• Title/Summary/Keyword: "Journal of Architectural History"

Search Result 1,342, Processing Time 0.025 seconds

Seismic Performance Evaluation of a School Gymnasium Using Static Anlysis (정적해석에 의한 학교 체육관의 내진 성능 평가)

  • Morooka, Shigehiro;Tsuda, Seita;Ohsaki, Makoto
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.4
    • /
    • pp.49-59
    • /
    • 2009
  • The seismic responses of small-scale spatial frames such as school gymnasiums are usually evaluated using static analysis, although time-history analysis should be carried out to fully incorporate the dynamic responses of the structures against seismic motions. In this study, advanced static analysis procedures arc presented for school gymnasiums that will improve the performance evaluation against seismic motions. The seismic loads are approximated by equivalent static loads corresponding to the two performance levels; i.e., Levels 1 and 2 defined by the Japanese building standard. The importance of utilizing the eigenmode in the load pattern is discussed. Simple static analysis procedures are presented for evaluation of maximum vertical acceleration. It is shown that the static analysis for Level 2 input significantly underestimates the responses by dynamic analysis; however, the inelastic responses for Level 2 are shown to be successfully evaluated using the equivalent linearization that is similar to the $^{\circ}$Dmethod based on calculation of limit strength$^{\circ}{\pm}$ for building frames in Japan.

  • PDF

A Study on the Validation of Measured Data from the Seismic Accelerometers in the Safety Evaluation System of Public Buildings (공공건축물 안전성 평가를 위한 지진가속도 계측자료의 유효성 검증 방법에 대한 연구)

  • Jang, Won-Seok;Jeong, Seong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.150-157
    • /
    • 2020
  • In this study, an algorithm was developed to validate the seismic acceleration measurement data of the seismic acceleration measurement system using measurement data from public buildings currently in operation. Through the results of the study, an algorithm was developed to detect errors and abnormalities in the measurement data itself and the process of generating real-time data (MMA/sec) and event measurement data (MiniSEED), which are the main data generated by the system, and the basic data for determining the direction of inspection through measurement data analysis. It is expected that this will be used as a guideline to determine whether or not the seismic acceleration measurement system, which was managed as receiving/not receiving, is inspected and abnormal types of conditions.

Dynamic Responses of Base Isolation Devices for Telecommunication Equipment in Building Structures (건축물 내 방송통신설비를 위한 면진장치의 동적거동)

  • Jeong, Saebyeok;Choi, Hyoung-Suk;Seo, Young-Deuk;Jung, Donghyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.39-48
    • /
    • 2022
  • In earthquake situations, broadcasting and communication services are directly linked to rapid on-site rescue and effective restoration works. Recently, a variety of base isolation devices are widely introduced on building floors to avoid critical seismic damages of telecommunication facilities. However, in buildings with long fundamental periods, those devices may have undesirable amplification of seismic responses due to resonance effect between the building floors and base isolation devices. This study performs the seismic safety evaluation of two types of base isolation devices deployed for telecommunication facilities in mid- and high-rise buildings through numerical and experimental approaches. It is found that mid- and high-rise buildings can have low-frequency dynamic responses at the top floor when being subjected to design basis earthquake loading. Furthermore, bi-directional shake table testing demonstrated that the selected base isolation devices can exhibit unstable dynamic behaviors under such low-frequency excitations of the floor.

EFFECT OF HEAT CURING METHODS ON THE TEMPERATURE HISTORY AND STRENGTH DEVELOPMENT OF SLAB CONCRETE FOR NUCLEAR POWER PLANT STRUCTURES IN COLD CLIMATES

  • Lee, Gun-Che;Han, Min-Cheol;Baek, Dae-Hyun;Koh, Kyung-Taek
    • Nuclear Engineering and Technology
    • /
    • v.44 no.5
    • /
    • pp.523-534
    • /
    • 2012
  • The objective of this study was to experimentally investigate the effect of heat curing methods on the temperature history and strength development of slab concrete exposed to $-10^{\circ}C$. The goal was to determine proper heat curing methods for the protection of nuclear power plant structures against early-age frost damage under adverse (cold) conditions. Two types of methods were studied: heat insulation alone and in combination with a heating cable. For heat curing with heat insulation alone, either sawdust or a double layer bubble sheet (2-BS) was applied. For curing with a combination of heat insulation and a heating cable, an embedded heating cable was used with either a sawdust cover, a 2-BS cover, or a quadruple layer bubble sheet (4-BS) cover. Seven different slab specimens with dimensions of $1200{\times}600{\times}200$ mm and a design strength of 27 MPa were fabricated and cured at $-10^{\circ}C$ for 7 d. The application of sawdust and 2-BS allowed the concrete temperature to fall below $0^{\circ}C$ within 40 h after exposure to $-10^{\circ}C$, and then, the temperature dropped to $-10^{\circ}C$ and remained there for 7 d owing to insufficient thermal resistance. However, the combination of a heating cable plus sawdust or 2-BS maintained the concrete temperature around $5^{\circ}C$ for 7 d. Moreover, the combination of the heating cable and 4-BS maintained the concrete temperature around $10^{\circ}C$ for 7 d. This was due to the continuous heat supply from the heating cable and the prevention of heat loss by the 4-BS. For maturity development, which is an index of early-age frost damage, the application of heat insulation materials alone did not allow the concrete to meet the minimum maturity required to protect against early-age frost damage after 7 d, owing to poor thermal resistance. However, the combination of the heating cable and the heat insulating materials allowed the concrete to attain the minimum maturity level after just 3 d. In the case of strength development, the heat insulation materials alone were insufficient to achieve the minimum 7-d strength required to prevent early-age frost damage. However, the combination of a heating cable and heat insulating materials met both the minimum 7-d strength and the 28-d design strength owing to the heat supply and thermal resistance. Therefore, it is believed that by combining a heating cable and 4-BS, concrete exposed to $-10^{\circ}C$ can be effectively protected from early-age frost damage and can attain the required 28-d compressive strength.

