• Title/Summary/Keyword: $[^{18}F]F_2$

Search Result 3,009, Processing Time 0.026 seconds

Re-evaluation of [18F]fluorobenzaldehyde as a prosthetic group

  • Choe, Yearn Seong
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.2
    • /
    • pp.75-79
    • /
    • 2015
  • [$^{18}F$]Fluorobenzaldehyde, which is a versatile radioactive prosthetic group, can undergo reduction, reductive amination, or oxidation to be used for synthesis of diverse radiotracers. This review covers synthesis of [$^{18}F$]fluorobenzaldehyde and its conversion to secondary prosthetic groups, and also highlights its application to the development of radiotracers.

Accuracy of F-18 FDG PET/CT in Preoperative Assessment of Cervical Lymph Nodes in Head and Neck Squamous Cell Cancer: Comparison with CT/MRI (두경부 편평상피암 환자에서 수술 전 경부림프절 전이 평가에 대한 F-18 FDG PET/CT의 정확도: CT/MRI와의 비교)

  • Choi, Seung-Jin;Byun, Sung-Su;Park, Sun-Won;Kim, Young-Mo;Hyun, In-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.309-315
    • /
    • 2006
  • Purpose: Accurate evaluation of cervical lymph node (LN) metastasis of head and neck squamous cell canter (SCC) is important to treatment planning. We evaluated the diagnostic accuracy of F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for the detection of cervical LN metastasis of head and neck SCC and performed a retrospective comparison with CT/MRI findings. Materials & Methods: Seventeen patients with pathologically proven head and neck SCC underwent F-18 FDG PET/CT and CT/MRI within 4 week before surgery. We recorded lymph node metastases according to the neck level system of imaging-based nodal classification. F-18 FDG PET/CT images were analyzed visually for assessment of regional tracer uptake in LN. We analyzed the differences in sensitivity and specificity between F-18 FDG PET/CT and CT/MRI using the Chi-square test. Results: Among the 17 patients, a total of 123 LN levels were dissected, 29 of which showed metastatic involvement. The sensitivity and specificity of F-18 FDG PET/CT for detecting cervical LN metastasis on a level-by-level basis were 69% (20/29) and 99% (93/94). The sensitivity and specificity of CT/MRI were 62% (18/29) and 96% (90/94). There was no significant difference in diagnostic accuracy between F-18 FDG PET/CT and CT/MRI. Interestingly, F-18 FDG PET/CT detected double primary tumor (hepatocellular carcinoma) and rib metastasis, respectively. Conclusion: There was not statistically significant difference of diagnostic accuracy between F-18 FDG PET/CT and CT/MRI for the detection of cervical LN metastasis of head and neck SCC. The low sensitivity of F-18 FDG PET/CT was due to limited resolution for small metastatic deposits.

Difference in F-18 FDG Uptake According to the Patterns of CT-Based Diagnosed Pulmonary Lymphangitic Carcinomatosis in Patients with Lung Cancer (폐암환자에 있어 CT상으로 진단된 폐림프관성암종증의 형태에 따른 F-18 FDG 섭취의 차이)

  • Jun, Sung-Min;Kim, Yong-Ki;Kim, In-Ju;Kim, Seong-Jang;Nam, Hyun-Yeol;Kim, Bum-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.292-300
    • /
    • 2008
  • Purpose: Our purpose was to evaluate F-18 FDG uptake in pulmonary lymphangitic carcinomatosis (PLC) according to CT findings and histology of lung cancer. Materials and Methods: Thirty-three lung cancer patients with PLC were enrolled in this retrospective study. All the patients had a CT-based diagnosis of PLC. Chest CT findings of PLC were classified on the basis of involvement of axial interstitium. We categorized the involvement of axial interstitium as group 1, and the involvement of peripheral interstitium only as group 2. Visual and semiquantitative analyses by F-18 FDG PET/CT were performed in the PLC lesions. At first, we analyzed the F-18 FDG uptake in the PLC by visual assessment. If abnormal uptake was seen in the PLC, we drew regions of interest in the PLC lesions to obtain the maximum SUVs (maxSUVs). Results: Of the 33 patients, 22 had abnormal F-18 FDG uptake in the visual assessment. There was no significant difference in the frequency of abnormal F-18 FDG uptake between group 1 and group 2 (p=0.17), although the frequency of group 1 tended to be higher than group 2 (15/19 (78.9%) in group 1, 7/14 (50.0%) in group 2). However, group 1 had a higher maxSUV than group 2 (p<0.01, group 1: $2.9{\pm}1.4$, group 2: $1.5{\pm}0.6$). There was no significant difference in the frequency of abnormal F-18 FDG uptake and maxSUV among the histology of the lung cancers. Conclusion: The involvement of axial interstitium in the PLC by lung cancer has a higher maxSUV than the involvement of only peripheral interstitium.

