• Title/Summary/Keyword: $\180^{\circ}$

Search Result 2,128, Processing Time 0.028 seconds

Optimal Flip Angle for T2-Weighted Effect in Micro 4.7T MRI SE Sequence (마이크로 4.7T MRI SE Sequence에서 T2강조효과를 위한 최적의 Flip Angle)

  • Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.2
    • /
    • pp.113-117
    • /
    • 2019
  • The purpose of this study was to investigate the FA value which can produce the best T2-weighted images by measuring the signal intensity and noise according to the FA value change in the brain image and the abdominal image of the mouse using micro-MRI. Brain imaging and abdominal imaging of BALB / C mice weighing 20g were performed using 4.7T (Bruker BioSpin MRI GmbH) micro-MRI equipment, Turbo RARE-T2 (spin echo-T2) images were scanned at TR 3500 msec and TE 36 msec. The changes of the FA values were $60^{\circ}$, $80^{\circ}$, $100^{\circ}$, $120^{\circ}$, $140^{\circ}$, $160^{\circ}$ and $180^{\circ}$. We measured signal intensity according to FA values of ventricle and thalamus in brain imaging, The signal intensity of kidney and muscle around the kidney was measured in abdominal images. To obtain SNR and CNR, we measured the background signals of two different parts, not the tissue. In the brain (thalamus) image, the signal intensity of FA $100^{\circ}$ was 7,433 and SNR (6.49) was the highest. In the abdominal (kidney) image, the signal intensity was highest at 16,523 when FA was $120^{\circ}$, and the highest SNR was 8.54 when FA was $140^{\circ}$. The CNR value of the brain image was 1.38 at FA $60^{\circ}$ and gradually increased to 8.29 at FA $180^{\circ}$. The CNR value of the muscle adjacent to the kidney gradually increased from 2.36 when the FA value was $60^{\circ}$ and the highest value was 4,57 at the FA value $180^{\circ}$.

Diffraction of electromagnetic waves by a dielectric wedge of the angle larger than $180^{\circ}$ ($180^{\circ}$ 이상의 쇄기각을 갖는 쇄기형 유전체에 의한 전자파의 회절)

  • Kim, Se-Yun;Na, Jeong-Ung;Sin, Sang-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 1986.07a
    • /
    • pp.591-594
    • /
    • 1986
  • An asymptotic solution of electro-magnetic waves diffracted by a dielectric wedge of the angle larger than $180^{\circ}$ is obtained in case of the incidence of a E-polarized plane wave. Based on the dual integral equation in the spectral domain, physical optics approximation is supplemented by correction currents distributed along the interfaces. Those currents are expanded in a series of Bessel functions, known as Neumann's expansion of which fractional order is chosen to satisfy the static edge condition as the limiting value of dynamic case. Numerical results of edge diffraction patterns and field patterns are presented for some typical cases.

  • PDF

Kinetic energy of Laminar Steady flows in the Exit Reguon Connected to the straight Square-sectionnal $180^{\circ}$ curved Duct by using PIV (PIV 계측에 의한 $180^{\circ}$곡관 출구에 연결된 직관에서 층류정상유동의 운동에너지)

  • Lee J.G.;Lee H.G.;Sohn H.C.;Lee H.N.;Park G.M.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.521-524
    • /
    • 2002
  • In the present study, kinetic energy of laminar steady flow in the exit region connected to the square-sectional $180^{\circ}$curved duct was investigated experimentally. The experimental study for air flows was conducted to measure kinetic energy distributions by using the Particle Image Velocimetry(PIV) system with the data acquisition and processing system of Cactus 2000 software. The results obtained from experimental studies are summarized as follows : (1) The critical Reynolds number for a change from laminar steady flow to transitional steadt flow was about 1910, in the 50 region of dimensionless axial position (x/Dh) whirh was considered as a fully developed flow region. (2) Maximum kinetic energy of laminar steady flow was gradually increased as the Reynolds number increased.

