The purpose of this study was to investigate the elastic modulus and magnetic susceptibility related to the stress shielding effect of Zr4-xCu alloys, which are closely related to the potential use as biomaterials, and the formation of artificial defects during MRI tests. The Zr4-xCu test alloys were prepared by casting coupons from commercial Zircaloy4 (Zr4) and oxygen-free copper (OFHC) in a vacuum arc furnace under an argon gas atmosphere. Artificial defects during MRI tests are frequently caused by metallic implants in the body, and low magnetic susceptibility is desirable for implant materials. Implant materials with low elastic modulus due to the physical properties of biomaterials have recently attracted much attention as a means to avoid stress shielding. The magnetic susceptibility of the designed Zr4-xCu alloy was very low, approximately 10-7, which was approximately 10% lower than that of pure Zr and other commercialized metallic biomaterials. In addition, the elastic modulus of this alloy was found to be in the range of 15~25 GPa, which is lower than that of existing commercial biomaterial alloys. Consequently, due to these excellent advantages, Zr4-xCu alloys are expected to be new candidate materials for implants.