• Title/Summary/Keyword: "On-water"

Search Result 61,381, Processing Time 0.077 seconds

The Technology of Peak Demand Reduction using Automatic Water Tank Pumping System on the Apartment And Analysis of Effect of Energy Cost (아파트 고가수조 자동급수장치를 이용한 전력피크 감소 및 전력시장에서의 효과 분석)

  • Lee, Jae-Gul;Lee, Yun-Kyoung;Cho, Won-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.161-163
    • /
    • 2006
  • This paper introduce the technology of peak demand reduction using automatic water tank pumping system on the apartment. That systems on the apartments installed water tank can control pumping(electricity) demand. Generally, system peak demand is occurred at the same time on workday and many water pumps consume electric power randomly. At this point, shift of operating time of water pump can reduce peak demand using automatic water tank pumping system. We were operating this system on some apartments for test of effect of peak demand reduction. and we represent result of demand shift. This result suggests that spread of the automatic water pumping system can contribute to reduce system peak demand and reduce system operation cost.

  • PDF

A Speed-up method of document image binarization using water flow model (Water flow model을 이용한 문서영상 이진화의 속도 개선)

  • 오현화;이재용;김두식;장승익;임길택;진성일
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.393-396
    • /
    • 2003
  • This paper proposes a method to speed up the document image binarization using a water flow model. The proposed method extracts the region of interest (ROI) around characters from a document image and restricts pouring water onto a 3-dimensional terrain surface of an image only within the ROI. The amount of water to be filled into a local valley is determined automatically depending on its depth and slope. Then, the proposed method accumulates weighted water not only on the locally lowest position but also on its neighbors. Finally, the depth of each pond is adaptively thresholded for robust character segmentation. Experimental results on real document images shows that the proposed method has attained good binarization performance as well as remarkably reduced processing time compared with that of the existing method based on a water flow model.

  • PDF

Effect of Acidic Electrolyte Water on Growth and Infection of Phytophthora capsici (고추 역병균(Phytophthora capsici)의 발육과 감염에 미치는 산성전해수의 영향)

  • 이중환;권태룡;문재덕;이준탁
    • Korean Journal Plant Pathology
    • /
    • v.14 no.5
    • /
    • pp.440-444
    • /
    • 1998
  • This experiment was carried out to elucidate the effect of electrolytic water on the growth and infection of Phytophthora capsici. Zoospores of P. capsici did not grow on potato dextrose agar when the pathogen was cultured after suspended in electrolytifc water (pH 2.5, 3.0, 3,5) with HCI solution. When the 100 ml of electrolytic water (pH 2.5, 3.0, 3.5) was irrigated on the red pepper plants that had been inoculated by P. capsici (103 zoospores/ml), the red pepper plants were not infected but irrigated with sterilized water (pH 6.5) the red pepper plants were infected. With this result, it could be concluded that the good sterilization effect on P. capsici might be obtained by applying electrolytic water.

  • PDF

Model based control of filter run time on potable water treatment plant

  • Jusic, Suvada;Milasinovic, Zoran
    • Coupled systems mechanics
    • /
    • v.4 no.2
    • /
    • pp.157-172
    • /
    • 2015
  • Control of potable water treatment plant (PWTP) is nowadays based on experience. The aim of this article is to show that model based control of treatment process is more efficient than process operation based on experience. Stimela environment is used for modeling of processes of potable water treatment. Application of the model was conducted on PWTP "Crkvice" in Zenica (BiH). This plant has used conventional rapid sand filters. By effective application of the model it is determined the optimal filter run time for different input turbidity of raw water. This results in the possibility of reducing the consumption of backwashing water, lower costs for its pumping and reducing the amount of coagulants. In the existing practice, based on experience, these benefits are not used.

A Survey on the Envlronmcntal Sanitary Status of Water Supply System in Rural Area (농촌급수시설에 관한 환경위생확적 조사연구)

  • 박국환;김성자
    • Journal of Environmental Health Sciences
    • /
    • v.5 no.1
    • /
    • pp.76-85
    • /
    • 1978
  • This survey was undertaken for the period seven month beginning January 15, 1977 and ending July 31, 1977 to detect the general sanitary status of the villages and the villagers and, at the same time, analyse quality of water sources with emphasis on a total of 1,256 households dividing into three different groups: such as, 280 households were selected as random samples from the area of the sophisticated piped water supply system, 122 households from the area of the simplified water supply system and finally 854 households from the area of nonpi-ped water supply system. The following results were concluded after quality of water sources had been analysed and conditions of the environmental sanitation had been reviewed: 1. 11.2% of the respondents from the area of the sophisticated piped water supply system responded that quantity of drinking water lacked to meet their demand while 30.6% of the villagers from the area of nonpi-ped water supply system responded quantity of drinking water didn't meet their demand. 2. 30.8% of the.respondents from the area of the sophisticated water supply system responded that contaminating source located within 15 meters from the water source while 54.4% of the respondents from the non-piped water supply system claimed the same. 3. It was found that water from all sampling areas were positive in coliform group with exception of Moonsan which is one of the sophisticated piped water supply system groups and the number of general bacteria exceeded the government standard criteria of water quality in the area of the nonpi-ped water supply system. 4. In relation with time requirement to draw water in the area of non-piped water supply system, 76 respondents claimed it requires less than 15 minutes to draw water, 15.0% claimed 15 to 30 minutes and 9.0% claimed more than 30 minutes. 5. In relation with knowledge on sanitation of drinking water, 30.8% of respondents from the area of the sophisticated piped water supply system and 41.8% of respondents from the area of nonpiped water supply system denied possible existence of germ in drinking water they drink, while 17.4% of the respondents from the area of the sophisticated water supply system and 50.2% of non-peped water supply system thought it safe to drink water without any treatment. 6. 60.0% of the respondents from the area of non-piped water supply system and many of them believed that their health status will be improved by installation of a sophisticated water supply system in their area. 7. The respondents from the areas of piped water supply sytem expressed greater concern over drinking water sanitation than those from the areas of non-piped water supply system and sanitary conditions were found the same. It was, therefore, proved that knowledge of environmnntal sanitation contributed a great deal to improve sanitary conditions of the villages and villagers and at the same time health education, especially environmental sanitation, will be played a important role to improve their sanitary conditions.

