DOI QR코드

DOI QR Code

Structural Design and Field Applicability Analysis of a Patent-Based Double-Socket Fire Hose

  • Hyun-Mi Kim (Dept. of Emergency Medical & Rescue Technology, Complex Disaster Emergency Rescue Education and Research Center Inje University) ;
  • Kyong-Jin Park (Dept. of Emergency Medical & Rescue Technology, Complex Disaster Emergency Rescue Training and Research Center Inje University)
  • 투고 : 2026.01.25
  • 심사 : 2026.05.15
  • 발행 : 2026.06.30

초록

This study analyzed the structural design concept and operating principles of a double-socket fire hose based on patented technology and evaluated its applicability to firefighting operations. For fire scenes in South Korea, water-supply outlets and nozzles are typically standardized to two diameters: 40 and 65 mm. This dual-standard configuration often necessitates hose replacement or the use of conversion adapters, which can delay initial response and reduce operational inefficiency. Furthermore, large-diameter (65 mm) fire hoses are associated with significant hose reaction and instability under high-pressure water discharge, resulting in reduced maneuverability and increased safety risks for firefighters. To address these issues, this study investigated double-socket fire hose designed to connect to multiple outlet diameters without requiring hose replacement. A 40-mm hose served as the primary flow path, whereas a concentrically arranged 65-mm outer coupling socket enabled immediate adaptation to different water-supply standards. The structural configuration, coupling mechanism, flow characteristics, and functional features of the double-socket system were analyzed from an engineering perspective. The analysis indicated that the integrated socket structure simplifies the connection process and ensures stable sealing performance under high-pressure conditions. Furthermore, by maintaining a smaller-diameter primary flow path, the double-socket fire hose can mitigate excessive hose reaction and improve maneuverability compared with conventional large-diameter hoses. These characteristics may reduce the physical workload for firefighters and enhance their operational safety. This study provides an academic examination of an integrated fire hose structure that has received limited attention in prior studies focusing on single-diameter hoses or individual connectors. Further experimental validation of flow rate, pressure loss, and reaction force, in conjunction with field-based performance assessments, may support the practical implementation and standardization of double-socket fire hose systems.

키워드

1. Introduction

Firefighting operations require rapid securing of water sources and stable discharge of fire streams to achieve effective and safe fire suppression. The response speed during the initial stage of a fire exerts a critical impact on minimizing casualties and property damage. Therefore, the reliability and operational efficiency of firefighting equipment must be continuously improved. Among firefighting equipment, fire hoses constitute the most fundamental and essential tools for field operations. They must connect and operate rapidly and reliably under diverse field conditions.

In Korea, water-supply outlets and nozzles installed on fire engines and hydrants are generally standardized to two diameters: 40 and 65 mm [1]. Because of this dual-standard system, firefighters are often required to prepare or replace hoses of different diameters depending on the situation, which introduces operational inconvenience during field deployment [2]. This requirement increases the complexity of equipment loading by necessitating multiple hoses on fire engines and also increases the risk of delayed initial response during fire suppression because of the time required to select and connect hoses of appropriate diameters at the scene [3].

In particular, although large-diameter (65 mm) fire hoses provide the advantage of securing high flow rates, they generate significant hose reaction and oscillation under high-pressure discharge conditions. These characteristics complicates handling and concurrently increases the physical workload on firefighters and the risk of accidents [4]. Prolonged physical strain has been associated with reduced job satisfaction and organizational commitment [5], and exacerbates job-related stress via accumulated fatigue and degradation of sleep quality [6].

Prior studies on fire hoses and couplings have primarily focused on hydraulic performance, operational efficiency under field conditions, and occupational safety. Researchers analyzed the influence of hose diameter and length on flow rate and pressure loss, friction losses occurring at hose–nozzle connections, and reaction forces generated during high-pressure water discharge [7,8]. Additionally, firefighting laws, regulations, and equipment standards provide a fundamental framework for field operations by defining safety requirements and operational criteria for firefighting equipment [9].

Studies addressing the field applicability of firefighting equipment have emphasized that, in addition to equipment performance, human factors such as job characteristics of firefighters, individual perceptions, and working environments exert a critical influence on effective equipment utilization [10,11]. These findings suggest that operability and safety must be jointly considered during the equipment design stage.

