• 제목/요약/키워드: $\gamma$-measurements

Search Result 321, Processing Time 0.024 seconds

Chelation of Calcium Ions by Poly(${\gamma}$-Glutamic Acid) from Bacillus subtilis (Chungkookjang)

  • Tsujimoto, Takashi;Kimura, Junya;Takeuchi, Yasushi;Uyama, Hiroshi;Park, Chung;Sung, Moon-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.10
    • /
    • pp.1436-1439
    • /
    • 2010
  • Many studies have clarified that poly(${\gamma}$-glutamic acid) (PGA) increases the solubility of $Ca^{2+}$, suggesting that PGA enhances calcium absorption in the small intestine. However, there has been no report on the specific interaction between PGA and $Ca^{2+}$ in water. We studied the aqueous solution properties of PGA calcium salt (PGA-Ca complex). The chelating ability and binding strength of PGA for $Ca^{2+}$ were evaluated. The PGA-Ca complex was soluble in water, in contrast to the insolubility of poly(acrylic acid) (PAA) calcium salt, and the chelating ability of PGA for $Ca^{2+}$ was almost the same as that of PAA. The globular conformation of the PGA-Ca complex in water was estimated by SEC and viscosity measurements. The chelation ability of PGA for $Ca^{2+}$ was examined by $^1H$ NMR. The present study showing the characteristics of the PGA-Ca complex will provide useful information about the calcium absorption by PGA in vivo.

International Comparison of Absolute Activity Measurement of $^{133}Ba$ Solution ($^{133}Ba$ 용액의 방사능 절대측정의 국제비교)

  • Park, Tae-Soon;Oh, Pil-Jae;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.2
    • /
    • pp.130-136
    • /
    • 1985
  • The activity measurement of a solution of $^{133}Ba$ which is an electron capture nuclide was carried out by the ${\beta}-{\gamma}$ coincidence method. The counting rates at the ${\beta}-,\;{\gamma}-$, and coincidence-channels were measured using a $4{\pi}$ proportional counter and two NaI(Tl) scintillation detectors. The specific activity of the solution calculated by the efficiency extrapolation was $(1151.01{\pm}2.99)kBqg^{-1}$ at the reference time(00h UT, 03-15-84). According to an international comparison of activity measurements organized by the Bureau International des Poids et Mesures, this result showed the difference of 0.94% to the mean value derived from the comparison.

  • PDF

Basic characterization of uranium by high-resolution gamma spectroscopy

  • Choi, Hee-Dong;Kim, Junhyuck
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.929-936
    • /
    • 2018
  • A basic characterization of uranium samples was performed using gamma- and X-ray spectroscopy. The studied uranium samples were eight types of certified reference materials with $^{235}U$ enrichments in the range of 1-97%, and the measurements were performed over 24 h using a high-resolution and high-purity planar germanium detector. A general peak analysis of the spectrum and the $XK_{\alpha}$ region of the uranium spectra was carried out by using HyperGam and HyperGam-U, respectively. The standard reference sources were used to calibrate the spectroscopy system. To obtain the absolute detection efficiency, an effective solid angle code, EXVol, was run for each sample. Hence, the peak activities and isotopic activities were determined, and then, the total U content and $^{234}U$, $^{235}U$, and $^{238}U$ isotopic contents were determined and compared with those of the certified reference values. A new method to determine the model age based on the ratio of the activities of $^{223}Ra$ and $^{235}U$ in the sample was studied, and the model age was compared with the known true age. In summary, the present study developed a method for basic characterization of uranium samples by nondestructive gamma-ray spectrometry in 24 h and to obtain information on the sample age.

Graft Polymerization of Acrylic Acid onto nylon 6

  • Park, Jae ho;Lee, Chong-Kwang
    • Nuclear Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.159-168
    • /
    • 1976
  • Acrylic acid has been grafted onto nylon fabric with ceric salts and ${\gamma}$-rays from Co-60 as initiators. The distribution of molecular weight of the grafted polyacrylic acid has been determined and it was found that the ratio of weight-average and number-average molecular weight was higher in room temp. than in low temp. (-184$^{\circ}C$). The weight-average molecular weight of the polyacrylic acid was calculated from viscosity measurements in sodium hydroxide solution. The factors affecting graft polymerization of acrylic acid onto nylon were examined. A possible mechanism that the oxidation of nylon probably takes place at the methylene group attached to nitrogen to give a free-radical was discussed.

  • PDF

Variation of Insulation Characteristics due to ${\gamma}$-ray Irradiation on LDPE Contained Treeing Inhibitors (트리억제제가 첨가된 LDPE의 방사선 조사에 따른 절연특성 변화)

  • Ryu, Boo-Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.2
    • /
    • pp.13-19
    • /
    • 2012
  • The effectiveness of treeing resistance in low density polyethylene containing azocompounds were investigated under radiation environments. 4-(4-nitrophenylazo)-1-naphthol and 4-(4-nitrophenylazo) resorcinol were selected for treeing inhibitors. LDPE containing the additives were crosslinked with dicumyl peroxide, irradiated by $Co^{60}$ ${\gamma}$-ray in the presence of air at room temperature. Treeing inception voltage, AC breakdown strength measurements were carried out for electrical insulation characteristics, thermoluminescence and gel contents were analyzed as various irradiation doses also. LDPE with treeing inhibitors showed much better insulation characteristics than pure LDPE. It is interpreted that molecular structures, polar groups and the type of radicals connected on the benzene ring of the additives affected electrical characteristics. From the results, 4-(4-nitrophenylazo) resorcinol was the most effective upon the best treeing and radiation resistance.

