• Title/Summary/Keyword: $\mu$-controller

Search Result 322, Processing Time 0.031 seconds

Cache Management using a Adaptive Parity Group Configuration in RAID 5 Controller (적응형 패리티 그룹 구성을 이용한 RAID 5 제어기에서의 캐시 운영)

  • Huh, Jung-Ho;Song, Ja-Young;Chang, Tae-Mu
    • The KIPS Transactions:PartA
    • /
    • v.10A no.2
    • /
    • pp.83-92
    • /
    • 2003
  • RAID 5 is a widely-used technique used to construct disk systems of high reliability and performance. This paper proposes APGOC (Adaptive Parity Group On Cache) organization on cache to solve "small write" problem of RAID 5 especially in OLTP (On-Line Transaction Processing System) environments. In our approach, when user process makes a request for a file to kernel, the information on the read/write characteristics is added to the file data structure of the file system. With this information, data and parity cache can be managed interchangeably through parity fetching. Therefore we can enhance the cache utilization and improve the disk request response time. Our method is analyzed and evaluated with a simulation method. Comparing with previous works, we observed about 6~l3% of performance enhancement.hancement.

Operatonal characteristics of the PLS linac vacuum system (PLS 선형가속기 진공계의 운전특성)

  • 김임경;박용정;김경렬;남궁원
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.4
    • /
    • pp.269-277
    • /
    • 1996
  • The vacuum systems of PLS linac provides average pressure of $2.6\times 10^{-6}$Pa under high power microwave of 54 MW peak with 4.1 $\mu \textrm s$ pulse width and 10 Hz repetition rates. The base pressure of system is$2.4\times 10^{-6}$Pa with 45$^{\circ}C$ cooling water. The outgassing rate of the system is decreased from $3.0\times 10^{-11}Torr-l/sec-\textrm{cm}^2$ at the initial stage after installation to $1\times 10^{-12}Torr-l/sec-\textrm{cm}^2$ at present. Total accumulated microwave energy dose is about 140 GJ per module. All ion pumps are working under saturated regime and effective pumping speeds of 60 I/s, 230 I/s ion pumps are 45 I/s, 65 I/s, 140 I/s under the operating range. Main problems occurred in recent year are troubles of ion pump controller and vacuum gauge controller, vacuum leak of energy doubler window and electron gun ceramic, and water leak in the dummy load of acceleraing columns. Total of 41 troubles with 140. 8 hours down time give good system availability of 98%. Down time can be reduced by high power waveguide valves and water dummy loads under development, and then availability is expected to be increased up to 99.5%.

  • PDF

Improvement of Katsuobushi smoking machine for the reduction of benzo(a)pyrene (가쓰오부시 훈연기 개선 및 벤조피렌 저감화)

  • Hong, Ju Hee;Hwang, Sang Min;Lee, Seung Ju
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.2
    • /
    • pp.162-167
    • /
    • 2017
  • A Katsuobushi smoking machine was developed and evaluated to determine its benzo(a)pyrene reducing effect. The machine was equipped with two heaters for smoking and chamber heating. The smoke-generating system was equipped with a cadmium sulfide (CdS) smoke sensor, an on/off controller, and a rotating feeder with a smoke inlet. Raw bonito was steamed and then smoked under three smoke levels. After smoking at $45^{\circ}C$ for 108 h, the benzo(a)pyrene concentrations were 5.87, 7.83, and $11.41{\mu}g/kg$ at the low, middle, and high smoke levels, respectively. The benzo(a)pyrene concentrations after low-level smoking at 45, 65, and $85^{\circ}C$ for 108 h were 5.87, 4.82, and $3.27{\mu}g/kg$, respectively. Accordingly, the optimal conditions for benzo(a)pyrene reduction were a lower smoke level and higher smoking temperature. These optimal smoking conditions can be implemented with the newly developed machine, but is not possible using a conventional Katsuobushi smoking machine.