Research on the Criteria of Remembrance Heritage Registered as World Heritage (세계유산으로 등재된 기억유산의 등재기준에 관한 연구)

  • Kim, Gah Young;Yee, Sun
    • Korean Journal of Heritage: History & Science
    • /
    • v.49 no.4
    • /
    • pp.22-37
    • /
    • 2016
  • This research sought to examine the strategies of cultural heritage proving the negative history to be registered as world heritage, among the World Heritages registered in UNESCO. Therefore, to comprehend "negative history"and the heritages with "instructive value," the new term of "Remembrance Heritage"was suggested, and such cases of world heritage were analyzed. Especially by analyzing the criteria of being registered by focusing on the cases of similar World Heritages with similar historical background or form as Korean DMZ, the criteria of OUV that may be applied when Korean DMZ is promoted to be registered as World Heritage. The research results may be summarized as the following. First of all, Remembrance Heritage is a place in which events of universal significance have occurred, rather than the historical, artistic, landscape, and scholastic value of the heritage itself, and was evaluated as architecture, landscape, or place in which the events or historical steps could be verified through architectural, landscape, archaeological or technical means. Secondly, Remembrance Heritage was often applied to be registered with the criterion (vi), and criterion (iii) or criterion (iv). Thirdly, in case of the Korean DMZ, application of criterion (iv) as heritage proving the age of cold war and criterion (vi) as symbolic value of peace may be possible.

Dynamic responses on traditional Chinese timber multi-story building with high platform base under earthquake excitations

  • Zhang, Xicheng;Ma, Hui;Zhao, Yanli;Zhao, Hongtie
    • Earthquakes and Structures
    • /
    • v.19 no.5
    • /
    • pp.331-345
    • /
    • 2020
  • The multi-story timber structure with high platform base is one of the important architectural types in the traditional Chinese buildings. To study the dynamic characteristics and seismic responses on this kind of traditional structure, the 3-D finite element models of Xi'an drum tower which included the high platform base, upper timber structure and whole structure was established considering the structural form and material performance parameters of the structure in this study. By the modal analysis, the main frequencies and mode shapes of this kind of traditional building were obtained and investigated. The three kinds of earthquake excitations included El-Centro wave, Taft wave and Lanzhou wave were separately imposed on the upper timber structure model and the overall structure model, and the seismic responses on the tops of columns were analyzed. The results of time history analysis show that the seismic response of the upper timber structure is obviously amplified by high platform base. After considering the effect of high platform base, the mean value on the lateral displacement increments of the top column in the overall structure is more than 20.478% and the increase of dynamic coefficients was all above 0.818 under the above three different earthquake excitations. Obviously, it shows that the existence of high platform base has a negative influence on the seismic responses of upper timber structure. And the high platform base will directly affect the safety of the upper timber structure. Therefore, the influence of high platform base on the dynamic response of its upper timber structure cannot be neglected.

Investigation of seismic safety of a masonry minaret using its dynamic characteristics

  • Basaran, Hakan;Demir, Ali;Ercan, Emre;Nohutcu, Halil;Hokelekli, Emin;Kozanoglu, Celalettin
    • Earthquakes and Structures
    • /
    • v.10 no.3
    • /
    • pp.523-538
    • /
    • 2016
  • Besides their spiritual significance, minarets are humanity's cultural heritage to the future generations due to their historical and architectural attraction. Currently, many historical masonry minarets are damaged and destroyed due to several reasons such as earthquakes and wind. Therefore, safety of these religiously significant buildings needs to be thoroughly investigated. The utmost care must be taken into account while investigating these structures. Our study investigated earthquake behavior of historical masonry minaret of Haci Mahmut Mosque. Destructive and non-destructive tests were carried out to determine earthquake safety of this structure. Brick-stone masonry material properties of structure were determined by accomplishing ultrasonic wave velocity, Schmidt Hammer, uniaxial compression (UAC) and indirect tension (Brazilian) tests. Determined material properties were used in the finite element analysis of the structure. To validate the numerical analysis, Operational Modal Analysis was applied to the structure and dynamic characteristics of the structure were determined. To this end, accelerometers were placed on the structure and vibrations due to environmental effects were followed. Finite element model of the minaret was updated using dynamic characteristics of the structure and the realistic numerical model of the structure was obtained. This numerical model was solved by using earthquake records of Turkey with time history analysis (THA) and the realistic earthquake behavior of the structure was introduced.