However, prior studies have predominantly focused on the performance evaluation of single-diameter fire hoses or individual couplings, and investigations of integrated structures capable of responding to multiple water-supply standards with a single hose remain limited [12-14]. Accordingly, the objectives of this study were to systematically examine the structural design concept and operating principles of a patent-based double-socket fire hose and to analyze its potential applicability in firefighting operations [15].

2. Structural Design of Double-Socket Fire Hose

2.1 Basic Structure

The double-socket fire hose employs a small-diameter (40 mm) hose as the primary flow path and features a dual-coupling structure at the hose end, wherein a large-diameter (65 mm) coupling and small- diameter (40 mm) coupling are arranged concentrically. The outer portion consists of a 65-mm large-diameter coupling, whereas a removable 40-mm small-diameter coupling is positioned within the inner region of the larger coupling.

This structure can enable firefighters to selectively use either the large- or small-diameter coupling depending on the water-supply standard at the scene, thereby ensuring compatibility with multiple water sources without the need for additional conversion adapters or hose replacement.

2.2 Fixation and Sealing Mechanism

The small-diameter coupling is designed for insertion at a predetermined depth within the large-diameter coupling, and a retaining shoulder is formed along the inner surface of the large-diameter coupling to prevent excessive insertion. This configuration ensures that the position of the small-diameter coupling remains stable even under high-pressure water flow conditions.

In addition, the gap between the two couplings is minimized to ensure watertightness, and the design enables the use of elastic rubber rings, when required, to further improve the leakage prevention performance.

3. Operating Principle and Functional Characteristics

3.1 Operating Principle of Double-Socket Structure

The double-socket fire hose is designed for selective coupling with water-supply outlets of different diameters installed on fire engines or hydrants. The structure includes a small-diameter coupling socket (120) connected to a small-diameter fire hose in addition to a large-diameter coupling socket (110) that internally accommodates the small-diameter coupling socket (120) and is capable of forward and backward movement along a common axial direction (Fig. 1).

SOOOB6_2026_v29n3_1_641_4_f0001.png 이미지

Fig. 1. Double-Socket Fire Hose.

One end of the large-diameter coupling socket (110) is connected to a large-diameter fire hose of a predetermined length, whereas the opposite end of the large-diameter fire hose forms a sealed joint with the outer surface of the small-diameter coupling socket (120). This joint is composed of a foldable sealing hose (151) designed to enable folding and unfolding, thereby maintaining watertightness without water leakage even during the forward and backward movements of the large-diameter coupling socket (110). The structural arrangements of the small-diameter coupling socket (120), large-diameter coupling socket (110), foldable sealing hose (151), and retaining shoulder (115) are shown in Fig. 1.

The coupling mode, depending on the water-supply diameter, is switched by forward and backward movements of the large-diameter coupling socket (110). When it is connected to a large-diameter water-supply outlet, coupling is achieved using the small-diameter coupling socket (120) inserted within the large-diameter coupling socket (110). Under this condition, the supplied water flow passes through the large-diameter coupling socket (110) and subsequently through the small-diameter coupling socket (120) before being delivered to the small-diameter fire hose. By contrast, when connected to a small-diameter water-supply outlet, the large-diameter coupling socket (110) moves rearward such that the foldable sealing hose (151) is folded, exposing the small-diameter coupling socket (120), which is directly coupled to the water-supply outlet. The two operating states are illustrated in Fig. 2.

SOOOB6_2026_v29n3_1_641_5_f0001.png 이미지

Fig. 2. Double-Socket Fire Hose.

Additionally, when a high-pressure water flow is introduced when the large-diameter coupling socket (110) is coupled to the water-supply outlet, a circular retaining shoulder (115) is formed along the inner circumferential surface of the large-diameter coupling socket (110) to prevent the small-diameter coupling socket (120) from being excessively pushed inward by the water pressure. The retaining shoulder (115) mechanically limits the movement range of the small-diameter coupling socket (120) and simultaneously blocks pressurized water from entering the space between the small-diameter fire hose and foldable sealing hose (151), thereby ensuring structural stability and watertightness.

