Acknowledgement
This research was supported by the Korea Energy Technology Evaluation and Planning and Ministry of Trade, Industry and Energy under Grant (2019381010001A).
References
- Prabhala, V.A., Baddipadiga, B.P., Fajri, P., Ferdowsi, M.: An overview of direct current distribution system architectures & benefits. Energies 11(9), 2463 (2018). https://doi.org/10.3390/en11092463
- Engel, S.P., Soltau, N., Stagge, H., De Doncker, R.W.: Improved instantaneous current control for high-power three-phase dualactive bridge DC-DC converters. IEEE Trans. Power Electron. 29(8), 4067-4077 (2014) https://doi.org/10.1109/TPEL.2013.2283868
- Lee, J.Y., Choi, H.J., Kim, J.Y., Jung, J.H.: A control method to improve power conversion efficiency of three-level NPC-based dual active bridge converter. Trans. Korean Inst. Power Electron. 22(2), 150-158 (2017) https://doi.org/10.6113/TKPE.2017.22.2.150
- Cha, H., Jang, J., Park, H., Moon, G.: A current limiter using current-mode control for low-voltage DC distribution network. Proc. IEEE Int. Power Electron. Motion Control Conf., Harbin, China, pp. 1-6. (2016)
- Cao, H., Hong, S., Cho, G.: A current limiting control method for the inrush current suppression of a 48 V power outlet. IEEE Trans. Power Electron. 31(9), 6572-6582 (2016)
- Jiang, T., Cairoli, P., Rodrigues, R., Du, Y.: Inrush current limiting for solid state devices using NTC resistor. SoutheastCon 2017 Concord, NC, USA, 1-7 (2017)
- Kai, T.:Development of solid state circuit breakers for 380V DC microgrid Protection, NC state University (2017)
- Qin, H., Kimball, J.W.: Generalized average modeling of dual active bridge DC-DC converter. IEEE Trans. Power Electron. 27(4), 2078-2084 (2012) https://doi.org/10.1109/TPEL.2011.2165734
- Jeon, C., Heo, K.-W., Ryu, M.-H., Jung, J.-H.: Control technique of triple-active-bridge converter and its effective controller design based on small-signal model for islanding mode operation. Trans. Korean Inst. Power Electron. 27(3), 192-199 (2022)
- Yao, K., Ren, Y., Lee, F.C.: Critical bandwidth for the load transient response of voltage regulator modules. IEEE Trans. Power Electron. 19(6), 1454-1461 (2004). https://doi.org/10.1109/TPEL.2004.836669
- Kim, Y.D., Cho, K.M., Moon, G.W.: Hold up time extension technique for high efficiency, high power density server power supply. Trans. Korean Inst. Power Electron. 15(2), 96-102 (2010) https://doi.org/10.6113/TKPE.2010.15.2.96
- Jang, Y., Jovanovic, M.M., Dillman, D.L.: Hold-up time extension circuit with integrated magnetics. IEEE Trans. Power Electron. 21(2), 394-400 (2006). https://doi.org/10.1109/TPEL.2005.869750