• Title/Summary/Keyword: "Effective" block width

Search Result 28, Processing Time 0.034 seconds

Dosimetric Consideration of the Lung Block in the Mantle Field (Mantle Field에서 Lung Block의 선량분포 고려)

  • Yoo Myung-Jin;Sin Byung-Chul;Moon Chang-Woo;Jeung Tae-Sig;Yum Ha-Yong
    • Radiation Oncology Journal
    • /
    • v.13 no.2
    • /
    • pp.199-203
    • /
    • 1995
  • Purpose: To evaluate the dose under lung block as a function of depth and the effectiveness of a block as a function of block width. Materials and Methods : Field size of mantle field was $22.8{\times}32.4cm^2.$ Dose distribution of the mantle field was measured with two dimensional water phantom system. To analyze the effectiveness of the lung block. central axis plane, 5cm off-axis plane, and 10cm off-axis plane were studied. Results: The dose under the lung block was recorded with maximum at the depth between 5cm and 10cm. In the central axis plane, dosimetric block width was $10-15\%$ less than physical block width. In the 5cm off-axis plane, dosimetric block width was $4-9\%$ less than physical block width. In the 10cm off-axis plane, dosimetric block width was $2\%$ less than physical block width. Conclusion: Depth dependence of the dose under the lung block was founded. Also, block width dependence of the lung block was founded. To induce the accurate relation between the physical block width and the 'effective' block width, it needs more detailed understanding of the variables involved.

  • PDF

A Study on Thermal Performance of Micro Channel Water Block for Computer CPU Cooling (컴퓨터 CPU 냉각용 미세채널 워터블록의 열성능에 관한 연구)

  • Kwon, Oh-Kyung;Choi, Mi-Jin;Cha, Dong-An;Yun, Jae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.10
    • /
    • pp.776-783
    • /
    • 2008
  • The object of this paper is to study on the thermal performance of a micro channel water block for computer CPU cooling. The effects of liquid flow rate, micro channel width and height on the thermal performances of water block are investigated experimentally. The water block was fabricated Al and machined with a micro milling. The water block consisted of rectangular micro channels 0.5 to 0.9 mm width and 1.5 to 4.5 mm height. The experiments were conducted using deionized water, over a liquid flow rate ranging from 0.2 to 2.0 kg/min. The base temperature and thermal resistance decrease with increasing of liquid flow rate. The increase of a channel height is more effective on the thermal resistance than the decrease of a channel width. At the flow rate of 0.7 kg/min, input power of 100 W, the base temperature and thermal resistance of sample 6 is $33^{\circ}C$ and $0.13\;^{\circ}C/W$ respectively.

The Design of unevenly leaf width distributed Multileaf Collimator (불균일 폭 분포를 갖는 Multileaf Collimator 설계에 관한 연구)

  • 이병용;장혜숙;조병철
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.45-48
    • /
    • 1994
  • We have studied about leaf-width distribution of Multileaf Collimator(MLC). We have analyzed 1169 treatment fields from 303 patients who have treated by radiation therapy. From this analysis, we can design an unevenly leaf-width distributed MLC, by placing the smaller leaf widths for more frequent blocking region and the larger for less. The average width of total leaves is 0.8 cm, but the effective block width is 0.5-0.6 cm for frequently blocking region(3-6 cm from the field center).

  • PDF

Effect of Line-Width of Optical Sources on Performance of Spectral Amplitude Coding Optical CDMA Systems (광원 라인폭이 Spectral Amplitude Coding Optical CDMA시스템의 성능에 미치는 영향)

  • Jhee, Yoon Kyoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.119-124
    • /
    • 2015
  • In this paper, we analyze the effect of line-width of optical sources on the performance of spectral amplitude coding (SAC) optical code division multiple-access (OCDMA) systems. For a performance analysis we use a symmetric balanced incomplete block design (BIBD) code as the code sequence because we can construct a series of code families by choosing different values of q and m. The ideal BIBD code (m=2) requires narrower line-width than the nonideal BIBD codes when the effective power is large ($P_{sr}=-10dBm$). But the nonideal BIBD codes (m>2) need narrower line-width than the ideal BIBD code when $P_{sr}=-25dBm$.

