DOI QR코드

DOI QR Code

Combination of metal artifact reduction and sharpening filter application for horizontal root fracture diagnosis in teeth adjacent to a zirconia implant

  • Received : 2024.03.19
  • Accepted : 2024.05.10
  • Published : 2024.09.30

Abstract

Purpose: This study examined the influence of metal artifact reduction (MAR), the application of sharpening filters, and their combination on the diagnosis of horizontal root fracture (HRF) in teeth adjacent to a zirconia implant on cone-beam computed tomography (CBCT) examinations. Materials and Methods: Nineteen single-rooted teeth (9 with HRF and 10 without) were individually positioned in the right central incisor socket of a dry human maxilla. A zirconia implant was placed adjacent to each tooth. Imaging was performed using an OP300 Maxio CBCT (Instrumentarium, Tuusula, Finland) unit with the following settings: a current of 8 mA, both MAR modes(enabled and disabled), a 5×5 cm field of view, a voxel size of 0.085 mm, and a peak kilovoltage of 90 kVp. Four oral and maxillofacial radiologists independently evaluated the CBCT scans under both MAR conditions and across 3 levels of sharpening filter application (none, Sharpen 1×, and Sharpen 2×). Diagnostic metrics were calculated and compared using 2-way analysis of variance (α=5%). The weighted kappa test was used to assess intra- and inter-examiner reliability in the diagnosis of HRF. Results: MAR tool activation, sharpening filter use, and their combination did not significantly impact the area under the receiver operating characteristic curve, sensitivity, or specificity of HRF diagnosis (P>0.05). Intra- and inter-examiner agreement ranged from fair to substantial. Conclusion: The diagnosis of HRF in a tooth adjacent to a zirconia implant is not affected by the activation of MAR, the application of a sharpening filter, or the combination of these tools.

Keywords

Acknowledgement

This research was financed in part by Coordenacao de Aperfeicoamento de Pessoal de Nível Superior(CAPES) - Finance Code 001.

