• Title/Summary/Keyword: "On-water"

Search Result 61,654, Processing Time 0.074 seconds

A Study on the Greenhouse Water Curtain System: Heat Transfer Characteristics

  • 손원명;한길영
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.E
    • /
    • pp.80-87
    • /
    • 1990
  • Energy balance equations Were developed to describe the heat transfer mechanisms in a double layer plastic greenhouse with a water curtain system. Heat transfer variables were determined by using various temperature data measured in a conventional prototype semicircular cross-section greenhouse over a range of water temperatures and water flow rates. The heat transfer coefficient between flowing water and greenhouse air was independent of water flow rates. But the heat transfer coefficient between water surface and the stagnant air space within the double plastic layer was dependent on water flow rates. Substituting the heat transfer coefficients, determined from the energy balance equations in the heat transfer equations, demonstrated various relationships among ambient air temperature, greenhouse air temperature, water temperature, and water flow rates. The heating benefits were linearly related to not only the inside and outside air temperatures but also to the water temperature. The energy conservation effects of the water curtain system were found even initial water temperatures were considerably lower than the greenhouse setting temperatures. Sensitivity analysis for heat transfer coefficients demonstrated that the heat transfer coefficient between greenhouse air and the stagnant air within the plastic layers was the most significant coefficient in the estimation of heating effects.

  • PDF

Exposure of Selected Chuncheon Residents to Trace Metals and Inorganic Anions in Drinking Water (춘천지역 일부 주민들의 먹는물 중 미량금속 및 무기 음이온에 대한 노출)

  • Kim, He-Kap;Song, Jin-A;Song, Byeong-Yeol
    • Environmental Analysis Health and Toxicology
    • /
    • v.24 no.4
    • /
    • pp.293-301
    • /
    • 2009
  • This study was conducted to investigate the distribution of the concentrations of selected trace metals and inorganic anions in five types of drinking water samples (mineral spring water, well water, small community water, municipal tap water, and commercial mineral water) collected from Chuncheon, Gangwon-do in 2007. Forty four samples were analyzed for five metals and five anions using an atomic absorption spectrometer and an ion chromatograph, respectively. Arsenic (As) and nitrate (${NO_3}^-$) concentrations in some groundwater samples did not meet the future (10 ${\mu}g/L$) and current (44 mg/L) Korean drinking water standards, respectively. On the other hand, any municipal tap water samples, the sources of which were lake surface water, satisfied the Korean standards. Human health risk assessment results showed that arsenic in all types of water, especially groundwater including commercial mineral water, may pose both noncarcinogenic and carcinogenic effects on the residents. It is concluded that groundwater is not safe drinking water any longer and that a national survey and follow-up measures need to be taken.

Evaluation of Water Quality Characteristics in the Nakdong River using Multivariate Analysis (다변량 통계분석을 이용한 낙동강 상수원수의 수질변화 특성 조사)

  • Kim, Gyungah;Kim, Yejin;Song, Mijeong;Ji, Keewon;Yu, Pyungjong;Kim, Changwon
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.814-821
    • /
    • 2007
  • This study was estimated water quality to raw water quality management of the Maeri intake station in the Nakdong River using Multivariate Analysis. The results of Principle Component Analysis was explained up to 76.9% of total water quality by three principle components. The 1st, 2nd was explained 44.7%, 17.9% and third was explained 14.3%. Also, the three factors was derived from Factor Analysis. The 1st factor was estimated as the matabolism and organic matter pattern related to algal growth. The 2nd factor was judged as the pollution of pattern related to the discharge from stream of the Nakdong River and 3rd factor was viewed as the hydrological variation pattern related to particle matter. The results of Cluster Analysis were classified into three groups.

Water-Temperature Prediction of Streams Entering into Imha Reservoir using Multi-Regnssion Method (다중회귀분석을 이용한 임하호 유입하천의 수온예측)

  • Yi, Yong-Kon;Lee, Sanguk;Koh, Deuk Koo
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.919-925
    • /
    • 2006
  • The regression models for the water temperatures of Ban Byeon Stream and Yong Jeon stream were developed using multi-regression method. It was also investigated that the applicability of the stream temperature prediction to two-dimensional numerical simulation to predict the vertical water temperature in Imha Reservoir. Air temperature and dew point as independent variables were selected to be applicable to cases with the different variation of flow rates. The data division of water temperature using a cutoff flow rate of $20m^3/s$ was found to reduce the prediction error of the stream temperature. The mean absolute percent error of the numerical simulation results of the vertical water temperature in Imha Reservoir using the regression models was 11%, which was only 4.3% lager than the simulation result using the measured stream temperature. Therefore, the regression models of the stream temperatures using multi-regression method applied in this study could be applied to predict the vertical water temperature in Imha Reservoir with a good accuracy.

Determining the Time of Least Water Use for the Major Water Usage Types in District Metered Areas (상수관망 블록의 대표적인 용수사용 유형에 대한 최소 용수사용 시간의 결정)

  • Park, Suwan;Jung, So-Yeon;Sahleh, Vahideh
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.3
    • /
    • pp.415-425
    • /
    • 2015
  • Aging water pipe networks hinder efficient management of important water service indices such as revenue water and leakage ratio due to pipe breakage and malfunctioning of pipe appurtenance. In order to control leakage in water pipe networks, various methods such as the minimum night flow analysis and sound waves method have been used. However, the accuracy and efficiency of detecting water leak by these methods need to be improved due to the increase of water consumption at night. In this study the Principal Component Analysis (PCA) technique was applied to the night water flow data of 426 days collected from a water distribution system in the interval of one hour. Based on the PCA technique, computational algorithms were developed to narrow the time windows for efficient execution of leak detection job. The algorithms were programmed on computer using the MATLAB. The presented techniques are expected to contribute to the efficient management of water pipe networks by providing more effective time windows for the detection of the anomaly of pipe network such as leak or abnormal demand.