Atrophic Alveolar Ridge Augmentation using Autogenous Block Bone Graft for Implant Placement (임플란트 식립을 위해 블록형 자가골이식을 이용한 퇴축된 치조골의 재건)

  • Chee, Young-Deok;Cho, Jin-Hyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.2
    • /
    • pp.161-171
    • /
    • 2006
  • Endosseous implants have restored normal function and dental health to many patients. When implants were introduced as an effective treatment modality, their efficacy was limited by the amount of available bone. Today, various grafting procedures can surgically create bone width and volume. Implants can be placed in more ideal locations for successful prosthetic reconstruction. The use of autogenous bone grafts represents the "gold standard" for bone augmentation procedures. Either intraoral or extraoral sites may be considered for donor sites. Alveolar ridge augmentation using autogenous bone block, can be done during implant placement or staged with implant placement, after bone graft healing. In the staged technique, a better implant positioning and the use of wide diameter implants are possible. Alveolar ridge augmentation using autogenous block graft is a predictable way of treatment, for the atrophic alveolar ridge before implant placement. The cases presented in this article clinically demonstrate the efficacy of using a autogenous block graft in generating effective new bone fill for dental implant placement.

Behavior of one way reinforced concrete slabs with styropor blocks

  • Al-Azzawi, Adel A.;Abbas, J;Al-Asdi, Al-Asdi
    • Advances in concrete construction
    • /
    • v.5 no.5
    • /
    • pp.451-468
    • /
    • 2017
  • The problem of reducing the self-weight of reinforced concrete structures is very important issue. There are two approaches which may be used to reduced member weight. The first is tackled through reducing the cross sectional area by using voids and the second through using light weight materials. Reducing the weight of slabs is very important as it constitutes the effective portion of dead loads in the structural building. Eleven slab specimens was casted in this research. The slabs are made one way though using two simple supports. The tested specimens comprised three reference solid slabs and eight styropor block slabs having (23% and 29%) reduction in weight. The voids in slabs were made using styropor at the ineffective concrete zones in resisting the tensile stresses. All slab specimens have the dimensions ($1100{\times}600{\times}120mm$) except one solid specimens has depth 85 mm (to give reduction in weight of 29% which is equal to the styropor block slab reduction). Two loading positions or cases (A and B) (as two-line monotonic loads) with shear span to effective depth ratio of (a/d=3, 2) respectively, were used to trace the structural behavior of styropor block slab. The best results are obtained for styropor block slab strengthened by minimum shear reinforcement with weight reduction of (29%). The increase in the strength capacity was (8.6% and 5.7%) compared to the solid slabs under loading cases A and B respectively. Despite the appearance of cracks in styropor block slab with loads lesser than those in the solid slab, the development and width of cracks in styropor block slab is significantly restricted as a result of presence a mesh of reinforcement in upper concrete portion.

Dosimetric Characteristics on Penumbra Regions of the Multileaf Collimator as Compared with the Lead Alloy Block (다엽 콜리메이터(Multileaf Collimator)와 합금납 차폐물(Lead Alloy Block)의 반 그림자영역의 선량 분포상의 특성 비교)

  • Lee Sang Wook;Oh Young Tack;Kim Woo Cheol;Keum Ki Chang;Yoon Seong Ick;Kim Hyun Soo;Park Won;Chu Seong Sil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.391-396
    • /
    • 1995
  • Purpose : The Conformal Radiation Therapy has bee widely used under favour of development of computer technologies. The delivery of a large number of static radiation fields are being necessary for the conformal irradiation. In this paper we investigate dosimetric characteristics on penumbra regions of a multileaf collimator(MLC), and compare to those of lead alloy block for the optimal use of the system in 3-D conformal radiotherapy. Materials and Methods : The measurement of penumbra by MLC or lead alloy block was performed with 6 or 10 MV X-rays. The film was positioned at a dmax depth and 10 cm depth, and its optical density was determined using a scanning videodensitometer. The effective penumbra, the distance from $80{\%}$ to $20{\%}$ isodose lines and $90{\%}$ to $10{\%}$ were analyzed as a function of the angle between the direction of leaf motion and the edge defined by leaves. Results : Increasing MLC angle ($0-75^{\circ}$) was observed with increasing the penumbra widths and the scalloping effect. There was no definite differences of penumbra width from $80{\%}$ to $20{\%}$ isodose lines, while being the small increase of penumbra width from $90{\%}$ to $10{\%}$ isodose line varing the depth and energy. The effective penumbra width of lead alloy block are agree resonably with those of MLC within 4.8mm. Conclusion : The comparative qualitative study of the penumbra between MLC and lead alloy block demonstrate the clinical acceptability and suitability of the multileaf collimator for 3-D conformal radiotherapy.

