• Title/Summary/Keyword: $^{238}U$

Search Result 210, Processing Time 0.028 seconds

DETERMINATION OF THE TRANSURANIC ELEMENTS INVENTORY IN HIGH BURNUP PWR SPENT FUEL SAMPLES BY ALPHA SPECTROMETRY-II

  • Joe, Kih-Soo;Song, Byung-Chul;Kim, Young-Bok;Jeon, Young-Shin;Han, Sun-Ho;Jung, Euo-Chang;Song, Kyu-Seok
    • Nuclear Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.99-106
    • /
    • 2009
  • The contents of transuranic elements ($^{237}Np$, $^{238}Pu$, $^{239}Pu$, $^{240}Pu$, $^{241}Am$, $^{244}Cm$, and $^{242}Cm$) in high-burnup spent fuel samples ($35.6{\sim}53.9\;GWd/MtU$) were determined by alpha spectrometry. Anion exchange chromatography and diethylhexyl phosphoric acid extraction chromatography were applied for the separation of these elements from the uranium matrix. The measured values of the nuclides were compared with ORIGEN-2 calculations. For plutonium, the measurements were higher than the calculations by about $2.6{\sim}32.7%$ on average according to each isotope, and those for americium and curium were also higher by about $35.9{\sim}63.1%$. However, for $^{237}Np$, the measurements were lower by about 52% on average for the samples.

A Study on the Development and Optimization Design of Isolator by Using the 3D Simulator (3D Simulator를 이용한 아이솔레이터 최적화 설계 및 개발에 관한 연구)

  • Jung Seung-Woo;Choi U-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.3 s.106
    • /
    • pp.229-238
    • /
    • 2006
  • In this paper, developed study about isolator that after design and optimizes center strip to use 3-D simulator. We use the factor about the change and propose simple mode of the simulation. Design strip line that center frequency is 1.85 GHz by software that use 3-D finite element method(FEM) and confirmed variable. Developed isolator were shown that more than isolation 25 dB, reflection loss has the more than 25 dB and insertion loss does not 0.2 dB. We could confirm that compare with simulation and manufacture sample propertied agrees more than 90 %.

Pharmacokinetic Preformulation Study of rH IL-2 (인터루킨-2의 제제설계를 위한 체내 동태학적 연구)

  • Seo, Min-Seok;Shim, Chang-Koo;Kwon, Jong-Bum;Na, Do-Sun;Lee, Sun-Bok;Hahm, Kyung-Soo;Han, Moon-Hi
    • YAKHAK HOEJI
    • /
    • v.34 no.4
    • /
    • pp.238-243
    • /
    • 1990
  • Pharmacokinetic characteristics of recombinant human interleukin-2 (rH IL-2) wre studied in the rat. First, different doses of rH IL-2 ranging from 6,400 to 1,600,000 U/kg were injected intravenously and the effect of dose size on the pharmacokinetics was examined. There was no dose dependency in the pharmacokinetics of rHIL-2 in the dose range of 6,400-40,000 U/kg. But at the dose of 1,600,000 U/kg, there was a severe hemolysis throughout the experiment and the pharmacokinetic parameters such as Vdss and CLt were significantly increased compared to those obtained from lower doses. It also showed that this drug is hardly distributed to the peripheral tissues and hardly eliminated from the body, since the valume of distribution (Vdss) and total body clearance (CLt) were 45-75 ml/kg and 1-2 ml/min/kg, respectively. The Vdss is close to the actual plasma volume and the CLt is less than glomerular filtration rate (GFR). Therefore it seemed that rH IL-2 is distributed only in the plasma pool and hardly filtered in the kidney due to its very large molecular weight. Second, rH IL-2 was administered to the rat via several routes such as hepatic portal vein (PV), intraperitoneal (IP), peroral (PO) and intranasal (IN) routes. The bioavailabilities (BA) of PV, IP, PO and IN routes were 96.8, 4.9, 0 and 0.1%, respectively. The addition of some nasal absorption enhancers such as taurocholate, taurodeoxycholate, glycocholate and glycodeoxycholate did not increase the BA of intranasaly administered rH IL-2. The result is contrast to the effect of these bile salts on the nasal absorption of ${\alpha}-inteferon$. Considering it together with the pharmacokinetic parameters, very large molecular weight of rH IL-2 seemed again to be the cause to very poor membrane permeability.

  • PDF

Analysis fo the Rock Joint Strength Characteristics Using New Rock Joint Roughness Quantification Method (암석의 절리면 거칠기 정량화 기법 개발을 통한 절리면 전단강도 특성 분석)

  • 이인모;홍은수;배석일;이석원
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.229-238
    • /
    • 2002
  • This paper introduces the surface roughness parameter, Rs to the characterization of joint roughness and quantitatively illustrates the influence of joint roughness on the joint shear strength. A new peak shear strength criterion for rock joints using Rs is suggested. The results show that the surface roughness parameter, Rs can appropriately reflect the degree of roughness for the rock joint surfaces tested in this study A measuring interval of 2mm and profile length of 5cm can be used to characterize the joint roughness of the rock core size surfaces; however, the scale of fluctuation, $\delta_\alpha$ should be considered to extend the surface roughness parameter, Rs to the large-scale field rock joint surfaces. For the smooth joint roughness, sliding of the rock cores is the principal shear mechanism; however, the breakage of roughness from the rock cores is inferred for rougher joint roughness.

Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study

  • Lee, Du-Hyeong;An, Seo-Young;Hong, Min-Ho;Jeon, Kyoung-Bae;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.207-213
    • /
    • 2016
  • PURPOSE. A recently introduced direct drill-guiding implant surgery system features minimal tolerance of surgical instruments in the metal sleeve by using shank-modified drills and a sleeve-incorporated stereolithographic guide template. The purpose of this study was to evaluate the accuracy of this new guided surgery system in partially edentulous patients using geometric analyses. MATERIALS AND METHODS. For the study, 21 implants were placed in 11 consecutive patients using the direct drill-guiding implant surgery system. The stereolithographic surgical guide was fabricated using cone-beam computed tomography, digital scanning, computer-aided design and computer-assisted manufacturing, and additive manufacturing processes. After surgery, the positional and angular deviations between planned and placed implants were measured at the abutment level using implant-planning software. The Kruskal-Wallis test and Mann-Whitney U test were used to compare the deviations (${\alpha}=.05$). RESULTS. The mean horizontal deviations were 0.593 mm (SD 0.238) mesiodistally and 0.691 mm (SD 0.344) buccolingually. The mean vertical deviation was 0.925 mm (SD 0.376) occlusogingivally. The vertical deviation was significantly larger than the horizontal deviation (P=.018). The mean angular deviation was 2.024 degrees (SD 0.942) mesiodistally and 2.390 degrees (SD 1.142) buccolingually. CONCLUSION. The direct drill-guiding implant surgery system demonstrates high accuracy in placing implants. Use of the drill shank as the guiding component is an effective way for reducing tolerance.

Improvement of Microstructure and Creep Properties of Ti-6Al-4V alloy by Plasma Carburization (Ti-6Al-4V 합금의 미세조직 및 크리프 특성에 미치는 플라즈마 침탄 처리의 영향)

  • Park, Y.G.;Wey, M.Y.;Park, J.U.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.17 no.2
    • /
    • pp.94-100
    • /
    • 2004
  • In order to improve the wear resistance of Ti-6Al-4V alloy, plasma carburization treatment was newly carried out without consumption of its good specific strength and fatigue life over the temperature. Effect of the plasma carburization was analyzed and compared with the non-treated alloy by microstructural observation, structure characterization and mechanical test. The plasma treated alloy formed a carburized layer of about $150{\mu}m$ in depth from the surface, where a fine and hard particles of TiC and $V_4C_3$ were homogeneously dispersed through the layer. The steady-static creep behaviors of Ti-6Al-4V alloy, using the constant stress creep tester, were investigated over the temperature range of $510{\sim}550^{\circ}C$(0.42~0.44Tm) and the stress range of 200~275 MPa. Stress exponent(n) was decreased from 9.32 of non-treatment specimen to 8.95 of carburized, however, the activation energy(Q) increased from 238 to 250 kJ/mol with the same condition as indicated above. From the above results, it can be concluded that the static creep deformation for Ti-6Al-4V alloy was controlled by the dislocation climb over the ranges of the experimental conditions.

Gamma-ray Full Spectrum Analysis for Environmental Radioactivity by HPGe Detector

  • Jeong, Meeyoung;Lee, Kyeong Beom;Kim, Kyeong Ja;Lee, Min-Kie;Han, Ju-Bong
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.317-323
    • /
    • 2014
  • Odyssey, one of the NASA's Mars exploration program and SELENE (Kaguya), a Japanese lunar orbiting spacecraft have a payload of Gamma-Ray Spectrometer (GRS) for analyzing radioactive chemical elements of the atmosphere and the surface. In these days, gamma-ray spectroscopy with a High-Purity Germanium (HPGe) detector has been widely used for the activity measurements of natural radionuclides contained in the soil of the Earth. The energy spectra obtained by the HPGe detectors have been generally analyzed by means of the Window Analysis (WA) method. In this method, activity concentrations are determined by using the net counts of energy window around individual peaks. Meanwhile, an alternative method, the so-called Full Spectrum Analysis (FSA) method uses count numbers not only from full-absorption peaks but from the contributions of Compton scattering due to gamma-rays. Consequently, while it takes a substantial time to obtain a statistically significant result in the WA method, the FSA method requires a much shorter time to reach the same level of the statistical significance. This study shows the validation results of FSA method. We have compared the concentration of radioactivity of $^{40}K$, $^{232}Th$ and $^{238}U$ in the soil measured by the WA method and the FSA method, respectively. The gamma-ray spectrum of reference materials (RGU and RGTh, KCl) and soil samples were measured by the 120% HPGe detector with cosmic muon veto detector. According to the comparison result of activity concentrations between the FSA and the WA, we could conclude that FSA method is validated against the WA method. This study implies that the FSA method can be used in a harsh measurement environment, such as the gamma-ray measurement in the Moon, in which the level of statistical significance is usually required in a much shorter data acquisition time than the WA method.