KSTAR 연료주입계 Piezoelectric Valve 및 제어기 개발

  • Song, Jae-In;Kim, Yeong-Ok;Kim, Gwang-Pyo;Chu, Yong;Park, Gap-Rae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.205-205
    • /
    • 2012
  • Korea Superconducting Tokamak Advanced Research (KSTAR) 장치는 국내 유일의 초전도 자석을 이용한 핵융합 연구 장치로서 초고온의 플라즈마를 생성하여 차세대 에너지원인 핵융합 에너지를 획득하는 것을 목표로 두고 있다. 플라즈마를 생성부터 유지하기 위해서는 수소 동위원소를 토카막 내부로 공급해 주어야 하는데 이러한 수소동위원소를 "연료"라 부르며, 이 연료를 토카막 내부로 공급해 주는 시스템을 연료주입 시스템(Fueling System)이라고 한다. KSTAR에서는 토카막 내부로 고속의 연료 주입이 필요하고 정밀한 양의 연료를 공급하는 밸브를 사용하여야 하며, 이러한 밸브를 제어 할 수 있는 제어기를 필요로 한다. 위의 사항에 적합한 피에조 밸브(Piezoelectric Valve)는 2 msec 이내의 개폐시간과 500 Torr ${\ell}$/s 이상의 유량을 흘려줄 수 있는 피에조 밸브로 압전소자에 가해지는 전압(0~250 V)에 따라 변위의 양에 비례하여 연료가 진공용기 내로 유입된다. 압전소자의 변위는 최대 140 ${\mu}m$로 최적화되어 있어야 하며, 정전용량(Capacitance)는 30~40 nF이어야 한다. 또한 소자에 힘(Force)를 가해 최대 7 N으로 136 ${\mu}m$의 변위를 가진 소자를 사용해야 한다. 피에조 밸브의 특성으로는 아날로그 신호로 작동이 되어야 하며, 유량신호를 피드백하여 밸브의 구동 전압을 정밀하게 제어 되어야 한다. 피드백 제어를 위해 압력센서는 XCS-190 Series를 사용하여 낮은 유량에서도 민감하게 반응하도록 제작하였으며, 고전압이 유기 되었을 때 제어기를 보호하기 위한 정션박스를 설치하였다. 밸브 제어기는 피에조 밸브의 개방 속도를 높이기 위해 밸브 구동 전압을 순간적으로 높이는 POP 전압을 생성하는 기능과 유량 신호를 피드백해서 밸브 구동 전압을 정밀 제어 하는 기능을 가지고 있다. 제어장치는 아날로그 및 디지털 제어회로의 전원용 +15 V DC와 밸브 구동용 +250 V DC 출력용의 전원 공급 장치(Power supply unit), 펄스 및 트리거 신호를 생성하는 Master Programmer unit), Pop 전압과 피드백의 중요한 기능을 수행하는 Valve controller unit로 제작 되었다. 피에조 밸브와 제어기는 상호 작용하여 동작을 원활히 할 수 있도록 특성 실험을 진행하여야 하며, 진공상태에서 Lack의 유무를 확인하여야 한다. 현재 개발 제작된 밸브의 진공누설시험 및 특성실험을 진행하고 있으며, KSTAR 5차 캠페인에 적용할 계획이다.

  • PDF

A Low Cost Instruction Set for Bit Stream Process (비트열 처리를 위한 저비용 명령어 세트)

  • Ham, Dong-Hyeon;Lee, Hyoung-Pyo;Lee, Yong-Surk
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.45 no.2
    • /
    • pp.41-47
    • /
    • 2008
  • Most of media compression CODECs adopts the variable length coding method. This paper proposes special registers and instruction set for bit stream process in order to accelerate the decoding process of the variable length code. The instruction set shares the conventional data path to minimize additional costs. And bit stream is read from the memory instead of the special port. Therefore the instruction set minimizes the change of the processor, and is adopted without any additional input controller and buffer, and accelerate decoding process of variable length code. The data path of the instruction set needs additional 65 bits memory and 344 equivalent gates, 0.19 ns delay under TSMC $0.25{\mu}m$ technology. The instruction set reduced the execution time of the variable length code decoding process in H.264/AVC by about 55%.

A study on the peristaltic waveform of valveless PZT pump using disk type multi PZTs (다수 개 디스크 PZT 를 이용한 밸브리스 압전펌프의 연동구동 파형에 관한 연구)

  • Ham Y.B.;Park J.H.;Yun D.H.;Kim H.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1824-1827
    • /
    • 2005
  • For application to micro fluid control systems such as ${\mu}TAS$ (Micro Total Analysis Systems) and DDS (Drug Delivery Systems), it is very significant to handle precise and minute flow rates with low pressure pulsation. In this study, a novel valveless piezoelectric pump using peristaltic motion with three disk type PZT actuators is presented. The newly devised pump with an effective size of $70mm{\times}60mm{\times}55mm$ has three actuator layers connected in series from inlet to outlet. The PZT actuator has a maximum displacement of 240 ${\mu}m$ and a maximum force of 1.6 N. When the driving voltage for PZT actuators is sequentially applied with a certain phase shift, the pumping is performed by peristaltic motion of liquid volume. The working fluid is shut off without the driving voltage. Three methods for sequential driving are proposed and experimentally investigated. First and second methods utilize an intermittent sinusoidal waveform with phase shift of $90{\circ}\;and\;120^{\circ}$, respectively. Third method uses a rectangular waveform with phase shift of $90^{\circ}$. A controller with multi-phase shifter is designed and fabricated. Then, frequency and voltage-flow rate characteristics and load pressure-flow rate characteristics are experimentally investigated to verify the validity of the developed pump.