  • PDF

A Study on the Method of Energy Evaluation in Water Supply Networks (상수관망의 에너지 평가기법에 관한 연구)

  • Kim, Seong-Won;Kim, Dohwan;Choi, Doo Yong;Kim, Juhwan
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.7
    • /
    • pp.745-754
    • /
    • 2013
  • The systematic analysis and evaluation of required energy in the processes of drinking water production and supply have attracted considerable interest considering the need to overcome electricity shortage and control greenhouse gas emissions. On the basis of a review of existing research results, a practical method is developed in this study for evaluating energy in water supply networks. The proposed method can be applied to real water supply systems. A model based on the proposed method is developed by combining the hydraulic analysis results that are obtained using the EPANET2 software with a mathematical energy model on the MATLAB platform. It is suggested that performance indicators can evaluate the inherent efficiency of water supply facilities as well as their operational efficiency depending on the pipeline layout, pipe condition, and leakage level. The developed model is validated by applying it to virtual and real water supply systems. It is expected that the management of electric power demand on the peak time of water supply and the planning of an energy-efficient water supply system can be effectively achieved by the optimal management of energy by the proposed method in this study.

A Study on Growth Characteristics of Water Tree in XLPE (가교폴리에틸렌의 수트리 성장특성에 관한 연구)

  • 김덕근;임장섭;김철운;류경우;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.346-349
    • /
    • 1997
  • It is well known that water treeing is one of the main cause of breakdown in underground power cables, but water tree is not easy to observe. This aging phenomenon was resulted in effect of water and electric field and so on. In this paper, Distilled water was used as water electrode to observe the water treeing in XLPE(cross-linked polyethylene). To observe easily, sample was made of pallet types so water tree was able to show by microscope. As a result, electrical tree appears at niddle electrode tip which was concentrated electric field, but water tree was shown up different types that were appealed in total area of water electrode as well as water electrode tip.

  • PDF

Establishment of calculation methodology and thermal analysis for the development of a water calorimeter

  • Kang, M.Y.;Kim, Junhyuck;Choi, H.D.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2620-2629
    • /
    • 2020
  • As an early stage in the development of a water calorimeter, this study established a computer simulation methodology for analyzing the thermal behavior of a water calorimeter based on radiation transport and energy deposition. As a result, this study developed a method wherein the energy deposition distribution, which is obtained by applying Monte Carlo methods in water calorimeters, is directly used as a heat source for the thermal analysis model. Based on the proposed method, heat transfer in a water vessel and the effect of thermistor self-heating were analyzed. Through an analysis of the water velocities with and without a water vessel, it was found that a water vessel can serve as a convection barrier. Furthermore, it was confirmed that when considering thermistor self-heating, the water temperature change at the thermistor location is 0.219 mK higher compared to that when the thermistor was not considered. Therefore, thermistor self-heating must be considered to analyze the thermal behavior of a water calorimeter more accurately.

Estimate Analysis on the Fluoride Work Management of Water Supply Conveyance (상수도수 불화사업 운영에 관한 평가분석)

  • Kim, Kap-Jin;Lee, Yang-Kyoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.17 no.4
    • /
    • pp.510-518
    • /
    • 2003
  • The fluoride work management of water supply conveyance has been recommending by the WHO to prevent of tooth decay. Fluoridation of public water supplies has been practiced since 1945. The present approximately 67 countries reported community water fluoridation benefiting many cities. At our country, Fluoridation began in 1981 in Chongiu and Jinhea. In 2002, approximately 40 cities have large populations consuming fluoridated water. But Chongiu stopped fluoridation water works. Few public health measures have been accorded greater clinical and laboratory research, epidemiological study, clinical trials, and public attention than has water fluoridation. In this study, chemical analysis of Sodium Silicofluoride and Fluoride Feed Equipment analyzed. And this study proposed to Fluoride concentration experimental (lab. and field exp.), economics analysis, prevention effect. This study can be decided on the concentration of fluoride injection in Water Fluoridation. Hereafter, this study will be useful in safety and economics of Water Fluoridation in the future.

Influence of fracture characters on flow distribution under different Reynold numbers

  • Wang, Jing;Li, Shu-Cai;Li, Li-Ping;Gao, Cheng-Lu
    • Geomechanics and Engineering
    • /
    • v.14 no.2
    • /
    • pp.187-193
    • /
    • 2018
  • Water inrush through the destruction of water resisting rock mass structure was divided into direct water inrush, key block water inrush and splitting water inrush. In the direct water inrush, the Reynolds numbers has a significant effect on the distribution of the water flow and vortex occurred in the large Reynolds numbers. The permeability coefficient of the fracture is much larger than the rock, and the difference is between 104 and 107 times. The traditional theory and methods are not considering the effect of inertia force. In the position of the cross fracture, the distribution of water flow can only be linearly distributed according to the fracture opening degree. With the increase of Reynolds number, the relationship between water flow distribution and fracture opening is studied by Semtex.