3.2 Mechanisms for Ensuring Coupling Stability and Watertightness

Stable operation of the double-socket fire hose requires secure coupling under high-pressure water flow and leakage-free water delivery. To satisfy these requirements, the proposed structure incorporates a retaining shoulder that prevents the small-diameter coupling socket from being inserted beyond a predetermined depth within the large-diameter coupling socket. This retaining shoulder mechanically fixes the position of the small-diameter coupling socket while preventing further inward movement caused by water pressure.

Furthermore, the clearance between the small-diameter coupling socket and large-diameter coupling socket is minimized to ensure watertightness, and when necessary, an elastic rubber ring can be applied at the retaining shoulder to further reduce the likelihood of leakage under high-pressure flow conditions. This sealing structure provides high stability by simultaneously utilizing structural fixation and the self-sealing effect induced by water pressure, rather than relying solely on frictional coupling.

Consequently, the double-socket structure offers a structural advantage in minimizing damage to the coupling section and degradation of sealing performance, even during repeated coupling and decoupling operations.

3.3 Flow Characteristics and Hydraulic Stability

The double-socket fire hose differs from conventional 65-mm fire hoses in terms of flow characteristics by employing a 40-mm-diameter primary flow path. Even when water is supplied through the large-diameter coupling socket, the actual discharge flow path is maintained through the 40-mm fire hose, mitigating pressure fluctuations and hose oscillations caused by excessive increases in the flow rate.

This configuration structurally distributes localized pressure losses that may occur during the rapid transition of water flow from a larger to a smaller diameter, thereby reducing the overall reaction force transmitted to the hose. In particular, under high-pressure water flow conditions, such hydraulic stability may reduce the operational burden on firefighters and alleviate fatigue accumulation during prolonged operations.

In addition, by maintaining a single flow path, the structure minimizes turbulence and unbalanced flow that may result during flow branching in conventional Y-shaped connectors.

3.4 Operability and Safety Benefits

A key functional characteristic of the double-socket fire hose is its enhanced operability and onsite safety. Conventional 65-mm fire hoses are heavy and generate significant reaction forces, which complicate handling even for experienced firefighters and restrict mobility in confined spaces or within high-rise buildings.

By utilizing a 40-mm fire hose as the primary flow path, the present structure reduces the weight burden of the hose and mitigates hose reaction during water discharge. This improves the stability of the nozzle operation and enables safer handling during fire suppression by individual firefighters or small teams.

Moreover, simplifying the coupling-diameter conversion process reduces the likelihood of coupling errors or connection delays in the field. This improvement extends beyond operational convenience and can directly contributes to accident prevention during emergencies.

3.5 Comparison with Conventional Fire Hoses and Coupling Methods

In conventional firefighting operations, responding to water sources with different diameters typically requires preparing multiple hoses or using conversion adapters and Y-shaped connectors. However, these approaches present limitations, including increased leakage risk owing to multiple connection points, longer coupling times, and structural complexity.

By contrast, a double-socket fire hose structurally addresses these issues by integrating the coupling components into a single unit. In particular, the ability to switch diameters without replacing the hose reduces the response time and simplifies equipment operation. These functional characteristics are significant for the industrial convergence-oriented development of firefighting equipment, reflecting a design approach that simultaneously considers performance, safety, and operational efficiency.

3.6 Summary

The operating principles and functional characteristics of the double-socket fire hose clearly distinguish the proposed system from conventional fire hose systems by achieving multidiameter compatibility, coupling stability, hydraulic stability, and enhanced operability and safety within a single structure. These characteristics reflect the practical operational requirements of firefighting environments and serve as an important foundation for the analysis of field applicability, as discussed in the following section.

4. Field Applicability

The double-socket fire hose offers advantages in improving operational efficiency while maintaining compatibility with existing firefighting infrastructure, including fire engines, hydrants, and nozzles. Practical improvements are expected in terms of simplifying equipment configurations, reducing the initial connection time, and enhancing operability.

Compared with conventional Y-shaped connectors and multi-hose operation methods, the double-socket structure minimizes the number of connection points, thereby reducing the likelihood of leakage and mechanical failure. However, because this study focuses on the structural design and functional characteristics, evaluations of flow-rate requirements with respect to fire scale and durability under prolonged use remain subjects for future research.

