Tc-99m MIBI, Tc-99m Tetrofosmin, 그리고 Tc-99m (V) DMSA 스캔에 의해 발견된 재발성 악성 흉선종 (Recurrent Malignant Thymoma Detected by Tc-99m MIBI, Tc-99m Tetrofosmin and Tc-99m (V) DMSA Scan)

  • 석주원;김성장;김인주;김용기
    • 대한핵의학회지
    • /
    • 제35권4호
    • /
    • pp.268-273
    • /
    • 2001
  • Thymoma is the most common primary tumor of anterior mediastinum, accounting for 20% to 30% of all mediastinal tumors. The recurrence rate after total resection of the thymoma ranges 8% to 18%. We reported one patient of recurrent malignant thymoma imaged with Tc-99m MIBI, Tc-99m Tetrofosmin and Tc-99m (V) DMSA. Early and delayed Tc-99m MIBI and Tc-99m Tetrofosmin scintigraphies showed an increased uptake in the mediastinal area. Also, Tc-99m (V) DMSA scintigraphy revealed an increased uptake tn the corresponding area. Coronal SPECT images of Tc-99m MIBI, Tc-99m Tetrofosmin and Tc-99m (V) DMSA revealed increased uptake of each radiopharmaceutical in the tumor lesion corresponding to the mediastinal lesion on the chest CT. However, the normal blood pool activities of the heart and great vessels of Tc-99m (V) DMSA obscured the recurrent malignant thymoma. Although Tc-99m (V) DMSA is a useful tumor seeking agent, we recommend Tc-99m MIBI and Tc-99m Tetrofosmin SPECT rather than Tc-99m (V) DMSA to detect primary and recurrent malignant thymoma.

  • PDF

유방암이 의심되는 환자에서 $^{99m}Tc$-Tetrofosmin을 이용한 유방스캔: $^{99m}Tc$-MIBI와 비교 ($^{99m}Tc$-Tetrofosmin Scintimammography in Suspected Breast Cancer Patients: Comparison with $^{99m}Tc$-MIBI)

  • 김성장;김인주;김용기;배영태
    • 대한핵의학회지
    • /
    • 제34권2호
    • /
    • pp.119-128
    • /
    • 2000
  • 목적: 유방암이 의심되는 환자에서 $^{99m}Tc$-Tetrofosmin 유방 스캔과 $^{99m}Tc$-MIBI 유방 스캔의 유방암 진단성능을 비교하고자 하였다. 대상 및 방법: 유방 종물이나 방사선 유방촬영과 초음파 검사상 이상소견이 의심된 48명의 환자를 대상으로 $^{99m}Tc$-Tetrofosmin 유방 스캔과 $^{99m}Tc$-MIBI 유방스캔을 시행하였다. 조직결과는 33명의 환자에서는 수술로 확진 되었으며 15명의 환자는 세침흡인 세포진검사로 병리 결과를 얻었다. $^{99m}Tc$-MIBI 유방스캔은 925 MBq의 $^{99m}Tc$-MIBI를 정맥주사하고 엎드린 자세에서 양측 측면사진과 전흉부 영상을 획득하였다. $^{99m}Tc$-Tetrofosmin 유방 스캔은 43명의 환자에서는 $^{99m}Tc$-Tetrofosmin을 정맥주사 함과 동시에 80단위영상(1분/단위영상)의 동적 영상을 얻었으며 나머지 5명은 $^{99m}Tc$-MIBI 유방 스캔과 동일한 방법을 이용하였다. $^{99m}Tc$-Tetrofosmin 유방스캔과 $^{99m}Tc$-MIBI 유방 스캔의 결과를 병리조직 결과와 서로 비교 분석하였다. 결과 : 33명의 환자는 악성 유방암으로 진단되었으며, 15명은 양성 질환으로 진단되었다. $^{99m}Tc$-MIBI 유방 스캔의 진양성, 진음성, 위양성, 위음성은 19, 10, 5, 4이었으며 예민도, 특이도, 양성 예측률, 음성 예측률은 각각 87.8%, 66.7%, 85.3%, 71.4%였다. $^{99m}Tc$-Tetrofosmin 유방 스캔의 진양성, 진음성, 위양성, 위음성은 31, 10, 5, 2이었으며 예민도, 특이두 양성 예측률, 음성 예측률은 각각 93.9%, 66.7%, 86.1%, 73.3%였다. 한 명의 환자에서는 $^{99m}Tc$-Tetrofosmin 유방 스캔과 $^{99m}Tc$-MIBI 유방 스캔 모두에서 위음성을 보였는데 종양의 크기가 0.5 cm였다. 결론: $^{99m}Tc$-Tetrofosmin 유방 스캔과 $^{99m}Tc$-MIBl 유방 스캔 모두 유방암 진단에 비침습적이고 유용한 검사이며 $^{99m}Tc$-Tetrofosmin은 유방암 진단에서 $^{99m}Tc$-MIBI에 비교할 만한 성적을 보였으며, 유용하게 사용될 수 있으리라 여겨진다.

