^{99m}Tc$-DMSA renal uptake among diabetic patients with normoalbuminuria, microalbuminuria and overt proteinuria, and then to determine the clinical usefulness of $^{99m}Tc$-DMSA in predicting early diabetic nephropathy Materials and Methods: $^{99m}Tc$-DMSA scan was performed and a total renal uptake of $^{99m}Tc$-DMSA was measured in 145 diabetic patients. Patients were divided into 3 groups according to the amount of 24 hour urinary albumin excretion as Group I (normoalbuminuria, 74 cases), Group II (microalbuminuria, 39 cases), and Group III (overt proteinuria, 32 cases). The differences of $^{99m}Tc$-DMSA renal uptake among the 3 groups and the correlation between the renal uptake of $^{99m}Tc$-DMSA and other clinical parameters were analyzed. Results: The total renal uptake of $^{99m}Tc$-DMSA of Group II ($40.8{\pm}11.0%$) was significantly lower than that of Group I ($54.4{\pm}6.3%$, p<0.001). The uptake of Group III ($27.7{\pm}12.0%$) was significantly lower than those of both Group I and Group II (p<0.001). $^{99m}Tc$-DMSA total renal uptakes correlated negatively with serum creatinine level (r=-0.629, p<0.001) and positively correlated with creatinine clearance rate (r=0.102, p<0.001). Conclusion: $^{99m}Tc$-DMSA total renal uptake of diabetic patients with microalbuminuria was significantly decreased compared with that of patients of normoalbuminuria. Therefore, $^{99m}Tc$-DMSA scan can be used as a diagnostic study for early detection of the diabetic nephropathy.

  • PDF

Evaluation of Renal Uptake Rate in 99mTc-DMSA Scan on Pediatrics (소아 99mTc-DMSA 검사에서 신장 섭취율의 평가)

  • Baek, Seungju;Lee, Hyoyeong;Gil, Sanghyeong;Jo, Kyoungnam
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.235-238
    • /
    • 2015
  • The aims of this study were to evaluate the difference of renal uptake rate in $^{99m}Tc-DMSA$ scan on pediatrics by including the bladder. Phantom and Clinical studies were performed. In the phantom study, we put $^{99m}TcO_4{^-}$ (300uCi, 11 MBq) in 3cups filled with distilled water at the rate 1:1:0, 1:1:0.5, 1:1:1, 1:1:2 and were placed Lt kidney, Rt kidney and bladder position on the table. To acquire the image, we used Symbia-E gamma camera from Siemens with preset count method(400,000 counts). In quantitative analysis, the counts of drawing ROIs on the phantom were analyzed. In clinical studies, we analyzed the 20 pediatrics who were examined by $^{99m}Tc-DMSA$ scan. At first, the images were acquired with both kidney and bladder. Secondly we acquired images after shielding the bladder. And the data were compared using a pared t-test by SPSS(ver.22.0). As a result of renal phantom's experiment, we compared with average of uptake rate(%), 1:1:0 was Lt 43.32%, Rt 45.97%, 1:1:0.5 was Lt 35.79%, Rt 36.89%, 1:1:1 was Lt 29.68%, Rt 31.45% and 1:1:2 was Lt 22.89%, Rt 24.32%. There was no correlation between the zoom and uptake rate. The results of patient were that excluded bladder was $29.83{\pm}8.81%$(Lt), $24.29{\pm}6.66%$(Rt) and included bladder was $26.65{\pm}8.03%$(Lt, $21.78{\pm}6.24%$(Rt). This is deemed statistically significant (p<0.05). Renal uptake rate was undervalued because the counts of bladder were included in the total counts.