• 제목/요약/키워드: $^{133}Cs$

검색결과 90건 처리시간 0.024초

Study on (n,p) reactions of 58Ni, 99Tc, 99Ru, 131Xe, 133Cs and 186Os radioisotopes used in medicine

  • Hallo M. Abdullah;Ali H. Ahmed
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.304-309
    • /
    • 2023
  • In the last decade, nuclear medicine appears to be a good choice of medicine. 58Co, 99Mo, 99Tc, 99Re, 133Xe and 186Re are very important radionuclides for nuclear medicine. In this study, the excitation functions of 58Ni (n, p) 58Co, 99Tc (n, p) 99Mo, 99Ru (n, p) 99Tc, 131Xe (n, p) 131I, 133Cs (n, p) 133Xe and 186Os (n, p) 186Re nuclear reactions were calculated at neutron energies between 1 and 20 MeV using TALYS 1.95 and EMPIRE 3.2 nuclear codes. Furthermore, the cross sections were calculated with the empirical formula derived in our past study at 14-15 MeV. The obtained results were compared with the measured values in EXFOR library, and with the evaluated data of (JENDL-4.0/HE, JEFF-3.3, TENDL-2019, ENDF/B-VIII.0, IRDFF-II, JENDL/ImPACT-18). The results are in good agreement with those of the evaluated data libraries and experimental results and indicates that these radioisotopes can be produced by smaller cyclotrons.

화학 및 천연 응집제를 이용한 수중 Cs, Sr 제거 (Removal of Cs and Sr in Water Using Chemical and Natural Coagulants)

  • 김성범;김영석;강성원;오대민;이원태
    • 대한환경공학회지
    • /
    • 제38권12호
    • /
    • pp.662-666
    • /
    • 2016
  • 응집/침전 기술로 지표수 내 방사성 핵종(Cs, Sr)의 제거 가능성을 평가하였다. 화학응집제는 Alum (aluminum sulfate), PAC (poly aluminum chloride), PACS (poly aluminum hydroxide chloride silicate)를 사용하였고, 광물계 천연응집제는 일라이트(illite)와 제올라이트(zeolite)를 사용하였다. 화학 및 천연 응집제는 각각 주입하거나 혼합 주입한 후 jar-test를 통하여 안정화된 방사성 핵종($^{133}Cs$, $^{88}Sr$)의 제거율을 평가하였다. 응집/침전 공정에서 화학응집제(Alum, PAC, PACS) 주입만으로는 Cs과 Sr이 10% 미만으로 제거되었고, 고분자응집제(polyDADMAC)를 혼합하여 주입할 경우 Cs은 최대 23.1%, Sr은 최대 17.8%까지 제거가 가능하였다. 광물계 천연응집제(zeolite, illite)는 화학응집제(Alum, PAC, PACS)에 비하여 Cs과 Sr의 제거율이 높았는데, 화학응집제(PACS)와 고분자응집제에 zeolite를 추가로 주입(10~200 mg/L)한 경우 Cs 제거율은 최대 36.9%, Sr 제거율은 최대 17.1%로 증가하였다.

Radiation measurement and imaging using 3D position sensitive pixelated CZT detector

  • Kim, Younghak;Lee, Taewoong;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1417-1427
    • /
    • 2019
  • In this study, we evaluated the performance of a commercial pixelated cadmium zinc telluride (CZT) detector for spectroscopy and identified its feasibility as a Compton camera for radiation monitoring in a nuclear power plant. The detection system consisted of a $20mm{\times}20mm{\times}5mm$ CZT crystal with $8{\times}8$ pixelated anodes and a common cathode, in addition to an application specific integrated circuit. The performance of the various radioisotopes $^{57}Co$, $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ was evaluated. In general, the amplitude of the induced signal in a CZT crystal depends on the interaction position and material non-uniformity. To minimize this dependency, a drift time correction was applied. The depth of each interaction was calculated by the drift time and the positional dependency of the signal amplitude was corrected based on the depth information. After the correction, the Compton regions of each spectrum were reduced, and energy resolutions of 122 keV, 356 keV, 511 keV, and 662 keV peaks were improved from 13.59%, 9.56%, 6.08%, and 5%-4.61%, 2.94%, 2.08%, and 2.2%, respectively. For the Compton imaging, simulations and experiments using one $^{137}Cs$ source with various angular positions and two $^{137}Cs$ sources were performed. Individual and multiple sources of $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ were also measured. The images were successfully reconstructed by weighted list-mode maximum likelihood expectation maximization method. The angular resolutions and intrinsic efficiency of the $^{137}Cs$ experiments were approximately $7^{\circ}-9^{\circ}$ and $5{\times}10^{-4}-7{\times}10^{-4}$, respectively. The distortions of the source distribution were proportional to the offset angle.

NEUTRON CROSS SECTION DATA LIBRARY FOR PD-105, AG-109, XE-131 AND CS-133

  • LEE Y. D.;CHANG J. H.
    • Nuclear Engineering and Technology
    • /
    • 제37권1호
    • /
    • pp.101-108
    • /
    • 2005
  • The neutron induced nuclear cross-section data for Pd-105, Ag-109, Xe-131, and Cs-133 were calculated and evaluated from an unresolved energy to 20 MeV. The energy dependent optical model potential parameters were extracted based on recent experimental data and applied up to 20 MeV. A spherical optical model and a statistical model for the equilibrium energy, and a multistep direct and a multistep compound model for the pre-equilibrium energy were used in the calculation. The direct capture model was recently introduced for fast neutron capture. The theoretically calculated cross-sections were compared with the experimental data and the evaluated files. The total and capture cross-sections calculated using the model were in good agreement with the reference experimental data. The evaluated cross-section results were compiled in ENDF-6 format and merged with the resonance component, already adopted in the ENDF/B-VI release 8. New data library files covering from thermal to 20 MeV were created. They are at the preliminary stage of an ENDF/B- VII release.