Radiolysis Assessment of $^{18}F$-FDG According to Automatic Synthesis Module (자동합성장치에 따른 $^{18}F$-FDG의 방사선분해 평가)

  • Kim, Si-Hwal;Kim, Dong-Il;Chi, Yong-Gi;Choi, Sung-Wook;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.8-11
    • /
    • 2012
  • Purpose : Among quality control items, the radiochemical impurity must be below 10% of total radioactivity. In this regard, as the recently commercialized automatic synthesis module produces a large amount of 18F-FDG, radiolysis of radiopharmaceuticals is very likely to occur. Thus, this study compared the changes in radiochemical purity regarding radiolysis of $^{18}F$-FDG according to automatic synthesis module. Materials and methods : Cyclotron (PETtrace, GE Healthcare) was used to produce $^{18}F$ and automatic synthesis module (FASTlab, Tracerlab MX, GE Healthcare) was used to achieve synthesis into FDG. For radiochemical purity, Radio-TLC Scanner (AR 2000, Bioscan), GC (Gas Chromatograph, Agilent 7890A) was used to measure the content of ethanol included in $^{18}F$-FDG. Glass board applied with silica gel ($1{\times}10cm$) was used for stationary phase while a mixed liquid formed of acetonitrile and water (ratio 19:1) was used for mobile phase. High-concentration and low-concentration $^{18}F$-FDG were produced in each synthesis module and the radiochemical purity was measured every 2 hours. Results : The purity in low-concentration (below 2.59 GBq/mL) was measured as 99.26%, 98.69%, 98.25%, 98.09% in Tracerlab MX and as 99.09%, 97.83%, 96.89%, 96.62% in FASTlab according to 0, 2, 4, 6 hours changes, respectively. The purity in high-concentration (above 3.7 GBq/mL) was measured as 99.54%, 96.08%, 93.77%, 92.54% in Tracerlab MX and as 99.53%, 95.65%, 92.39%, 89.82% in FASTlab according to 0, 2, 4, 6 hours changes, respectively. Also, ethanol was not detected in GC of $^{18}F$-FDG produced in FASTlab, while 100~300 ppm ethanol was detected in Tracerlab MX. Conclusion : Whereas the change of radiochemical purity was only 3% in low-concentration $^{18}F$-FDG, the change was rapidly increased to 10% in high-concentration. Also, higher radiolysis were observed in $^{18}F$-FDG produced in FASTlab than Tracerlab MX. This is because ethanol is included in the synthesis stage of Tracerlab MX but not in the synthesis stage of FASTlab. Thus, radiolysis is influenced by radioactivity concentration than the inclusion of ethanol, which is the radioprotector. Therefore, after producing high-concentration $^{18}F$-FDG, the content must be diluted through saline to lower concentration.

  • PDF

Clinical Application of 11C-Acetate Positron Emission Tomography-Computed Tomography (PET-CT) in Patients of Urinary System Cancer (비뇨기암 환자에서 11C-Acetate 양전자 방출 컴퓨터 단층 검사 (PET-CT)의 임상 적용)