  • PDF

$^{99m}TcO^-{_4}$의 메틸-에틸-케톤-간편 추출법 (A Convenient Method on the Methyl-Ethyl-Ketone Extraction of $^{99m}TcO^-{_4}$)

  • 이종두;이병헌
    • Journal of Radiation Protection and Research
    • /
    • 제9권2호
    • /
    • pp.103-111
    • /
    • 1984
  • 간편형으로 $^{99m}Tc$-메틸-에틸-케톤(MEK) 추출법을 개량하고 이동 가능형으로 $^{99m}Tc$추출 장치를 설계하였다. $^{99m}TcO^-{_4}$의 MEK 추출 및 상 분리를 한 용기에서 하도록 하여 조작을 간편하게 하였으며 $^{99}Mo$의 방사능 차폐를 한개의 납용기로 할 수 있도록 하였다. $^{99m}TcO^-{_4}({\gamma}_e=0.14\;MeV)$를 분리차폐를 하여 장치를 간소화하였다. $^{99m}Tc-MEK$ 추출액중의 $^{99m}TcO^-{_4}$를 흡착 및 용리만에 의하여 회수할 수 있도록 하며 방사능 휘발 가능성을 줄이었고 알루미나 칼람을 소형으로 하여 $^{99m}TcO^-{_4}$염 제품의 부피를 1 ml로 줄이고 칼람 조작시간을 단축하였다. $^{99m}Tc$ 분리시간을 30분대로 줄이고 조작을 차폐밖에서 할 수 있도록 하였다. 장치를 무균 조작할 수 있도록 설계하였다.

  • PDF

유방암 환자의 전초림프절 검사에서 Tc-99m Tin-colloid와 Tc-99m Phytate의 효용성에 대한 비교 (Camparison of the Efficiency for Tc-99m Tin-colloid and Tc-99m Phytate in Sentinel Node Detection in Breast Cancer Patients)

  • 석주원;김인주
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권6호
    • /
    • pp.451-455
    • /
    • 2008
  • 목적 : 전초림프절 스캔과 전초림프철 생검은 유방암 환자에서 액와림프절 전이를 인지하기 위한 표준화된 방법으로 사용되게 되었지만, 표준화된 방사성의약품은 마련되어 있지 않다. 액와림프절 전이를 인지하기 위한 전초림프절 검사에 있어서 본 연구에서는 Tc-99m Tin-colloid와 Tc-99m Phytate의 결과를 비교하여 보았다. 대상 및 방법: 본 연구에서는 2001년에서 2008년까지 유방암으로 수술을 시행했던 381명의 환자를 대상으로 하였다. 349명의 환자는 Tc-99m Tin-colloid (37-185MBq) 0.8ml를 유륜하로 주사하였다. 33명의 환자는 Tc-99m Phytate (37-185 MBq) 0.8 ml를 유륜하로 주사하였다. 앉은 자세에서 림프신티그라피가 시행되었고, 수술 중에 감마프로브로 전초림프절을 발견하였다. 결과: Tc-99m Tin-celloid로 검사를 시행한 전체 349명의 환자 중에서 312명(89.4%)이 림프신티그라피에 의해 전초림프절이 발견되었고, 304명(87.1%)이 감마프로브에 의해 전초림프절이 발견되었다. 전날검사를 시행한 전체 33명의 환자 중에서 32명(97.0%)이 림프신티그라피에 의해 전초림프절이 발견되었고 33명(100%)이 감마프로브에 의해 전초림프절이 발견되었다. Tc-99m Phytate에 의한 림프신티그라피와 감마프로브에 의한 전초림프절 발견율은 Tc-99m Tin-celloid와 비교하여 통계학적으로 유의하게 높았다 (p<0.05, P<0.05). 결론: 유방암 환자에서 전초림프절을 발견하는데 있어 Tc-99m Phytate가 Tc-99m Tin-colloid보다 더 좋은 선택일 것이다.