  • PDF

Numerical Study on the Turbulent Flow in the $180^\circ$ Bends increasing Cross-sectional Aspect Ratio (단면의 폭이 증가하는 $180^\circ$ 곡덕트 내 난류유동의 수치해석적 연구)

  • 김원갑;김철수;최영돈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.804-810
    • /
    • 2004
  • This paper reports the characteristics of the three dimensional turbulent flow by numerical method in the 180 degree bends with increasing cross-sectional area. Calculated pressure and velocity, Reynolds stress distributions are compared to the experimental data. Turbulence model employed are low Reynolds number $textsc{k}$-$\varepsilon$ model and algebraic stress model(ASM). The results show that the main vortex generated from the inlet part of the bend maintained to outlet of the bend and vortices are continually developed at the inner wall region. The distribution of turbulent kinetic energy along the bend are increase up to 120$^{\circ}$ because of increment of cross-sectional area. Secondary flow strength of the flow is lower about 60% than that of square duct flow.

Lipid Oxidation in Roasted fish Meat III. Changes in Heme Compounds in Roasted and/or Reheated Dark Muscled Fish (어육의 배소에 의한 지질산화에 관한 연구 III. 적색육어의 배소 및 재가열에 의한 heme 화합물의 변화)

  • CHO Ho-Sung;LEE Kang-Ho;JOO Dong-Sik;KIM Gyeong-Eup;LIM Sang-Sun;LEE Jong-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.4
    • /
    • pp.483-488
    • /
    • 1998
  • In order to elucidate the effect of heme compounds on lipid oxidation in roasted and/or reheated mackerel and pacific saury, changes in myoglobin, metmyoglobin, total iron, nonheme iron and heme iron content were measured. Throughout the steps of roasting, heating and reheating, myoglobin content was decteased more rapidly roasted at $180^{\circ}C$ for 20 min in fillet samples than those roasted at $200^{\circ}C$ for 15 min or $220^{\circ}C$ for 10 min. When the skinless samples were roasted at $180^{\circ}C$ for 20 min, about $38\%$ of myoglobin in raw meat were remained. The skinless fillet roasted at the lower temperature resulted the higher level of metmyoglobin due to the reduced myoglobin. Regardless of roasted temperature and time, total iron content was retained the level of raw meat throughout processing. 2 times of nonheme iron content was noted in the skinless fillet samples roasted at $180^{\circ}C$ for 20 min. All samples, heme iron content was decreased much lower by roasted temperature and in absence of skin on fillet. It was decreased about $33\%$ when roasted at $180^{\circ}C$ for 20 min in the skinless fillet in case of pacific saury.

  • PDF

Changes in the Lipid Components of Edible Oil (Sunflower Seed Oil) under Storage Conditions (식용유(食用油)(해바라기)의 저장후건(貯藏候件)에 따른 지질성분(脂質成分)의 변화(變化))

  • Hwang, Joo-Ho;Yoon, Hyung-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.10 no.1
    • /
    • pp.17-25
    • /
    • 1981
  • The purpose of this study was to determine effects of thermal oxidation according to heating time and temperature, using sunflower oil from seed grown in Korea. To investigate these effects, the lipid components, fatty acid compositions, and chemical characteristics of crude oil from sunflower seed were determined. The content of nonpolar and polar in total lipids was 94.1% and 5.9%, respectively. The fatty acid compositions in the total lipids showed 6.21% palmitic, 4.50% stearic, 59.84% oleci and 29.48% linoleic acid. The concent of linoleic acid decreased during heating. However, the concent of oleic, palmitic and stearic acid increased during heating. The components of neutral lipid were found 6 fractions, including triglyceride, diglyceride and free fatty acid. The content of triglyceride decreased but diglyceride and monoglyceride increased during heating. The content of free fatty acid increased during the continuous heating period for 32 hours at $100^{\circ}C$, whereas decreased in 16 hours at $180^{\circ}C$. Iodine value decreased during heating, and peroxide value increased during the continuous heating period for 32 hours at $100^{\circ}C$, whereas decreased in 16 hours at $180^{\circ}C$.