Ferroelectric-Paraelectric Phase Transition of CsH2PO4 studied by Static NMR and MAS NMR

  • Lim, Ae Ran;Lee, Kwang-Sei
    • 한국자기공명학회논문지
    • /
    • 제19권1호
    • /
    • pp.29-35
    • /
    • 2015
  • The microscopic dynamics of $CsH_2PO_4$, with two distinct hydrogen bond lengths, are studied by static nuclear magnetic resonance (NMR) and magic angle spinning (MAS) NMR. The proton dynamics of the two crystallographically inequivalent hydrogen sites were discussed in terms of the $^1H$ NMR and $^1H$ MAS NMR spectra. Although the hydrogen bonds have two inequivalent sites, H(1) and H(2), distinct proton dynamics for the two sites were not found. Further, the $^{133}Cs$ spectrum is more or less continuous near $T_{C1}$ (=153 K). Finally, the phase transition mechanism of $T_{C1}$ in $CsH_2PO_4$ is related to the ordering of protons.

초전센서를 이용한 무선 위치 인식 보정 시스템 (Compensation System for Wireless Location based on Pyroelectric sensor)

  • 성주현;조현종;김윤식;서동환
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2012년도 전기공동학술대회 논문집
    • /
    • pp.133-133
    • /
    • 2012
  • 본 연구에서는 현재의 실내 위치인식시스템에 있어서 오차 발생 문제점을 초전센서를 이용하여 보완하였다. 기존의 CSS기술은 SDS-TWR(Symmetric Double-Sided Two-Way Ranging) 기반의 위치인식시스템을 구현하는 기술로 사용되고 있으나 전파의 반사 및 간섭에 의해 레인징의 오차가 크게 발생하고 수신 감도가 현저하게 떨어지는 현상이 발생한다. 따라서 본 논문에서는 환경적인 제약을 받는 공간에서 CSS을 이용한 SDS-TWR과 초전센서를 사용하여 수신불량과 오차를 줄여 사용자의 위치인식을 가능하도록 하였다.

  • PDF

이성체쌍의 열중성자포획단면적비 측정

  • 박혜일;김헌준;이철
    • Nuclear Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.340-344
    • /
    • 1972
  • $^{79}$ Br, $^{80}$ Se, $^{103}$ Rh, $^{115}$ In 및 $^{133}$ Cs의 열중성자 포획시 혈성되는 이성체쌍의 비와 $^{79}$ Br, $^{80}$ Se 및 $^{l33}$Cs의 Epi-Cd 중성자 포획시 형성되는 이성체 쌍의 비를 측정하였다. 동 이성체비는 중성자 조사후 ${\gamma}$-선 분광분석법으로 얻은 붕괴곡선을 분석하여 측정하였다. 계측효율곡선은 전체불확실율이 악 1%인 표준선원을 사용하여 결정하였다. $\sigma$ high spin/($\sigma$ high spin+$\sigma$ low spin)으로 나타낸 열중성자로 생성된 $^{80, 80m}$Br, $^{81,81m}$Se, $^{014, 104m}$Rh, $^{116,116m}$In 및 $^{134, 134m}$Cs 쌍들의 이성체비는 각각 0.21$\pm$0.01, 0.14$\pm$0.02, 0.12$\pm$0.02, 0.69$\pm$0.07 및 0.058$\pm$0.004 이었다. Epi-Cd 중성자에 의해서 생성된 $^{80, 80m}$Br, $^{81,81m}$Se, 및 $^{134, 134m}$Cs 쌍의 이성체 비는 각각 0.19$\pm$0.02, 0.29$\pm$0.02 및 0,74$\pm$0,011 이었다. 실험적으로 얻은 본값을 통계적 모델로부터 얻은 이론치와 비교하여 본 결과 일반적인 일치를 보였다.다.

  • PDF

Evaluation of the effect of blood contamination on the compressive strength of MTA modified with hydration accelerators

  • Oloomi, Kaveh;Saberi, Eshaghali;Mokhtari, Hadi;Mokhtari Zonouzi, Hamid Reza;Nosrat, Ali;Nekoofar, Mohammad Hossein;Dummer, Paul Michael Howell
    • Restorative Dentistry and Endodontics
    • /
    • 제38권3호
    • /
    • pp.128-133
    • /
    • 2013
  • Objectives: This study was performed to evaluate the effect of blood contamination on the compressive strength (CS) of Root MTA (RMTA) modified with Calcium chloride ($CaCl_2$) and Disodium hydrogen phosphate ($Na_2HPO_4$) as setting accelerators over time. Materials and Methods: A total of 110 cylindrical specimens of RMTA were divided into 6 experimental groups as follows: Group1, RMTA; Group 2, RMTA modified with $CaCl_2$ (RMTA-C); Group 3, RMTA modified with $Na_2HPO_4$ (RMTA-N); Group 4, RMTA contaminated with blood; Group 5, RMTA-C contaminated with blood; Group 6, RMTA-N contaminated with blood. The CS of specimens in all groups was evaluated after 3 hr, 24 hr, and 1 wk. In the modified groups (groups 2, 3, 5, and 6) the CS of five specimens per group was also evaluated after 1 hr. Results: Blood contamination significantly reduced the CS of all materials at all time intervals (p < 0.05). After 3 hr, the CS of specimens in the RMTA groups (with and without blood contamination) was significantly lower than those in the RMTA-C and RMTA-N groups (p < 0.05). The CS values were not significantly different at the other time intervals. In all groups, the CS of specimens significantly increased over time (p < 0.05). Conclusions: Blood contamination decreased the CS of both original and accelerated RMTA.