Fibrous Dysplasia Associated with Primary Hyperparathyroidism Absent of McCune-Albright Syndrome: Tc-99m MIBI and Tc-99m MDP Findings

  • Kim, Seong-Jang;Seok, Ju-Won;Kim, In-Ju;Kim, Yong-Ki;Kim, Dong-Soo
    • 대한핵의학회지
    • /
    • 제37권2호
    • /
    • pp.128-134
    • /
    • 2003
  • 섬유성 골이형성증은 비정상적인 섬유성 골조직으로 대체되며 느리게 진행하는 골병변이다. 섬유성 골이형성증과 부갑상선기능항진증은 흔하게 관찰되는 질환이나 McCune-Albright 증후군 없이 일차성 부갑상선기능항진증에 동반된 섬유성 골 이형성증은 거의 보고된바가 없다. Tc-99m MDP 골스캔이 섬유성 골이형성증의 진단에 유용하다고 알려져 있으나, Tc-99m MIBI 영상은 아직 보고된 바가 없다. 저자들은 McCune-Albright 증후군이 없이 부갑상선기능항진증에 동반된 섬유성 골 이형성증의 Tc-99m MIBI 스캔과 Tc-99m MDP 골스캔의 영상을 비교하였다. Tc-99m MDP 골스캔상 병변 부위에서 증가된 섭취 소견을 보였으며, Tc-99m MIBI 조기영상에서도 동일한 위치에서 섭취증가가 관찰되었다. 2시간 지연 Tc-99m MIBI 영상에서는 Tc-99m MIBI의 섭취가 배출되는 소견을 보였다. 섬유성 골이형성증 병변에서 Tc-99m MIBI 스캔이 유용할 것이라고 생각하며, 섬유성 골이형성증 병변에서 Tc-99m MIBI의 섭취를 증가시키는 인자에 대한 더 많은 연구가 필요할 것으로 생각한다.

Methylenediphosphonate $(MDP)-^{99m}Tc$의 안정도(安定度)에 관(關)한 연구(硏究) (Studies on the Stability of $Methylenediphosphonate-^{99m}Tc$)

  • 김재록;오옥두;박경배;구현숙
    • 대한핵의학회지
    • /
    • 제16권2호
    • /
    • pp.81-84
    • /
    • 1982
  • To evaluate the in-vivo and in-vitro stability of methylene diphosphonate $(MDP)-^{99m}Tc$, relative ligand exchange rates in phosphate buffer between $MDP-^{99m}Tc$ and human serum albumin (HSA), and between pyrophosphate$(PYP)-^{99m}Tc$ and HSA have been measured. Gel permeation chromatography has also been carried out to estimate relative rates of ligand exchange between polysaccharide and the $^{99m}Tc-bone$ agents. The in-vitro stability was further correlated with its specific radioactivity. The results indicated that the $MDP-^{99m}Tc$ is more stable than the $PYP-^{99m}Tc$ but less stable than $MIDA-^{99m}Tc$, $HIDA-^{99m}Tc$, and $DTPA-^{99m}Tc$ etc. in refering to other data. In stability point of view, $MDP-^{99m}Tc$ is considered to be a better bone agent than $PYP-^{99m}Tc$ since $MDP-^{99m}Tc$ can be accumulated at bone by a smooth transfer of $^{99m}Tc$ to hydroxyapatite, whereas in case of $PYP-^{99m}Tc$, most of the $^{99m}Tc$ is transferred to HSA before arriving to the hydroxyapatite.

  • PDF

Tc-99m MDP와 Tc-99m DTPA 신티그라피를 시행한 환자의 말초혈액 림프구에서 유도되는 방사선 적응반응의 비교 (Comparison of Radiation Adaptive Responses in Peripheral Lymphocytes of Patients Undergoing Tc-99m MDP and Tc-99m DTPA Scintigraphies)