  • Nam-Koong, Hyuk;Ham, Joon chul;Kim, Sang kyoo;Choi, Yong hoon;Lim, Han sang;Kim, Jae sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.9-13
    • /
    • 2016
  • Purpose PET-CT examinations using $^{18}F-FDG$ to treat urinary system cancer are limited in terms of anatomical structure and excretion route of $^{18}F-FDG$. But one of the ongoing examinations utilizing $^{11}C-Acetate$ can compensate for such defects. We would like to introduce a clinical application of $^{11}C-Acetate$ PET-CT in urinary cancer patients. Materials and Methods We conducted a clinical survey of 22 patients diagnosed with urinary cancer at our hospital, 10 prostate cancer patients, 10 renal cell carcinoma patients, and 2 bladder cancer patients. All patients were performed $^{18}F-FDG$ PET-CT examinations, $^{11}C-Acetate$ examinations were performed after two weeks on average. The equipment used to D-710 PET-CT in GE Company and we performed PET-CT procedures 15 minutes after injecting $^{11}C-Acetate$, and a medical doctor from the department of nuclear medicine appraised and compared images between $^{18}F-FDG$ and $^{11}C-Acetate$. Results According to our survey, prostate cancer patients generally had lower uptake of $^{18}F-FDG$ than other cancer patients did. In 2 out of 10 prostate cancer patients, metastasized cancer showed greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. In renal cell carcinoma cases, 8 out of 10 patients displayed evidently greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. We excluded bladder cancer cases in this study because uptake of $^{18}F-FDG$ in the bladder was too hot, the number of patients was insufficient, and the cases did not meet criteria such as the use of diuretics. Conclusion It is too premature to draw solid conclusions from the survey, since it involved only a small number of participants. However, there are a number of studies conducted abroad that prove the effectiveness of the $^{11}C-Acetate$ PET-CT examinations in treating urinary system cancer, and this study is still ongoing at our hospital. If the tests were to be conducted on a larger number of participants, this study could lead to numerous other potential research topics, such as the correlation between Prostatic specific antigen (PSA) values and $^{11}C-Acetate$ PET-CT, Gleason sum values from biopsy before surgery, Specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) between $^{18}F-FDG$ PET-CT examinations and $^{11}C-Acetate$ PET-CT examinations in other urinary system cancers.

  • PDF

Usefulness of $^{18}F$-FDG Fusion PET for Diagnosing an Early Stage Cancer (조기 암 진단을 위한 $^{18}F$-FDG Fusion PET의 유용성)

  • Jeon, Jae-Hwan;Kim, Byeong-Jin;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.145-149
    • /
    • 2010
  • Purpose: Recently, $^{18}F$-FDG Fusion PET which has a high sensitivity for diagnosing cancer is being used for purpose of health examination. This study is to demonstrate that $^{18}F$-FDG fusion PET study is useful for diagnosing an early stage cancer. Materials and Methods: This research has been conducted with 2790 patients visited Seoul National University Hospital Healthcare System (SNUHHS) for $^{18}F$-FDG fusion PET study for a health examination from February, 2004 to December 2008. PET/CT images were acquired from skull base to femur after 1 hour from injecting $^{18}F$-FDG 0.14 mCi/kg to the patients. GEMINI GS (Philips, Netherlands) was used for scanning. Results: From February 2004 to December 2008, $^{18}F$-FDG Fusion PET study was performed for 99,009 patients among all patients who visited SNUHHS and 2,790 patients was performed. Diagnostic rate for malignant cancer was 0.95% for the patients who were not examined by $^{18}F$-FDG Fusion PET study. 1.94% was for the patients who were. The rate of malignant tumor was showed 10% and benign tumor was 90% among 542 patients who showed abnormality in the PET/CT images. Types and rates of malignant tumor showed thyroid cancer: 31.5%, lung cancer: 14.8%, stomach cancer: 9.3%, rectum cancer: 3.7%, breast cancer: 3.7%, metastasis cancer: 16.7%. Nonspecific lymph node in the mediastinum, physiologic uptake in the colon, diffuse mild hypermetabolism in bilateral thyroid gland were shown as a benign tumor. Conclusion: The diagnostic rate of malignant tumor with $^{18}F$-FDG Fusion PET for a purpose of health examination was relatively higher than general medical examination. Consequently, it is superior and useful for applying $^{18}F$-FDG Fusion PET study for health examination.

  • PDF

Evaluation of PET Image for Fluorine-18 and Gallium-68 using Phantom in PET/CT (PET/CT에서 Phantom을 이용한 Fluorine-18, Gallium-68 방사성 핵종의 PET 영상 평가)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.321-327
    • /
    • 2018
  • The purpose of this study is to compare PET imaging performance with Fluorine-18 ($^{18}F$) and Gallium-68 ($^{68}Ga$) for influence of physical properties of PET tracer. Measurement were performed on a Siemens Biograph mCT64 PET/CT scanner using NEMA IEC body phantom and Flangeless Esser PET phantom containing filled with $^{18}F$ and $^{68}Ga$. Emission scan duration(ESD) was set to 1, 2, 3, 4 and 5min/bed for $^{68}Ga$ and 1min/bed for $^{18}F$. The PET image were evaluated in terms of contrast, spatial resolution. Under same condition, The percentage of contrast recovery measured in the phantom ranged from 16.88% to 72.56% for $^{68}Ga$ and from 27.51% to 74.43% for $^{18}F$ and The FWHM value to evaluate spatial resolution was 10.96 mm for $^{68}Ga$ and 9.19 mm for $^{18}F$. For this study, $^{18}F$ produces better image contrast and spatial resolution than $^{68}Ga$ due to higher positron yield and lower positron energy ($^{18}F$: 96.86%, 633.5 keV, $^{68}Ga$: 88.9%, 1899 keV), The physical properties of PET tracer effect on the PET image. $^{68}Ga$ image applying ESD of 3, 4, 5min/bed were showed similar to $^{18}F$ image with ESD of 1min/bed. This study suggests that increasing ESD for acquiring $^{68}Ga$ PET image seem to be similar to $^{18}F$ image.