5. Discussion

This study analyzed the structural design and field applicability of a patent-based double-socket fire hose. The proposed design was validated via comparison with conventional fire hoses and coupling systems. The results indicate that the double-socket fire hose provides a structural advantage in accommodating multiple water-supply diameters within a single hose and simplifying firefighting equipment operation [1][3].

Prior studies have indicated that although large-diameter fire hoses are advantageous for securing the water flow required for fire suppression, they present limitations in terms of onsite safety owing to their increased reaction and reduced operability [4][5][6]. By employing a 40-mm fire hose as the primary flow path, the proposed double-socket fire hose can structurally mitigate reaction-related issues, thereby complementing existing research findings.

Furthermore, prior studies analyzing the structural characteristics of fire hoses and couplings have indicated that increased coupling stages and structural complexity may result in higher leakage risks and operational delays [7][8]. The double-socket fire hose addresses these issues by simplifying the onsite operational steps via an integrated coupling structure.

Considering previous studies that emphasized the importance of human factors in the field applicability of firefighting equipment [10-11], the improvement in operability offered by the double-socket fire hose may reduce firefighter fatigue and enhance operational stability. These improvements suggest that advancements in equipment performance can extend beyond individual safety to organizational-level operational efficiency [12-14].

Overall, this study is academically significant in that it structurally reinterprets issues identified in previous fire hose and coupling research via patent-based technology and examines its potential from a field application perspective. With further experimental performance verification and field-based demonstration studies, the scope of this research may be extended to support the practical application and standardization of firefighting equipment [15].

6. Conclusion

This study introduced the structural design concept and operating principles of a patent-based double-socket fire hose, followed by an analysis of its functional characteristics and field applicability. The results indicate that the double-socket fire hose provides operational flexibility by accommodating multiple water-supply diameters using a single hose and may complement the limitations of conventional fire hoses in terms of operability and safety.

With future experimental verification of the flow rate, pressure loss, and reaction force, as well as field application evaluations via actual fire-suppression training, the proposed system is expected to contribute to the practical implementation and standardization of firefighting equipment.

참고문헌

  1. Hall, J. R., The importance of response time in fire suppression, Fire Technology, 36:4, pp.255-268, (2000).
  2. National Fire Protection Association (NFPA), NFPA Fire Protection Handbook, 20th ed., National Fire Protection Association, (2008).
  3. Chin, S. K., Jomaas, G., & Sunderland, P. B., Firefighter nozzle reaction: Analysis of hose tension and reaction forces, Fire Technology, 51:4, pp.1023-1047, (2015). https://doi.org/10.1007/s10694-014-0430-5
  4. McGrattan, K. B., Hostikka, S., McDermott, R., Floyd, J., Vanella, M., & Weinschenk, C., Fire Dynamics Simulator—Technical Reference Guide, NIST Special Publication 1018, National Institute of Standards and Technology, (2019).
  5. Grant, C. C., Fire hose and nozzle hydraulics, Fire Engineering, 164:9, pp.67-74, (2011).
  6. Shupe, J., The two-inch hose in the modern era, Fire Engineering, 175:2, pp.52-59, (2022).
  7. National Fire Protection Association (NFPA), NFPA 1963: Standard for Fire Hose Connections, National Fire Protection Association, (2024).
  8. National Fire Protection Association (NFPA), NFPA 1710: Standard for the Organization and Deployment of Fire Suppression Operations, National Fire Protection Association, (2020).
  9. U.S. Fire Administration (USFA), Safety and Health Considerations for the Design of Fire Stations, FEMA / USFA Technical Report, (2015).
  10. Sullivan, J. P., Human factors in fireground operations, Human Factors, 45:2, pp.240-253, (2003).
  11. International Organization for Standardization (ISO), ISO 9001: Quality management systems— Requirements, ISO, (2015).
  12. International Organization for Standardization (ISO), ISO 45001: Occupational health and safety management systems — Requirements, ISO, (2018).
  13. Smith, R., & Wallace, J., Analysis of hose handling and firefighter injury mechanisms, Safety Science, 82, pp.83-91, (2016).
  14. Wang, L., & Chen, P., Motion stability of fire ladder truck under braking process working conditions, Engineering Failure Analysis, 92:1, pp.312–320, (2018).
  15. Park, K. J., "Fire hose of double coupled socket." Korean Patent Application, No.10-2023-0106206, August 14, (2023)