Acknowledgement
This work was supported by JSPS KAKENHI (grant number JP19K07938 [AS]). The study sponsors did not play any role in the study design, collection, analysis, and interpretation of the data, or in writing the report.
References
- Nakai Y, Isayama H, Wang HP, et al. International consensus statements for endoscopic management of distal biliary stricture. J Gastroenterol Hepatol 2020;35:967-979. https://doi.org/10.1111/jgh.14955
- Davids PH, Groen AK, Rauws EA, et al. Randomised trial of self-expanding metal stents versus polyethylene stents for distal malignant biliary obstruction. Lancet 1992;340:1488-1492. https://doi.org/10.1016/0140-6736(92)92752-2
- Tringali A, Hassan C, Rota M, et al. Covered vs. uncovered self-expandable metal stents for malignant distal biliary strictures: a systematic review and meta-analysis. Endoscopy 2018;50:631-641. https://doi.org/10.1055/s-0043-125062
- Isayama H, Komatsu Y, Tsujino T, et al. A prospective randomised study of "covered" versus "uncovered" diamond stents for the management of distal malignant biliary obstruction. Gut 2004;53:729-734. https://doi.org/10.1136/gut.2003.018945
- Kitano M, Yamashita Y, Tanaka K, et al. Covered self-expandable metal stents with an anti-migration system improve patency duration without increased complications compared with uncovered stents for distal biliary obstruction caused by pancreatic carcinoma: a randomized multicenter trial. Am J Gastroenterol 2013;108:1713-1722. https://doi.org/10.1038/ajg.2013.305
- Nakai Y, Isayama H, Kogure H, et al. Risk factors for covered metallic stent migration in patients with distal malignant biliary obstruction due to pancreatic cancer. J Gastroenterol Hepatol 2014;29:1744-1749. https://doi.org/10.1111/jgh.12602
- Lawrence C, Nieto J, Parsons WG, et al. A newly designed uncovered biliary stent for palliation of malignant obstruction: results of a prospective study. BMC Gastroenterol 2020;20:184.
- Isayama H, Hamada T, Yasuda I, et al. TOKYO criteria 2014 for transpapillary biliary stenting. Dig Endosc 2015;27:259-264. https://doi.org/10.1111/den.12379
- Kahaleh M, Talreja JP, Loren DE, et al. Evaluation of a fully covered self-expanding metal stent with flared ends in malignant biliary obstruction: a multicenter study. J Clin Gastroenterol 2013;47:e96-e100. https://doi.org/10.1097/MCG.0b013e3182951a32
- Telford JJ, Carr-Locke DL, Baron TH, et al. A randomized trial comparing uncovered and partially covered self-expandable metal stents in the palliation of distal malignant biliary obstruction. Gastrointest Endosc 2010;72:907-914. https://doi.org/10.1016/j.gie.2010.08.021
- Lee JH, Krishna SG, Singh A, et al. Comparison of the utility of covered metal stents versus uncovered metal stents in the management of malignant biliary strictures in 749 patients. Gastrointest Endosc 2013;78:312-324. https://doi.org/10.1016/j.gie.2013.02.032
- Yang MJ, Kim JH, Yoo BM, et al. Partially covered versus uncovered self-expandable nitinol stents with anti-migration properties for the palliation of malignant distal biliary obstruction: a randomized controlled trial. Scand J Gastroenterol 2015;50:1490-1499. https://doi.org/10.3109/00365521.2015.1057219
- Krokidis M, Fanelli F, Orgera G, et al. Percutaneous treatment of malignant jaundice due to extrahepatic cholangiocarcinoma: covered Viabil stent versus uncovered Wallstents. Cardiovasc Intervent Radiol 2010;33:97-106. https://doi.org/10.1007/s00270-009-9604-9
- Krokidis M, Fanelli F, Orgera G, et al. Percutaneous palliation of pancreatic head cancer: randomized comparison of ePTFE/FEP-covered versus uncovered nitinol biliary stents. Cardiovasc Intervent Radiol 2011;34:352-361. https://doi.org/10.1007/s00270-010-9880-4
- Knyrim K, Wagner HJ, Pausch J, et al. A prospective, randomized, controlled trial of metal stents for malignant obstruction of the common bile duct. Endoscopy 1993;25:207-212. https://doi.org/10.1055/s-2007-1010294
- Prat F, Chapat O, Ducot B, et al. A randomized trial of endoscopic drainage methods for inoperable malignant strictures of the common bile duct. Gastrointest Endosc 1998;47:1-7. https://doi.org/10.1016/S0016-5107(98)70291-3
- Yamao K, Takenaka M, Ogura T, et al. Utility and safety of a novel fully covered metal stent in unresectable distal malignant biliary obstruction. Dig Dis Sci 2020;65:3702-3709. https://doi.org/10.1007/s10620-020-06114-8
- Marui S, Uza N, Yamazaki H, et al. Utility of laser-cut covered self-expandable metal stents for unresectable malignant distal biliary obstruction: a single-center experience. Endoscopy 2020;52:664-668. https://doi.org/10.1055/a-1149-1700
- Kogure H, Ryozawa S, Maetani I, et al. A prospective multicenter study of a fully covered metal stent in patients with distal malignant biliary obstruction: WATCH-2 study. Dig Dis Sci 2018;63:2466-2473. https://doi.org/10.1007/s10620-017-4875-5
- Park SB, Kim HW, Kang DH, et al. Metallic or plastic stent for bile duct obstruction in ampullary cancer? Dig Dis Sci 2012;57:786-790. https://doi.org/10.1007/s10620-011-1909-2
- Isayama H, Nakai Y, Toyokawa Y, et al. Measurement of radial and axial forces of biliary self-expandable metallic stents. Gastrointest Endosc 2009;70:37-44. https://doi.org/10.1016/j.gie.2008.09.032