• Title/Summary/Keyword: $^{131}I$ therapy

Search Result 118, Processing Time 0.021 seconds

Analysis of the Latest Trends of Radioisotope Using in RI-Biomics Fields (RI-Biomics분야 RI의 최신 동향 분석)

  • Jang, Sol-Ah;Yeom, Yu-Sun;Park, Tai-Jin;Hwang, Young Muk;Youn, Dol-Mi
    • Journal of Radiation Industry
    • /
    • v.7 no.2_3
    • /
    • pp.221-224
    • /
    • 2013
  • RI-Biomics is a new compound word of radiation technology and Biomics related to the study of life. RI-Biomics is high radiation fusion technology by combining evaluation of pharmacokinetics in vivo (RI-ADME) of new drugs and medical materials using radioisotope and molecular imaging technology using nuclear medicine equipments. RI-Biomics fields are emerging with the increasing usage of radioisotopes (RI). In this paper, we investigated the latest trends of radioisotope using in RI-Biomics fields. The representative radioisotopes are $^{14}C$, $^3H$ and $^{32}P$ for the optimization and the selection of candidates in the development process of new drugs among the RI-Biomics fields. As shown in the status of accumulated income of radioisotopes, using amounts of radioisotopes are showing a tendency to increase every year. $^{14}C$ is 61.6% increase of accumulated income growth rate and $^3H$ increased by 58.8% and $^{32}P$ increased by 33.9% in 2012 compared to 2007. These isotopes are used in a variety of fields as using of $^{14}C$ for microdosing test, development of [$^3H$]cholesterol absorption inhibitors, study of [$^{131}I$]pyronaridine tetraphosphate for malaria therapy. These are going on in vivo test sucessfully. So, clinical research step is expected to begin soon. Therefore, usages of radioisotopes are necessary and need for the evaluation of pharmacokinetics, optimization and the selection of new drug candidates in the development process of new drugs among the RI-Biomics fields. So, using of radioisotopes is predict to increase continuously except for primarily used $^{14}C$, $^3H$.

Synthesis of a PEGylated tracer for radioiodination and evaluation of potential in tumor targeting

  • Abhinav Bhise;Sushil K Dwivedi;Kiwoong Lee;Jeong Eun Lim;Subramani Rajkumar;Woonghee Lee;Seong Hwan Cho;Jeongsoo Yoo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.7 no.2
    • /
    • pp.79-84
    • /
    • 2021
  • Radiopharmaceuticals are important for tumor diagnosis and therapy. To deliver a radiotracer at the desired target excluding non-targeted tissues is difficult The development of a targeted tracer that has a good clearance profile while maintaining high biostability and biocompatibility is key to optimizing its biodistribution and transport across biological barriers. Improving the hydrophilicity of radiotracers by PEGylation can reduce serum binding, allowing the tracer to circulate without retention and reducing its affinity for non-targeted tissues. In this study, we synthesized a new benzamido tracer (SnBz-PEG36) with the introduction of a low molecular weight polyethylene glycol unit (PEG36, ~2,100 Da). The tumor targeting efficiency and biodistribution of [131I]-Bz-PEG36 or radiotracer-loaded liposomes were evaluated after their administration to normal mice or mouse tumor models including CT26 (xenograft) and 4T1 (xenograft and orthotopic). Most of the radiotracer was cleared out rapidly (1-24 h post-administration) through the kidney and there was little tumor uptake.

Comparison of Urine Iodine/Creatinine ratio between Patients following Stringent and Less Stringent Low Iodine Diet for Radioiodine Remnant Ablation of Thyroid Cancer (갑상선암의 방사성요오드치료를 위한 저요오드식이 방법 차이에 따른 소변 중 요오드/크레아티닌 비의 비교)