An Evaluation of the Reliability and Validity of the Automatic Pennation Angle Measuring Program (깃각 자동측정 프로그램의 신뢰도와 타당도 평가)

  • Kim, Jong-Soon
    • PNF and Movement
    • /
    • v.17 no.2
    • /
    • pp.329-337
    • /
    • 2019
  • Purpose: Ultrasound imaging is commonly used to measure the pennation angle of human skeletal muscles in vivo. However, manual assessment of the pennation angle using ultrasound images is subjective and time-consuming and requires a high level of examiner skill. The architectural analysis of human skeletal muscles is thus challenging. Automated approaches using image processing techniques are therefore required to estimate the pennation angle in ultrasound images. The purpose of this study was thus to assess the intra-tester and inter-tester reliability and validity of the pennation angle using an automatic measurement program. Methods: Twenty-two healthy young adults (mean age = 22.55 years) with no medical history of neurological or musculoskeletal disorders voluntarily participated in this study. Ultrasound imaging was used to measure the pennation angle of the gastrocnemius muscle at rest. One examiner acquired images from all the participants. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC) to estimate reliability. Validity was measured using Pearson's correlation coefficient. Results: The intra-rater reliability was excellent for the automatic pennation angle measuring program and the manual pennation angle assessment method (ICC>0.95). The inter-rater reliability was also excellent for both methods (ICC>0.93). All the correlation coefficients for the automatic pennation angle measuring program and the manual pennation angle assessment method were 0.79, which indicated a significantly positive correlation (p<0.05). Conclusion: Pennation angle measurement using the automatic pennation angle measuring program showed acceptable reliability and validity. This study therefore demonstrated that the automatic measuring program was able to automatically measure the pennation angle of skeletal muscles using ultrasound images, and thus made it easy to investigate skeletal muscle architecture.

Performance-based plastic design of buckling-restrained braced frames with eccentric configurations

  • Elnaz Zare;Mohammad Gholami;Esmail Usefvand;Mojtaba Gorji Azandariani
    • Earthquakes and Structures
    • /
    • v.24 no.5
    • /
    • pp.317-331
    • /
    • 2023
  • The buckling-restrained braced frames with eccentric configurations (BRBFECs) are stable cyclic behavior and high energy absorption capacity. Furthermore, they have an architectural advantage for creating openings like eccentrically braced frames (EBFs). In the present study, it has been suggested to use the performance-based plastic design (PBPD) method to calculate the design base shear of the BRBFEC systems. Moreover, in this study, to reduce the required steel material, it has been suggested to use the performance-based practical design (PBPD) method instead of the force-based design (FBD) method for the design of this system. The 3-, 6-, and 9-story buildings with the BRBFEC system were designed, and the finite element models were modeled. The seismic performance of the models was investigated using two suits of ground motions representing the maximum considered earthquake (MCE) and design basis earthquake (DBE) seismic hazard levels. The results showed that the models designed with the suggested method, which had lower weights compared to those designed with the FBD method, had a desirable seismic performance in terms of maximum story drift and ductility demand under earthquakes at both MCE and DBE seismic hazard levels. This suggests that the steel weights of the structures designed with the PBPD method are about 13% to 18% lesser than the FBD method. However, the residual drifts in these models were higher than those in the models designed with the FBD method. Also, in earthquakes at the DBE hazard level, the residual drifts in all models except the PBPD-6s and PBPD-9s models were less than the allowable reparability limit.

A Study on the Organization of the 『Gongchengzuofazeli (工程做法則例)』 (『공정주법칙례(工程做法則例)』의 구성 체계에 관한 연구)

  • Yang, Hee Sick;Han, Dong Soo
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.2
    • /
    • pp.26-45
    • /
    • 2011
  • The Gongchengzuofazeli, which was published in 1734, the 12th year of the Yongzheng (雍正) emperor of the Ching Dynasty, is an authoritative book that discusses the architectural technology and engineering practices at that time. Moreover, buildings constructed during the Ching Dynasty are substantially similar with the book's content. This study is important in that it is done as the first step in conducting a comparative analysis between the Korean and Chinese wood structure mechanism. First, each content of the book is examined according to the editing order. And second, the standard for division between Da-shi (大式) and Xiao-shi (小式) architecture in terms of heavy woodwork method (vol. 1~27) is redefined, from which a new organization is deduced.