DOI QR코드

DOI QR Code

Puncture angle on an endoscopic ultrasound image is independently associated with unsuccessful guidewire manipulation of endoscopic ultrasound-guided hepaticogastrostomy: a retrospective study in Japan

  • Akihisa Ohno (Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University) ;
  • Nao Fujimori (Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University) ;
  • Toyoma Kaku (Department of Gastroenterology, Clinical Research Institute, National Hospital Organization Kyushu Medical Center) ;
  • Kazuhide Matsumoto (Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University) ;
  • Masatoshi Murakami (Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University) ;
  • Katsuhito Teramatsu (Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University) ;
  • Keijiro Ueda (Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University) ;
  • Masayuki Hijioka (Department of Gastroenterology, Clinical Research Institute, National Hospital Organization Kyushu Medical Center) ;
  • Akira Aso (Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University) ;
  • Yoshihiro Ogawa (Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University)
  • 투고 : 2023.09.25
  • 심사 : 2023.11.22
  • 발행 : 2024.09.30

초록

Background/Aims: Although endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is performed globally, the procedure remains challenging. Guidewire manipulation is the most difficult step, and there are few reports on the factors associated with unsuccessful guidewire manipulation. This study aimed to assess the significance of the puncture angle on EUS images and identify the most effective guidewire rescue method for patients with unsuccessful guidewire manipulation. Methods: We retrospectively enrolled 115 patients who underwent EUS-HGS between May 2016 and April 2022 at two centers. The puncture angle between the needle and the intrahepatic bile duct was measured through EUS movie records. Results: Guidewire manipulation was unsuccessful in 28 patients. Receiver operating characteristic (ROC) curves identified an optimal puncture angle cutoff value of 85° (cutoff value, 85°; area under the ROC curve, 0.826; sensitivity, 85.7%; specificity, 81.6%). Multivariate analysis demonstrated that a puncture angle <85° was a significant risk factor for unsuccessful guidewire manipulation (odds ratio, 19.8; 95% confidence interval, 6.42-61.5; p<0.001). Among the 28 unsuccessful cases, 24 patients (85.7%) achieved successful guidewire manipulation using various rescue methods. Conclusions: The puncture angle observed on EUS is crucial for guidewire manipulation. A puncture angle of <85° was associated with unsuccessful guidewire manipulation.

키워드

과제정보

This work was supported in part by JSPS KAKENHI (grant number: JP18K09945) and the Grant of The Clinical Research Promotion Foundation (2022).