  • PDF

The Effects of Crime Prevention on the Improvement of the Physical Environment in Scene of Child Sex Offense by Using 3D Simulation (아동성범죄 발생지의 3D 시뮬레이션을 이용한 물리적 환경 개선양상에 따른 범죄예방 효과분석)

  • Kim, A-Ram;Jung, Sung-Won;Jun, Han-Jong
    • Journal of the Korean housing association
    • /
    • v.25 no.1
    • /
    • pp.23-32
    • /
    • 2014
  • This research progressed space evaluation test with 3D simulation for exterior space of detached housing area among the Seoul spaces of child sex offense in 2010. Based on changing analysis on natural surveillance by spatial changes of each physical element, the purpose is to suggest effective construction planning measure for preventing child sex offense. The results of research are as follows. First, natural surveillance of space's height differences and width differences were compared and analyzed. As the result, footpath shows that stairs of slope didn't make lots of effects on visual block, not block of spatial moving, because of the difference of stair height. Also, in case of parking space, visual connection with footpath is expanded when designing pilotis rather than heightening floor height, so activities of exterior people could be seen more easily. Therefore, natural surveillance was higher. Second, natural surveillance of architectural elements by changes of footpath' width was compared and analyzed. As the result, openness of footpath should be secured rather than openness of architectural element. And, planning autonomy of architectural form could be more expanded when securing openness of footpath.

Behavior of lightweight aggregate concrete voided slabs

  • Adel A. Al-Azzawi;Ali O, AL-Khaleel
    • Computers and Concrete
    • /
    • v.32 no.4
    • /
    • pp.351-363
    • /
    • 2023
  • Reducing the self-weight of reinforced concrete structures problem is discussed in this paper by using two types of self-weight reduction, the first is by using lightweight coarse aggregate (crushed brick) and the second is by using styropor block. Experimental and Numerical studies are conducted on (LWAC) lightweight aggregate reinforced concrete slabs, having styropor blocks with various sizes of blocks and the ratio of shear span to the effective depth (a/d). The experimental part included testing eleven lightweight concrete one-way simply supported slabs, comprising three as reference slabs (solid slabs) and eight as styropor block slabs (SBS) with a total reduction in cross-sectional area of (43.3% and 49.7%) were considered. The holes were formed by placing styropor at the ineffective concrete zones in resisting the tensile stresses. The length, width, and thickness of specimen dimensions were 1.1 m, 0.6 m, and 0.12 m respectively, except one specimen had a depth of 85 mm (which has a cross-sectional area equal to styropor block slab with a weight reduction of 49.7%). Two shear spans to effective depth ratios (a/d) of (3.125) for load case (A) and (a/d) of (2) for load case (B), (two-line monotonic loads) are considered. The test results showed under loading cases A and B (using minimum shear reinforcement and the reduction in cross-sectional area of styropor block slab by 29.1%) caused an increase in strength capacity by 60.4% and 54.6 % compared to the lightweight reference slab. Also, the best percentage of reduction in cross-sectional area is found to be 49.7%. Numerically, the computer program named (ANSYS) was used to study the behavior of these reinforced concrete slabs by using the finite element method. The results show acceptable agreement with the experimental test results. The average difference between experimental and numerical results is found to be (11.06%) in ultimate strength and (5.33%) in ultimate deflection.

Macro Block Placement Using Simulated Annealing (시뮬레이티드 어닐링을 이용한 마크로 블럭의 배치)

  • Park, In-Cheol;Kyung, Chong-Min
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.2
    • /
    • pp.147-154
    • /
    • 1989
  • An effective placement of macro blocks having arbitrary width and height is very important in reducing the chip area and the signal delay. In this paper, we proposed a method of macro block placement to obtain the globally optimal placement using simulated annealing, and an efficient algorithm for eliminating the overlaps between the rectangular macro blocks which may remain even after the simulated annealing process is terminated. Each macro block was enlarged to take into account minimal routing area, and these macro blocks were compacted as much as possible during the placement. This procedure was implemented in C language running on MV10000/UNIX computer system, and good placements were obtained by applying this procedure to two circuits which were consisted of 50 and 160 macro blocks respectively. Several parameters giving great effects to final placements were investigated.

  • PDF