Deformation Behavior and Reinforcement Design of a Tunnel Excavated in Weak Rock by the NATM (연약암반에 굴착되는 NATM 터널의 변형거동과 보강설계)

  • 서영호;이정인
    • Tunnel and Underground Space
    • /
    • v.3 no.2
    • /
    • pp.132-141
    • /
    • 1993
  • Laboratory and field tests were performed to find out the effectiveness of ground improvement by grouting for an urban subway tunnel that was excavated in weak rock by the NATM. Field measurements were carried out to monitor the behavior of rock mass around the tunnel and to ensure the validity of the current design of the distance form the measuring points to the tunnel face. The final converged displacement and the peroid were predicted using the gamma function. It was found that the ground improvement in terms of reduced permeability and increased stength in the self-supportability of the excavation face enabled the NATM applied in poor gorund. As the result of applying the gamma function to the predicting of displacement, the final displacement including the preceding one and the converged period could be approximately predicted at the early excavation stage.

  • PDF

A Fault Isolation Filter Design Using Left Eigenstructure Assignment Scheme

  • Choi, Jae-Weon;Lee, Shi-Bok;Lee, Dae-Young;Park, Un-Sik;Suh, Young-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.583-589
    • /
    • 2000
  • This paper presents a novel fault isolation filter design method using left eigenstructure assignment scheme proposed by the first author et al. The proposed method shows good performance of fault isolation with an exact eigenstructure assignment and guarantees that the corrupted ${\gamma}$ faults can be isolated simultaneously when the number of available output measurements are equal to or larger than (${\gamma}+1$). A numerical example for the fault isolation filter is also included.

  • PDF

Determination of Thyroid Secretion Rate in Rabbit (토끼의 갑상선 측정)

  • 이종진;윤세중
    • The Korean Journal of Zoology
    • /
    • v.3 no.1
    • /
    • pp.19-23
    • /
    • 1960
  • A method for determination of thyroid secretion rate in rabbit by means of radioactive iodine presented. After injection of radioactive iodine, in vivo determination so f radioactivity in thyroid gland were made during a 19 day-experimental period. In the same period blood samples were drawn and analyzed for protein-bound iodine (PBI) and for protein-bound radioactive iodine(PBI181). A rate constant for secretion of thyroid hormone was calculated from the disappearance rate of radioactive iodine in thyroid gland. The secretion rate of radioactive hormone iodine was calculated by multiplying this rate constant by the amount of radioactive iodine present in thyroid gland. Assuming that the specific radioactiveness of the circulating thyroid hormone and of the hormone just secreted were identical , thyroid secretion rate was calculated by the equation. {{{{ { Secreted hormone-iodine , gamma /hr} over { Secreted hormone-I^131, % dose/hr }= { PBI, ${\gamma}$/ml.Serum} over { PBI^131 , % dose/ml . Serum } }} The method presented consisted of measurements for series of independent criteria on thyroid function, and the resulting thyroid secretion rate was calculated by combination of those.

  • PDF

Magnetic Properties and Cation Distribution of Phosphorous-Doped $Co-{\gamma}-{Fe_2} {O_3}$ Particles

  • Na, J.G.;Han, D.H.
    • Journal of Magnetics
    • /
    • v.1 no.1
    • /
    • pp.51-54
    • /
    • 1996
  • The effects of additional P-doping on the magnetic properties, thermal stability and cation distribution of Co-doped ${\gamma}-{Fe_2} {O_3}$have been investigated by means of magnetic annealing and measurements with vibration sample magnetometer and torque magnetometer. It is found that the P-doping promotes the coercivity and its magnetic-thermal stability, which may be attributed to increase of the cubic magneto-crystalline anisotropy constant, $K_1$ and the activation energy, E, for cation rearrangement, respectively. The cation distribution of P and Co-substituted iron oxide was calculated from the variation of the saturation magnetization with P-doping on the basis of the Neel model. It was found that the most of P ions in the iron oxides occupied the B-site of spinel lattice.

  • PDF

Exposure Measurements of Co-60 Gamma rays (Co-60 감마선의 조사선량 측정)

  • Hah, Suck-Ho;Kim, Hyun-Moon
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.7-16
    • /
    • 1991
  • Measurement of Co-60 gamma rays has been made for establishment of exposure standard and analyze it's overall uncertainties. Exposure rate determined by the charge mode method using vibrating reed amplifier with cylinderical type cavity chamber. The values of a variety of physical constants and the correction factors are evaluated. The resulting exposure rate is 690.81 R/h at the distance of 1m from the source and the related uncertainties is ${\pm}0.8%$

  • PDF