• Title/Summary/Keyword: $[^{18}F]F_2$

Search Result 3,009, Processing Time 0.033 seconds

Performance improvements of organic solar cell using dual cathode buffer layers

  • Sachdeva, Sheenam;Kaur, Jagdish;Sharma, Kriti;Tripathi, S.K.
    • Current Applied Physics
    • /
    • v.18 no.12
    • /
    • pp.1592-1599
    • /
    • 2018
  • The present study deals with the effect of dual cathode buffer layer (CBL) on the performance of bilayer of 4,4'-cyclohexylidenebis[N,N-bis(4-methylphenyl)benzenamine] (TAPC) and fullerene (C70)-based organic solar cell (OSC) with low donor concentration. OSC devices with CBLs have been fabricated using thermal vapor deposition technique. We report the use of lithium fluoride (LiF) and molybdenum trioxide ($MoO_3$) as CBLs. The insertion of LiF between C70 and aluminium (Al) electrode enhances the power conversion efficiency (PCE) of device from 1.89% to 2.47% but quenching of photogenerated excitons is observed at interface of C70 and LiF layers. Incorporation of $MoO_3$ between LiF and Al electrode further enhances PCE of device to 3.51%. This has also improved the material quality and device properties, by preventing the formation of gap states and diminishing exciton quenching.

STABILITY OF QUADRATIC FUNCTIONAL EQUATIONS IN RANDOM NORMED SPACES

  • Schin, Seung Won;Ki, DoHyeong;Chang, JaeWon;Kim, Min June;Park, Choonkil
    • Korean Journal of Mathematics
    • /
    • v.18 no.4
    • /
    • pp.395-407
    • /
    • 2010
  • In this paper, we prove the generalized Hyers-Ulam stability of the following quadratic functional equations $$cf\(\sum_{i=1}^{n}x_i\)+\sum_{j=2}^{n}f\(\sum_{i=1}^{n}x_i-(n+c-1)x_j\)\\=(n+c-1)\(f(x_1)+c\sum_{i=2}^{n}f(x_i)+\sum_{i<j,j=3}^{n}\(\sum_{i=2}^{n-1}f(x_i-x_j\)\),\\Q\(\sum_{i=1}^{n}d_ix_i\)+\sum_{1{\leq}i<j{\leq}n}d_id_jQ(x_i-x_j)=\(\sum_{i=1}^{n}d_i\)\(\sum_{i=1}^{n}d_iQ(x_i)\)$$ in random normed spaces.

Ionospheric Behaviors Over Korea Peninsula During the Super Geomagnetic Storm Using GPS Measurements (GPS 관측자료에 나타난 초대형 지자기 폭풍 기간 동안 한반도 상공 전리층 양상)

  • Chung, Jong-Kyun;Choi, Byung-Kyu;Baek, Jung-Ho;Jee, Geon-Hwa;Cho, Jung-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.4
    • /
    • pp.467-478
    • /
    • 2009
  • The super-geomagnetic storms called 2003 Halloween event globally occurred during the period of 29 through 31 which are the following days when the solar flares of X18 class exploded on 28 October 2003. The S4 index from GPS signal strength and the peak electron density ($NmF_2$) from GPS tomography method are analyzed according to the date. The occurrences of the cycle slip and scintillation in the GPS signals are 1,094 and 1,387 on 28 and 29 October, respectively and these values are higher than 604 and 897 on 30 and 31 October. These mean the ionospheric disturbances are not always generated by the period of geomagnetic storm. Therefore, GPS S4 index is useful to monitor the ionospheric disturbances. Behaviors of ionospheric electron density estimated from GPS tomography method are analyzed with the date. At UT = 18 hr, the maximum $NmF_2$ is shown on 28 October. It agrees with $NmF_2$ variation measured from Anyang ionosonde, and the GPS signal are better condition on 30 and 31 October than 28 October. In conclusion, GPS signal condition is relation with geomagnetic activities, and depend upon the variation of the electron density. We will study the long-term data to examine the relationship between the GPS signal quality and the electron density as the further works.