Data Driven Approach to Forecast Water Turnover (데이터 탐색 기법 활용 전도현상 예측모형)

  • Kwon, Sehyug
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.3
    • /
    • pp.90-96
    • /
    • 2018
  • This paper proposed data driven techniques to forecast the time point of water management of the water reservoir without measuring manganese concentration with the empirical data as Juam Dam of years of 2015 and 2016. When the manganese concentration near the surface of water goes over the criteria of 0.3mg/l, the water management should be taken. But, it is economically inefficient to measure manganese concentration frequently and regularly. The water turnover by the difference of water temperature make manganese on the floor of water reservoir rise up to surface and increase the manganese concentration near the surface. Manganese concentration and water temperature from the surface to depth of 20m by 5m have been time plotted and exploratory analyzed to show that the water turnover could be used instead of measuring manganese concentration to know the time point of water management. Two models for forecasting the time point of water turnover were proposed and compared as follow: The regression model of CR20, the consistency ratio of water temperature, between the surface and the depth of 20m on the lagged variables of CR20 and the first lag variable of max temperature. And, the Box-Jenkins model of CR20 as ARIMA (2, 1, 2).

Curtailment of Water use Through the Integration of Process Waste Waters at the Standard Thermal Power Plant (표준화력발전소의 발전폐수 통합을 이용한 용수 사용량 절감)

  • Mun, Gyeong-Seok;Jang, Heui-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.437-443
    • /
    • 2006
  • The Water usage is relationship which is close with the administrative cost from industrial facility. It is not easy to reduce a water usage. This research is the optimization of the waste water quantity which process waste water integration of the standard thermal power plant in system operate time. The turbine rotates by force of the steam and it produces an electricity. Demineralization Water is manufacture purity manufacturing equipment and it is supplied in power plant channel. We knew a possibility of reducing from pure control process. When it is reduced the Back Washing time, Rinsing time of the gravity filter and the activated carbon filter. Also, It is possible even from regeneration phase in Condensate Polishing Demineralization System. In addition, There is also the water which the drain of the sampling water for watching the condition of power plant process will be able to use. Integrates these processes it will be able to reduce an annual 30,000 ton degree. The research is want to use the fundamental data for the water curtailment of the power plant.

Analysis of Runoff Characteristics in the Geum River Basin using Watershed Management Model (유역관리모형을 이용한 금강유역 유출특성 해석)

  • Ryoo, Kyong-Sik;Hwang, Man-Ha;Maeng, Seung-Jin;Lee, Sang-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.527-534
    • /
    • 2007
  • To operate scientifical and integrated management of water resources, it needs to identify clearly the quantitative variation and moving pathway of water resources in a basin. Moreover, it needs to also estimate more precisely the amount of runoff generating from the precipitation. Thus, in this study, to carry out more reliable hydrologic analyses, the runoff characteristics according to detailed runoff components and water balance in a basin are analyzed. As a result of yearly water balance analyses, during the period of drought year, the loss is bigger than that of 6-year mean loss and the return flow of groundwater is the most dominant component of runoff. During the period of flood year, the loss is smaller about 4% than that of 6-year mean loss and the subsurface water is the most dominant component of runoff. The loss due to the interception and evapotranspiration for 6-year mean loss is about 53% of the total rainfall, the mean runoff ratio is about 27% and the baseflow is about 22%.

An Experimental Study on the Condensation Characteristics of Sea Water in the Tilted Box with Solar Radiation (태양열을 받는 경사진 육면체 내 해수의 응축특성에 관한 실험적 연구)

  • Kim, Beom-Han;Kim, Byung-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.27-33
    • /
    • 2011
  • To find effective way of the production of distilled water for drought and flood with solar radiation, three boxes were made same base each 1000mm ${\times} $1000mm and tops are 45 degree. Individual boxes contained the sea water, rain water and surface water were placed at the same location and same time. Condensation of each box has been compared. On clear day production of distilled water in the box with sea water was 36% and 32% less than boxes with rain water and surface water. The maximum condensation reached when the temperature of the top and bottom parts are equal. As concentration of sea water increased production of distilled water was decreased. In the box with sea water, the surface temperature was lower than 3cm below the surface. Optimum collector area for producing distilled water 2000ml of these three boxes were $3.75m^2$

Effects of Particle Size of Dry Water on Fire Extinguishing Performance (드라이워터의 입자크기가 소화성능에 미치는 영향)

  • Lee, Eungwoo;Choi, Youngbo
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.28-35
    • /
    • 2019
  • Dry water is a core-shell structured powder which comprises a very fine water core covered with hydrophobic silica particles. Recently, the dry water has attracted attention as a new type of fire extinguishing agents. However, characteristics of the dry water as a fire extinguishing agent have not been revealed until now. To our best knowledge, this is the first work to uncover effects of particle size of the dry water on the fire extinguishing performance. Pristine dry water, which has heterogeneous particle size distribution, was carefully separated by sieving method into three fractions which were a small size (ca. $110{\mu}m$) fraction, a medium size (ca. $220{\mu}m$) fraction and a large size (ca. $400{\mu}m$) fraction. Microscopic observations confirmed the effective separation of dry water's particle size. In extinguishing tests of wood cribs fire, the medium size dry water showed most excellent fire extinguishing performance, as compared to other dry waters having small (ca. $110{\mu}m$) and large (ca. $400{\mu}m$) particle size. The good performance of the medium size (ca. $220{\mu}m$) dry water may be attributed to the balance between cooling effect of the water core and smothering effect of the silica particles. It is also revealed that small size dry water has poor flowability than large size dry water.