  • Roh, Jee-Ho;Kim, Byung-Il;Ha, Ji-Su;Chang, Sei-Joong;Shin, Hye-Young;Choi, Joon-Hyuk;Kim, Do-Min;Kim, Chong-Soon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.322-326
    • /
    • 2006
  • A low iodine diet (LID) for $1{\sim}2$ weeks is recommended for patients who undergoing radioiodine remnant ablation. However, the LID educations for patients are different among centers because there is no concrete recommendation for protocol of LID. In this investigation, we compared two representative types of LID protocols performed in several centers in Korea using urine iodine to creatinine ratio (urine I/Cr). Methods: From 2006, April to June, patients referred to our center for radioiodine remnant ablation of thyroid cancer from several local hospitals which had different LID protocols were included. We divided into two groups, stringent LID for 1week and less stringent LID for 2 weeks, then measured their urine I/Cr ratio with spot urine when patients were admitted to the hospital. Results: Total 27 patients were included in this investigation (M:F=1:26; 13 in one-week stringent LID; 14 in two-week less stringent LID. Average of urine I/Cr ratio was $127.87{\pm}78.52{\mu}g/g$ in stringent LID for 1 week, and $289.75{\pm}188.24{\mu}g/g$ in less stringent LID for 2 weeks. It was significantly lower in stringent LID for 1 week group (p=0.008). The number of patients whose urine I/Cr ratios were below $100{\mu}g/g$ was 6 of 13 in stringent LID for 1 week group, and 3 of 14 in less stringent LID for 2 weeks group. Conclusion: Stringent LID for 1 week resulted in better urinary I/Cr ratio in our investigation compared with the other protocol. However it still resulted in plenty of inadequate range of I/Cr ratio, so more stringent protocol such as stringent LID for 2 weeks is expected more desirable.

Therapeutic Effect of Different Doses of Recombinant Human Granulocyte Colony-Stimulating Factor(rhG-CSF) on Neonatal Sepsis Complicated by Neutropenia (호중구 감소증이 합병된 신생아 패혈증에서 Recombinant Human Granulocyte Colony-Stimulating Factor(rhG-CSF)의 투여 용량에 따른 치료 효과)

  • Choi, Moon Young;Jung, Yeon Sook;Son, Dong Woo;Ahn, Hyo Seop
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.439-448
    • /
    • 2002
  • Purpose : The aim of this study is to determine and compare the effects of adjunctive therapy with different doses of recombinant human granulocyte-colony stimulating factor(rhG-CSF) on reversing sepsis-associated neonatal neutropenia, and their survival rate in a group I/II-type trial. Methods : RhG-CSF was injected subcutaneously to 10 septic-neutropenic neonates with doses of $10{\mu}g/kg$ from Oct. 1995 to Sep. 1996, and was administered to another 12 septic-neutropenic neonates with doses of $5{\mu}g/kg$ from Oct. 1996 to Sep. 1997. Neutrophilic responses and the outcomes of both groups were compared. Results : In the rhG-CSF $10{\mu}g/kg$ treated group and in the $5{\mu}g/kg$ treated group, the absolute neutrophil count(ANC) was $1,065{\pm}89$($mean{\pm}SEM$) and $1,053{\pm}131$, respectively. The only difference between the two groups was the peak ANC at 48 hours. Eight patients from the remaining nine of rhG-CSF $10{\mu}g/kg$ treated group(88.9%) and ten in $5{\mu}g/kg$ treated group(83.3%) survived the sepsis and were discharged without any problems. Conclusions : RhG-CSF can increase the neutrophil count in critically ill septic neutropenic neonats. The survival rate of both groups were up to 90%. This finding suggests that both doses of rhG-CSF may be effective in a therapeutically useful time frame to treat septic neonates with neonatal neutropenia attributable to bone marrow supression or neutrophil consumption.

Treatment and Survial Rate of Malignant Peripheral Nerve Sheath Tumors (악성 말초신경막 종양의 치료와 생존율)