Pilot Study for the Prediction of Response to Radiotherapy Using [$^{18}F$]Fluorothymidine PET in Nasopharyngeal Cancer: Comparison with [$^{18}F$]FDG PET (비인두암에서 [$^{18}F$]Fluorothymidine PET을 이용한 방사선치료 반응도 예측을 위한 예비 연구: [$^{18}F$]FDG PET와의 비교)

  • Baek, So-Ra;Chae, Sun-Young;Kim, Hye-Ok;Lee, sang-Wook;Oh, Seung-Jun;Im, Ki-Chun;Moon, Dae-Hyuk;Kim, Jae-Seung;Ryu, Jin-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.535-542
    • /
    • 2009
  • Purpose: This study was performed to know whether [$^{18}F$]Fluorothymidine (FLT) positron emission tomography (PET) can be used to monitor early response to radiotherapy in comparison with [$^{18}F$]Fluorodeoxyglucose (FDG) PET, and to establish the optimal imaging time for prediction of therapy response. Materials and Methods: Two patients with nasopharyngeal cancer underwent serial FLT PET and FDG PET before and during radiotherapy. Three on-treatment FLT and FDG PET scans were performed on 1 week, 2 weeks and 3 weeks (at each time of 10 Gy, 20 Gy and 30 Gy delivered). The peak standardized uptake values ($SUV_{peak}$) of primary tumors were measured on FLT and FDG PET. Then, percent changes of $SUV_{peak}$ after therapy were calculated. Results: In two patients, baseline values of $SUV_{peak}$ on FDT PET were higher than those on FLT PET (FLT vs FDG; 3.7 vs 5.0, and 5.7 vs 15.0). In patient 1, FLT $SUV_{peak}$ showed 78%, 78% and 84% of decrease on 1 week, 2 and 3 weeks after treatment, whereas FDG $SUV_{peak}$ showed 18%, 52% and 66% of decrease, respectively. In patient 2, FLT $SUV_{peak}$ showed 75%, 75% and 68% of decrease, whereas FDG $SUV_{peak}$ showed 51%, 49% and 58% of decrease, respectively. Both patients reached to complete remission after radiotherapy. Conclusion: After radiotherapy, the decrease of FLT tumor uptake preceded the decrease of FDG tumor uptake in patients with nasopharyngeal cancer, and 1 week after therapy may be appropriate time for the assessment of early response. FLT PET might be more useful than FDG PET for monitoring early response to radiotherapy.

A Study on Exposure Among Asbestos Textile Workers and Estimation of their Historical Exposures (석면방직업 근로자의 석면노출 실태와 과거농도 추정에 관한 연구)

  • Park, Jeong Im;Yoon, Chung Sik;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.16-39
    • /
    • 1995
  • From July 8 to September 2 1994, asbestos exposure level among asbestos textile workers was surveyed. Six plants out of plants in Korea were selected for this study. In addition to the exposure level, the relationship between the level of exposure and some factors affecting exposure were studied. Also, using historical data of asbestos concentrations in asbestos textile plants plus current data, trend of asbestos exposure level could be introduced. Historical exposure level was estimated on the basis of these data. The main results of this study are follows. 1. Average concentration of all six plants surveyed was 1.54 f/cc, and range of those concentrations was 0.03 - 11.58 f/cc. The minimum average concentration was 0.32 f/cc and the maximum was 8.04 f/cc which is four times higher than the Korean standard. A wide difference of exposure level among the workers of different plants was observed. In three plants, the half of all the plants surveyed, their average concentrations exceeded the Korean standard, and those in all the plants exceeded the ACGIH TLV. 2. Among total 56 samples, 22 samples(39%) were in excess of the Korean standard, and 53 samples(95%) were above the ACGIH TLV. Among 32 personal samples, 15 samples(47%) exceeded the Korean standard, and 30 samples(94%) exceeded the ACGIH TLV. Among 24 area samples excluding a few samples collected in office area, seven samples exceeded the Korean standard, and 23 samples( 96%) exceeded the ACGIH TLV. 3. Distributions of concentrations were observed by processes. In weaving, the highest, average concentration was 4.29 f/cc, and range was 2.61 - 11.58 f/cc. In spinning, average concentration was 2.22 f/cc, and range was 0.41 - 8.93 f/cc. In carding, average concentration was 1.98 f/cc, and range was 0.23 - 10.93 f/cc, In twisting, average concentration was 1.65 f/cc, and range was 0.21 - 9.83 f/cc. In mixing, the lowest, average concentration was 0.48 f/cc, and range was 0.22 - 1.20 f/cc. 4. All the samples from basic processes of asbestos textile plants were above the ACGIH TLV. Nineteen samples(45%) out of all these 42 samples exceeded Korean standard. Fourteen samples(58%) of total 24 personal samples, and five samples(28%) of total 18 area samples exceeded the Korean standard. Considering processes, all the samples in weaving process exceeded the Korean standard and 50 did 54% of those in spinning, 40% in carding, and 27% in twisting. 5. Trend of decreasing asbestos concentrations in asbestos textile plants was observed by time. 6. Asbestos concentrations in asbestos textile plant in 1975 were estimated to be 11.0 - 92.4 f/cc.