References

  1. Bornstein MM, Wolner-Hanssen AB, Sendi P, Von Arx T. Comparison of intraoral radiography and limited cone beam computed tomography for the assessment of root-fractured permanent teeth. Dent Traumatol 2009; 25: 571-7. https://doi.org/10.1111/j.1600-9657.2009.00833.x
  2. Kamburoglu K, Ilker Cebeci AR, Grondahl HG. Effectiveness of limited cone-beam computed tomography in the detection of horizontal root fracture. Dent Traumatol 2009; 25: 256-61. https://doi.org/10.1111/j.1600-9657.2009.00770.x
  3. Girelli CF, de Lima CO, Lacerda MF, Coellho RG, Silveira FF, Nunes E. The importance of bioceramics and computed tomography in the late clinical management of a horizontal root fracture: a case report. J Clin Exp Dent 2020; 12: e514-8.
  4. Oenning AC, de Azevedo Vaz SL, Melo SL, Haiter-Neto F. Usefulness of cone-beam CT in the evaluation of a spontaneously healed root fracture case. Dent Traumatol 2013; 29: 489-93. https://doi.org/10.1111/j.1600-9657.2012.01166.x
  5. May JJ, Cohenca N, Peters OA. Contemporary management of horizontal root fractures to the permanent dentition: diagnosis-radiologic assessment to include cone-beam computed tomography. Pediatr Dent 2013; 35: 120-4.
  6. Ruiz DC, Reis LO, Fontenele RC, Miranda-Viana M, Farias-Gomes A, Freitas DQ. Influence of an adjacent zirconium implant, tube current, and metal artifact reduction algorithm on horizontal root fracture diagnosis in cone beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol 2024; 137: 190-8. https://doi.org/10.1016/j.oooo.2023.10.001
  7. Byakova SF, Novozhilova NE, Makeeva IM, Grachev VI, Kasatkina IV. The detection of vertical root fractures in post-core restored teeth with cone-beam CT: in vivo and ex vivo. Dentomaxillofac Radiol 2019; 48: 20180327.
  8. Gaeta-Araujo H, Nascimento EH, Fontenele RC, Mancini AX, Freitas DQ, Oliveira-Santos C. Magnitude of beam-hardening artefacts produced by gutta-percha and metal posts on cone-beam computed tomography with varying tube current. Imaging Sci Dent 2020; 50: 1-7. https://doi.org/10.5624/isd.2020.50.1.1
  9. Fontenele RC, Machado AH, de Oliveira Reis L, Freitas DQ. Influence of metal artefact reduction tool on the detection of vertical root fractures involving teeth with intracanal materials in cone beam computed tomography images: a systematic review and meta-analysis. Int Endod J 2021; 54: 1769-81. https://doi.org/10.1111/iej.13569
  10. Coelho-Silva F, Martins LAC, Braga DA, Zandonade E, Haiter-Neto F, de-Azevedo-Vaz SL. Influence of windowing and metal artefact reduction algorithms on the volumetric dimensions of five different high-density materials: a cone-beam CT study. Dentomaxillofac Radiol 2020; 49: 20200039.
  11. Bezerra IS, Neves FS, Vasconcelos TV, Ambrosano GM, Freitas DQ. Influence of the artefact reduction algorithm of Picasso Trio CBCT system on the diagnosis of vertical root fractures in teeth with metal posts. Dentomaxillofac Radiol 2015; 44: 20140428.
  12. Gonzalez AR, Tosoni GM, Freitas DQ, Oliveira ML. Influence of sharpening filters on the detection of root fractures using low-dose cone-beam computed tomography. Clin Oral Investig 2022; 26: 4797-803. https://doi.org/10.1007/s00784-022-04444-7
  13. Mouzinho-Machado S, Rosado LP, Coelho-Silva F, Neves FS, Haiter-Neto F, de-Azevedo-Vaz SL. Influence of voxel size and filter application in detecting second mesiobuccal canals in cone-beam computed tomographic images. J Endod 2021; 47: 1391-7. https://doi.org/10.1016/j.joen.2021.06.011
  14. Verner FS, D'Addazio PS, Campos CN, Devito KL, Almeida SM, Junqueira RB. Influence of cone-beam computed tomography filters on diagnosis of simulated endodontic complications. Int Endod J 2017; 50: 1089-96. https://doi.org/10.1111/iej.12732
  15. de Sousa ET, Pinheiro MA, Maciel PP, Sales MA. Influence of enhancement filters in apical bone loss measurement: a cone-beam computed tomography study. J Clin Exp Dent 2017; 9: e516-9.
  16. Bagis N, Kurt MH, Evli C, Camgoz M, Atakan C, Peker Ozturk H, et al. Evaluation of a metal artifact reduction algorithm and an adaptive image noise optimization filter in the estimation of peri-implant fenestration defects using cone beam computed tomography: an in-vitro study. Oral Radiol 2022; 38: 325-35. https://doi.org/10.1007/s11282-021-00561-3
