DOI QR코드

DOI QR Code

Feasibility study of spent fuel internal tomography (SFIT) for partial defect detection within PWR spent nuclear fuel

  • Hyung-Joo Choi (Department of Radiation Convergence Engineering, Yonsei University) ;
  • Hyojun Park (Department of Radiation Oncology, Seoul National University Hospital) ;
  • Bo-Wi Cheon (Department of Radiation Convergence Engineering, Yonsei University) ;
  • Hyun Joon Choi (Department of Radiation Oncology, Yonsei University Wonju College of Medicine) ;
  • Hakjae Lee (ARALE Laboratory Co. Ltd) ;
  • Yong Hyun Chung (Department of Radiation Convergence Engineering, Yonsei University) ;
  • Chul Hee Min (Department of Radiation Convergence Engineering, Yonsei University)
  • Received : 2023.12.18
  • Accepted : 2024.01.30
  • Published : 2024.06.25

Abstract

The International Atomic Energy Agency (IAEA) mandates safeguards to ensure non-proliferation of nuclear materials. Among inspection techniques used to detect partial defects within spent nuclear fuel (SNF), gamma emission tomography (GET) has been reported to be reliable for detection of partial defects on a pin-by-pin level. Conventional GET, however, is limited by low detection efficiency due to the high density of nuclear fuel rods and self-absorption. This paper proposes a new type of GET named Spent Fuel Internal Tomography (SFIT), which can acquire sinograms at the guide tube. The proposed device consists of the housing, shielding, C-shaped collimator, reflector, and gadolinium aluminum gallium garnet (GAGG) scintillator. For accurate attenuation correction, the source-distinguishable range of the SFIT device was determined using MC simulation to the region away from the proposed device to the second layer. For enhanced inspection accuracy, a proposed specific source-discrimination algorithm was applied. With this, the SFIT device successfully distinguished all source locations. The comparison of images of the existing and proposed inspection methods showed that the proposed method, having successfully distinguished all sources, afforded a 150 % inspection accuracy improvement.

Keywords

Acknowledgement

This research was supported by the Nuclear Safety Research Program through the Korea Foundation Of Nuclear Safety (KoFONS) using financial resources granted by the Nuclear Safety and Security Commission (NSSC) of the Republic of Korea (No. 2106073); the Korea Institute of Energy Technology Evaluation and Planning (KETEP), and the Ministry of Trade, Industry & Energy (MOTIE) of the Republic of Korea (No. 20214000000070).