  • PDF

Health Promotion Lifestyle Profiles of the Korean Elderly in Japan (일본에 거주하는 한국 노인의 건강증진 생활양식)

  • Jaung, Ae-Hwa;Park, Kyung-Min;Ryu, Mi-Kyung
    • Research in Community and Public Health Nursing
    • /
    • v.11 no.2
    • /
    • pp.470-485
    • /
    • 2000
  • The purpose of this study was to investigate health promotion lifestyle profiles of the Korean elderly in Japan. The subjects of this study were 202 elders in Aichi prefecture. The method of this study questionnaires interviews, and a self-administered questionnaire from the 1st to the 20th of April in 2000. This study tool was based on Walker et al. (1987)'s Health Promotion lifestyle Profiles (HPLP). Analysis of the data used an SPSS/pc+ WIN 9.0 program. Data analyses were conducted by using frequency, percentage, t-test, ANOVA. Pearson correlation, Kendal tau and Stepwise Multiple Regression. The results were as follows: 1. The average score of Health Promotion Lifestyle Profiles of Korean elderly in Japan was 2.72(SD=0.40). On the sub-scale of Health Promotion Lifestyle Profiles: nutrition(M = 3. 06), self-actualization(M =2.99), interpersonal support (M=2.81), stress management (M=2.68) revealed higher scores, whereas the scores of health responsibility(M=2.52), and exercise(M=1.92) were lower. 2. Health Promotion Lifestyle Profiles were significantly different by age (F = 11. 02, p = .000), religion(F=2.96, p=.033), occupation(F=6.91, p=.000), living family status(F=13.07, p=.000), living family number(F=11.74, p=.000), monthly pocket money(F=18.79, p=.000), the source of pocket money (F=7.18, p=.000), and the length of residence(F=9.79, p=.000). 3. Health Promotion Lifestyle Profiles was significantly predicted by monthly pocket money($r^2$ change =0. 188, p=.000), sex($r^2$ change= 0.066, p= .000), the length of residence($r^2$ change = 0.059, p = .000), the source of pocket money($r^2$ change=0.036, p= .000), age ($r^2$ change=0.018, p=.000). These variables showed a positive correlation with health promotion lifestyle profiles of the Korean elderly in Japan. These variables explained 36.7% of the variance of Health Promotion Lifestyle Profiles. On the basis of the above findings, Health Promotion Lifestyle Profiles programs for Korean elderly in Japan needs be to developed with Japanese social-culture perspectives and needs to develop an intervention method to improve Health Promotion Lifestyle Profiles. It is also suggested that further research is required.