  • PDF

Study on the Second Moment Turbulence Model in a Square Sectioned $180^{\circ}$ Bend (정사각단면을 갖는 $180^{\circ}$ 곡관내의 2차 모멘트 난류모형에 관한 연구)

  • 김명호;염성현;최영돈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1203-1217
    • /
    • 1994
  • In the present study, in order to analyze a turbulent flow in a square sectiond 180.deg. bend, Kim's low Reynolds number second moment turbulence closure is adopted. In this model, turbulence model constants in the wall region are modified as functions of turbulent Reynolds number by use of near wall turbulent universal properties based on Laufer's experimental results of Reynolds stress distriburions. Algebraic stress model and Reynolds stress equation model are used to verify the low Reynolds number second moment closure. The application of the present low Reynolds number algebraic stress model to the prediction of a square sectioned 180.deg. bend flow gives improved velocities and Reynolds stresses profiles compared with those obtained by using the van Driest mixing length model and present low Reynolds number Reynolds stress equation model.

An Experimental Study on Forced Convective Heat Transfer in a Rectangular Duct with $180^{\circ}$ Bend (직사각형단면을 갖는 $180^{\circ}$곡관에서의 강제 대류 열전달 특성에 관한 실험적 연구)

  • Moon, C.;Lee, G.H.;Choi, Y.D.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.2
    • /
    • pp.290-301
    • /
    • 1992
  • An experimental study has been performed to investigate the characteristics of forced convective heat transfer in a rectangular duct with a 180.deg. bend. The Nusselt number of outer wall has maximum value near 105.deg. at which secondary flow is most active and the Nusselt number of inner wall has maximum value near the inlet of a duct. Near the outlet of a duct, the Nusselt number of outer wall decreases, the Nusselt number of inner wall increases and so those access each other through the influence of a straight duct attached to the end of a duct with a 180.deg. bend. Results of this experimental study would be the fundamental data when streamline curvature correction models are developed in the numerical study for forced convective heat transfer in a curved duct.

Evaluation of the thermal stability and estimation of the lifetime of PAG and POE oil (PAG 및 POE 오일의 열안정성 평가 및 수명 예측)

  • Park, Keun-Seo;Park, Kyoung-Kuhn;Kim, Seok-Hyeon;Kang, Byung-Ha
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.386-391
    • /
    • 2005
  • An experimental study was conducted to analyze the thermal stability and to estimate the lifetime of refrigerating lubricants. PAG and POE oil are considered as a test fluids in this study. The viscosity of PAG and POE oil was measured by the vibration type viscometer while temperature is varied periodically in the range of $0^{\circ}C{\sim}100^{\circ}C$. The results indicate that the reduction rates of viscosity of PAG and POE oil were less than 5% after 510 cycles. In order to estimate lifetime of PAG and POE oil with temperature, the viscosity was measured while the temperature of oils was maintained at 180, 200 and $220^{\circ}C$. It is found that the lifetimes of PAG oil were shown to be 244, 177 and 89 hours at the temperature of 180, 200 and $220^{\circ}C$, respectively. Also the lifetimes of POE oil were estimated to be 1,744, 1,007 and 334 hours at the temperature of 180, 200 and $220^{\circ}C$, respectively. The lifetime correlations of PAG and POE oil are suggested in this paper.

  • PDF

A Size-Reduced CPW Balun with the Wilkinson Divider Structure Using a Crossing Structure (신호-접지 교차구조를 이용한 소형화된 CPW 월킨슨 분배기 구조의 발룬)

  • Lim Jong-Sik;Yang Hoe-Sung;Kim Dong-Joo;Jeong Yong-Chae;Ahn Dal;Kim Kwang-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.8 s.99
    • /
    • pp.835-841
    • /
    • 2005
  • In this paper, a novel sized-reduced CPW(Coplanar Waveguide) balun is proposed. It has a crossing structure between signal line and ground planes of CPW transmission line for the $180^{\circ}$ phase inversion. The$3{\lambda}/4$ CPW transmission line is reduced to ${\lambda}/4$ in physical length while the electrical length is preserved to $270^{\circ}$ by the $180^{\circ}$ phase inverting structure, while the previous balun by Lim et at. has a long $3{\lambda}/4$ transmission section to from the Wilkinson divider structure having out of phase between output ports. In addition, the measured data which show the crossing structure has the wanted $180^{\circ}$ phase change is presented in this work.