DOI QR코드

DOI QR Code

Seismic Performance Evaluation of Beam-Column Connections with Internally Reinforced Composite Beam through Experimental Testing

내부지지재로 보강된 합성보의 기둥-보 접합부 내력실험을 통한 내진성능 평가

  • Received : 2025.06.19
  • Accepted : 2025.08.01
  • Published : 2025.09.01

Abstract

This study investigates the seismic performance of beam-column connections using Thin-Walled Steel Composite (TSC) beams and Prestressed Reinforced Concrete (PSRC) columns. TSC beams are constructed from U-shaped thin steel plates that are filled with concrete, allowing for composite action with slabs through the use of shear connectors. They are widely applied in industrial buildings due to excellent strength, stiffness, and constructability. However, slender web plates are prone to local buckling, which may compromise their performance during seismic events. To mitigate this issue, internal supports have been introduced to enhance web stability and concrete confinement. Cyclic loading tests on three specimens-with and without internal supports-demonstrated that the supports increased moment capacity, improved energy dissipation, and effectively reduced buckling. Even slender sections demonstrated performance comparable to that of compact sections. All specimens reached peak strength at a 2.44% rotation angle, with damage localized near the supports. A practical connection detail was also proposed, taking into account constructability and structural reliability. The results provide valuable guidance for the seismic design of composite systems in large-scale structures.

Keywords

Acknowledgement

본 논문은 2023~2024년도 청주대학교 연구장학 지원에 의해 수행되었습니다.

References

  1. Sencoretech Co., Ltd. Development of TSC beams with improved constructability and cross-sectional performance using internal supports. Daejeon (Korea): Korea Technology and Information Promotion Agency for SMEs; c2021. 134 p.
  2. Sencoretech Co., Ltd. Development of TSC beams with improved structural and seismic performance using internal supports. Daejeon (Korea): Korea Technology and Information Promotion Agency for SMEs; c2023. 105 p.
  3. Seng Structural Engineering Research Institute. TSC beam method using upper open steel plate. Ilsan (Korea): Korea Agency for Infrastructure Technology Advancement; c2004. Construction New Technology No. 418.
  4. Son JM, Park JS. Inelastic lateral-torsional buckling strength of noncompact flange H-shaped step beams under pure bending. J Earthq Eng Soc Korea. 2012;12(1):59-60.
  5. Oh MH, Kim SD, Kim BR, Kim MH, Kim DJ. Experimental study on flexural-compressive strength of SC composite columns with noncompact sections. J Korean Soc Steel Const. 2005;17(4):431-438.
  6. Park JS, Kim YH, Lee GS. Study on lateral-torsional buckling streng th criteria of compact section T-beams under uniform moment. J Korea Acad –Ind Cooper Soc. 2009;10(8):2038-2043.
  7. Sim HJ, Kim JH, Lee SH, Choi SO, Lee ET. Experimental evaluation of flexural streng th of deep-web variable-section H-beams. J Korean Soc Steel Const. 2007;19(5):483-492.
  8. Kim HS, Lee CN, Lee SH, Kim BR. Seismic performance test of concrete-filled U-shaped composite beams and prefabricated columns. Journal of the Architectural Institute of Korea Structure & Construction. 2012;28(4):55-64.
  9. Hwang HJ, Eom TS, Park HG, Lee CN, Kim HS. Cyclic loading test of TSC composite beam to PSRC column connections. J Korean Soc Steel Const. 2013;25(6):601-612. https://doi.org/10.7781/kjoss.2013.25.6.601
  10. Lim JJ, Kim DK, Lee SH, Eom TS. Cyclic loading test of external beam-column connections using thin steel plate composite beams. Journal of the Architectural Institute of Korea Structure & Construction. 2017;33(8):11-19.
  11. Choi YH, Kim SB, Baek KY, Kim SS. Seismic performance evaluation of welded CFT column to Hype composite beam connections. J Korean Soc Steel Const. 2020;32(1):43-53.
  12. Kim SB, Jeon YH, Cho SH, Choi YH, Kim SS. Seismic performance of deep hybrid composite beam to SRC column connections. J Korean Soc Steel Const. 2017;29(2):135-145.
  13. Kim SB, Kim SS, Yu DS. Seismic performance of new-shaped U-type hybrid composite beam to column connections. J Korean Soc Steel Const. 2013;25(1):47-59. https://doi.org/10.7781/kjoss.2013.25.1.047
  14. Lee CH, Park HG, Park CH, Hwang HJ, Lee CN, Kim HS, Kim SB. Cyclic seismic testing of composite concrete-filled U-shaped steel beam to H-shaped column connections. J Struct Eng. (ASCE). 2013;139(3):360-378. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000635
  15. Hwang HJ, Eom TS, Park HG, Lee SH, Kim HS. Cyclic loading test for beam-column connections of concrete-filled U-shaped steel beams and concrete-encased steel angle columns. J Struct Eng. (ASCE). 2015;141(11):04015020.
  16. Ministry of Land, Infrastructure and Transport. Korea design standard: steel structures (KDS 41 17 00); c2022.
  17. American Institute of Steel Construction. Seismic provisions for structural steel buildings (AISC 341-10). Chicago (IL): AISC; c2010.
  18. Korean Agency for Technology and Standards. Method of tensile test for metallic materials (KS B 0802); c2013.