  • Lee, Jong-Seok;Jeon, Dae-Geun;Cho, Wan-Hyung;Lee, Soo-Yong;Oh, Jung-Moon;Kim, Jin-Wook
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.2
    • /
    • pp.131-138
    • /
    • 2003
  • Purpose: We analyzed our malignant peripheral nerve sheath tumor (MPNST) cases to find out their oncologic results following by each treatment modalities. Materials and Methods: Thirty four patients with MPNST were registered in Korea Cancer Center Hospital from Feb. 1986 to Nov. 1996. Seventeen cases were male and 17, female. Average age was 41 years (range 18 to 74). Location of the tumor was as follows; 17 in lower extremity, 11 upper extremity, 4 trunk, and 2 retroperitoneum. Following the AJC classification, stage IA were 2 cases, stage IIA 2, stage IIB 6, stage III 16 and stage IV 8. Twenty six patients took operations and adjuvant chemotherapy and/or radiation therapy, 3 operation only and 3 adjuvant chemotherapy or radiation therapy. Average follow up period was 33.5 months (5.6 to 146.1). Kaplan-Meiyer method was done for survival curve, and log rank test for comparison analysis. Results: Fourteen cases were continuous disease free, 2 no evidence of disease, 2 alive with disease and 14 dead of disease states at final follow up. Actual 5-year and 10-year survival rates were 53.5%, 35.7%. Local recurrence rate after operation was 24.1%. 5-year survival rates of stage I/II/III were 100/85.7/55.9% and 2-year survival rate of stage IV was 14.3% (p=0.04). In 21 cases operated with stage II-III, wide margin (15cases) had 76.0% 5-year survival rate, and marginal or intralesional marigin (6cases) had 40.0%. The actual 5-year survival rate of the group which were done 4 or more cycles chemotherapy (8cases) was 71.4% and the actual 3-year survival rate less than 4cycles chemotherapy (6cases) was 83.3% (p=0.96). In 19 cases operated with stage II-III and which had no radiotherapy, marginal or intralesional margin (5cases) had 3 cases of local recurrences (60.0%), though wide margin (14cases) had 4 cases recurrences (28.6%). There was no local recurrence in 8cases which had pre-or post-operative radiotherapy. Conclusions: Surgical margin is an important factor in local recurrence. Resection margin has a tendency to influence the survival despite insufficient statistical significance. Conventional chemotherapy has no defnite statistical sigficance in the effect on local control and survival. Preoperative and postoperative radiotherapy has some positive effect on local control.

  • PDF

Dosimetric Characterization of an Ion Chamber Matrix for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료 선량분포 확인을 위한 2차원적 이온전리함 배열의 특성분석)

  • Lee, Jeong-Woo;Hong, Se-Mie;Kim, Yon-Lae;Choi, Kyoung-Sik;Jung, Jin-Beom;Lee, Doo-Hyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.131-135
    • /
    • 2006
  • A commercial ion chamber matrix was examined the characteristics and its performance for radiotherapy qualify assurance. The device was the I'mRT 2D-MatriXX (Scanditronix-Wellhofer, Schwarzenbruck, Germany). The 2D-MatriXX device consists of a 1020 vented ion chamber array, arranged in $24{\times}24cm^2$ matrix. Each ion chamber has a volume of $0.08cm^3$, spacing of 0.762 cm and minimum sampling time of 20 ms. For the investigation of the characteristics, dose linearity, output factor, short-term reproducibility and dose rate dependency were tested. In the testing of dose linearity. It has shown a good signal linearity within 1% in the range of $1{\sim}800$cGy. Dose rate dependency was found to be lower than 0.4% (Range: 100-600 Mu/min) relative to a dose rate of 300 Mu/min as a reference. Output factors matched very well within 0.5% compared with commissioned beam data using a ionization chamber (CC01, Scanditronix-Wellhofer, Schwarzenbruck, Germany) in the range of field sizes $3{\times}3{\sim}24{\times}24cm^2$. Short-term reproducibility (6 times with a interval of 15 minute) was also shown a good agreement within 0.5%, when the temperature and the pressure were corrected by each time of measurement. in addition, we compared enhanced dynamic wedge (EDW, Varian, Palo Alto, USA) profiles from calculated values in the radiation planning system with those from measurements of the MatriXX. Furthermore, anon-uniform IMRT dose fluence was tested. All the comparison studies have shown good agreements. In this study, the MatriXX was evaluated as a reliable dosimeter, and it could be used as a simplistic and convenient tool for radiotherapy qualify assurance.

  • PDF

Operation Efficiency Estimation of PET/CT Center by Work Form and Exposure Dose (근무형태 및 피폭선량에 따른 PET/CT실의 운영 효율성 평가)