  • PDF

400mA Current-Mode DC-DC Converter for Mobile Multimedia Application (휴대용 멀티미디어 기기를 위한 400mA급 전류 방식 DC-DC 컨버터)

  • Heo, Dong-Hun;Nam, Hyun-Seok;Lee, Min-Woo;Ahn, Young-Kook;Roh, Jeong-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.8
    • /
    • pp.24-31
    • /
    • 2008
  • Power converters are becoming an essential block in modem mobile multimedia application. This paper presents a high performance DC-DC buck converter for mobile applications. Controller of DC-DC buck converter is designed by current-mode control method. An current-mode DC-DC converter is implemented in a standard $0.18{\mu}m$ CMOS process, and the overall die size was $1.2mm^2$. The peak efficiency was 86 % with a switching frequency of $1\sim1.5MHz$ and a maximum load current of 400mA.

A 4×32-Channel Neural Recording System for Deep Brain Stimulation Systems

  • Kim, Susie;Na, Seung-In;Yang, Youngtae;Kim, Hyunjong;Kim, Taehoon;Cho, Jun Soo;Kim, Jinhyung;Chang, Jin Woo;Kim, Suhwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.129-140
    • /
    • 2017
  • In this paper, a $4{\times}32$-channel neural recording system capable of acquiring neural signals is introduced. Four 32-channel neural recording ICs, complex programmable logic devices (CPLDs), a micro controller unit (MCU) with USB interface, and a PC are used. Each neural recording IC, implemented in $0.18{\mu}m$ CMOS technology, includes 32 channels of analog front-ends (AFEs), a 32-to-1 analog multiplexer, and an analog-to-digital converter (ADC). The mid-band gain of the AFE is adjustable in four steps, and have a tunable bandwidth. The AFE has a mid-band gain of 54.5 dB to 65.7 dB and a bandwidth of 35.3 Hz to 5.8 kHz. The high-pass cutoff frequency of the AFE varies from 18.6 Hz to 154.7 Hz. The input-referred noise (IRN) of the AFE is $10.2{\mu}V_{rms}$. A high-resolution, low-power ADC with a high conversion speed achieves a signal-to-noise and distortion ratio (SNDR) of 50.63 dB and a spurious-free dynamic range (SFDR) of 63.88 dB, at a sampling-rate of 2.5 MS/s. The effectiveness of our neural recording system is validated in in-vivo recording of the primary somatosensory cortex of a rat.

Lamination of Dielectric Layers by High Pressure Spray Coating for LTCC (고압 스프레이 코팅법에 의한 저온동시소성세라믹(LTCC) 유전체 층의 적층방법)

  • Lee, Jee-Hee;Kim, Young-Jin
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.3 s.40
    • /
    • pp.33-38
    • /
    • 2006
  • Aerosol slurry composed of dielectric materials, distilled water, and deflocculants was sprayed on the substrates, through a high-pressure spray gun as an aerosol. The coated layers were cofired together with $Al_{2}O_{3}$ substrates and green sheets on which the inner connectors were printed. Although the coating rate of coated layers strongly depended on slurry viscosity, spray shape, and the pressure of the spray gun, the coated density was not changed. Buried conductors were maintained as printed by high pressure spray coating method, because the pressing process was not used. At the optimum condition of air controller step 3-4 and slurry viscosity c.p 2000-4000, dense and uniform layers could be achieved. Comparing with conventional lamination process using green sheets, spray coating method enabled thin dielectric layers of $20{\sim}50{\mu}m$.

  • PDF

Measurement System of Photosynthetic Photon Flux Distribution and Illumination Efficiency of LED Lamps for Plant Growth

  • Lee, Jae Su;Kim, Yong Hyeon
    • Journal of Biosystems Engineering
    • /
    • v.37 no.5
    • /
    • pp.314-318
    • /
    • 2012
  • Purpose: This study was conducted to develop a measurement system for determining photosynthetic photon flux (PPF) distribution and illumination efficiency of LED lamps. Methods: The system was composed of a linear moving sensor part (LMSP), a rotating part to turn the LMSP, a body assembly to support the rotating part, and a motor controller. The average PPF of the LED lamp with natural cooling and water cooling was evaluated using the measurement system. Results: The PPF of LED lamp with water cooling was 3.1-31.7% greater than that with natural cooling. Based on the measured value, PPF on the horizontal surface was predicted. Illumination efficiency of the LED lamp was slightly increased with water cooling by 3.4%, compared with natural cooling. A simulation program using MATLAB was developed to analyze the effects of the vertical distance from lighting sources to growing bed, lamp spacing, and number of LED lamps, on the PPF distribution on the horizontal surface. The uniformity of the PPF distribution of the LED lamps was fairly improved with 15 cm spacing, as compared to the 5 cm spacing. By simulation, PPF of $217.0{\pm}27.9{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ was obtained at the vertical distance of 40 cm from six LED lamps with 12 cm spacing. This simulated PPF was compared to the measured one of $225.9{\pm}25.6{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. After continuous lighting of 346 days, the relative PPF of LED lamps with water cooling and natural cooling was decreased by 6.6% and 22.8%, respectively. Conclusions: From these results, it was concluded that the measurement system developed in this study was useful for determining PPF and illumination efficiency of artificial lighting sources including LED lamp.