  • 범희승;이명호;민정준;권안성;김지열
    • 대한핵의학회지
    • /
    • 제34권3호
    • /
    • pp.252-259
    • /
    • 2000
  • 목적: 핵의학과에서 흔하게 이용되는 Tc-99m MDP 또는 Tc-99m DTPA를 주사한 후 방사선 적응반응이 일어나는지를 확인하고, 어느 경우에 방사선 적응반응이 더 현저하게 유도되는지 알아보기 위하여 이 연구를 시행하였다. 대상 및 방법: Tc-99m MDP 또는 Tc-99m DTPA 신티그라피를 시행한 45명의 환자(남자 25명, 여자 20명, 평균 연령 $44{\pm}18$세)를 대상으로 Tc-99m MDP 뜨는 Tc-99m DTPA 주사 전과 주사 후 4시간에 각각 5 ml씩 채혈하여 배양하고 배양 46시간 후에 Cs-137조사기 (central dose rate=654 Gy/h, Gammacell 3000 Elan, Nordion, Canada)를 이용하여 2 Gy의 감마선을 조사하였다. 대조군 20명(남자 12명, 여자 8명, 평균연령 $43{\pm}7$세)의 혈액을 채혈하여 Tc-99m MDP 또는 Tc-99m DTPA 주사 전에 채혈한 군과 같은 방법으로 조사하고 배양하였다. Colcemid 처리 2시간 후에 수확하여 불안정 염색체인 반지형과 이중 중심체형 염색체의 수자를 계수 하여 불안정 염색체 출현빈도(Ydr)를 구하여 비교하였다. 고선량의 방사선 단독조사에 의한 Ydr값과 방사성의약품 투여 후 고선량의 방사선 조사에 의해 유도된 Ydr값의 차이값을 적응반응지수로 정의하고, Tc-99m MDP 신티그라피와 Tc-99m DTPA 신티그라피의 적응반응지수를 비교하였다. 결과. 2 Gy 단독조사에 의한 Ydr값에 비해 Tc-99m MDP 또는 Tc-99m DTPA 주사한 후에 2 Gy 조사한 군에서 Ydr값이 유의하게 감소하였다($0.45{\pm}0.20\;vs.\;0.24{\pm}0.10$, p=0.001). Tc-99m MDP 또는 Tc-99m DTPA에 의해 유도된 적응반응은 단백합성억제제인 cycloheximide에 의해 억제되었다($0.24{\pm}0.10\;vs.\;0.43{\pm}0.16$, p=0.001). Tc-99m MDP 신티그라피에 의한 적응반응 지수는 Tc-99m DTPA 신티그라피에 의한 적응반응지수에 비해 유의하게 높았다($0.10{\pm}0.06\;vs.\;0.24{\pm}0.05$, p=0.0001). 결론: Tc-99m MDP 신티그라피 또는 Tc-99m DTPA 신티그라피에 의한 저선량의 방사선 조사에 의하여 말초혈액 림프구에서 방사선 적응반응이 유도되었고, 적응반응의 정도는 Tc-99m MDP 골 신티그라피를 시행하는 환자에서 더욱 현저함을 알 수 있었다.

  • PDF

$Al^{3+}$ 존재가 $^{99m}Tc$-MDP의 표지효율과 생체내 분포에 미치는 영향 (Effect of $Al^{3+}$ on Labeling Efficiency and Biodistribution of $^{99m}Tc$-MDP)

  • 장영수;정재민;김영주;곽철은;이동수;정준기;이명철;고창순
    • 대한핵의학회지
    • /
    • 제30권3호
    • /
    • pp.361-366
    • /
    • 1996
  • 본 연구는 $^{99}Mo-^{99m}Tc$ 발생기시스템에서 용출될 수 있는 알루미늄이 $^{99m}Tc$-MDP의 표지효율과 생체내 분포에 어떤 영향을 미치는지를 보기 위한 실험이다. 알루미늄이온 농도 ($0-62.5{\mu}g/ml$)를 증가시킬수록 $^{99m}Tc$-MDP의 표지효율은 급격히 떨어지며 상대적으로 $^{99m}Tc$ pertechnetate와 hydrolyzed reduced $^{99m}Tc$ 부위의 상대적인 양은 증가되었다. $^{99m}Tc$-MDP는 알루미늄 존재하에서도 상당히 안정하였다. 알루미늄에 의해 $^{99m}Tc$-MDP 반응물이 교질을 형성하는지를 보기 위해 $0.22{\mu}m$ syringe filter로 여과한 액은 여과하지 않은 것과 유의한 차이를 나타내지 않았다. 마우스에 대한 생체내 분포실험은 알루미늄에 의해 $^{99m}Tc$-MDP의 표지효율이 떨어지고 $^{99m}Tc$ pertechnetate의 증가로 인해 혈액과 심장의 흡수는 증가하나 간과 뼈의 흡수는 별다른 차이를 나타내지 않았다. 랫트의 골스캔에서는 $5{\mu}g/ml$의 알루미늄농도에서는 영상의 차이가 없으나 $10{\mu}g/ml$ 농도에서는 하복부의 흡수가 높게 나타났다. 이상의 결과는 알루미늄이 $^{99}Mo-^{99m}Tc$ 발생기시스템 칼럼의 용출제한량인 $10{\mu}g/ml$이하에서도 MDP의 표지효율에 상당한 영향을 미칠 수 있다는 것을 보여준다. 따라서$^{99m}Tc$-MDP 골스캔시 연조직에의 흡수가 보이는 경우에도 방사성의약품의 방사화학적 순도에 대한 정도관리가 충분히 이루어 졌다면 $^{99}Mo-^{99m}Tc$ 발생기시스템에서 용출되는 알루미늄에 의한 영향은 배제될 수 있다.

