An experimental study of AAC masonry prisms with chases under compression

  • Gregoria K. Langstang (Department of Civil Engineering, National Institute of Technology Meghalaya) ;
  • Teiborlang Warjri (Department of Civil Engineering, National Institute of Technology Meghalaya) ;
  • Richard B. Lyngkhoi (Department of Civil Engineering, National Institute of Technology Meghalaya) ;
  • Comingstarful Marthong (Department of Civil Engineering, National Institute of Technology Meghalaya)
  • 투고 : 2024.05.27
  • 심사 : 2024.07.24
  • 발행 : 2024.10.25

초록

Installing wiring or plumbing fixtures necessitates creating chases within masonry walls, which, while serving practical purposes, raises a crucial concern regarding the potential compromise of the masonry's structural integrity. Given these concerns, it becomes essential to thoroughly understand the impact of incorporating chases on masonry strength. In this study, 37 AAC masonry prisms (200×330×100 mm3) were cast and tested for compression. The prisms were equipped with chases of various depths -10 mm, 20 mm and 30 mm; and orientations (horizontal, inclined, and vertical), which were then filled with mortar using 1:2, 1:4, and 1:6 cement-to-sand ratios. The primary objectives were to assess the strength decrease in the prisms with different chase characteristics compared to a control specimen and to determine the percentage strength increase due to filling materials compared to unfilled chases. Key findings indicate that as chase depth increases, there is a substantial reduction in prism strength. However, the orientation of the chase does not significantly affect strength reduction. Importantly, filling the chases with mortar leads to a significant increase in prism strength. This study not only unveils the complex impact of chase characteristics on masonry strength but also emphasizes the crucial role of filling materials in strengthening these prisms.