참고문헌

  1. Lee TH, Choi JH, Park do H, et al. Similar efficacies of endoscopic ultrasound-guided transmural and percutaneous drainage for malignant distal biliary obstruction. Clin Gastroenterol Hepatol 2016;14:1011-1019.  https://doi.org/10.1016/j.cgh.2015.12.032
  2. Sharaiha RZ, Khan MA, Kamal F, et al. Efficacy and safety of EUS-guided biliary drainage in comparison with percutaneous biliary drainage when ERCP fails: a systematic review and meta-analysis. Gastrointest Endosc 2017;85:904-914.  https://doi.org/10.1016/j.gie.2016.12.023
  3. Artifon EL, Marson FP, Gaidhane M, et al. Hepaticogastrostomy or choledochoduodenostomy for distal malignant biliary obstruction after failed ERCP: is there any difference? Gastrointest Endosc 2015;81:950-959.  https://doi.org/10.1016/j.gie.2014.09.047
  4. Uemura RS, Khan MA, Otoch JP, et al. EUS-guided choledochoduodenostomy versus hepaticogastrostomy: a systematic review and meta-analysis. J Clin Gastroenterol 2018;52:123-130.  https://doi.org/10.1097/MCG.0000000000000948
  5. Wang K, Zhu J, Xing L, et al. Assessment of efficacy and safety of EUS-guided biliary drainage: a systematic review. Gastrointest Endosc 2016;83:1218-1227.  https://doi.org/10.1016/j.gie.2015.10.033
  6. Khan MA, Akbar A, Baron TH, et al. Endoscopic ultrasound-guided biliary drainage: a systematic review and meta-analysis. Dig Dis Sci 2016;61:684-703.  https://doi.org/10.1007/s10620-015-3933-0
  7. Moole H, Bechtold ML, Forcione D, et al. A meta-analysis and systematic review: success of endoscopic ultrasound guided biliary stenting in patients with inoperable malignant biliary strictures and a failed ERCP. Medicine (Baltimore) 2017;96:e5154. 
  8. Vila JJ, Perez-Miranda M, Vazquez-Sequeiros E, et al. Initial experience with EUS-guided cholangiopancreatography for biliary and pancreatic duct drainage: a Spanish national survey. Gastrointest Endosc 2012;76:1133-1141.  https://doi.org/10.1016/j.gie.2012.08.001
  9. Ogura T, Nishioka N, Ueno S, et al. Effect of echoendoscope angle on success of guidewire manipulation during endoscopic ultrasound-guided hepaticogastrostomy. Endoscopy 2021;53:369-375.  https://doi.org/10.1055/a-1199-5418
  10. Ogura T, Masuda D, Takeuchi T, et al. Liver impaction technique to prevent shearing of the guidewire during endoscopic ultrasound-guided hepaticogastrostomy. Endoscopy 2015;47(S 01):E583-E584.  https://doi.org/10.1055/s-0034-1393381
  11. Kawakami H, Kubota Y, Makiyama H, et al. Uneven double-lumen cannula for rescue guidewire technique in endoscopic ultrasonography-guided hepaticogastrostomy. Endoscopy 2017;49:E264-E265.  https://doi.org/10.1055/s-0043-116014
  12. Ohno A, Kaku T, Fujimori N. Balloon guidewire technique during EUS-guided hepaticogastrostomy. Endosc Ultrasound 2022;11:330-331.  https://doi.org/10.4103/EUS-D-21-00067
  13. Ohno A, Fujimori N, Kaku T, et al. Feasibility and efficacy of endoscopic ultrasound-guided hepaticogastrostomy without dilation: a propensity score matching analysis. Dig Dis Sci 2022;67:5676-5684.  https://doi.org/10.1007/s10620-022-07555-z
  14. Ogura T, Okuda A, Ueno S, et al. Prospective comparison study between 19-gauge needle with .025-inch guidewire and 22-gauge needle with novel .018-inch guidewire during EUS-guided transhepatic biliary drainage (with video). Gastrointest Endosc 2022;96:262-268.  https://doi.org/10.1016/j.gie.2022.03.013
  15. Hara K, Okuno N, Haba S, et al. How to perform EUS-guided hepaticogastrostomy easier and safer. J Hepatobiliary Pancreat Sci 2020;27:563-564.  https://doi.org/10.1002/jhbp.774
  16. Cotton PB, Eisen GM, Aabakken L, et al. A lexicon for endoscopic adverse events: report of an ASGE workshop. Gastrointest Endosc 2010;71:446-454.  https://doi.org/10.1016/j.gie.2009.10.027
  17. Isayama H, Hamada T, Yasuda I, et al. TOKYO criteria 2014 for transpapillary biliary stenting. Dig Endosc 2015;27:259-264.  https://doi.org/10.1111/den.12379
  18. Oh D, Park DH, Song TJ, et al. Optimal biliary access point and learning curve for endoscopic ultrasound-guided hepaticogastrostomy with transmural stenting. Therap Adv Gastroenterol 2017;10:42-53.  https://doi.org/10.1177/1756283X16671671
  19. Fugazza A, Colombo M, Spadaccini M, et al. Relief of jaundice in malignant biliary obstruction: when should we consider endoscopic ultrasonography-guided hepaticogastrostomy as an option? Hepatobiliary Pancreat Dis Int 2022;21:234-240.  https://doi.org/10.1016/j.hbpd.2022.03.003
  20. Matsubara S, Nakagawa K, Suda K, et al. Practical tips for safe and successful endoscopic ultrasound-guided hepaticogastrostomy: a state-of-the-art technical review. J Clin Med 2022;11:1591. 
  21. Ueno S, Ogura T, Higuchi K. Moving scope technique for guidewire insertion during endoscopic ultrasound-guided hepaticogastrostomy. Dig Endosc 2021;33:e109-e110.