  • PDF

Diagnostic Performance of Spin-Echo Echo-Planar Imaging Magnetic Resonance Elastography in 3T System for Noninvasive Assessment of Hepatic Fibrosis

  • Se Woo Kim;Jeong Min Lee;Sungeun Park;Ijin Joo;Jeong Hee Yoon;Won Chang;Haeryoung Kim
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.180-188
    • /
    • 2022
  • Objective: To validate the performance of 3T spin-echo echo-planar imaging (SE-EPI) magnetic resonance elastography (MRE) for staging hepatic fibrosis in a large population, using surgical specimens as the reference standard. Materials and Methods: This retrospective study initially included 310 adults (155 undergoing hepatic resection and 155 undergoing donor hepatectomy) with histopathologic results from surgical liver specimens. They underwent 3T SE-EPI MRE ≤ 3 months prior to surgery. Demographic findings, underlying liver disease, and hepatic fibrosis pathologic stage according to METAVIR were recorded. Liver stiffness (LS) was measured by two radiologists, and inter-reader reproducibility was evaluated using the intraclass correlation coefficient (ICC). The mean LS of each fibrosis stage (F0-F4) was calculated in total and for each etiologic subgroup. Comparisons among subgroups were performed using the Kruskal-Wallis test and Conover post-hoc test. The cutoff values for fibrosis staging were estimated using receiver operating characteristic (ROC) curve analysis. Results: Inter-reader reproducibility was excellent (ICC, 0.98; 95% confidence interval, 0.97-0.99). The mean LS values were 1.91, 2.41, 3.24, and 5.41 kPa in F0-F1 (n = 171), F2 (n = 26), F3 (n = 38), and F4 (n = 72), respectively. The discriminating cutoff values for diagnosing ≥ F2, ≥ F3, and F4 were 2.18, 2.71, and 3.15 kPa, respectively, with the ROC curve areas of 0.97-0.98 (sensitivity 91.2%-95.9%, specificity 90.7%-99.0%). The mean LS was significantly higher in patients with cirrhosis (F4) of nonviral causes, such as primary biliary cirrhosis (9.56 kPa) and alcoholic liver disease (7.17 kPa) than in those with hepatitis B or C cirrhosis (4.28 and 4.92 kPa, respectively). There were no statistically significant differences in LS among the different etiologic subgroups in the F0-F3 stages. Conclusion: The 3T SE-EPI MRE demonstrated high interobserver reproducibility, and our criteria for staging hepatic fibrosis showed high diagnostic performance. LS was significantly higher in patients with non-viral cirrhosis than in those with viral cirrhosis.

Evaluation of Physical Characteristics of Discovery ST scanner Using NEMA NU2-2001 Standard (NEMA NU2-2001을 이용한 PET-CT 스캐너의 물리적 특성평가)

  • Lee, Byeong-Il
    • Journal of Integrative Natural Science
    • /
    • v.1 no.2
    • /
    • pp.79-83
    • /
    • 2008
  • As a new standard for performance measurement, NEMA NU2-2001 was presented recently. In this study, I investigated the spatial resolution, sensitivity, scatter fraction, and noise equivalent count ratio (NECR) in order to know the information of physical characteristics and system performance of GE discovery ST using this new standard. Bismuth germinate crystals ($6{\times}6$ array, $6.3mm{\times}6.3mm{\times}30mm$) were used in discovery ST (energy window:375-650 keV, coincidence window:11.7 nsec). To measure the sensitivity, five aluminum sleeves (Data Spectrum Corp., Chapel Hill, NC., USA, thickness:1.25 mm)-NEMA sensitivity phantom- filled with F-18 solution were used. Successive measurements in 2D and 3D acquisition mode were made with a line source at the center of transaxial field of view and 10 cm off from the center until the count was over 500,000. Spatial resolution was estimated using a point source (F-18, 0.1 mCi) at different locations in the FOV. Scatter fraction and NECR was tested using a NEMA scatter phantom. Dynamic data were acquired for 7 half-lives using F-18 solution. And true to background ratio was averaged at last three frames when the random rate was as small as ignorable for the calculation of scatter fraction. We anticipate this overall evaluated results could be used for the quality assurance and optimized image acquisition for clinical research.

  • PDF