$^{18}F$-FDG PET/CT in Patients with Initially Diagnosed Adenoid Cystic Carcinoma of the Head and Neck: Clinicoplathologic Correlation (처음 진단된 두경부 선양낭성암종에서 $^{18}F$-FDG PET/CT: 임상상 및 병리소견과의 상관성)

  • Lee, Ji-Young;Choi, Joon-Young;Ko, Young-Hyeh;Baek, Chung-Hwan;Son, Young-Ik;Cho, Suk-Kyong;Cheon, Mi-Ju;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.395-401
    • /
    • 2009
  • Purpose: We evaluated $^{18}F$-FDG PET/CT findings in initially diagnosed adenoid cystic carcinoma (ACC) of the head and neck in association with pathological subtype, staging, uptake comparison with squamous cell carcinoma (SqCC) and prognosis. Materials and Methods: The subjects were 16 patients with initially diagnosed ACC of head and neck who underwent pretreatment $^{18}F$-FDG PET/CT. Histological subtype (solid pattern vs. tubular/cribriform pattern), $SUV_{max}$ of size-matched SqCC of the head and neck as control group, disease-free survival (DFS) were compared with the $SUV_{max}$ of ACC of the head and neck. Results: Of total 16 patients, 6 had solid pattern and the remaining 10 had tubular/cribriform pattern. The $SUV_{max}$ were significantly higher in solid pattern group than in tubular/cribriform pattern group ($6.7{\pm}3.2$ vs. $4.2{\pm}0.9$, p=0.03). PET/CT found unexpected distant metastasis in 18.7% of patients (3/16) and changed the therapeutic plan in those patients. The $SUV_{max}$ of ACC was significantly lower than that of size-matched SqCC ($5.1{\pm}2.4$ vs. $13.6{\pm}6.0$, p<0.001). DFS was not significantly different according to the histological subtype. In contrast, patients with high $^{18}F$-FDG uptake ($SUV_{max}$ ${\geq}$6.0) had significantly shorter DFS than those with low $^{18}F$-FDG uptake ($SUV_{max}$ <6.0). Conclusion: $^{18}F$-FDG uptake of ACC of the head and neck is significantly associated with histological subtype and DFS. $^{18}F$-FDG PET/CT may be useful for detecting unexpected metastasis. Since $^{18}F$-FDG uptake of tubular/cribriform ACC compared with SqCC is relatively low, it is necessary to interpret PET images carefully in patients without alleged ACC.

Changes in Brain Activity of Rats due to Exposure to Fine Dust Using 18F-FDG PET (18F-FDG PET를 이용한 미세먼지 노출에 따른 쥐(rat)의 뇌 활성도 변화)

  • Cho, Yun-Ho;Cho, Kyu-Sang;Lee, Wang-Hui;Choi, Jea-Ho
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.225-232
    • /
    • 2022
  • Fine dust threatens human health in various forms, depending on the particle size, such as by causing respiratory, cardiovascular, and brain diseases, after entering the body via the lungs. The aim of this study was to correlate fine dust exposure with changes in brain blood flow in Sprague Dawley rats by using micro-positron emission tomography and elucidate the possibility of developing cerebrovascular diseases caused by fine dust. The subjects were exposured to an average fine dust (particulate matter 2.5) of 206.2 ± 7.74 to ten rats four times a day, twice a day for 90 min. Before the experiment, they were maintained at NPO to the maximize the intake of 18F-fluorodeoxy glucose(18F-FDG) and minimize changes in the 18F-FDG biomass depending on the ambient environment and body temperature of the rats. PET images were acquired in the list mode 40 min after injecting 18F-FDG 44.4 MBq into the rats tail vein using a micro-PET scanner pre and post exposure to fine dust. We found that the whole brain level of 18F-FDG standardized uptake value in rats averaged 5.21 ± 0.52 g/mL pre and 4.22 ± 0.48 g/mL post exposure to fine dust, resulting in a statistically significant difference. Fine dust was able to alter brain activity after entering the body via the lungs in various forms depending on the particle size.