키워드

참고문헌

  1. Al-Sibahy, A. and Edwards, R. (2021), "Effect of chases with renovation techniques on the load carrying capacity of masonry walls", Infrastr., 6, 160. https://doi.org/10.3390/infrastructures6110160.
  2. ASTM C1314-09 (2015), Standard Test Method for Compressive Strength of Masonry Prisms, ASTM International, West Conshohocken, PA, USA.
  3. British Standard EN 1996-1-1 (2005), Eurocode 6: Design of Masonry Structures - Part 1-1: General Rules for Reinforced and Unreinforced Masonry Structures, The British Standards Institution, London, UK.
  4. Banerjee, S., Nayak, S. and Das, S. (2019), "Enhancing the flexural behaviour of masonry wallet using PP band and steel wire mesh", Constr. Build. Mater., 194, 179-191. https://doi.org/10.1016/j.conbuildmat.2018.11.001.
  5. Bhosale, A., Zade, N.P., Davis, R. and Sarkar, P. (2019), "Experimental investigation of autoclaved aerated concrete masonry", J. Mater. Civil Eng., 31(7), 04019109. https://doi.org/10.1061/(asce)mt.1943-5533.0002762.
  6. Costigan, A. and Pavia, S. (2009), "Compressive, flexural and bond strength of brick/lime mortar masonry", Proceedings of PROHITEC 09, Rome, Italy, June.
  7. de Medeiros, G.F., Mohamad, G., Kosteski, L.E., Rodriguez, R.Q. and Milani, A.S. (2022a), "Strength capacity of hollow clay blocks structural masonry - Flange, Chases, and slenderness effects", Eng. Struct., 272, 114943. https://doi.org/10.1016/j.engstruct.2022.114943.
  8. de Medeiros, G.F., Milani, A.S., Lubeck, A., Mohamad, G., Rodriguez, R.Q. and Kosteski, L.E. (2022b), "Numerical analysis of masonry walls with horizontal chases using the Lattice Discrete element method (LDEM)", Eng. Struct., 253, 113647. https://doi.org/10.1016/j.engstruct.2021.113647.
  9. Eurocode 6. EN 1996-1-1 (2005), Design of Masonry Structures - Part 1-1: Common Rules for Reinforced and Unreinforced Masonry Structures, Brussels, Belgium.
  10. Ferretti, D. and Michelini, E. (2021), "The effect of density on the delicate balance between structural requirements and environmental issues for AAC blocks: An experimental investigation", Sustain., 13(13186), 1-21. https://doi.org/10.3390/su132313186.
  11. Ferretti, D., Michelini, E. and Rosati, G. (2015), "Mechanical characterization of autoclaved aerated concrete masonry subjected to in-plane loading: Experimental investigation and FE modeling", Constr. Build. Mater., 98, 353-365. https://doi.org/10.1016/j.conbuildmat.2015.08.121.
  12. Gumaste, K.S., Nanjunda Rao, K.S., Venkatarama Reddy, B.V. and Jagadish, K.S. (2007), "Strength and elasticity of brick masonry prisms and wallettes under compression", Mater. Struct., 40, 241-253. https://doi.org/10.1617/s11527-006-9141-9.
  13. Hendry, E.A.W. (2001), "Masonry walls: Materials and construction", Constr. Build. Mater., 15, 323-330. https://doi.org/10.1016/S0950-0618(01)00019-8.
  14. IS 14858 (2000), Requirements for Compression Testing Machine Used for Testing of Concrete and Mortar, Bureau of Indian Standards (BIS), New Delhi, India.
  15. IS 1905 (1987), Code of Practice for Structural Use of Unreinforced Masonry, Bureau of Indian Standards (BIS), New Delhi, India.
  16. IS 383 (1970), Specification for Coarse and Fine Aggregates From Natural Sources for Concrete, Bureau of Indian Standards (BIS), New Delhi, India.
  17. IS 4031 (Part 6) (1988), Determination of Compressive Strength of Hydraulic Cement Other than Masonary Cement, Bureau of Indian Standards (BIS), New Delhi, India.
  18. Kaluza, M. (2017), "Analysis of in-plane deformation of walls made using AAC blocks strengthened by GFRP mesh", Procedia Eng., 193, 393-400. https://doi.org/10.1016/j.proeng.2017.06.229.
  19. Lyngkhoi, R.B., Warjri, T. and Marthong, C. (2023), "Shear performance of AAC masonry triplets strengthened by reinforcing steel wire mesh in the bed and bed - head joint", Earthq. Struct., 25(3), 149-160. https://doi.org/10.12989/eas.2023.25.3.149.
  20. Michelini, E., Ferretti, D., Miccoli, L. and Parisi, F. (2023), "Autoclaved aerated concrete masonry for energy efficient buildings: State of the art and future developments", Constr. Build. Mater., 402, 132996. https://doi.org/10.1016/j.conbuildmat.2023.132996.
  21. Milani, A.S., Lubeck, A., Mohamad, G., Neto, A.B.D.S.S. and Budny, J. (2021), "Experimental investigation of small-scale clay blocks masonry walls with chases under compression", Constr. Build. Mater., 273, 121539. https://doi.org/10.1016/j.conbuildmat.2020.121539.
  22. Mojsilovic, N. (2011), "Masonry elements with chases: Behaviour under compression", Constr. Build. Mater., 25, 4415-4425. https://doi.org/10.1016/j.conbuildmat.2010.12.027.
  23. Narayanan, N. and Ramamurthy, K. (2000), "Structure and properties of aerated concrete: A review", Cement Concrete Compos., 22, 321-329. https://doi.org/10.1016/S0958-9465(00)00016-0.
  24. Raj, A., Borsaikia, A.C. and Dixit, U.S. (2020a), "Bond strength of Autoclaved Aerated Concrete (AAC) masonry using various joint materials", J. Build. Eng., 28, 101039. https://doi.org/10.1016/j.jobe.2019.101039.
  25. Raj, A., Borsaikia, A.C. and Dixit, U.S. (2020b), "Evaluation of mechanical properties of autoclaved aerated concrete (AAC) block and its masonry", J. Inst. Eng. Ser. A, 101(2), 315-325. https://doi.org/10.1007/s40030-020-00437-5.
  26. Sathiparan, N. and Rumeshkumar, U. (2018), "Effect of moisture condition on mechanical behavior of low strength brick masonry", J. Build. Eng., 17, 23-31. https://doi.org/10.1016/j.jobe.2018.01.015.
  27. Singh, S.B. and Munjal, P. (2017), "Bond strength and compressive stress-strain characteristics of brick masonry", J. Build. Eng., 9, 10-16. https://doi.org/10.1016/j.jobe.2016.11.006.
  28. Vicente, R., Varum, H., Figueiredo, A., Ferreira, T.M. and Mendes da Silva, J.A.R. (2014), "Hollowed clay brick masonry elements with chases: Behaviour under compression", 9th International Masonry Conference, Guimaraes, Portugal, July.