  17. Marinho Vieira LE, Diniz de Lima E, Peixoto LR, Oliveira Pinto MG, Sousa Melo SL, Oliveira ML, et al. Assessment of the influence of different intracanal materials on the detection of root fracture in birooted teeth by cone-beam computed tomography. J Endod 2020; 46: 264-70. https://doi.org/10.1016/j.joen.2019.10.028
  18. Candemil AP, Salmon B, Vasconcelos KF, Oenning AC, Jacobs R, Freitas DQ, et al. Cone beam CT optimisation for detection of vertical root fracture with metal in the field of view or the exomass. Sci Rep 2021; 11: 19155.
  19. Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977; 33: 159-74. https://doi.org/10.2307/2529310
  20. Power M, Fell G, Wright M. Principles for high-quality, high-value testing. Evid Based Med 2013; 18: 5-10. https://doi.org/10.1136/eb-2012-100645
  21. Fontenele RC, Farias Gomes A, Nejaim Y, Freitas DQ. Do the tube current and metal artefact reduction influence the diagnosis of vertical root fracture in a tooth positioned in the vicinity of a zirconium implant? A CBCT study. Clin Oral Investig 2021; 25: 2229-35. https://doi.org/10.1007/s00784-020-03538-4
  22. Oenning AC, Jacobs R, Pauwels R, Stratis A, Hedesiu M, Salmon B, et al. Cone-beam CT in paediatric dentistry: DIMITRA project position statement. Pediatr Radiol 2018; 48: 308-16. https://doi.org/10.1007/s00247-017-4012-9
  23. Farias-Gomes A, Fontenele RC, Rosado LP, Neves FS, Freitas DQ. The metal post material influences the performance of artefact reduction algorithms in CBCT images. Braz Dent J 2022; 33: 31-40.
  24. Freitas DQ, Fontenele RC, Nascimento EHL, Vasconcelos TV, Noujeim M. Influence of acquisition parameters on the magnitude of cone beam computed tomography artefacts. Dentomaxillofac Radiol 2018; 47: 20180151.
  25. Cebe F, Aktan AM, Ozsevik AS, Ciftci ME, Surmelioglu HD. The effects of different restorative materials on the detection of approximal caries in cone-beam computed tomography scans with and without metal artifact reduction mode. Oral Surg Oral Med Oral Pathol Oral Radiol 2017; 123: 392-400. https://doi.org/10.1016/j.oooo.2016.11.008
  26. Bechara B, Alex McMahan C, Moore WS, Noujeim M, Teixeira FB, Geha H. Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth. Dentomaxillofac Radiol 2013; 42: 20120245.
  27. Kamburoglu K, Kolsuz E, Murat S, Eren H, Yuksel S, Paksoy CS. Assessment of buccal marginal alveolar peri-implant and periodontal defects using a cone beam CT system with and without the application of metal artefact reduction mode. Dentomaxillofac Radiol 2013; 42: 20130176.
  28. Gaeta-Araujo H, Leite AF, Vasconcelos KF, Jacobs R. Two decades of research on CBCT imaging in DMFR - an appraisal of scientific evidence. Dentomaxillofac Radiol 2021; 50: 20200367.
  29. Bastos LC, Campos PS, Ramos-Perez FM, Pontual Ados A, Almeida SM. Evaluation of condyle defects using different reconstruction protocols of cone-beam computed tomography. Braz Oral Res 2013; 27: 503-9. https://doi.org/10.1590/S1806-83242013000600010
  30. de Azevedo Vaz SL, Vasconcelos TV, Neves FS, de Freitas DQ, Haiter-Neto F. Influence of cone-beam computed tomography enhancement filters on diagnosis of simulated external root resorption. J Endod 2012; 38: 305-8. https://doi.org/10.1016/j.joen.2011.10.012
  31. Sadowsky SJ. Has zirconia made a material difference in implant prosthodontics? A review. Dent Mater 2020; 36: 1-8. https://doi.org/10.1016/j.dental.2019.08.100
  32. Fontenele RC, Nascimento EH, Vasconcelos TV, Noujeim M, Freitas DQ. Magnitude of cone beam CT image artifacts related to zirconium and titanium implants: impact on image quality. Dentomaxillofac Radiol 2018; 47: 20180021.
  33. Shokri A, Vafaee F, Haghighat L, Shahabi S, Farhadian M, Jamalpour MR. Comparison of the amount of artifacts induced by zirconium and titanium implants in cone-beam computed tomography images. BMC Med Imaging 2022; 22: 156.
  34. Ruiz DC, Rosado LP, Fontenele RC, Farias-Comes A, Freitas DQ. Vertical root fracture diagnosis in teeth with metallic posts: Impact of metal artifact reduction and sharpening filters. Imaging Sci Dent(in press).