  • Kweon, Oh-Jin;Jung, Su-Hee;Baek, Seung-Chan;Kim, Kyeong-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.93-97
    • /
    • 2009
  • Purpose: Recognize circulation work system and fixing work system's merits and demerits that is enforced in operation of PET/CT center in sudden increase recently. Wish to estimate connectivity degree of individual exposure dose and PET/CT working that is managed periodically through this and look for operation efficiency of PET/CT center. Materials and Methods: (1) Find interrelationship of length of service to be individual exposure dose and PET/CT through TLD interpretation. Specially, evaluate on the basis of data of 2.5 years until 2 quarters 2006~2008 year that show patient increase rapidly the latest. (2) Recognize what countermeasure is evaluating problems happened at circulation work system and fixing work system. Results: Patient examination's number was 14,674 items until 2 quarters 2006~2008 year, and the $^{18}F$-FDG average injection amount was 461.5 MBq. 2 people of 10 radiotechnologist did fixing work PET area and GAMMA area each, and 8 people did circulation work of 3 times for 2.5 years. Average exposure dose that PET area and Gamma area's circulation men in service receive was 1.32 mSv, and PET area men in services came out average 0.825 mSv high than Gamma area men in services. Nurse's exposure dose is 0.28 mSv, and next 2 reason is conjectured. One is contact with patient that medicate $^{18}F$-FDG injection, and another is consultation about patient's next time schedule after examination end. Although exposure dose's amount is not much, is expected to consider continuation work possibility by exposure dose in case is a nurse with pregnancy possibility. Also, $^{131}I$-isotope therapy area's radiotechnologist that use capsule appeared by 0.12 mSv and a nuclear medicine doctor appeared by exposure dose that is less of 0.11 mSv. Conclusions: In case do PET/CT center circulation work after a long time, connoted danger that most men in service is consecutiveness deficiency of business and individual exposure dose increase at early 1 month. Specially, way for individual exposure dose's decrease should be considered. Also, need to evaluate abhorrent work form for efficient work system introduction, and enforce circulation and fixing work suggestion suitable shift working. Finally, must make normalized business guide and so on to prevent circulation work people's business efficiency decline.

  • PDF

Usefulness of $^{18}F$-FDG PET/CT in Locoregional Recurrence of Differentiated Thyroid Cancer: Comparison PET/CT to PET and Neck Ultrasonography for Biopsy-proven Lesions (갑상선유두암 재발 진단에서 $^{18}F$-FDG PET/CT와 경부초음파검사 병용의 유용성: PET, 경부초음파검사 그리고 혈청 티로글로불린 (thyroglobulin)의 비교)

  • Kim, Kun-Ho;Shong, Min-Ho;Seo, Young-Duk;Kim, Seong-Min
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.411-420
    • /
    • 2009
  • Purpose: The aim of this study was to investigate the usefulness of $^{18}F$-FDG PET/CT with neck ultrasonography (neck US) in patients with recurrent, papillary thyroid cancer. Material and methods: This retrospective study (December 2006 to April 2008) enrolled sixty-one patients (ninety-one lesions) who underwent high-dose $^{131}I$-ablation therapy after total thyroidectomy, and evaluated recurred papillary thyroid cancer. All lesions were confirmed by histopathology and compared histopathologic findings to PET, PET/CT, and neck US findings. Results: In sixty-one patients (57 women, 4 men; age range, 24-81 years, mean 49 years; 61 papillary carcinomas), the sensitivity, specificity, accuracy of $^{18}F$-FDG PET/CT was 87.2%, 64.0%, 78.1% on a patient basis and 92.3%, 66.7%, 80.9% on a lesion basis, respectively. The sensitivity, specificity, accuracy of $^{18}F$-FDG PET was 71.8% (p=0.03), 59.0% (p=1.00), 67.2% (p=0.03) on a patient basis and 78.8% (p<0.01), 64.1% (p=1.00), 72.5% (p=0.02) on a lesion basis, respectively. The sensitivity, specificity, accuracy of neck US was 71.1% (p=0.07), 52.2% (p=0.75), 63.9% (p=0.05) on a patient basis and 71.2% (p<0.01), 61.5% (p=1.00), 67.0% (p=0.06) on a lesion basis, respectively. Combined $^{18}F$-FDG PET/CT with neck US improved the sensitivity, specificity, accuracy to 94.7% (p=0.50), 82.6% (p=0.13), 90.2% (p=0.03) on a patient basis and 96.2% (p=0.50), 89.7% (p<0.01), 93.4% (p<0.01) on a lesion basis, respectively. Conclusion: $^{18}F$-FDG PET/CT demonstrated significantly higher sensitivity than neck US for the detection of recurred papillary thyroid cancer lesions. Furthermore, combined $^{18}F$-FDG PET/CT with neck US showed more improved sensitivity, specificity, accuracy for diagnosis of recurrent papillary thyroid cancer.