References

  1. International Atomic Energy Agency (IAEA), Nuclear Power Reactors in the World", IAEA Reference Data Series No. 2, Vienna, 2023. Available: https://www.iaea.org/publications/15485/nuclear-power-reactors-in-the-world. 
  2. International Atomic Energy Agency (IAEA), Storing Spent Fuel until Transport to Reprocessing or Disposal, IAEA No. NF-T-3.3," IAEA Nuclear Energy Series, pp. 1-54, 2019 [Online]. Available: https://www.iaea.org/publications/12302/storing-spent-fuel-until-transport-to-reprocessing-or-disposal. 
  3. L.E. Smith, P. Jansson, A Viability Study of Gamma Emission Tomography for Spent Fuel Verification : JNT 1955 Phase I Technical Report, no. October, p. 119, 2016 [Online]. Available: https://www.pnnl.gov/publications/abstracts.asp?report=537269. 
  4. E.A. Miller, et al., Hybrid Gama Emission Tomography (HGET): FY16 Annual Report, 2017. 
  5. T. Secretariat, E. States, N. Weapons, A. Iii, Safeguards Statement for 2008 (2008) 1-22. 
  6. M. Mayorov, et al., Gamma emission tomography for the inspection of spent nuclear fuel, in: 2017 IEEE Nucl. Sci. Symp. Med. Imaging Conf. NSS/MIC 2017 - Conf. Proc., 2018, pp. 7-8, https://doi.org/10.1109/NSSMIC.2017.8533017.
  7. M. Kuribara, K. Nemoto, Development of new UV-1.1. Cerenkov viewing device, IEEE Trans. Nucl. Sci. 41 (1) (1994) 331-335, https://doi.org/10.1109/23.281518. 
  8. C. S. Incorporated et al., "Partial Defect Detection in Lwr Spent Fuel Using a," pp. 1-8. 
  9. M.K. Baek, H.J. Choi, K.B. Kim, J.J. Ahn, C.H. Min, Y.H. Chung, Preliminary results of a single photon emission computed tomography (SPECT) detector for inspection of spent fuel assembly, November 2020, Radiat. Phys. Chem. 197 (2022) 110162, https://doi.org/10.1016/j.radphyschem.2022.110162. 
  10. H. joo Choi, et al., Experimental evaluation of fuel rod pattern analysis in fuel assembly using Yonsei single-photon emission computed tomography (YSECT), Nucl. Eng. Technol. 54 (6) (2022) 1982-1990, https://doi.org/10.1016/j.net.2021.12.035. 
  11. H.J. Choi, I.S. Kang, K.B. Kim, Y.H. Chung, C.H. Min, Optimization of single-photon emission computed tomography system for fast verification of spent fuel assembly: a Monte Carlo study, J. Instrum. 14 (7) (2019), https://doi.org/10.1088/1748-0221/14/07/T07002. 
  12. Haneol Leea, Man-Sung Yima, A Novel Scintillator-Photodiode Detector to Detect Partial Defects of PWR Spent Fuel Assemblies for Nuclear Safeguards, Transactions of the Korean Nuclear Society, 2018. 
  13. Yeongjun Kima, Man-Sung Yima, A study of sensitivity of partial defect detection capability using scintillator-photodiode detector with 17x17 spent fuel assemblies, in: Transactions of the Korean Nuclear Society Spring Meeting Jeju, 2019. 
  14. Young S. Ham, et al., Experimental Validation of the Methodology for Partial Defect Verification of the Pressurized Water Reactor Spent Fuel Assemblies, Lawrence Livermore National Lab.(LLNL), Livermore, CA (United States), 2009. 
  15. Haneol Lee, Man-Sung Yim, Investigation of a fast partial defect detection method for safeguarding PWR spent fuel assemblies, Ann. Nucl. Energy 144 (2020) 107496. 
  16. Young S. Ham, Shivakumar Sitaraman, Partial defect tester: a novel approach to detect partial defects in pressurized water reactor spent fuel, Nuclear technology 175 (2) (2011) 401-418. 
  17. Y. Ham, et al., Partial defect verification of spent fuel assemblies by PDET: principle and field testing in Interim Spent fuel Storage Facility (CLAB) in Sweden, in: 2015 4th International Conference on Advancements in Nuclear Instrumentation Measurement Methods and Their Applications (ANIMMA). IEEE, 2015, pp. 1-7. 
  18. Shivakumar Sitaraman, Young S. Ham, Sensitivity Studies for an In-Situ Partial Defect Detector (PDET) in Spent Fuel Using Monte Carlo Techniques, Lawrence Livermore National Lab.(LLNL), Livermore, CA (United States), 2008. 
  19. Shivakumar Sitaraman, Young S. Ham, Symmetric Pin Diversion Detection Using a Partial Defect Detector (PDET), Lawrence Livermore National Lab.(LLNL), Livermore, CA (United States), 2009. 
  20. C.B. Lee, et al., Performance and Safety Tests of High Burnup PWR UO2 Fuel (I): Fuel Manufacturing, Irradiation History, Transportation and Non-destructive Examination, 2003. 
  21. Takahiro Kitajima, Michiaki Kai, Detection Limit of a NaI (Tl) survey meter to measure 131 I accumulation in thyroid glands of children after a nuclear power plant accident, Journal of Radiation Protection and Research 48 (3) (2023) 131-143. 