  • PDF

원발성 부갑상선 기능 항진증의 수술전 병소확인에서 $^{99m}Tc$-Sestamibi 스캔의 유용성 (The Usefulness of $^{99m}Tc$-Sestamibi Scan in Preoperative Localization in Primary Hyperparathyroidism)

  • 백세현;김수미;최경묵;최윤상;김상진;유재명;최동섭;최재걸
    • 대한핵의학회지
    • /
    • 제29권4호
    • /
    • pp.465-472
    • /
    • 1995
  • 목적 : 원발성 부갑상선기능 항진증의 대부분의 원인인 부갑상선 선종의 유일한 완치는 수술이며 수술의 성패에 가장 중요한 것은 수술전의 정확한 ??소의 확인이다. 다양한 영상검사들이 동원되고있으나 각가 결점이 있고 가장 특이도가 높은 $^{201}T1-^{99m}Tc$감영 촬영방법도 검사방법등에 문제점이 있다. 이에 원발성 부갑상선기능 항진증 환자에게 최근에 사용되고있는 $^{99m}Tc$-Sestamibi 부갑상선 스캔의 유용성을 알아보고자 하였다. 대상 및 방법 : 19명의 부갑상선기능 항진증환자에서 모든 환자에게 초음파 검사, CT, $^{201}T1-^{99m}Tc$감영 촬영을 시행하고 그중 5명은 $^{99m}Tc$-Sestamibi 부갑상선 스캔을 시행하여 수술후 확진결과와 함께 비교하였다. 결과 : 초음파 검사와 CT 및 $^{201}T1-^{99m}Tc$감영 스캔은 19예중 각가 12예(67.1%), 14예(78.9%) 그리고 17예(89.5%)에서 병소확인이 가능하였고 $^{99m}Tc$-Sestamibi 부갑상선 스캔은 시행한 5예(100%) 모두에서 병소 확인이 가능하였다. 결론 : 이상의 결과로 $^{99m}Tc$-Sestamibi 부갑상선 스캔은 원발성 부갑상선기능 항진증의 수술전 병소확인에서 유용한 검사법으로 이용될 수 있으리라 사료된다.

  • PDF

마이크로웨이브와 Sep-Pak 카트리지를 이용한 $^{99m}Tc$-ECD, $MAG_3$, MIBI의 신속한 제조 및 정도관리 (Rapid Preparation and Quality Control of $^{99m}Tc$-ECD, $MAG_3$ and MIBI using Microwave Heating and Sep-Pak Cartridges)

  • 오승준;문대혁;류진숙;이희경
    • 대한핵의학회지
    • /
    • 제33권4호
    • /
    • pp.430-438
    • /
    • 1999
  • 목적: 마이크로웨이브를 이용한 방사성 동위원소의 표지와 Sep-Pak 카트리지를 이용한 정도관리 방법의 개선으로 신속한 제조가 가능하면서도 높은 표지효율을 가진 방사성 의약품을 얻고자 하였다. 대상 및 방법: $C_{18}$ 그리고 alumina N Sep-Pak카트리지를 이용한 정도관리 방법을 $^{99m}Tc$-ECD, $^{99m}Tc$-MIBI, $^{99m}Tc-MAG_3$에 적용하였고 표지효율을 측정하였다. 마이크로웨이브를 사용하여 상기의 키트에 방사성 동위원소를 표지하여 표지효율을 비교하였다. 결과: 마이크로웨이브에 의해 생성된 세 가지방사성 의약품은 3 ml용액에 $^{99m}Tc$-ECD와 $^{99m}Tc$-MIBI는 10초, $^{99m}Tc-MAG_3$는 15초의 짧은 마이크로웨이브를 조사하여 모두 95% 이상의 표지효율을 나타내었다. $^{99m}Tc$-ECD와 $^{99m}Tc$-MIBI는 Sep-Pak alumina N 카트리지를 사용하여 짧은 시간 내에서도 정확한 정도관리 결과를 얻을 수 있었다. 방사성 의약품의 제조시간은 정도관리를 포함하여 모두 6분 이하를 나타내었다. 결론: Sep-Pak 카트리지를 이용한 정도관리 방법과 마이크로웨이브에 의한 방사성 의약품의 제조 방법은 일상적인 방사성 의약품의 제조에 적용이 가능하였으며, 방사성 의약품의 제조시간을 크게 단축시킬 수 있었다.

  • PDF