Acknowledgement
본 논문은 2023~2024년도 청주대학교 연구장학 지원에 의해 수행되었습니다.
References
- Sencoretech Co., Ltd. Development of TSC beams with improved constructability and cross-sectional performance using internal supports. Daejeon (Korea): Korea Technology and Information Promotion Agency for SMEs; c2021. 134 p.
- Sencoretech Co., Ltd. Development of TSC beams with improved structural and seismic performance using internal supports. Daejeon (Korea): Korea Technology and Information Promotion Agency for SMEs; c2023. 105 p.
- Seng Structural Engineering Research Institute. TSC beam method using upper open steel plate. Ilsan (Korea): Korea Agency for Infrastructure Technology Advancement; c2004. Construction New Technology No. 418.
- Son JM, Park JS. Inelastic lateral-torsional buckling strength of noncompact flange H-shaped step beams under pure bending. J Earthq Eng Soc Korea. 2012;12(1):59-60.
- Oh MH, Kim SD, Kim BR, Kim MH, Kim DJ. Experimental study on flexural-compressive strength of SC composite columns with noncompact sections. J Korean Soc Steel Const. 2005;17(4):431-438.
- Park JS, Kim YH, Lee GS. Study on lateral-torsional buckling streng th criteria of compact section T-beams under uniform moment. J Korea Acad –Ind Cooper Soc. 2009;10(8):2038-2043.
- Sim HJ, Kim JH, Lee SH, Choi SO, Lee ET. Experimental evaluation of flexural streng th of deep-web variable-section H-beams. J Korean Soc Steel Const. 2007;19(5):483-492.
- Kim HS, Lee CN, Lee SH, Kim BR. Seismic performance test of concrete-filled U-shaped composite beams and prefabricated columns. Journal of the Architectural Institute of Korea Structure & Construction. 2012;28(4):55-64.
- Hwang HJ, Eom TS, Park HG, Lee CN, Kim HS. Cyclic loading test of TSC composite beam to PSRC column connections. J Korean Soc Steel Const. 2013;25(6):601-612. https://doi.org/10.7781/kjoss.2013.25.6.601
- Lim JJ, Kim DK, Lee SH, Eom TS. Cyclic loading test of external beam-column connections using thin steel plate composite beams. Journal of the Architectural Institute of Korea Structure & Construction. 2017;33(8):11-19.
- Choi YH, Kim SB, Baek KY, Kim SS. Seismic performance evaluation of welded CFT column to Hype composite beam connections. J Korean Soc Steel Const. 2020;32(1):43-53.
- Kim SB, Jeon YH, Cho SH, Choi YH, Kim SS. Seismic performance of deep hybrid composite beam to SRC column connections. J Korean Soc Steel Const. 2017;29(2):135-145.
- Kim SB, Kim SS, Yu DS. Seismic performance of new-shaped U-type hybrid composite beam to column connections. J Korean Soc Steel Const. 2013;25(1):47-59. https://doi.org/10.7781/kjoss.2013.25.1.047
- Lee CH, Park HG, Park CH, Hwang HJ, Lee CN, Kim HS, Kim SB. Cyclic seismic testing of composite concrete-filled U-shaped steel beam to H-shaped column connections. J Struct Eng. (ASCE). 2013;139(3):360-378. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000635
- Hwang HJ, Eom TS, Park HG, Lee SH, Kim HS. Cyclic loading test for beam-column connections of concrete-filled U-shaped steel beams and concrete-encased steel angle columns. J Struct Eng. (ASCE). 2015;141(11):04015020.
- Ministry of Land, Infrastructure and Transport. Korea design standard: steel structures (KDS 41 17 00); c2022.
- American Institute of Steel Construction. Seismic provisions for structural steel buildings (AISC 341-10). Chicago (IL): AISC; c2010.
- Korean Agency for Technology and Standards. Method of tensile test for metallic materials (KS B 0802); c2013.