OECD/NEA BENCHMARK FOR UNCERTAINTY ANALYSIS IN MODELING (UAM) FOR LWRS - SUMMARY AND DISCUSSION OF NEUTRONICS CASES (PHASE I)

  • Bratton, Ryan N.;Avramova, M.;Ivanov, K.
    • Nuclear Engineering and Technology
    • /
    • v.46 no.3
    • /
    • pp.313-342
    • /
    • 2014
  • A Nuclear Energy Agency (NEA), Organization for Economic Co-operation and Development (OECD) benchmark for Uncertainty Analysis in Modeling (UAM) is defined in order to facilitate the development and validation of available uncertainty analysis and sensitivity analysis methods for best-estimate Light water Reactor (LWR) design and safety calculations. The benchmark has been named the OECD/NEA UAM-LWR benchmark, and has been divided into three phases each of which focuses on a different portion of the uncertainty propagation in LWR multi-physics and multi-scale analysis. Several different reactor cases are modeled at various phases of a reactor calculation. This paper discusses Phase I, known as the "Neutronics Phase", which is devoted mostly to the propagation of nuclear data (cross-section) uncertainty throughout steady-state stand-alone neutronics core calculations. Three reactor systems (for which design, operation and measured data are available) are rigorously studied in this benchmark: Peach Bottom Unit 2 BWR, Three Mile Island Unit 1 PWR, and VVER-1000 Kozloduy-6/Kalinin-3. Additional measured data is analyzed such as the KRITZ LEU criticality experiments and the SNEAK-7A and 7B experiments of the Karlsruhe Fast Critical Facility. Analyzed results include the top five neutron-nuclide reactions, which contribute the most to the prediction uncertainty in keff, as well as the uncertainty in key parameters of neutronics analysis such as microscopic and macroscopic cross-sections, six-group decay constants, assembly discontinuity factors, and axial and radial core power distributions. Conclusions are drawn regarding where further studies should be done to reduce uncertainties in key nuclide reaction uncertainties (i.e.: $^{238}U$ radiative capture and inelastic scattering (n, n') as well as the average number of neutrons released per fission event of $^{239}Pu$).

Hydrogeochemical Characteristics and Natural Radionuclides in Groundwater for Drinking-water Supply in Korea (국내 음용지하수의 수리지화학 및 자연방사성물질 환경 특성)

  • Jeong, Do-Hwan;Kim, Moon-Su;Lee, Young-Joon
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.6
    • /
    • pp.133-142
    • /
    • 2011
  • A total of 247 samples were collected from groundwater being used for drinking-water supply, and hydrogeochemistry and radionuclide analysis were performed. In-situ analysis of groundwaters resulted in ranges of $13.7{\sim}25.1^{\circ}C$ for temperature, 5.9~8.5 for pH, 33~591 mV for Eh, $66{\sim}820{\mu}S/cm$ for EC, and 0.2~9.4 mg/L for DO. Major cation and anion concentrations of groundwaters were in ranges of 0.5~227.6 for Na, 1.0~279.3 for Ca, 0.0~9.3 for K, 0.1~100.1 for Mg, 0.0~3.3 for F, 0.9~779.1 for Cl, 0.3~120.4 for $SO_4$, 0.0~27.4 for $NO_3$-N, and 6~372 mg/L for $HCO_3$. Uranium-238 and radon-222 concentrations were detected in ranges of N.D-$131.1{\mu}g/L$ and 18-15,953 pCi/L, respectively. In case of some groundwaters exceeding USEPA MCL level ($30{\mu}g/L$) for uranium concentration, their pH ranged from 6.8 to 8.0 and Eh showed a relatively low value(86~199 mV) compared to other areas. Most groundwaters belonged to Ca-(Na)-$HCO_3$ type, and groundwaters of metamorphic rock exhibited the highest concentration of Na, Mg, Ca, Cl, $NO_3$-N, U, and those of plutonic rock showed the highest concentration of $HCO_3$, and Rn. Uranium and fluoride from granite areas did not show any correlation. However, uranium and bicarbonate displayed a positive relation of some areas in plutonic rocks($R^2$=0.3896).

Study on Ohmic resistance of Zn-doping InP using RTA method (RTA 방법에 의해 Zn 도핑된 InP의 오믹저항 특성연구)

  • Kim, H.J.;Kim, I.S.;Kim, T.U.;Kim, S.T.;Kim, S.H;Ki, H.C.;Lee, K.M.;Yang, M.H.;Ko, H.J.;Kim, H.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.237-238
    • /
    • 2008
  • Electrical properties of Pd/Zn/Pd/Au contacts to p-InP were investigated as function of the V/III ratio of p-InP. P-type InP was made by the Zn diffusion into InP and activation process with rapid thermal annealing (RTA) measurement. After activation, the hole concentration was two orders of magnitude higher than that of the sample having only diffusion process. According to transmission line method (TLM) results, the specific contact resistance of p-InP was lower as used InP having the lower V/III ratio. The experimental results represent that the diffusion of Zn in undoped InP deeply related to the equilibrium between interstitials and substitutional Zn is established via indium interstitials.

  • PDF